IEEE 2026 NSS MIC RTSD

Please note! All times in the online program are given in Madrid - Europe (CET) times!

Madrid - Europe ()
Oct 23, 2026, 5:59:34 PM
Your time ()
n/a
Madrid - Europe ()
Oct 23, 2026, 5:59:34 PM
Our Sponsors:

To search for a specific ID please enter the hash sign followed by the ID number (e.g. #123).

Young Investigator Session (oral)

Session chair: Roncali, Emilie, Dr. (University of California, Davis, Department of Biomedical Engineering, Davis, USA); Catana, Ciprian, Dr. (Massachusetts General Hospital and Harvard Medical School, Radiology/A.A. Martinos Center for Biomedical Imaging, Charlestown, USA)
 
Shortcut: MIC-11
Date: Friday, 13 November, 2026, 9:00 - 11:00
Location: FEDERICO GARCÍA LORCA
Session type: MIC Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

9:00 MIC-11-01

Toward Clinical Deployment of Complex PET Designs via Fast In-System Calibration (#1486)

J. Thull1, Y. Kuhl1, B. Weissler1, 2, D. Schug1, 2, V. Schulz1, 2

1 RWTH Aachen University, Chair of Imaging and Computer Vision, Aachen, North Rhine-Westphalia, Germany
2 Hyperion Hybrid Imaging Systems GmbH, Aachen, North Rhine-Westphalia, Germany

Abstract

Accurate positron emission tomography (PET) depends on calibration of detector alignment, gamma interaction positioning, and coincidence timing, which jointly define line-of-response (LOR) and time-of-flight (TOF) information. Conventional workflows calibrate these quantities in separate stages using dedicated acquisitions, hardware, or phantoms. This is particularly burdensome for light-sharing detectors, where these quantities are coupled through the detector response but are typically treated as separate calibration tasks. We introduce a differentiable in-system calibration framework that enables rapid scanner-level calibration by replacing staged workflows with a single coincidence-level optimization. A shared neural network predicts local interaction positions and timing corrections from single-event readouts, while learnable detector poses map predictions into scanner coordinates. Singles are processed independently, and coincidence information enters only via physical LOR and TOF construction. This prevents source-label access at the network input while enforcing scanner-level consistency. The framework was trained on 28M coincidences from 450 randomized 22Na point-source positions acquired on a semi-monolithic preclinical PET system. In hot-rod reconstructions, the proposed calibration achieved image quality on par with a conventional blueprint and fan-beam workflow, as assessed by peak signal-to-noise ratio, structural similarity, coefficient of variation, recovery coefficients, and peak-to-valley ratios. Differentiable in-system calibration therefore compresses labor-intensive staged workflows into a unified physics-constrained optimization completed in hours, reducing effort and mechanical constraints without sacrificing reconstruction performance.

AcknowledgmentThis work was funded by BMFTR and the Ministry of Culture and Science of North Rhine-Westphalia through NHR4CES. We thank NVIDIA for four RTX 6000 Ada GPUs through its Grant Program.
References
[1] Thull, J, Kuhl, Y, Mueller, F, Schug, D, Weissler, B & Schulz, V 2026, ‘Beyond mechanics: Maximum-likelihood-driven PET detector alignment calibration’, Medical Physics, 53(1), e70256, Wiley.
[2] Kuhl, Y, Mueller, F, Naunheim, S, Bovelett, M, Lambertus, J, Schug, D, Weissler, B, Gegenmantel, E, Gebhardt, P & Schulz, V 2024, ‘A finely segmented semi-monolithic detector tailored for high-resolution PET’, Medical Physics, 51(5), 3421–3436, Wiley.
[3] Kuhl, Y, Mueller, F, Thull, J, Naunheim, S, Schug, D & Schulz, V 2025, ‘3D in-system calibration method for PET detectors’, Medical Physics, 52(1), 232–245, Wiley.
Keywords: pet, in-system calibration
9:15 MIC-11-02

A Compact Preclinical PET Scanner Achieving NEMA-Standard Sub-0.5 mm Spatial Resolution via Analytic FBP Reconstruction (#1867)

C. Li1, H. Wen1, Y. Jiang1, 2, Y. Hou1, K. Wang1, J. Jiang1

1 Beijing Normal University, Key Laboratory of Beam Technology of Ministry of Education, School of Physics and Astronomy, Beijing, China
2 Beijing Normal University, Key Laboratory of Radiopharmaceuticals of the Ministry of Education, NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals (National Medical Product Administration), College of Chemistry, Beijing, China

Abstract

PET is a cornerstone of preclinical imaging, where achieving ultra-high spatial resolution is paramount for the precise quantification of sub-regional metabolism. While commercial scanners typically yield 1.0–1.5 mm resolution, advanced research prototypes target sub-millimeter precision. This study introduces a compact preclinical PET scanner achieving NEMA-standard sub-0.5 mm spatial resolution via the analytic filtered back-projection (FBP) algorithm. To the best of our knowledge, this is the first reported system demonstrating such resolution through FBP. The dual-ring scanner features a 64 mm transaxial and 53.2 mm axial field of view, integrating 16 modules of 44 × 44 LYSO crystal arrays (0.497 × 0.497 × 5 mm3 elements). These arrays are coupled to Hamamatsu Multi-Pixel Photon Counters (MPPCs, S14161-3050HS-08) and managed by a PETsys TOFPET2 ASIC system. System performance was characterized following NEMA NU 4-2008 protocols. The scanner demonstrated an overall energy resolution of 13.43% and an absolute sensitivity of 0.87% (350–650 keV). Peak true and noise equivalent count rates (NECR) were 7.61 kcps and 6.02 kcps, respectively, with a scatter fraction of 8.92%. FBP reconstruction of a point source demonstrated the system achieved average FWHM resolutions of 0.90 mm, 0.86 mm, and 0.69 mm in the radial, tangential, and axial directions, respectively, reaching a peak resolution of 0.48 mm. Imaging of a Micro-Derenzo phantom resolved 0.4 mm rods via iterative reconstruction. In vivo studies using 18F-FDG and 18F-Florbetazine delineated precise tracer distributions within sub-regional structures. While the 5-mm scintillator thickness involves a trade-off in sensitivity, the system establishes a benchmark for spatial fidelity in preclinical instrumentation. Future work will integrate thicker crystals with depth-of-interaction capabilities to enhance sensitivity without compromising spatial precision.

AcknowledgmentThis work was supported in part by the NSFC (No. 12475336).
References
[1] S. Yamamoto et al., "Development of an ultrahigh resolution Si-PM based PET system for small animals," Physics in Medicine and Biology, vol. 58, no. 21, pp. 7875-7888, October 2013, doi: 10.1088/0031-9155/58/21/7875.
[2] H. G. Kang, H. Tashima, H. Wakizaka, M. Higuchi, and T. Yamaya, "Sub-0.5 mm Resolution PET Scanner with 3-Layer DOI Detectors for Rodent Neuroimaging," IEEE Transactions on Medical Imaging, vol. 45, no. 4, pp. 1423-1431, April 2026, doi: 10.1109/TMI.2025.3627815.
[3] C. Li et al., "Design and Initial Evaluation of a Prototype Preclinical PET Scanner with Submillimeter Spatial Resolution for Highprecision Imaging," in 2025 IEEE NSS/MIC/RTSD, Yokohama, Japan, 2025, pp. 1-1, doi: 10.1109/NSS/MIC/RTSD57106.2025.11286554.
[4] Z. Yuan et al., "GPU‐based list‐mode TOF PET image reconstruction with complete correction techniques," Medical Physics, vol. 53, no. 1, pp. e70216, 2026, doi: 10.1002/mp.70216.
Keywords: Preclinical PET, Ultra-high spatial resolution, Instrumentation
9:30 MIC-11-03

Development of a ring-type Quantum Entanglement PET Imaging System and Application of a Novel Image Reconstruction Algorithm to In-Vivo Imaging (#1680)

K. Nakamura1, M. Fujimoto2, P. Caradonna1, M. Uenomachi3, L. Stephenson4, D. Watts4, K. Shimazoe1, 2

1 The University of Tokyo, Department of Nuclear Engineering and Management, Graduate School of Engineering, Tokyo, Japan
2 The University of Tokyo, Department of Bioengineering, Graduate School of Engineering, Tokyo, Japan
3 Institute of Science Tokyo, Institute of Integrated Research, Tokyo, Japan
4 University of York, York, United Kingdom

Abstract

Current positron emission tomography (PET) imaging is fundamentally limited by physical background noise, such as scatter and random coincidences, which significantly degrade image quality and quantitative accuracy. Quantum-entangled PET (QEPET) is a promising solution that utilizes the inherent orthogonal polarization correlation of annihilation photon pairs to physically reject noise. However, its practical application to in-vivo imaging has been a major challenge due to the severe reduction in usable event statistics caused by strict event selection. In this study, we developed a triple-ring PET scanner consisting of 24 Ce:GAGG modules (8×8 arrays of 2.5×2.5×9.0 mm³ pixels at 3.2 mm pitch; 1536 pixels in total) arranged in three axial rings with an inner radius of 36.7 mm, read out by SiPMs via dynamic time-over-threshold circuits, achieving an energy resolution of 9.5% at 511 keV and a coincidence timing resolution of 16.8 ns. By selecting events within a scattering-angle range of 70°–121° and an azimuthal-angle difference of 80°–100°, we obtained a modulation contrast ratio of 1.91, which clearly exceeds the classical limit of 1.63, confirming the entanglement of annihilation photon pairs. Furthermore, to overcome the limited counting statistics of conventional QEPET, we developed a novel reconstruction algorithm that seamlessly integrates the high-statistics structural information of standard PET into the iterative MLEM process. In phantom experiments, this approach improved the SBR to ~1.25× that of raw QEPET while preserving an SNR ~1.27× that of standard PET, achieving the highest CNR among the compared methods. Finally, we performed in-vivo QEPET imaging of a tumor-bearing mouse. The developed method effectively suppressed the granular noise characteristic of conventional QEPET while demonstrating highly localized tracer accumulation, thereby verifying its superiority over both standard PET and conventional QEPET.

References
[1] Holmes, TJ, Snyder, DL, Ficke, DC 2007, 'The effect of accidental coincidences in time-of-flight positron emission tomography', IEEE Transactions on Medical Imaging, vol. 3, no. 2, pp. 68-79, New York: IEEE.
[2] Moskal, P 2024, 'Positron emission tomography could be aided by entanglement', Physics, vol. 17, p. 138, College Park: American Physical Society.
[3] Watts, DP et al. 2021, 'Photon quantum entanglement in the MeV regime and its application in PET imaging', Nature Communications, vol. 12, no. 1, p. 2646, London: Nature Publishing Group.
[4] Nakamura, K et al. 2025, 'Monte Carlo assessment of entanglement-based positron emission tomography', Acta Physica Polonica A, vol. 148, no. 6, p. S138, Warsaw: Polish Academy of Sciences.
[5] Cheng, J-C et al. 2017, 'Incorporating HYPR de-noising within iterative PET reconstruction (HYPR-OSEM)', Physics in Medicine & Biology, vol. 62, no. 16, pp. 6666-6687, Bristol: IOP Publishing.
[6] Mistretta, CA et al. 2006, 'Highly constrained backprojection for time-resolved MRI', Magnetic Resonance in Medicine, vol. 55, no. 1, pp. 30-40, Hoboken: Wiley.
Keywords: Positron emission tomography, quantum entanglement, image reconstruction, HYPR, in-vivo imaging
9:45 MIC-11-04

SIMPLE-DIP: Positronium Lifetime Image Reconstruction Using Deep Image Prior (#2252)

B. Huang1, J. Qi1

1 University of California, Davis, Biomedical Engineering, Davis, California, United States of America

Abstract

Positronium lifetime tomography (PLT) is an emerging imaging modality for imaging positronium lifetime in vivo. Previously, we developed SIMPLE (Statistical IMage reconstruction of Positron Lifetime via time-wEighting), a reconstruction framework for estimating average positron lifetime images, and demonstrated high-resolution imaging on a phantom at clinical activity levels. However, the reconstruction problem remains highly ill-posed, particularly under low-count and high-random conditions. In this work, we propose SIMPLE-DIP, a deep image prior (DIP)-based reconstruction method that regularizes SIMPLE without requiring external training data. The proposed approach employs a single patient-specific U-Net that takes a prior anatomical image as input and jointly constrains both the activity and lifetime-weighted images during reconstruction. Computer simulations using a brain phantom show that SIMPLE-DIP effectively suppresses image noise while preserving lifetime contrast and improving lesion recovery, outperforming the compared SIMPLE formulations regularized by the quadratic penalty or independent DIPs. These results suggest that the proposed SIMPLE-DIP is a promising method for high-resolution positronium lifetime imaging.

AcknowledgmentThis work is supported by the National Institutes of Health, under Grant No. U01AG82845.
References
[1] Moskal, P, Bilewicz, A, Das, M, et al., 2025, ‘Positronium Imaging: History, Current Status, and Future Perspectives’, IEEE TRPMS, Vol. 8, No. 9, 981-1001
[2] Huang, B, Dai, B, Lapi, SE, Liles, G, Karp, JS, Qi, J, 2025, ‘High-Resolution Positronium Lifetime Tomography at Clinical Activity Levels on the PennPET Explorer’, Journal of Nuclear Medicine, Vol. 66, No.9, Page 1464--1470
[3] Huang, B, Wang, Z, Zeng, X, Goldan, AH, Qi, J, 2025, ‘Fast high-resolution lifetime image reconstruction for positron lifetime tomography’, Communications Physics, Vol. 8, No. 1, Page 181
[4] Gong, K, Catana, C, Qi, J, Li, Q, 2019, ‘PET Image Reconstruction Using Deep Image Prior’, IEEE TMI, Vol. 38, No. 7, 1655-1665
[5] Moskal, M, Baran, J, Bass, S, et al., 2024, ‘Positronium image of the human brain in vivo’, Science Advances, Vol. 10, No. 37, Page eadp2840
Keywords: Positronium lifetime, reconstruction, SIMPLE, PET, deep image prior
10:00 MIC-11-05

AI-Based Predictive Dosimetry from PET for 177Lu-PSMA Radiopharmaceutical Therapy for Prostate Cancer (#2210)

B. Lei1, T.-A. Song1, F. Yang1, V. Balaji1, J. Dutta1

1 University of Massachusetts Amherst, Biomedical Engineering, Amherst, Massachusetts, United States of America

Abstract

Personalized 177Lu-PSMA-617 radiopharmaceutical therapy (RPT) for prostate cancer requires patient-specific dosimetry, but post-therapy SPECT imaging for dose computation is not universally performed. In contrast, pre-therapy PSMA PET is widely available and often mandatory for patient selection. PET-based predictive dosimetry therefore has the potential to enable personalized treatment planning before RPT administration. We developed a machine learning framework for organ-level predictive dosimetry from pre-therapy PET, where PET-derived organ features are used to predict kinetic parameters of post-therapy SPECT time-activity curves (TACs). Organ masks for the liver, spleen, and bilateral kidneys were used to extract PET features. Serial 177Lu-PSMA SPECT images at multiple post-injection time points provided reference organ activity values, from which mono-exponential fitting yielded organ TACs and time-integrated activities (TIAs). Absorbed dose was computed from TIAs using the MIRD formalism with organ-specific S values. Our deep learning model predicting kinetic parameters outperformed a comparable deep learning model predicting TIA directly, as well as three classical machine learning models predicting kinetic parameters. This workflow demonstrates the feasibility of forecasting organ absorbed dose from pre-therapy PET, supporting individualized therapeutic regimen planning.

Keywords: RPT, Lu177PSMA, PET Predictive Dosimetry, AI
10:15 MIC-11-06

Event-Resolved Parent-Progeny Discrimination Using CMOS Lensless Radiomicroscopy for 225Ac Targeted Alpha Therapy (#2026)

H. Chu1, 3, J.S. Lee1, 2

1 Seoul National University, Interdisciplinary Program in Bioengineering, College of Engineering, Seoul, Republic of Korea
2 Seoul National University, Department of Nuclear Medicine, Seoul, Republic of Korea
3 Seoul National Graduate School, Integrated Major in Innovative Medical Science, Seoul, Republic of Korea

Abstract

Although targeted alpha therapy (TAT) using 225Ac has demonstrated high therapeutic efficacy, clinical translation remains limited due to redistribution of daughter isotopes, leading to off-target dose. Therefore, discriminating localized emissions from redistributed emitting progeny is significant for small-scale dosimetry and radiopharmaceutical evaluation. Here, we propose a low-cost CMOS-based lensless radiomicroscopy system for direct / discrimination using cluster morphology. Event level features extracted from 210Po and 90Sr measurements were used for classification applying both a physics-driven probability density function (PDF) approach and a data-driven multilayer perceptron (MLP). Both methods achieved > 98% accuracy with AUC > 0.99. Mixed-source experiments mimicking 225Ac decay conditions demonstrated robust event-level discrimination. These results indicate that cluster morphology encodes sufficient physical information to monitor daughter isotope migration, enabling pathway toward quantifying parent and progeny distributions in radiopharmaceutical imaging.

References
[1] Robin, Peter, 2024, 'Digital autoradiography and small-scale dosimetry techniques for alpha-particle radiopharmaceutical therapy', PhD dissertation, University of California, Berkeley: University of California
 
[2] Klein, Justin S., Tae Jin Kim, and Guillem Pratx. 2023, 'Development of a lensless radiomicroscope for cellular-resolution radionuclide imaging' Journal of Nuclear Medicine 64.3 (2023): 479-484.
Keywords: targeted radiopharmaceutical therapy, digital autoradiography, dosimetry, particle discrimination
10:30 MIC-11-07

Physics-Guided Implicit Neural Representation for 3D Ac-225 Compton Imaging (#1786)

G. Song1, B. Das2, J. Kim3, Y. Seo2, 4, J. Kim1, G. Cho1, J. Caravaca5

1 Korea Advanced Institute of Science and Technology, Department of Nuclear and Quantum Engineering, Daejeon, Republic of Korea
2 University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, California, United States of America
3 Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
4 University of California, Berkeley, Department of Nuclear Engineering, Berkeley, California, United States of America
5 Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, California, United States of America

Abstract

Actinium-225 (Ac-225) is a promising alpha-emitting radionuclide for targeted alpha therapy, and Compton cameras have emerged as a potential imaging solution for this radionuclide. We developed a physics-guided implicit neural representation (PG-INR) framework for Ac-225 Compton image reconstruction that does not require any ground truth data. Unlike conventional deep learning approaches, the proposed method incorporates physical laws directly into the training process by embedding physics-based loss terms, including maximum-likelihood estimation and Klein-Nishina differential cross section. This enables unsupervised learning solely guided by the measurement results. Furthermore, by representing the reconstructed image as a continuous implicit neural function, the framework achieves resolution enhancement beyond the native voxel grid. The proposed method was evaluated against a conventional ordered subsets expectation maximization (OSEM) algorithm using measured Compton imaging data from a mouse phantom and a Monte Carlo-simulated resolution phantom (from 1.0 to 2.5 mm). For the mouse phantom experiments, PG-INR achieved up to 18-fold faster reconstruction compared to OSEM at comparable resolution. For the resolution phantom simulation, PG-INR successfully resolved 1.0 mm diameter rods with up to 4.8 dB peak signal-to-noise ratio improvement and 0.25 structural similarity index measure enhancement over OSEM. These results suggest that the PG-INR performs significantly better than standard OSEM for Ac-225 Compton imaging.

AcknowledgmentThis work is supported by the National Institutes of Health (NIH) under grant R01EB032324 and the National Research Foundation of Korea(NRF) grant funded by the Korea government(MSIT)(RS-2024-00345521).
References
[1] Thijssen, L., et al. 'Polymersomes as nano-carriers to retain harmful recoil nuclides in alpha radionuclide therapy: a feasibility study.' Radiochimica Acta 100.7 (2012): 473.
[2] De Kruijff, Robin M., Hubert T. Wolterbeek, and Antonia G. Denkova. 'A critical review of alpha radionuclide therapy—how to deal with recoiling daughters?.' Pharmaceuticals 8.2 (2015): 321-336.
[3] Fontana, Mattia, et al. 'Compton camera study for high efficiency SPECT and benchmark with Anger system.' Physics in Medicine & Biology 62.23 (2017): 8794-8812.
[4] Han, Li, et al. 'Statistical performance evaluation and comparison of a Compton medical imaging system and a collimated Anger camera for higher energy photon imaging.' Physics in Medicine & Biology 53.24 (2008): 7029-7045.
[5] Seo, Youngho. 'Quantitative imaging of alpha-emitting therapeutic radiopharmaceuticals.' Nuclear medicine and molecular imaging 53.3 (2019): 182-188.
[6] B. Das, et al. 'Compton Imaging of Ac-225 in Preclinical Phantoms With a 3D-positioning CZT Camera.' IEEE Transactions on Radiation and Plasma Medical Sciences 10.1 (2026): 112-125.
[7] J. Caravaca, et al. 'Compton and Proximity Imaging of Ac In Vivo With a CZT Gamma Camera: A Proof of Principle With Simulations.' IEEE Transactions on Radiation and Plasma Medical Sciences 6.8 (2022): 904-915.
[8] Skorokhodov, Ivan, et al. 'Adversarial generation of continuous images.' Proceedings of the IEEE/CVF conference on computer vision and pattern recognition. 2021.
[9] Xu, Xinyue, et al. 'Physics-guided Bayesian neural networks and their application in ODE problems.' Verification and Validation 87769. American Society of Mechanical Engineers, 2024.
Keywords: Compton imaging, Physics-guided implicit neural representation, Ac-225, Bio-distribution, CZT camera
10:45 MIC-11-08

Attenuation Map Estimation from NAC Brain PET Images Using a 3D Patch-Based U-Net: A Multi-Tracer Study on the NeuroEXPLORER (#1934)

M. Keppens1, G. Schramm1, H. Goesseye1, K. Van Laere1

1 KU Leuven, Department of Imaging and Pathology, Leuven, Belgium

Abstract

Attenuation correction in PET/CT imaging typically uses a CT-derived attenuation map (μ-map), prone to misalignment artifacts, CT-induced artifacts, and additional radiation dose. CT-free alternatives are therefore clinically attractive, and deep learning methods are a promising solution. As clinical PET centres increasingly adopt diverse tracer protocols beyond FDG, a single attenuation correction model that generalizes across tracers without retraining would further reduce deployment complexity. In this work, we investigate the feasibility of supervised μ-map estimation from non-attenuation-corrected (NAC) brain PET images using a 3D patch-based U-Net, trained and evaluated on patient data from the NeuroEXPLORER, a brain- dedicated PET/CT scanner. A dataset of 353 scans across 12 different tracers was used to study the effect of tracer composition on model generalizability. To our knowledge, this is the first study to systematically assess how training tracer composition affects cross-tracer generalization in deep learning-based CT- free attenuation correction, using a large multi-tracer cohort. The tuned U-Net outperformed Attention U-Net, HighResNet, and Swin UNETR under matched conditions. FDG-only training showed poor generalization to non-FDG tracers, with Normalized Root Mean Squared Error (NRMSE) on average 5× higher in the brain for non-FDG tracers than multi-tracer models across different dataset sizes. Notably, a model trained without any FDG data produced FDG μ-maps as well as a FDG-only model, suggesting the network learns anatomy-based priors that generalize across tracer distributions. Tracer diversity during training did not degrade FDG performance and improved generalization. Weighted resampling to correct FDG/non-FDG imbalance worsened performance when the non-FDG patient pool was small. These results indicate that training set diversity, rather than size or tracer-specific data, is an important driver of generalization.

References
[1] M. Jehl et al., “Beyond CT: Attenuation correction for stand-alone brain PET,” Zeitschrift f¨ur Medizinische Physik, 2026. DOI: https://doi.org/10.1016/j.zemedi.2026.02.001.
[2] J. Wasserthal et al., “TotalSegmentator: Robust segmentation of 104 anatomic structures in CT images,” Radiology: Artificial Intelligence, 2023. [Online]. Available: https://doi.org/10.1148/ryai.230024.
[3] W. Falcon and The PyTorch Lightning team, PyTorch Lightning, 2019. DOI: 10.5281/ zenodo .3828935. [Online]. Available: https: // github. com/Lightning- AI /lightning.
[4] M. J. C. et al., “Monai: An open-source framework for deep learning in healthcare,” arXiv:2211.02701, 2022.
Keywords: Attenuation Correction, Deep learning, NAC, PET, U-Net


Our Exhibitors: