New radiation detector technologies for medical imaging (1)

Session chair: Cates, JoshuaW., (Lawrence Berkeley National Laboratory, Applied Nuclear Physics, Berkeley, USA); Freire, Marta, (Institute for Instrumentation in Molecular Imaging (i3M), CSIC-UPV, Valencia, Spain)
 
Shortcut: MIC-09
Date: Thursday, 12 November, 2026, 15:00 - 17:00
Location: MANUEL DE FALLA
Session type: MIC Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

15:00 MIC-09-01

Deep learning-based estimation of individual scintillation photon arrival times for enhanced TOF resolution (#1210)

Y. Onishi1, 2, R. Ota1, F. Hashimoto4, K. Ote1, G. Akamatsu3, H. Tashima3, T. Yamaya3, 2

1 Hamamatsu Photonics K.K., Central Research Laboratory, Hamamatsu, Japan
2 Chiba University, Graduate School of Science and Engineering, Chiba, Japan
3 National Institutes for Quantum Science and Technology, Department of Advanced Nuclear Medicine Sciences, Chiba, Japan
4 University of Florida, J. Crayton Pruitt Family Department of Biomedical Engineering, Gainesville, United States of America

Abstract

The coincidence time resolution of scintillation detectors plays a critical role in time-of-flight positron emission tomography (TOF-PET) and it is fundamentally limited by the emission, transport, and detection processes of scintillation photons. Although previous analytical and Monte Carlo simulation studies have suggested that exploiting multiple timing information of scintillation photons could approach the theoretical timing limits, direct experimental access to all detected photon timestamps remains unavailable with standard PET detectors using analog silicon photomultipliers (SiPMs). To address this challenge, we previously proposed a deep learning-based approach to recover photon timestamps on an event-by-event basis by removing the SiPM degradation factor from detector waveforms within an unsupervised learning framework. Our experimental evaluations demonstrated that the recovered photon behavior is consistent with previous findings, although the absence of ground-truth timestamps inevitably limited a rigorous and quantitative assessment of its validity and reliability. In this study, we evaluate the proposed method using Monte Carlo simulation data with fully known photon-level information. The recovered photon timestamps were quantitatively compared with the true timestamps in terms of timing bias, timing uncertainty, and total photon count fidelity. The results showed that the proposed method achieves timing biases within approximately 10 ps and maintains acceptable timing precision across photons while accurately preserving the number of detected photons per event. With the optimized parameter settings, we will further improve temporal precision in timestamp recovery using experimental data.

References
[1] D. Schaart. Physics and technology of time-of-flight PET detectors. Phys. Med. Biol., 66, 09TR01, 2021.
[2] S. Gundacker et al. On the comparison of analog and digital SiPM readout in terms of expected timing performance. Nucl. Instrum. Methods Phys. Res. A. 787, 6-11, 2015.
[3] J. Cate et al. Analytical calculation of the lower bound on timing resolution for pet scintillation detectors comprising high-aspect-ratio crystal elements. Phys. Med. Biol., 60, 5141, 2015.
[4] N. Kratochwil et al. Analytic timing calculations and timing limits with prompt photons, high-aspect-ratio crystals, and complex TOF-kernels in TOF-PET. IEEE Trans. Radiat. Plasma. Med. Sci., 2026.
[5] Y. Onishi et al. Single Photon Response Deconvolution for Boosting an Understanding of BGO Emission. 2024 IEEE NSS/MIC/RTSD, 2024.
[6] Y. Onishi et al. Single Photon Response-Informed Neural Network for Photon Timestamp Recovery and Improved CTR. 2025 IEEE NSS/MIC/RTSD, 2025.
Keywords: TOF, multiple photon timestamps, unsupervised deep learning, deconvolution, Monte Carlo simulation
15:15 MIC-09-02

Inter-Crystal Scattering Recovery in Semi-Monolithic Crystals: an Experimental and Simulation Study (#1581)

