NSS Lightning Talks 1

Session chair: Corbeil Therrien, Audrey, Professor (Université de Sherbrooke, Génie électrique et génie informatique, Sherbrooke, Canada); Hull, Giulia, Dr. (Université Paris-Saclay, CNRS/IN2P3, IJCLab, Laboratoire de Physique des 2 infinis Irène Joliot-Curie, Orsay, France)
 
Shortcut: N-LT-01
Date: Monday, 9 November, 2026, 12:30 - 13:00
Location: FEDERICO GARCÍA LORCA
Session type: NSS Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

12:30 N-LT-01-01

Facile, scalable and high-yield synthesis of zero-dimensional copper halide Cs3Cu2Cl5 scintillator with near-unity quantum yield for high-resolution X-ray imaging applications (#1659)

Y.S. Choi1, J. Im2, K. Heo3, S.O. Cho2, B.K. Cha4, B. Shin1

1 KAIST, Materials Science and Engineering, Daejeon, Republic of Korea
2 KAIST, Nuclear and Quantum Engineering, Daejeon, Republic of Korea
3 Viewworks, Anyang, Republic of Korea
4 KERI, Ansan, Republic of Korea

Abstract

Metal halide perovskites, particularly copper halide variants, have emerged as promising scintillators owing to their large Stokes shift, high photoluminescence quantum yield (PLQY), and efficient radioluminescence. Here, we demonstrate a dioxolane-mediated reaction synthesis as a simple, scalable, and high-yield strategy for producing Cs3Cu2Cl5 powders with near-complete conversion. By employing low-polarity yet water-miscible dioxolane as the reaction medium together with an aqueous H3PO2 additive, the solubility imbalance between the precursors inherent to low-polarity solvents is effectively addressed. This approach enables stoichiometry-controlled dissolution–precipitation under a low-polarity reaction environment and the formation of phase-pure Cs3Cu2Cl5 powders with near-unity PLQY. The powders show bright green emission at ~530 nm and retain over 80% of their initial efficiency after 300 days of ambient storage without encapsulation, demonstrating remarkable intrinsic stability. Cs3Cu2Cl5-based composite films deliver an ultrahigh light yield of ~98,000 photons MeV-1, greatly surpassing that of commercial scintillators such as Gd2O2S and CsI:Tl, and exhibiting excellent dose linearity and long-term irradiation stability. When integrated into commercial flat-panel detectors, the Cs3Cu2Cl5-based composite films successfully enabled high-quality 2D radiographic and 3D computed tomography imaging, directly verifying their compatibility with existing X-ray detection systems. This facile and efficient synthesis, together with the demonstrated device-level imaging performance, highlights Cs3Cu2Cl5 as a scalable and practical candidate for next-generation X-ray scintillators.

Keywords: halide perovskite, scintillator, Cs3CuCl5
12:32 N-LT-01-02

Hydrophobic Solvent-Based Polishing for Performance Enhancement of Water-Sensitive Perovskite Scintillator Crystals (#1236)

S. Song1, 2, J. Seo3, D. Lee1, 2, C. Park4, B. Park5, J.-Y. Yeom2, 6

1 Korea University, Department of Bioengineering, Seoul, Republic of Korea
2 Korea University, Interdisciplinary Program in Precision Public Health, Seoul, Republic of Korea
3 Korea Institute of Fusion Energy, Dajeon, Republic of Korea
4 Korea University, Global Health Technology Research Center, Seoul, Republic of Korea
5 Seoul National University, Research Institute for Future Technology and Policy, Seoul, Republic of Korea
6 Korea University, School of Bioengineering, Seoul, Republic of Korea

Abstract

Halide perovskites are promising scintillator materials for radiation detection and medical imaging because of their excellent optical and scintillation properties. Since the surface quality of single-crystal scintillators strongly affects light extraction and detector performance, polishing is an essential step in scintillator fabrication. However, conventional wet polishing processes are not suitable for water-sensitive crystals such as Cs3Cu2I5 (CCI). In this work, hydrophobic solvents were investigated as polishing media for water-sensitive CCI single crystals. Three hydrophobic solvents—squalane, silicone oil, and mineral oil— were used as dispersion media for 1 μm alumina abrasives, followed by toluene rinsing after polishing. Among them, squalane showed the best polishing performance, yielding the lowest surface roughness (Rq=17.29 nm), the highest transmittance of 78.21%, and the narrowest rocking-curve FWHM of 0.025°. In addition, sequential polishing in squalane using P2000 sandpaper, P4000 sandpaper, and 1 μm alumina enhanced the light yield and improved the energy resolution from 6.53% to 5.83%. These results identify squalane as a promising polishing medium for water-sensitive halide perovskite scintillators.

Acknowledgment

This work was supported by the National Research Foundation of Korea (NRF), funded by the Ministry of Science and ICT (RS-2023-NR077190, RS-2022-00165164), and by the National Research Foundation of Korea and the Commercializations Promotion Agency for R&D Outcomes (RS-2023-00234651).

Keywords: Perovskite Scintillator, Cs3Cu2I5, Hydrophobic Polishing, Surface Treatment
12:34 N-LT-01-03

Organic Scintillator Light Yield Models for Sub-MeV Neutrons in EJ301D and d-stilbene (#1369)

C. A. Irvine1, 2, T. C. Borgwardt1, R. A. Weldon Jr.1, J. Mattingly2

1 Los Alamos National Laboratory, NEN-2, Los Alamos, New Mexico, United States of America
2 North Carolina State University, Nuclear Engineering, Raleigh, North Carolina, United States of America

Abstract

Six commonly used models for neutron induced light yield in organic scintillators were fit and analyzed using measurements of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene). Measured neutron energies spanned 300 keV to 2200 keV for the EJ301D scintillator and 200 keV to 2500 keV in d-stilbene. The model fits and experimental analysis methods were verified by examining the agreement between the predicted light output spectrum and the measured light output spectrum for several simulated quasi-monoenergetic neutron sources. Birks model inaccurately predicted highly quenched light yield for sub-MeV neutrons in both scintillators. The addition of a second order quenching term to the Birks model by Chou significantly improved the models accuracy, however its behavior is non-physical if extrapolated beyond the measured neutron energies. The model derived by Voltz accurately fit the measurement of both scintillators for all measured neutron energies. Further investigation into the ability to extrapolate based on these semi-empiric models would be valuable given the non-physical behavior of well-fitting models.

AcknowledgmentThis work was supported by the US Department of Energy through the Los Alamos National Laboratory. Los Alamos National Laboratory is operated by Triad National Security, LLC, for the National Nuclear Security Administration of U.S. Department of Energy (Contract No. 89233218CNA000001).
References
[1] Thibault A Laplace et al. “Modeling ionization quenching in organic scintillators”. In: Materials Advances 3.14 (2022), pp. 5871–5881
[2] Mark A. Norsworthy et al. “Evaluation of neutron light output response functions in EJ-309 organic scintillators”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 842 (2017), pp. 20–27. ISSN: 0168-9002. DOI: https://doi.org/10.1016/j.nima.2016.10.035.
[3] John Betteley Birks. The theory and practice of scintillation counting: International series of monographs in electronics and instrumentation. Vol. 27. Elsevier, 2013.
[4] CN Chou. “The nature of the saturation effect of fluorescent scintillators”. In: Physical Review 87.5 (1952), p. 904.
[5] J Hong et al. “The scintillation efficiency of carbon and hydrogen recoils in an organic liquid scintillator for dark matter searches”. In: Astroparticle Physics 16.3 (2002), pp. 333–338. ISSN: 0927-6505. DOI: https://doi.org/10.1016/S09276505(01)00114-1
[6] S Yoshida et al. “Light output response of KamLAND liquid scintillator for protons and 12C nuclei”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 622.3 (2010), pp. 574–582.
[7] R. Voltz et al. “Influence of the Nature of Ionizing Particles on the Specific Luminescence of Organic Scintillators”. In: The Journal of Chemical Physics 45.9 (Nov. 1966), pp. 3306–3311. ISSN: 0021-9606. DOI: 10.1063/1.1728106. eprint: https://pubs.aip.org/aip/jcp/article-pdf/45/9/3306/18846420/3306 1 online.pd
[9] G. Dietze and H. Klein. “Gamma-calibration of NE213 scintillation counters”. In: Nucl. Instr. and Meth. 193.3 (1982), pp. 549–556. ISSN: 0167-5087. DOI: 10.1016/0029-554X(82)90249-X.
[11] C. A. Irvine et al. “Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods”. In: Submitted for review (2026).
Keywords: Organic Scintillators, Deuterated Scintillators, EJ301D, d-stilbene, Light Output Model
12:36 N-LT-01-04

Application of neutron sensitising layers to plastic scintillator (#2414)

J. R. Hitchens1, C. Allwork1, S. L. Chauhan1, T. Crane1, T. Heather1, M. P. Taggart1

1 AWE Nuclear Security Technologies, Reading, United Kingdom

Abstract

Eljen plastic scintillator disks have been coated with layers of neutron sensitiser in a systematic study on the thickness of neutron detection layers. Here we discuss the impact of enhancing standard plastic scintillator (PVT) with coatings containing both lithium and boron isotopes. The application of these layers enhances the material to provide a mechanism for detecting neutron radiation. A systematic study was performed to assess the impact of sensitiser thickness on neutron detection efficiency and neutron-gamma pulse shape discrimination (PSD) performance. Samples were exposed to the mixed radiation fields of a 252Cf source, and a sample of plutonium. The results demonstrate clear neutron-gamma discrimination in sensitised samples, with measured figures of merit in excess of 3 recorded for optimised lithium-rich coatings. This is comparable performance to established dual-mode detectors. These findings show that thin, externally applied neutron-sensitising layers provide an effective route to enhancing the performance of conventional plastic scintillators. This approach may offer a low-cost means of upgrading existing detector systems in nuclear security applications.

References
[1] J. Glodo, et al., “Selected Properties of Cs2LiYCl6:Ce3+ Scintillator,” IEEE Trans. Nucl. Sci., vol. 56, pp. 873–880, 2009.
[2] R. Song, et al., “The Neutron-Gamma Pulse Shape Discrimination of CLLB Detector,” EPJ Web of Conferences, vol. 295, Art. No. 09031, 2024
[3] N. Zaitseva, et al., “Plastic scintillators with efficient neutron-gamma pulse shape discrimination,” Nuclear Instruments and Methods in Physics Research A, vol. 668, pp. 88-93, 2012
[4] R. Breuckers, C. Bartle and A. Edgar, "Transparent lithium loaded plastic scintillators for thermal neutron detection," Nuclear Instruments and Methods in Physics Research A, vol. 701, pp. 58-61, 2013
[5] I. Pawelczak, et al., “Boron-loaded plastic scintillators with neutron-γ discrimination capability,” Nuclear Instruments and Methods in Physics Research A, vol. 751, pp. 62-69, 2014
[6] N. Cherepy, et al., “Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection,” Nuclear Instruments and Methods in Physics Research A, vol. 778, pp. 126-132, 2015
Keywords: Boron coated plastic scintillator, Lithium coated plastic scintillator, Neutron detection, Nuclear security, Pulse shape discrimination
12:38 N-LT-01-05

Scintillation light quenching for energetic charged particles in GAGG:Ce (#1607)

F. Liang1, N. Floyd1, H. Jayatissa1, P. Adsley2, A. Alvarez2, R. Bartsch2, S. Fritz2, T. Hankins2, B. Harvey2, K. Pham2, E. Schnorrenberg2, D. Shelden2, S. Yennello2

1 Los Alamos National Laboratory, ISR Division, Los Alamos, New Mexico, United States of America
2 Texas A&M University, Cyclotron Institute, College Station, Texas, United States of America

Abstract

Cerium-doped gadolinium gallium aluminium garnet (GAGG:Ce) is a novel scintillator with excellent scintillation properties. It is suitable for use in various basic science research and applications. Because the scintillation light is quenched for charged particle detection, it is necessary to use beams from accelerators to calibrate the energy response. Measurements of energetic charged particles incident on three GAGG:Ce crystals were performed using accelerated protons, 4He, and 12C at 0oC and 20oC in consideration for detecting charged particles in the earth's radiation belts for space weather modeling and for deploying in dosimetry devices in ion therapy, respectively. The Birks factor which quantitatively describes the extent of quenching was deduced from the experimental data. For all three GAGG:Ce scintillators, the Birks factor decreases with the atomic number Z of the incident ions. Furthermore, less light quenching, a smaller Birks factor, was observed for GAGG:Ce at 0oC. The quenching for the Mg-codoped GAGG:Ce which has a shorter decay time constant, was found to be less temperature dependent compared to the other two GAGG:Ce crystals.

AcknowledgmentLos Alamos National Laboratory is managed by Triad National Security, LLC for the U.S. Department of Energy's NNSA.
References
[1] Wang, YQ, Burward-Hoy, JM, Tesmer, JR 2014, 'Production of high energy and low flux protons using 2D(3He,p)4He for space detector calibrations', Nucl. Instrum. Methods, vol. B332, pp. 432-438.
[2] Espinoza, TN, et al. 2024, 'Proton quenching in rare-earth inorganic scintillators: GAGG:Ce and YSO:Ce', IEEE Trans. Nucl. Sci., vol. 71, pp. 2102-2108.
[3] Birks, JB 1964, 'The theory and practice of scintillation counting', Pergamon Press, Oxford.
[4] Treytak, VI 2010, 'Semi-empirical calculation of quenching factors for ions in scintillators', Astro. Phys., vol. 33, pp. 40-53.
[5] Ziegler, JF, Biersack, JP, Littmark, U 1985, 'The stopping and range of ions in solids', vol. 1, Pergamon Press, New York.
[6] Berger, MJ, Coursey, JS, Zucker, MA, Chang, J 2017, 'Stopping-power & range tables for electrons, protons and helium ions', https://dx.doi.org/10.18434/T4NC7P.
Keywords: Cerium-doped gadolinium gallium aluminium garnet, scintillation quenching, Birks factor, accelerated ion beam
12:40 N-LT-01-06

Temperature Dependence of Pulse Shape Discrimination in SiPM-Based EJ-276D Detectors (#1585)

J. W. Fritchie1, A. Di Fulvio1, G. Gariazzo1, G. Roche1

1 University of Illinois Urbana-Champaign, Nuclear, Plasma, and Radiological Engineering, Urbana, Illinois, United States of America

Abstract

The temperature dependence of pulse shape discrimination performance was investigated for three commercial silicon photomultiplier technologies coupled to an EJ-276D organic scintillator. Measurements were conducted at 22 °C, 30 °C, 40 °C, and 50 °C using PuBe sources. Pulse shape discrimination was quantified using the tail-to-total ratio and figure of merit. For all devices, the figure of merit increased at 30 °C. The Broadcom device exhibited the highest performance, increasing from 1.12 at 22 °C to a maximum of 1.17 at 30 °C before decreasing to 0.76 at 50 °C. The Onsemi and Hamamatsu devices showed smaller improvements, with figure of merit values increasing from 0.86 to 0.89 and 0.84 to 0.90, respectively, between 22 °C and 30 °C. At 50 °C, all devices exhibited reduced performance due to increased silicon photomultiplier thermal noise. Temperature-dependent changes in pulse shape were observed, with increasing temperature producing faster decay and modifying the balance of prompt and delayed scintillation light, improving neutron-gamma separation at intermediate temperatures. Despite degradation at higher temperature, all devices maintained effective discrimination up to 50 °C. These results demonstrate that silicon photomultiplier-based detectors are capable of robust neutron-gamma discrimination at elevated temperatures relevant to safeguards applications.

AcknowledgmentThis work is funded in-part by Sandia National Laboratories (SNL) LDRD Award 2308289. SNL is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration (NNSA) under contract DE-NA0003525. This research was performed under appointment to the Nuclear Nonproliferation International Safeguards Fellowship Program sponsored by the U.S. NNSA's Office of International Nuclear Safeguards.
References
[1] Acerbi, Fabio, Gundacker, Stefan 2019, 'Understanding and Simulating SiPMs', Nulcear Insturments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 926, 16-35
[2] Borgwardt, TC, Oukrop, L, Bartlett, KD, Smith, K, Williamson, E, Meierbachtol, KC, Febbraro, M 2025, ‘Temperature dependence of the nspec fieldable neutron spectrometer’, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1072, article 170161.
[3] Arrue, J, Chandler, C, Duce, M, Lim, A, Sellinger, A, Erickson, A 2023, ‘Impact of temperature on light yield and pulse shape discrimination of polysiloxane-based organic scintillators formulated with commercial resins’, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1056, article 168650.
Keywords: Silicon photomultipliers, pulse shape discrimination, radiation detection, organic scintillators, temperature dependence
12:42 N-LT-01-07

Performance evaluation of GaGG(Ce) scintillators with different photosensors (#2850)

M. Caballero Rodríguez1, N. Bernier1, V. M. Nouvilas1, L. Fraile2, 1, O. Alonso-Sañudo1, J. A. Briz1, S. Gaitan1, G. G. de Lorenzo1, P. Gonzalez-Tarrio1, A. Illana3, J. Udias1

1 Universidad Complutense de Madrid, Facultad de Ciencias Físicas / Departamento de Estructura de la Materia, Física Térmica y Electrónica, Madrid, Spain
2 CERN, ISOLDE, EP Department, Geneva, Spain
3 CSIC, Instituto de Estructura de la Materia, Madrid, Spain

Abstract

The HIE-ISOLDE Timing Array for Reaction Studies (HISTARS) project at CERN is developing a specialized detector system designed to measure the lifetimes of excited nuclear states. For efficient particle detection, thin square GaGG(Ce) are utilized alongside YSO due to their high density and fast scintillation properties. This work evaluates the performance of GAGG(Ce) crystals coupled with two distinct photosensors: a Hamamatsu R9779 photomultiplier tube (PMT) and an array of four silicon photomultipliers (SiPM) using a custom-designed circuit. These configurations were tested in combination with a LaBr3(Ce) detector to facilitate coincidence measurements. Data acquisition was performed using high-speed digitizer to extract timing and energy information. This article reports on the comparative performance of both readout methods, specifically characterizing pulse shape discrimination capabilities, energy resolution, and the coincidence time resolution for alpha-gamma events. Although the energy resolution is acceptable and it has a good pulse shape discrimination capability, the measured timing limitations show that the current configuration is not ideal for the HISTARS array. These results will guide the selection of better-suited materials for high-precision timing at HIE-ISOLDE.

AcknowledgmentThis work has been supported by the Spanish Ministerio de Ciencia e Innovaci\'on under projects PID2019-104714GB-C21 and PID2022-140400NB-C21.
References
[1] Wang, Z, Guo, H, Qian, S 2020, ‘Pulse shape discrimination of GAGG:Ce crystals for charged particle detection’, Journal of Instrumentation, Vol. 15, p. C06031, Bristol: IOP Publishing.
[2] Tsuchida, N, Ikeda, M, Kamae, T 1997, ‘A study of the GAGG:Ce crystal for its application in nuclear physics’, Nuclear Instruments and Methods in Physics Research Section A, Vol. 385, pp. 290–298, Amsterdam: Elsevier.
[3] Vedia, V, Carmona-Gallardo, M, Fraile, LM 2017, ‘Characterization of specialized LaBr3(Ce) detectors for fast-timing lifetime measurements’, Nuclear Instruments and Methods in Physics Research Section A, Vol. 857, pp. 98–105, Amsterdam: Elsevier
Keywords: GAGG(Ce) scintillator, pulse shape discrimination, photomultiplier tube, silicon photomultipliers, timing resolution
12:44 N-LT-01-08

Combining cross-luminescent scintillators and μSiPMs for better timing in ToF-PET (#1249)

K. Herweg1, 2, S. Bisi3, C. Bruschini3, E. Charbon3, A. Gola4, L. Parellada-Monreal4, M. Penna4, D. Schug1, 2, V. Schulz2, S. Gundacker5

1 RWTH Aachen University, University Hospital RWTH Aachen, Aachen, Germany
2 RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen, Germany
3 Ecole polythechnique fédérale de Lausanne, Advanced Quantum Architecture Laboratory, Neuchatel, Switzerland
4 Fondazione Bruno Kessler, Trento, Italy
5 Austrian Academy of Sciences, Marietta Blau Institute for Particle Physics, Vienna, Austria

Abstract

Time-of-flight positron emission tomography (ToF-PET) has boosted PET image quality significantly in the last years. During its first inception it was built with cross-luminescent BaF2 crystals, which have since been replaced by LYSO. Recently, cross-luminescence has regained popularity with new scintillators being developed. However, BaF2 and the recently developed Cs2ZnCl4 could not improve on the LYSO state-of-the-art coincidence time resolution (CTR) (56 ps for 2x2x3 mm³ and 95 ps for 3x3x19 mm³). As Cs2ZnCl4 shows a significant Cherenkov production, we combined it with the DIGILOG approach to boost its timing performance. The DIGILOG approach segments the sensor into μSiPMs and has shown an improved timing performance for BGO due to its Cherenkov radiation and an improved SPTR. Here, we simulated a 3x3x3 mm³ and a 3x3x20 mm³ Cs2ZnCl4 crystal coupled to seven different μSiPM arrays. The simulation included noise factors like dark counts, cross-talk, SPAD dead time and analog noise. It was designed with a PDE of 60 % and an SPTR of 25 ps. This resulted in an improved CTR of 34+/-4 ps for an array of 20x20 μSiPMs coupled to a 3x3x3 mm³ Cs2ZnCl4 crystal compared to the non-segmented SiPM at 48+/-3 ps. Furthermore, for the 3x3x20 mm³ crystal, a CTR of 64+/-4 ps was reached with a 10x10 μSiPM array, while the non-segmented SiPM showed a CTR of 84+/-3 ps. The results of the segmented SiPMs improve on the LYSO state-of-the-art. Additionally, they demonstrate that the DIGILOG SiPM approach improves timing performance not just for BGO, but also for other scintillators with high Cherenkov yield, ultra-fast emission and low light yield. We also provide motivation to optimize sensors for Cs2ZnCl4, which could enable better timing performance than the LYSO state-of-the-art.

AcknowledgmentThis research is funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - 500540345 and the Swiss National Science Foundation (SNSF) - #200021L_208073.
References
[1] Wong, W. H. et al. 1984, 'Characteristics of small barium fluoride (BaF2) scintillator for high intrinsic resolution time-of-flight positron emission tomography', IEEE TNS
[2] Herweg, K. et al. 2023, 'On the Prospects of BaF2 as a Fast Scintillator for Time-of-Flight Positron Emission Tomography Systems', IEEE TRPMS
[3] Rutstrom, D. et al. 2022, 'Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs2ZnCl4 and Cs3ZnCl5', Optical Materials
[4] Herweg, K. et al. 2024, 'Timing limits of ultrafast cross-luminescence emission in CsZnCl-based crystals for TOF-CT and TOF-PET', EJNMMI Physics
[5] Nadig, V. et al. 2023, 'Timing advances of commercial divalent-ion co- doped LYSO:Ce and SiPMs in sub-100 ps time-of-flight positron emission tomography', PMB
[6] Gundacker, S. et al. 2023, 'DIGILOG: A digital-analog SiPM towards 10 ps prompt-photon tagging in TOF-PET', 2023 IEEE NSS MIC RTSD
[7] Herweg, K. et al. 2024, 'Investigating μSiPMs to overcome the limits of BGO in ToF-PET', 2024 IEEE NSS MIC RTSD
[8] Herweg, K. et al. 2026, 'Exploring μSiPMs with BGO for Cherenkov time-of-flight in PET', revision submitted to IEEE TRPMS
[9] Zuo, X. et al. 2025, 'Scintillation performance of 1-inch-diameter Cs2ZnCl4 crystals', CrystEngComm
Keywords: ToF-PET, sensor segmentation, Cherenkov, CsZnCl, cross-luminescence
12:46 N-LT-01-09

Fast or Adapt: Proportional Gas in γ-ray Fields (#1278)

J. Prchlik1, E. Yokie1, A. Petitjean1, D. O'Connor1

1 Reuter-Stokes, LLC, Twinsburg, Ohio, United States of America

Abstract

Background γ-ray fields complicate neutron measurements for Nondestructive Assay (NDA) of Nuclear Materials and the next generation of advanced reactor designs, including non-light water (non-LWR) and Small Modular Reactors (SMRs). Neutron sensitive proportional counter design for high γ-ray fields often focus on optimizing ion collection time and integrating low-Z materials. In these counters, the metal cathode produces most of the Compton scattered electrons, which deposit unwanted energy and signal in the gas. The long path length for Compton electrons in the counter gas means the counter gas pressures may be optimized to increase the ratio of ion-to-electron energy deposition. Here we present gas mixture and pressure optimization for ion-to-electron energy deposition using SRIM simulations. The simulation output is then tested experimentally for its effect on neutron sensitivity in γ-ray fields between 1 R/Hr and 100 R/Hr. The ion-to-electron energy deposition ratio shows promise as an additional design consideration for neutron sensitive proportional counters in γ-ray fields, even though the experimentally measured optimum pressure of 0.5 atm for He/N2 95/5 is lower than the simulated optimum pressure. Future experiments with a current sensitive preamplifier (CAEN A1427) will improve neutron counting for 1 to 100 R/Hr γ-ray fields.

References
[1] DH Beddingfield, NH Johnson, and HO Menlove. 3he neutron proportional counter performance in high gamma-ray dose environments. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 455(3):670–682, 2000.
[2] D. C. Henzlova, M. P. Baker, K. Bartlett, A. Favalli, M. Iliev, M. A. Root, S. Sarnoski, T. Shin, and M. T. Swinhoe. Neutron Detectors, pages 325–358. Springer Nature Switzerland, Cham, 2024.
[3] Kevin S McKinny, Thomas R Anderson, and Nathan H Johnson. Neutron detector sensitivity measurements and their variation. In 2011 IEEE Nuclear Science Symposium Conference Record, pages 533–537. IEEE, 2011.
[4] J. Va’Vra. Review of wire chamber aging. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 252(2):547–563, 1986.
Keywords: Gamma-ray effects, Reactor instrumentation, Radiation monitoring, Nuclear instrumentation, Gaseous detectors
12:48 N-LT-01-10

Characterisation of edge-on fully-depleted monolithic CMOS silicon sensors (#1882)

M. Barbagiovanni1, 2, A. Bjorklid3, A. Bortone2, R. Brunskog6, M. Da Rocha Rolo2, M. Danielsson6, A. Elihar3, U. Follo2, S. Garbolino2, J. Hartman4, J. Herzen7, D. John7, F. L. Klaus7, C. Mogler7, L. Pancheri5, J. Parnell7, 6, M. Persson6, E. Posteraro1, 2, M. Sjolin3, M. Y. Tamm6, S. Wirtensohn7

1 Politecnico di Torino, Electronics and Telecommunications, Turin, Italy
2 INFN Sezione Torino, Turin, Italy
3 Prismatic Sensor, Stockholm, Sweden
4 Karolinska Institutet, Stockholm, Sweden
5 Università di Trento, Trento, Italy
6 KTH Royal Institute of Technology, Stockholm, Sweden
7 TUM, Munich, Germany

On behalf of 1MICRON Collaboration

Abstract

Monolithic silicon CMOS Sensors represent a considerable step forward in charged particle and photon sensing, and emerge as a promising embodiment for the design of novel deep-silicon photon-counting X-ray Computed Tomography scanners . This work presents the first characterization of the ARCADIA MD3 Fully-Depleted CMOS sensors, which technology is currently the baseline for the development of innovative sensors under the framework of the EIC Pathfinder Open 1MICRON project. We report on the characterisation results using an edge-on geometry and a focused synchrotron X-ray beam at the DESY test facility. The x-rays impinge on the edge of the sensor, increasing the active sensor depth seen by the photons, which consequently improves the quantum efficiency with respect to a face-on configuration. A 37 keV focused beam incident parallel to the sensor surface allowed scans along the two directions of the sensor edge, enabling the extraction of the active sensor thickness and mechanical tilt via pixel intensity profiles. Lateral scans across pixel boundaries revealed a periodicity of the spatial modulation of mean cluster size compatible with the pixel pitch of the matrix. Taking the cluster size as the main figure of merit, the performance of the sensor was evaluated at different thresholds and multiple bias voltages in order to assess the variation in the Coulomb cone and collection dynamic. The measurements are supported by Allpix Squared Monte Carlo framework, demonstrating good consistency between the simulated and the real domain.

AcknowledgmentThis study was carried out with support from the INFN CSN5 Call ARCADIA. This work was supported by the European Union’s Horizon Europe research and innovation programme under the 1MICRON project – “New Technology for 1 MICRON Resolution Biomedical Imaging” (grant agreement No. 101186826).
References
[1] Da Rocha Rolo, Manuel 2025 'Arcadia fully depleted cmos maps development
with lfoundry 110 nm cis', Frontiers in Sensors, vol. Volume 6 - 2025
[2] Bergamaschi, A., 2005, 'Edge on silicon microstrip detectors for medical
imaging', Nuclear Instruments and Methods in Physics Research Section
A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.
549, no. 1, pp. 199–204, Sep. 2005
Keywords: Monolithic CMOS Silicon Sensor, Deep-silicon, X-ray imaging, Clinical CT
12:50 N-LT-01-11

Gain suppression study on LGADs with different gain layer designs (#2025)

L. Cavazzini1, 2, A. Bisht1, M. Boscardin1, M. Centis Vignali1, M. Fernandez Garcia3, F. Ficorella1, O. Hammad Alì1, V. Kraus4, M. Moll5, G. Paternoster1, M. Wiehe5

1 Fondazione Bruno Kessler, Trento, Italy
2 University of Trento, Department of Physics, Trento, Italy
3 Instituto de Fisica de Cantabria, IFCA, Santander, Spain
4 TU Wien, Faculty of Physics,, Vienna, Austria
5 CERN, Geneva, Switzerland

Abstract

High-energy physics experiments currently use Low Gain Avalanche Diodes (LGADs) as part of their time-of-flight layers to track particles, thanks to their unique temporal resolution and radiation hardness. With increasing deposited charge, the gain was observed to decrease. This gain suppression effect originates from the electrostatic field screening produced by the avalanche multiplication charge. This work investigates the resilience of the LGADs to the gain suppression by characterizing a set of detectors with different gain layer designs and thicknesses, using Transient Current Techniques.

References
[1] G. Pellegrini et al. “Technology developments and first measurements of Low Gain Avalanche Detectors (LGAD) for high energy physics applications”. In: Nucl. Instrum. Meth. A.765 (2014), pp. 12–16. DOI: https://www.doi.org/10.1016/j.nima.2014.06.008.
[2] N. Cartiglia et al. “Beam test results of a 16 ps timing system based on ultra-fast silicon detectors”. In: Nucl. Instrum. Meth. A.850 (2017), pp. 83–88. DOI: https://www.doi.org/10.1016/j.nima.2017.01.021.
[3] E. Curras et al. “Gain reduction mechanism observed in Low Gain Avalanche Diodes”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1031 (May 2022), p. 166530. ISSN: 0168-9002. DOI: http://www.doi.org/10.1016/j.nima.2022.166530.
[4] Sebastian Pape et al. “TCAD Simulation of Two Photon Absorption—Transient Current Technique Measurements on Silicon Detectors and LGADs”. In: Sensors 24.24 (2024). ISSN: 1424-8220. DOI: https://doi.org/10.3390/s24248032.
Keywords: Detectors, Silicon, LGAD, Timing, GainSuppression
12:52 N-LT-01-12

Pulse-Shape-Based Slow-Rising Pulse Rejection for Reliable Charge-Carrier Transport Characterization in a Semiconductor Radiation Detector (#2231)

J. Boo1, B. Park2, G. Kim1, 3

1 Seoul National University, Department of Energy Systems Engineering, Seoul, Republic of Korea
2 Seoul National University, Nuclear Research Institute for Future Technology and Policy (NIFTEP), Seoul, Republic of Korea
3 Seoul National University, Nuclear Engineering Department, Seoul, Republic of Korea

Abstract

Mobility (μ), lifetime (τ), and mobility–lifetime product (μτ) are key metrics for semiconductor radiation detectors. Highly concentrated trapping centers or defects can distort the internal electric-field distribution, producing reduced-amplitude slow-rising charge-sensitive preamplifier pulses that degrade carrier-transit and charge-collection analyses. Although slow-rising-pulse rejection is commonly used to sharpen pulse-amplitude peaks and suppress low-amplitude tails, this work extends its use to charge-carrier transport characterization. A CdZnTeSe detector [1, 2] was characterized at room temperature under electron- and hole-transit-dominant conditions using ²⁴¹Am alpha irradiation. Pulse-shape analysis rejected slow-rising pulses for key metrics extraction. In electron-transit-dominant measurements, the fast-rising pulse events preserved the bias-dependent peak-centroid trend and yielded (μτ)e = 5.7 × 10⁻⁴ cm²/V, μe = 576 cm²/V·s, and τe = 1.0 μs, consistent with reported values [3,4]. For hole-transit-dominant measurements, all-pulse events obscured the pulse-amplitude peak and hindered Hecht fitting. After rejection, we obtained (μτ)h = 2.1 × 10⁻⁴ cm²/V, τh = 0.7 μs, comparable to reported values [5], with μh = 318 cm²/V·s. Using the rise-time peak as the representative transit time, both all-pulse and fast-rising-pulse events yielded similar μh values. However, when the median rise time of all-pulse events was used instead, drift velocity did not show a clear linear dependence on electric field, whereas fast-rising-pulse events retained linearity. This reflects the need for careful consideration of slow-rising components and the transit-time definition. These results show that slow-rising-pulse rejection enables reliable transport characterization beyond spectral improvement.

AcknowledgmentThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (Ministry of Science and ICT) (No. 2022M2D2A1A02063826).
References
[1] Park, B., et al. 2022, 'Bandgap engineering of Cd1−xZnxTe1−ySey (0< x< 0.27, 0< y< 0.026)', Nucl. Instrum. Methods Phys. Res. A. 1036, 166836.
[2] Park, B., et al. 2024 'Fabrication and Evaluation of Spectroscopic Grade Quasi-hemispherical CdZnTe Detector', J. Radiat. Prot. Res. 49(2), 85-90.
[3] Kleppinger, J.W., et al. 2021, 'Growth of Cd0.9Zn0.1Te1–ySey single crystals for room-temperature gamma ray detection, IEEE Trans. Nucl. Sci. 68(9), 2429-2434.
[4] Chaudhuri, S.K., et al. 2021, 'Quaternary semiconductor Cd1−xZnxTe1−ySey for high-resolution, room-temperature gamma-ray detection', Crystals 11(7), 827.
[5] Pipek, J., et al. 2021, 'Charge transport and space-charge formation in Cd1−xZnxTe1−ySey radiation detectors', Phys. Rev. Appl. 15(5) 054058.
Keywords: Semiconductor radiation detector, Charge-carrier transport characterization, Charge-sensitive preamplifier waveform, Pulse-shape discrimination, Slow-rising pulse rejection
12:54 N-LT-01-13

Repairing Proton Radiation Damage on n-type, Cross-Strip Germanium Detectors (#1121)

S. E. Haight1, J. Roberts1, S. Boggs1, S. Pike1, J. Gerber1, E. Broadbent1, J. Tomsick2, J. Szornel4, A. Shih3, A. Valluvan1, A. Zoglauer2

1 University of California San Diego, Department of Astronomy and Astrophysics, La Jolla, California, United States of America
2 University of California Berkeley, Space Sciences Laboratory, Berkeley, California, United States of America
3 NASA, Goddard Space Flight Center, Greenbelt, Maryland, United States of America
4 Lawrence Berkeley National Laboratory, Berkeley, California, United States of America

Abstract

We performed a high-energy proton irradiation on a cross-strip germanium detector with the goals of measuring the subsequent loss to detector spectral resolution and characterizing the effectiveness of high-temperature annealing in repairing radiation damage. This work aims to address the expected radiation damage to the Compton Spectrometer and Imager (COSI) during two-year primary mission in low-Earth orbit and evaluate methods for maintenance of spectral resolution. COSI's cross-strip germanium detectors are susceptible to damage induced by the space radiation environment. Negatively charged dislocations induced by high-energy protons trap charge carriers as they drift in the applied bias voltage. The result is a degraded hole-collection signal characterized by widened spectral lines and loss to detector spectral resolution. We irradiated a non-flight detector with a fluence of 1.1 • 107 p+/cm2 — COSI's expected exposure over prime mission (95% confidence level). After irradiation, we executed a series of high-temperature anneals aimed at physically repairing the damaged germanium. We track spectral resolution by measuring the full width half maximum (FWHM) of the 662 keV spectral line emitted by the isotope Cesium-137. We repaired widened FWHMs through high-temperature annealing to within 12% of its preradiation value, repairing to 2.97 keV compared to the original 2.67 keV. We track spectral resolution across annealing processes and characterize a timescale for repair. We find the anneal time needed to repair damage from COSI's primary mission within 1% of the spectral broadening from residual damage. We project the repair time required at 90°C to be 54 +/- 10 hours.

AcknowledgmentThis work was supported by the NASA Astrophysics Research and Analysis (APRA) program, grant 80NSSC22K1881. The Compton Spectrometer and Imager is a NASA Explorer project led by the University of California, Berkeley with funding from NASA, United States under contract 80GSFC21C0059.
References
[1] J. Tomsick, S. Boggs, A. Zoglauer, D. Hartmann, M. Ajello, E. Burns, et al., The Compton Spectrometer and Imager, Proc. ICRC2023, vol. 444, 2023, p. 745.
[2] L. S. Darken, R. C. Trammell, T. W. Raudorf, R. H. Pehl, and J. H. Elliott, "Mechanism for fast neutron damage of Ge(HP) detectors," NuclearInstruments and Methods, vol. 171, no. 1, pp. 49–59, 1980.
[3] J. Beechert, H. Lazar, S. E. Boggs, T. J. Brandt, Y.-C. Chang, C.-Y. Chu, H. Gulick, C. Kierans, A. Lowell, N. Pellegrini, J. M. Roberts, T. Siegert, C. Sleator, J. A. Tomsick, and A. Zoglauer, "Calibrations of the Compton Spectrometer and Imager," Nuclear Instruments and Methods in Physics Research A, vol. 1031, p. 166510, May 2022.
[4] S. E. Haight, S. E. Boggs, G. Brewster, S. N. Pike, J. M. Roberts, A. Y.Shih, J. M. Szornel, J. A. Tomsick, A. B. Valluvan, and A. Zoglauer, "Proton radiation damage and annealing of COSI p-type cross-strip hpge detectors," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.1077, p. 170538, 2025.
[5] J. Ripa, G. Dilillo, R. Campana, and G. Galgoczi, "A comparison of trapped particle models in low earth orbit," in Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray, Eds. SPIE, Dec. 2020.
[6] M. Koenen, J. Bruckner, M. Korfer, I. Taylor, and H. Wankel, "Radiation damage in large-volume n- and p-type high-purity germanium detectors irradiated by 1.5 GeV protons," in Proceedings of 1994 IEEE Nuclear Science Symposium - NSS’94 vol. 1, 1994, pp. 201–205 vol.1.
Keywords: gamma-ray detector, anneal, radiation damage
12:56 N-LT-01-14

Diagnosing Mechanisms for Charged Particle Attenuation Enhancement in Nanostructured Materials (#1508)

N. P. Speck1, G. J. Grey2, D. A. Vecchio1, K. A. Cotterill1, A. I. Taub2, M. D. Hammig1

1 University of Michigan, Nuclear Engineering and Radiological Sciences Department, Ann Arbor, Michigan, United States of America
2 University of Michigan, Materials Science and Engineering Department, Ann Arbor, Michigan, United States of America

Abstract

This paper presents a methodology for measuring the trajectories of high-energy electrons through materials utilizing a transmission electron microscope (TEM). This novel technique is implemented to diagnose and quantify the mechanism for enhanced radiation attenuation via nanostructures. Rather than an imaging technique, the TEM is applied to radiation shielding measurements as an adaptable electron source with functionality for various beam energies, amperage, alignments, and exposure times alongside an array of precise electron detectors. By utilizing energy filtering and direct electron detection capabilities, scattering profiles are measured with minimal background contributions. This TEM method is leveraged to describe particle transport in nanostructures. Palladium nanoparticles at various monodisperse sizes are synthesized via heat injection and deposited into an epoxy matrix. The palladium epoxy nanocomposites are sectioned with an ultramicrotome to thicknesses of 70 to 1000 nm containing nanoparticle sizes of 5 to 50 nm at 20% of the total weight fraction. Scattering profile measurements at various beam energies are conducted with a variety of sample thicknesses, nanoparticle sizes, and composite fractions. Scattering profile measurements also include bulk, homogeneous palladium samples in contrast to nanomaterials composed of identical atomic percentages. Simulation of the experimental scattering profiles demonstrate an understanding for the phenomena behind nanostructured attenuation enhancement, bolstering advanced nuclear technology via a foundational description for particle transport in nanostructures.

AcknowledgmentThe authors acknowledge the financial support of the University of Michigan College of Engineering and technical support from the Michigan Center for Materials Characterization and Michigan Medicine Microscopy Core. Thank you to Tao Ma for guidance on operating the TFS Spectra 300 TEM and Megan Bennett for support on ultramicrotome sample preparation. 
References
[1] S. A. Thibeault, J. H. Kang, G. Sauti, C. Park, C. C. Fay, and G. C. King, “Nanomaterials for radiation shielding,” MRS Bulletin, vol. 40, no. 10, pp. 836--841, Oct. 2015, doi: 10.1557/mrs.2015.225.
[2] A. Rosh-Gorsky et al., “3D Printing of Composite Radiation Shielding for Broad Spectrum Protection of Electronic Systems,” Advanced Materials, vol. 36, no. 33, p. e2403822, 2024, doi: 10.1002/adma.202403822.
[3] M. Steffens et al., “Characterization of Novel Lightweight Radiation Shielding Materials for Space Applications,” IEEE Transactions on Nuclear Science, vol. 64, no. 8, pp. 2325--2332, Aug. 2017, doi: 10.1109/TNS.2017.2703312.
[4] A. Hamisu et al., “The use of nanomaterial polymeric materials as ionizing radiation shields,” Radiation Physics and Chemistry, vol. 216, p. 111448, Mar. 2024, doi: 10.1016/j.radphyschem.2023.111448.
[5] P. Hosemann, E. Stergar, A. T. Nelson et al., “Nanostructured Engineering Alloys for Nuclear Application,” MRS Online Proceedings Library, vol. 1298, pp. 217--226, 2011.
[6] V.-D. Le et al., “X-ray and gamma-ray Sensing from Aqueous-Based Lead Sulfide Telluride Nanocomposites,” Small, vol. 21, 2025.
[7] A. Curtis et al., “Micro-scale fusion in dense relativistic nanowire array plasmas,” Nature Communications, vol. 9, p. 1077, 2018, doi: 10.1038/s41467-018-03466-7.
Keywords: TEM, Radiation Shielding, Attenuation, Nanoparticles, Nanomaterials
12:58 N-LT-01-15

Monolithic integration of cooling microchannels in all-silicon ladders for vertex detectors (#1940)

J. Fernández-Tejero1, A. Dias1, M. Duch1, R. Mas1, C. Orero2, M. Vos2, M. Ullán1

1 Centro Nacional de Microelectrónica (IMB-CNM, CSIC), Cerdanyola del Vallés, Spain
2 Instituto de Física Corpuscular (IFIC, CSIC), Paterna, Spain

Abstract

New generation of vertex detectors must have excellent thermo-mechanical stability, and all-silicon ladders are considered as promising solutions for future detectors. However, power consumption asymmetries between the active area and periphery can induce large temperature gradients, and in some cases a combination of air and liquid cooling will be required to achieve homogeneous thermal profiles. Microchannel cooling offers a competitive alternative to traditional cooling systems. The short thermal path between the heat load and sink gives an increased thermal evacuation performance, combined with the reduced material needed for the integrated microchannels and the reduced Coefficient of Thermal Expansion mismatch between the cooling and sensor materials to obtain an optimized cooling for radiation detectors. The development of the technology needed for the integration of the sensor with the microchannels in a single piece is an ambitious challenge, as the conditions for the microchannel formation must be compatible with the sensor, requiring the optimization of the fabrication to ensure the compatibility with CMOS processes. As a demonstrator, all-silicon ladder prototypes with integrated cooling microchannels are presented. Power consumptions for the active area and periphery of the ladders are emulated using integrated aluminum heaters. The bulk in the active area is thinned from 600 to 50 microns, and the design of the microchannels cooling circuit, integrated in the periphery of the ladder, is optimized using finite-element simulation packages. Variations of prototype ladders with different sizes, microchannel dimensions, and integrated using different wafer bonding techniques are fabricated and evaluated in detail in this work.

AcknowledgmentThis work has received funding from the postdoctoral fellowships programme Beatriu de Pinós (Marie Skłodowska-Curie grant No 801370), and Spanish R&D grant PID2024-156645NB-C22 funded by MICIU/AEI/ 10.13039/501100011033 and by ERDF/EU.
References
[1] de Aguiar Francisco OA, Buytaert J, Collins P, et al., 'Evaporative CO2 microchannel cooling for the LHCb VELO pixel upgrade', Journal of Instrumentation, 10 (2015) C05014
[2] Andricek L, Boronat M, Fuster F, et al., 'Integrated cooling channels in position-sensitive silicon detectors', Journal of Instrumentation, 11 (2016) P06018
[3] Vos M, 'Micro-channel cooling in high energy physics', Proceedings of science, 287 (2016) 037
[4] Flaschel N, Ariza D, Díez S, et al., 'Thermal and hydrodynamic studies for micro-channel cooling for large area silicon sensors in high energy physics experiments', Nuclear Instruments and Methods A, 863 (2017) 26-34
[5] Ullán M, Correa J, Dauderys V, et al., 'Development of silicon interposers with embedded microchannels and metal re-distribution layer for the integration of hybrid detector systems', Nuclear Instruments and Methods A, 1065 (2024) 169490
Keywords: Microchannel cooling, Embedded microchannels, Monolithic integration