F. Pagano1, F. Loignon-Houle1, D. Sanchez2, E. Elmoujarkach3, N. Karakatsanis3, J. Cateret2, S. Nehmeh3, A. Gonzalez1

1 CSIC-Universitat Politècnica de València, Institute for Instrumentation in Molecular Imaging (I3M), Valencia, Spain
2 Oncovision, Valencia, Spain
3 Weill Cornell Medical College, Department of Radiology, New York, New York, United States of America

Abstract

In positron emission tomography (PET), inter-crystal scattering (ICS) is a major source of uncertainty contributing to spatial resolution. While rejecting ICS events can improve the resolution, it comes at the cost of sensitivity. Accurately recovering the first interaction position is therefore crucial for maintaining both high sensitivity and spatial resolution.
In this work, we apply ICS recovery to experimental data from semi-monolithic detectors, with a 2:1 slab-to-SiPM ratio using both analytical and deep-learning (DL) approaches. We developed a GATE Monte Carlo simulation framework tuned to reproduce experimental signals for data augmentation. A multilayer perceptron (MLP) achieved ~78% exact layer prediction, with an additional ~15% misassigned by only one slab, leaving just ~7% exceeding 1.5 mm (one slab thickness). This outperforms analytical methods, particularly for ICS-only events, where the MLP is 16 percentage points more accurate, and the analytical method fails entirely at edge slabs. We show simulated signals closely match experimental data; additional tuning will enable their use in training networks for experimental application. 
This study takes a first step toward combining simulated and experimental data for DL-based ICS recovery, which could bypass individual detector array calibration.

AcknowledgmentThis work was partially supported by the National Institutes of Health (NIH) under award number 1R01CA275942-01A1
References
[1] Lee, Min Sun, Hyeong Seok Shim, and Jae Sung Lee. "Strategies for mitigating inter-crystal scattering effects in positron emission tomography: a comprehensive review." Biomedical Engineering Letters 14.6 (2024): 1243-1258.
[2] Kuang, Zhonghua, et al. "Effects of inter-crystal scattering events on the performance of SIAT aPET." Physics in Medicine & Biology 70.17 (2025): 17NT01.
[3] Chung, Yong Hyun, et al. "New design of a quasi-monolithic detector module with DOI capability for small animal pet." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 593.3 (2008): 588-591.
[4] Pagano, Fiammetta, et al. "Semi-monolithic detectors for TOF-DOI brain PET: Optimization of time, energy, and positioning resolutions with varying surface treatments." IEEE Transactions on Radiation and Plasma Medical Sciences (2025).
[5] Loignon-Houle, Francis, et al. "Reflectivity quenching of ESR multilayer polymer film reflector in optically bonded scintillator arrays." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 851 (2017): 62-67.
Keywords: PET, ICS, semi-monolithic, deep-learning
15:30 MIC-09-03

A High Resolution Semi-Monolithic GAGG Detector Aiming for SPECT Imaging (#2693)

Y. Zhao1, 2, K. Wang1, J. Dang1, W. Huang2, Z. Yan1, Z. Gu2, Q. Wei1

1 University of Science and Technology Beijing, School of Automation and Electrical Engineering, Beijing, China
2 Shenzhen Bay Laboratory, Institute of Biomedical Engineering, Shenzhen, China

Abstract

High-resolution SPECT imaging requires detectors with high intrinsic spatial resolution, good energy resolution, and high detection efficiency. Pixelated scintillator arrays are commonly used to improve the intrinsic spatial resolution, but sub-millimeter pixels increase fabrication complexity and cost, and inter-crystal gaps may reduce detection efficiency.

In this work, we developed and evaluated a semi-monolithic GAGG SPECT detector composed of 29 stacked continuous crystal slabs. Each slab measured 25.8 × 0.8 × 6 mm³, and adjacent slabs were separated by 0.08 mm-thick BaSO4 reflectors. The detector was coupled to a silicon photomultiplier (SiPM) array (Hamamatsu MPPC S14161-3050HS) and read out using a PETsys TOFPET2 ASIC. A tungsten parallel-slit collimator with 13 slits, a 2 mm pitch, and a 0.8 mm slit width was placed directly in front of the detector entrance surface for flood image, energy resolution (ER), and intrinsic spatial resolution (ISR) measurements.

Most pseudo-pixels (defined as discrete areas on the flood image based on the crystal look-up table) were clearly resolved in the flood image, except for several edge crystal pixels, with average peak-to-valley ratios of 5.4 ± 2.1 and 7.4 ± 3.9 in the X and Y directions, respectively. Within a 110–170 keV energy window, DOI-based energy correction improved the average ER from 15.37% ± 1.75% to 11.07% ± 0.77% at 140 keV. The average ISR were 1.02 ± 0.36 mm and 0.42 ± 0.29 mm in the X and Y directions, respectively.

In conclusion, these results demonstrate that the proposed semi-monolithic GAGG detector can achieve good energy resolution and sub-millimeter-level intrinsic spatial resolution, showing potential for high-resolution SPECT imaging.

Acknowledgment

This work was supported in part by National Natural Science Foundation of China (Grant Number:12375337) and Beijing Natural Science Foundation (Grant Number: L232126).

References
[1] Yu Z, Lyu Z, Fan P, Wu J, Liu Y, Ma T.Submillimeter Pixelated SPECT Detector Using GAGG:Ce and Light Guide With Optical Barrier Slits. IEEE Trans. Radiat. Plasma Med. Sci.,2025, 9 (8): 1015-1024.
[2] Wei Q, Ma T, Jiang N, Xu T, Lyu Z, Hu Y, Liu Y.A side-by-side LYSO/GAGG phoswich detector aiming for SPECT imaging. Nucl. Instrum. Methods Phys. Res. A,2020, 953.
Keywords: SPECT, GAGG scintillator, semi-monolithic detector, SiPM, high resolution
15:45 MIC-09-04

Feasibility of Cherenkov-only Radiation Emitters Coupled to SiPMs for PET (#1180)

A. X. Pinto1, N. Kratochwil2, L. Rebolo2, 1, A. H. LeBeau4, R. Hernandez4, J. Veloso1, B. Mehadiji2, P. Correia1, A. L. Silva1, G. Ariño-Estrada2, 3

1 University of Aveiro, I3N Physics Department, Aveiro, Portugal
2 University of California Davis, Department of Biomedical Engineering, Davis, California, United States of America
3 Institut de Física d’Altes Energies - Barcelona Institute of Science and Technology (IFAE-BIST), Barcelona, Spain
4 University of California, Department of Radiation Oncology, School of Medicine,, Davis, California, United States of America

Abstract

Recent applications of Positron Emission Tomography (PET) in dosimetry such as Pair Production Tomography (P2T) or Proton Range Verification (PRV) require a detector count rate capacity far beyond the conventional range for diagnostic-oriented PET. Most commonly used PET detectors use scintillation crystal coupled to silicon photomultipliers (SiPMs). For high count rate situations the scintillation decay time in the range of tens of nanoseconds can lead to undesired pile-up effects.

In this work, we explore the feasibility of using Cherenkov-only emitter based on PbF₂ coupled to SiPMs to overcome the limitation posed by the long scintillation tails. While Cherenkov-only emitters have been proposed and tested for ultra-fast timing in time-of-flight PET (TOF-PET), the goal of this work is to evaluate the feasibility of using them in readily scalable setup.

We used 3×3×3-20 mm³ PbF₂ crystals coupled to Broadcom NUV-MT SiPMs (4×4 mm²) and custom low-noise high-frequency (LN-HF) readout electronics. SiPM over-voltages from +2 to +8 V and different trigger levels were evaluated to determine the optimal performance for this type of application, focusing on the true coincidence fraction (TCF), coincidence ratio and coincidence timing resolution (CTR), in order to assess if the Cherenkov signals are discernible from background noise. Additionally, we tested the same setup read out by an ASIC (FastIC evaluation board) to understand the impact of an integrated system-applicable readout. Using LN-HF-readout electronics and an excess bias voltage of +4 V we measure a TCF of 81% and a CTR of 240±2 ps. Using the FastIC ASIC, the best results were a TCF of 81% and a CTR of 506±6 ps. Our results demonstrate the potential of Cherenkov-only radiators for high count rate PET applications.

Acknowledgment

This work was supported by the Prototera grant PRT/BD/154558/2023; by national funds through Fundação para a Ciência e a Tecnologia (FCT), I.P., and the Ministry of Science, Technology and Higher Education under projects UID/50025/2025 (10.54499/UID/50025/2025), UID/PRR/50025/2025 (10.54499/UID/PRR/50025/2025), and UID/PRR2/50025/2025 (10.54499/UID/PRR2/50025/2025); and by the Associate Laboratory Institute of Nanostructures, Nanomodelling and Nanofabrication under project LA/P/0037/2020 (10.54499/LA/P/037/2020).

References
[1] Lyu, Q, Neph, R, Sheng, K 2023, ‘Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing’, Nature Biomedical Engineering, vol. 7, no. 3, pp. 323–334, New York: Springer Nature
[2] Consuegra, D, Korpar, S, Križan, P, Pestotnik, R, Razdevšek, G, Dolenec, R 2020, ‘Simulation study to improve the performance of a whole-body PbF₂ Cherenkov TOF-PET scanner’, Physics in Medicine & Biology, vol. 65, no. 5, article 055013, Bristol: IOP Publishing.Consuegra, D, Korpar, S, Križan, P, Pestotnik, R, Razdevšek, G, Dolenec, R 2020, ‘Simulation study to improve the performance of a whole-body PbF₂ Cherenkov TOF-PET scanner’, Physics in Medicine & Biology, vol. 65, no. 5, article 055013, Bristol: IOP Publishing.
[3] Kratochwil, N, Gundacker, S, Auffray, E 2021, ‘Roadmap toward Cherenkov-based PET’, Physics in Medicine & Biology, Bristol: IOP Publishing. DOI: 10.1088/1361-6560/ac212a.
[4] Cates, JW, Gundacker, S, Auffray, E, Lecoq, P, Levin, CS 2018, ‘Improved single photon time resolution for analog SiPMs’, Physics in Medicine & Biology, Bristol: IOP Publishing. DOI: 10.1088/1361-6560/aadbcd.
[5] Gómez, S, Alozy, J, Campbell, M, Fernandez-Tenllado, JM, Manera, R, Mauricio, J, Pujol, C, Sanchez, D, Sanmukh, A, Sanuy, A, Ballabriga, R, Gascon, D 2022, ‘FastIC: a fast integrated circuit for timing applications’, Journal of Instrumentation, vol. 17, no. 5, article C05027, Bristol: IOP Publishing. DOI: 10.1088/1748-0221/17/05/C05027.
[6] Pinto, AX, Kratochwil, N, Gómez, S, Gascón, D, Correia, P, Veloso, J, Roncali, E, Silva, AL, Ariño-Estrada, G 2025, ‘Improving Cherenkov PET detector performance using FastIC readout electronics’, IEEE Transactions on Radiation and Plasma Medical Sciences, New York: IEEE. DOI: 10.1109/TRPMS.2025.3532794.
Keywords: TOF-PET, Cherenkov, Coincidence Timing Resolution, Cherenkove Emitters, Positron Emission Tomography
16:00 MIC-09-05

Scan Time and Effective Dose Reduction using an Ultra-Fast Molecular Breast Imaging System (#2691)

A. Cherlin1, M. Exley1, N. Atkins1, K. Erlandsson2, I. Baistow1, B.F. Hutton2, M. O'Connor3, C. Hruska3, K. Thielemans2

1 Kromek Ltd., Sedgefield, United Kingdom
2 University College London, Institute of Nuclear Medicine, London, United Kingdom
3 Mayo Clinic, Department of Radiology, Rochester, Minnesota, United States of America

Abstract

A prototype stationary tomographic ultra-fast Molecular Breast Imaging system (UFMBI) has been developed and characterised using phantom studies. The system combines ultra-high resolution CZT detectors with depth‑of‑interaction (DOI) sensitivity and wide‑angle sampling from densely packed multi‑pinhole (MPH) collimators, together with novel de‑multiplexing reconstruction to mitigate multiplexing artefacts. This approach enables substantial reductions in scan time (∼40 min) and radiation dose (∼2.4 mSv) compared with conventional MBI, supporting wider adoption as a supplemental screening tool for women with dense breast tissue.
A dual-head prototype with a field-of-view of 132mm x 88mm has been designed and built. Each head consists of a 6x4 array of 5 mm thick CZT detectors with 11x11 grid of 2 mm pixels. Raw detector data are processed using a machine learning model providing 10x10 sub-pixelisation and DOI sensitivity. Image reconstruction uses OSEM algorithm incorporating attenuation, collimator blurring, septal penetration and multiplexing effects.
Performance was evaluated using uniform and spherical lesion phantoms (5–9 mm) at tumour‑to‑background ratios of 10–20:1, with comparison to a clinical planar MBI system by imaging 99mTc-infused gel phantoms. Dose/time reduction factors (DRF) were evaluated by resampling measured data relative to the reference equivalent to current clinical practice. Lesion detectability was assessed using contrast‑to‑noise ratio (CNR) and the Rose criterion (CNR>3). Sphere studies demonstrated detectability of 5–7 mm lesions at DRF = 8. Gel phantom experiments showed that UFMBI achieved ~2.9× higher CNR than the clinical system at reference conditions and ~2× higher at DRF = 6.
These results demonstrate the feasibility of UFMBI as a high‑throughput tomographic extension of conventional MBI, with potential application as a supplemental screening tool for women with dense breasts.

References
[1] Rhodes, D et al. 2015 “JOURNAL CLUB: Molecular Breast Imaging at Reduced Radiation Dose for Supplemental Screening in Mammographically Dense Breasts”, AJR Am J Roentgenol. vol. 204, pp. 241-251.
[2] Erlandsson, K, Wirth, A, Thielemans, K, Baistow, I, Cherlin, A, Hutton, BF et al. 2023 “Design of a Low-Dose, Stationary, Tomographic Molecular Breast Imaging System Using 3-D Position Sensitive CZT Detectors”, IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 7(3), pp. 225-232.
[3] Cherlin, A, Atkins, N, Baistow, I, Erlandsson, K, Thielemans, K, Hutton, BF “Performance of the prototype of an ultra-low-dose stationary tomographic Molecular Breast Imaging (ULDMBI) camera”, in 2024 IEEE RTSD, Tampa, FL, USA.
[4] Long, Z, Conners, A, Hunt, KN, Hruska, CB, O'Connor, M 2016 “Performance characteristics of dedicated molecular breast imaging systems at low doses”, Med. Phys. 43 (6) p. 3062.
Keywords: Molecular breast imaging, multi-pinhole collimator, angular sampling, dose reduction, tomography
16:15 MIC-09-06

Scalable Cherenkov-Enhanced Timing in BGO with FastIC+ (#1562)

F. Loignon-Houle1, F. Pagano1, D. Mazzanti2, A. Olmos-Risen1, N. Cucarella1, D. Guberman2, O. de la Torre2, S. Gomez3, D. Gascon2, A. J. Gonzalez1, A. Gonzalez-Montoro1

1 Institute for Instrumentation in Molecular Imaging (i3M), CSIC-UPV, Valencia, Spain
2 Institute of Cosmos Science, University of Barcelona, Barcelona, Spain
3 Universitat Politècnica de Cataluña, Barcelona, Spain

Abstract

The ultrafast nature of Cherenkov photon emission offers an avenue to improve the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) detectors. Bismuth germanate (BGO) provides a higher Cherenkov photon yield than conventional lutetium-based crystals, but its slow scintillation component induces large variations in signal shape. Measuring the rise time of the signals, obtained from the time difference between two threshold crossings, enables classification of events by Cherenkov yield and time-offset correction to improve the CTR. While this principle has been demonstrated with dedicated fast electronics, scalable implementation remains a challenge. Here, we exploit the dual-threshold capability of the new FastIC+ ASIC to extract rise-time information in BGO-based detectors and study the influence of bias voltage, settings of thresholds, and rise-time correction methods on CTR performance. We obtained a 32% CTR improvement, from 577 to 395 ps FWHM, with 3×3×15 mm3 polished BGO coupled to 3×3 mm2 FBK NUV-MT SiPMs biased at 49 V, and we show trade-offs between noise rejection and rise-time correction efficiency as a function of the two selected thresholds. This work marks a concrete step toward a scalable approach to exploiting BGO's mixed Cherenkov–scintillation emission in TOF-PET imaging.

AcknowledgmentThis work was funded by the European Union (ERC, PHOENIX, 101164363). Views and opinions expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the European Research Council. Neither the European Union nor the granting authority can be held responsible for them.
References
[1] G Ariño-Estrada et al, "Current Status of Cherenkov-Based Gamma Detectors for TOF-PET and Proton Range Verification", IEEE Trans. Radiat. Plasma Med. Sci., 10(1), pp. 1–15, 2026
[2] S Gundacker et al, "Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission", Phys. Med. Biol, 65(2), pp. 025001, 2020
[3] N Kratochwil et al, "Exploring Cherenkov Emission of BGO for TOF-PET", IEEE Trans. Radiat. Plasma Med. Sci., 5(5), pp. 619–629, 2021
[4] A Gonzalez-Montoro et al, "Cherenkov Radiation–Based Coincidence Time Resolution Measurements in BGO Scintillators", Front Phys, 10, 2022
[5] F Loignon-Houle et al, "Improving timing resolution of BGO for TOF-PET: a comparative analysis with and without deep learning", EJNMMI Phys, 12(1), 2025
[6] D Mazzanti et al, "Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond", IEEE Trans. Radiat. Plasma Med. Sci., 2026
[7] S Xie et al, "Methods to Compensate the Time Walk Errors in Timing Measurements for PET Detectors", IEEE Trans. Radiat. Plasma Med. Sci., 4(5), pp. 555–562, 2020
[8] J Nuyts et al, "The SNR of Positron Emission Data With Gaussian and Non-Gaussian Time-of-Flight Kernels, With Application to Prompt Photon Coincidence", IEEE TMI, 42(5), pp. 1254–1264, 20
Keywords: BGO, TOF-PET, FastIC+, Cherenkov, Fast timing
16:30 MIC-09-07

An Optimized Two-Layer PET&SPECT Shared Detector based on a Scintillator-as-Collimator Design (#1674)

Y. Zhao1, 2, C. Huang1, X. Zeng1, H. Yang1, W. Huang1, X. Jiang1, 2, X. Zhang1, M. Niu1, Y. Liang3, Q. Wei2, Z. Gu1

1 Shenzhen Bay Laboratory, Institute of Biomedical Engineering, Shenzhen, China
2 University of Science and Technology Beijing, University of Science and Technology Beijing, Beijing, China
3 Cancer Hospital Chinese Academy of Medical Sciences, Department of Nuclear Medicine, Shenzhen, China

Abstract

Simultaneous PET and SPECT imaging enables concurrent characterization of multiple biological processes, but conventional multi-modality systems typically require separate detector subsystems. We previously proposed a scintillator-as-collimator design for a PET&SPECT shared detector, and demonstrated PET, SPECT, and simultaneous PET&SPECT imaging capabilities. Nevertheless, the scintillator-as-collimator volume (SCV) lacked depth-of-interaction (DOI) discrimination in PET mode, and the thickness of the SPECT Detector volume (SD) was not optimized, compromising its time-of-flight (TOF) PET performance. To address these limitations, we developed an optimized two-layer PET&SPECT detector with a top 16×16 LYSO array (1.53×1.53×10 mm³) and a bottom 8×8 LYSO array (3×3×10 mm³), separated by two 2-mm light guides. The block was coupled to an MPPC array and read out by a PETsys TOFPET2 ASIC. To evaluate the effect of hole drilling on performance, two prototype detectors were fabricated: a drilled detector with holes in the top LYSO array and light guides, and a non-drilled reference. Both detectors used unpolished crystal sides with BaSO4 reflectors. Flood images, energy resolution (ER), DOI resolution, and coincidence time resolution (CTR) were evaluated.
​​​​​​​The drilled detector achieved effective DOI discrimination in both SCV and SD. After excluding ICS events, DOI resolutions of 3.60 ± 0.43 mm and 2.18 ± 0.15 mm were obtained in the top and bottom layers, with a bottom-to-bottom CTR of 259 ps. The DOI and CTR are comparable to those of the non-drilled reference detector.
In conclusion, these results validate the optimized two-layer scintillator-as-collimator design and demonstrate its potential for a  PET&SPECT shared detector with high DOI and TOF performance. Future work will evaluate the capability of the SD region in detecting 140 keV gamma photons and develop a prototype system for imaging validation.

Acknowledgment

This work is supported by the National Key R&D Program of China (No. 2023YFC2414800), the Major Program of Shenzhen Bay Laboratory (No. C1012530005), the National Natural Science Foundation of China (Nos. 12275182 and 62371314), Guangdong Basic and Applied Basic Research Foundation (Nos. 2024A1515012154), the Guangdong Provincial Project (Grant No. 2023TQ07A233) and the Shenzhen Bay Laboratory Proof-of Concept Grants (No. C1022430005).

References
[1]  X Zeng, H Yang, M Niu, W Huang, X Jiang, S Huang, C Huang, Z Chen, X Zhang, Y Liang and Z Gu, Tri-mode PET, SPECT, and PET&SPECT imager using a novel scintillator-as-collimator, IEEE Nuclear Science Symposium and Medical Imaging Conference, 2025.
[2]  He, W, Zhao, Y, Huang, W, Zhao, X, Niu, M, Yang, H, Zhang, L, Ren, Q, & Gu, Z. A multi-resolution TOF-DOI detector for human brain dedicated PET scanner. Physics in Medicine and Biology, 69(2), 2024.
Keywords: Scintillator-as-collimator, Depth-of-interaction (DOI), Time-of-flight (TOF), Dual-layer, PET&SPECT detector
16:45 MIC-09-08

Unlocking Next-Generation Time-of-Flight Imaging with the PoETIC ASIC (#1270)

J. M. Fernandez-Tenllado1, M. Ribalda1, J. Mauricio1, A. Espinya1, M. Viqueria2, J. J. Silva1, S. Portero1, G. Bergamin2, D. Mazzanti1, L. J. Imas1, D. Guberman1, A. Sanuy1, J. A. Alozy2, O. de la Torre1, M. Penna4, R. Dolenec3, C. Trippl4, J. M. Benlloch5, D. Sanchez6, S. Majewski8, A. Gola4, G. El Fakhri7, R. Pestotnik3, R. Ballabriga2, D. Gascon1

1 Universitat de Barcelona (UB), Institut de Ciències del Cosmos (ICCUB), Barcelona, Spain
2 Conseil Européen pour la recherche nucléaire (CERN), Microelectronics Section, Meyrin, Genève, Switzerland
3 Jožef Stefan Institute (JSI), Experimental Particle Physics, Ljubljana, Slovenia
4 Fondazione Bruno Kessler (FBK), Custom Radiation Sensors, Trento, Italy
5 Consejo Superior de Investigaciones Cientificas (CSIC), Institute for Instrumentation in Molecular Imaging (I3M), Valencia, Spain
6 Oncovision, Valencia, Spain
7 Yale University, PET Center at Yale School of Medicine, New Haven, Connecticut, United States of America
8 Univeristy of California, Biomedical Engineering, Davis, California, United States of America

Abstract

Time-of-Flight Positron Emission Tomography requires readout electronics capable of extracting precise timing information. The Positron Emission Tomography Integrated Circuit (PoETIC) has been developed to bridge the performance gap between the intrinsic timing resolution of the detector and that achievable with integrated readout solutions, while remaining scalable in channel count and power consumption. PoETIC introduces a novel channel architecture based on two fully independent analog front-ends per channel, separately optimized for timing and energy measurements, and thereby relaxing conflicting design requirements at the input stage. Fabricated in 65 nm CMOS technology, the PoETIC die integrates fast low-noise front ends, dual-threshold discriminators and a TDC with 24.4 ps time binning. Four 16-channel dies are combined into a 64-channel 2.5D Integrated Circuit. A custom high-speed serial interface supports daisy-chained data and trigger distribution, significantly reducing interconnect complexity. The power consumption is 10 mW per channel. Measurements of a first prototype show a single-photon time resolution of 57 ± 1 ps FWHM and 85 ± 1 ps FWHM using FBK NUV-HD-MT SiPMs of 1×1 mm² and 3×3 mm², respectively. Preliminary measurements yield a coincidence time resolution of 74 ± 1 ps FWHM with the 3×3 mm² SiPMs and LGSO crystals of 2×2×3 mm³. To the best of our knowledge, these results represent state-of-the-art timing performance for an ASIC and suggest that PoETIC approaches the intrinsic timing performance of scintillator crystals while offering a flexible and scalable readout solution for next-generation PET systems and other fast-timing applications.

AcknowledgmentThe authors acknowledge financial support from Grant/Award Number: 101099896 (EIC-Patfinder Petvision). 
References
[1] Nadig, V, Gundacker, S, Herweg, K, Naunheim, SN, Schug, D, Weissler, B, Schulz, VA 2025, ‘ASICs in PET: what we have and what we need’, EJNMMI Physics, 12(1), 16, Heidelberg: Springer Nature. DOI: 10.1186/s40658-025-00717-8
[2] Gundacker, S, Martinez Turtos, R, Auffray, E, Paganoni, M, Lecoq, P 2019, ‘High‑frequency SiPM readout advances measured coincidence time resolution limits in TOF‑PET’, Physics in Medicine & Biology, 64(5), 055012, Bristol: IOP Publishing. DOI: 10.1088/1361-6560/aafd52
[3] Kratochwil, N, Gundacker, S, Lecoq, P, Auffray, E 2020, ‘Pushing Cherenkov PET with BGO via coincidence time resolution classification and correction’,
Physics in Medicine & Biology, 65(11), 115004, Bristol: IOP Publishing. DOI: 10.1088/1361-6560/ab87f9
[4] Orehar, M, Dolenec, R, El Fakhri, G, Korpar, S, Križan, P, Razdevšek, G, Marin, T, Žontar, D, Pestotnik, R 2024, ‘Design optimisation of a flat‑panel, limited‑angle TOF‑PET scanner: a simulation study’, Diagnostics, 14(17), 1976, Basel: MDPI. DOI: 10.3390/diagnostics14171976
[5] Mazzanti, D, Gómez, S, Mauricio, J, Alozy, J, Bandi, FN, Campbell, M, Dolenec, R, El Fakhri, G, Fernández‑Tenllado, JM, Gola, A, Guberman, D, Majewski, S, Manera, R, Mariscal‑Castilla, A, Penna, M, Pestotnik, R, Portero, S, Paternò, A, Sanuy, A, Silva, JJ, Ballabriga, R, Gascón, D 2026, ‘100 ps CTR using FastIC+, an ASIC including on‑chip digitization for TOF‑PET and beyond’, IEEE Transactions on Radiation and Plasma Medical Sciences, Early Access, 1–1, Piscataway, NJ: IEEE. DOI: 10.1109/TRPMS.2026.XXXX
Keywords: Front-End ASIC, PET, ToF-PET, TDC, SiPM


Our Exhibitors: