RTSD Medipix/Timepix Detectors

Session chair: Datta, Amlan, Dr. (CapeSym, Inc., Research and Developement, Natick, USA); Frojdh, Christer, Professor (Mid Sweden University, Sweden)
 
Shortcut: RTSD-08
Date: Wednesday, 11 November, 2026, 17:30 - 19:00
Location: ANDALUCÍA II & III
Session type: RTSD Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

17:30 RTSD-08-01

The Timepix ASIC Family: Past, Present, and Future (#3005)

R. Ballabriga1, X. Llopart1, M. Campbell1

1 CERN, Meyrin, Switzerland

On behalf of the Medipix2, Medipix3 and Medipix4 Collaborations

Abstract

This summary reviews the evolution of the Timepix family of hybrid pixel detector readout ASICs, from Timepix in 2006 through to the recently released Timepix4 and the forthcoming Picopix demonstrator. The early versions had a regular matrix of 256x256 pixels. Each generation introduced an architectural innovation: per-pixel programmable Time-of-Arrival (ToA) or Time-over-Threshold (ToT) mode selection (Timepix, 250 nm MOS, 2006, Medipix2 Collaboration); data-driven triggerless readout with simultaneous time and energy measurement (ToA/ToT) and a 1.56 ns on-pixel TDC (Timepix3,130 nm CMOS, 2013, Medipix3 Collaboration); simultaneous ToA/ToT with logarithmic gain mode, improved energy resolution, and dead-time-free continuous read/write (Timepix2,130 nm CMOS, 2018, Medipix2 Collaboration); and 195 ps ToA binning over a four-side buttable 448x512 matrix using through-silicon via (TSV) technology (Timepix4, 65 nm CMOS, 2019, Medipix4 Collaboration). The forthcoming Picopix (28 nm CMOS, submission foreseen in 2026) targets ∼35 ps ToA binning with on-pixel clustering, on-chip time calibration, and packet sorting. Key quantitative parameters—timing resolution, hit rate, active area, power consumption, and readout bandwidth—are compared across all five generations. Representative applications and the knowledge-transfer impact of the Medipix Collaborations model are discussed.

Keywords: hybrid pixel detectors, time-over-threshold, time-of-arrival, particle tracking, timepix
18:00 RTSD-08-02

Timepix4 based photon-counting detector for full-spectral X-ray micro computed tomography (#1355)

P. Cardarelli1, N. V. Biesuz1, F. Brun2, 3, V. Cavallini1, 5, P. Delogu6, 7, A. Feruglio6, 7, M. Fiorini1, 5, R. Longo2, 4, V. Mazzini1, 5, P. Oliva7, 6, V. Rosso7, 6, S. Velardita1, L. Brombal2, 3

1 INFN, Ferrara Division, Ferrara, Italy
2 INFN, Trieste Division, Trieste, Italy
3 Università di Trieste, Dipartimento di Ingegneria e Architettura, Trieste, Italy
4 Università di Trieste, Dipartimento di Fisica, Trieste, Italy
5 Università di Ferrara, Dipartimento di Fisica e Scienze della Terra, Ferrara, Italy
6 Università di Pisa, Dipartimento di Fisica, Pisa, Italy
7 INFN, Pisa Division, Pisa, Italy

Abstract

Timepix4 is the latest generation of the readout ASIC developed by the Medipix4 Collaboration for hybrid pixel detector technology, featuring a 448 x 512 matrix with a 55 μm pitch. Operating in data-driven mode, it provides simultaneous Time of Arrival (ToA) and Time over Threshold (ToT) information for each hit. This allows for multi-pixel signal clustering to mitigate charge sharing and fluorescence escape, while calibrated ToT values provide per-pixel energy measurement. Such capabilities enable high-resolution X-ray spectral imaging, providing accurate energy deposition information for each detected event and greater post-processing flexibility compared to traditional threshold-based photon-counting systems. In this work, we present the first full-spectral micro-CT images acquired with a Timepix4-based detector operating in data-driven mode. The detector is equipped with a 1 mm-thick CdTe sensor, making it suitable for X-ray energies commonly used in biomedical applications. Tomographic scans were performed at the INFN PEPI laboratory using a microfocus X-ray tube (80 kV, 20 μA). The study evaluated a custom plastic phantom containing three distinct contrast agents: silver, iodine, and gadolinium. Projections were acquired over 360° with a reconstructed voxel size of 33 μm. The resulting 3D attenuation spectra were processed using a basis material decomposition algorithm, producing independent 3D density maps for each contrast agent. The results confirm the feasibility of full-spectral micro-CT imaging using the Timepix4 ASIC, demonstrating its ability to capture 3D attenuation spectra at high spatial resolution. While data rate management remains a challenge, the ability to resolve full attenuation spectra in 3D enables precise multi-material identification in a single scan. This capability offers significant potential for advanced applications in biomedical research and materials science.

AcknowledgmentThis work was supported by the INFN-CSN5 experiment TIMEPIX4.
References
[1] X. Llopart, J. Alozy, R. Ballabriga, M. Campbell, R. Casanova, V. Gromov, E. Heijne, T. Poikela, E. Santin, V. Sriskaran et al., “Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning,” Journal of Instrumentation, vol. 17, no. 01, p. C01044, 2022.
[2] V. Cavallini, N. V. Biesuz, R. Bolzonella, E. Calore, M. Fiorini, A. Gianoli, X. L. Cudie, and S. F. Schifano, “DataPix4: A C++ framework for Timepix4  onfiguration and read-out,” Comput. Phys. Commun., p. 109658, 2025
[3] L. Brombal, F. Arfelli, R. H. Menk, L. Rigon, and F. Brun, “PEPI lab: a flexible compact multi-modal setup for x-ray phase-contrast and spectral imaging,” Scientific Reports, vol. 13, no. 1, p. 4206, 2023.
[4] P. Delogu, N. V. Biesuz, R. Bolzonella, L. Brombal, V. Cavallini, F. Brun, P. Cardarelli, A. Feruglio, M. Fiorini, R. Longo, and V. Rosso, “Validation of Timepix4 Energy Calibration Procedures with Synchrotron X-ray Beams,” Nuclear Instruments and Methods in Physics Research A, vol. 1068, p. 169716, 2024.
Keywords: Photon-counting, CdTe, spectral imaging, hyperspectral detector, micro computed tomography
18:15 RTSD-08-03

Machine learning pipeline for spectral material identification with a CdTe-Timepix3 detector (#1932)

J. S. Useche Parra1, M. Schütz1, G. Roque1, S. Procz1, M. Fiederle1

1 University of Freiburg, Freiburg Material Research Center, Freiburg, Baden-Württemberg, Germany

Abstract

X-ray imaging systems are widely used in industries such as homeland security, non-destructive testing, archaeological research, and medicine, where accurate material identification is often essential. Examples include explosives screening in airport luggage, product quality testing on a production line, and content characterization in historical manuscripts. Photon-counting detectors provide high spatial and energy resolution, along with full spectroscopic information on a per-event basis, and are therefore well suited for machine learning (ML) approaches to material identification. One example of such a detector is the Timepix3, which records single events at fluxes up to 40 Mhits/cm2/s. Previous work, presented at this conference, demonstrated the feasibility of training an ML classifier (Gradient-Boosted Trees) on measured X-ray spectra acquired with a 12x1 Timepix3 (bump-bonded to 1 mm CdTe) detector and reported initial identification results on a multi-material phantom. This contribution extends that work, addressing two limitations of its results: the restricted size of the experimental material database and the lack of quantitative model diagnostics. The database is supplemented with simulated spectra (generated with the Allpix Squared framework) for materials that are difficult to obtain as pure reference samples, and the consistency between simulated and measured data is assessed. The extended database is then used to retrain the classifier, and standard ML diagnostics are reported to characterize model behavior. The performance of this approach will be compared to classical techniques such as base-material decomposition.

AcknowledgmentThe authors acknowledge funding of DFG under the nanoCT-project (PR1897/1-1) and of BMFTR under PERODET (05K22VFA).
References
[1] Clouet, A. 2022, 'Digital X-ray Imaging Report' YOLE Intelligence
[2] Dudak, J et al. 2022, 'Multi bin energy-sensitive micro-CT using large area photon-counting detectors Timepix', J. Instrum., vol. 17, p. C01028
[3] Llopart Cudié, X 2007, 'Design and characterization of 64K pixels chips working in single photon processing mode', Ph.D. dissertation, Sundsvall, Sweden: Mid Sweden University.
[4] Poikela, T et al. 2014, 'Timepix3: a 65K channel hybrid pixel readout chip with simultaneous ToA/ToT and sparse readout', J. Instrum., vol. 9, p. C05013.
[5] Koenig, T et al. 2013, 'Charge summing in spectroscopic x-ray detectors with high-Z sensors', IEEE Trans. Nucl. Sci., vol. 60, no. 6, pp. 4713–4718.
[6] Žemlička, J et al. 2009, 'Energy- and position-sensitive pixel detector Timepix for X-ray fluorescence imaging', Nucl. Instrum. Methods Phys. Res. A, vol. 607, no. 1, pp. 202–204.
[7] Schütz, MK et al. 2024, 'Element identification by K-edge imaging using spectroscopic photon counting detectors', IEEE Trans. Nucl. Sci., vol. 71, no. 1, pp. 106–112.
[8] Spannagel, S et al. 2018, 'Allpix2: A modular simulation framework for silicon detectors', Nucl. Instrum. Methods Phys. Res. A, vol. 901, pp. 164–172.
[9] Ballabriga, R et al. 2024, 'A simulator for Timepix-like pixel front-ends', J. Instrum., vol. 19, no. 3, p. C03022.
Keywords: CdTe, Machine learning, Material identification, Semiconductor detectors, Spectroscopic Photon-Counting Detectors
18:30 RTSD-08-04

Full Scale Microstructural Imaging Based on Energy dispersive X-ray Diffraction using Timepix3/4 with CdTe Sensor (#2737)

J. Jakubek1, R. Nebel1, J. Volny1, D. Vavrik2

1 ADVACAM s.r.o., Prague, Czech Republic
2 Institute of Theoretical and Applied Mechanics, Czech Academy of Sciences, Prague, Czech Republic

Abstract

This contribution extends the technique of the fast energy dispersive X-ray diffraction (XRD) in transmission mode for inspection of macroscopic objects, as described in our previous work [1], published recently by Nature Scientific Reports. This technique utilizes the event-based registration of diffracted X-ray photons with simultaneous timing and energy information as provided by Timepix3/4 detectors. It enables rapid diffraction measurements with a polychromatic X-ray source, eliminating the need for mechanical angular scanning while preserving spatially resolved structural information.

Current XRD systems utilize relatively low-energy monochromatic X-ray beam (5-20 keV) which can only penetrate shallow layer close to the sample surface. Therefore, thick or dense parts cannot be analyzed through their entire volume using standard approaches. An alternative is the use of synchrotron sources, however, these are generally impractical for industrial applications.

A hard polychromatic X-ray source (X-ray tube) in combination with spectrally sensitive imaging detector such as Timepix3 or Timepix4 equipped with high-Z sensor (CdTe or CZT) overcomes above listed limits. This work focuses on optimizing detector performance by suppressing unwanted effects such as internal X-ray fluorescence and charge-sharing. Both of these effects degrade energy resolution, which directly impacts the quality of recorded XRD data. It will be demonstrated that an optimized detector, together with an event-sorting algorithm, can provide high-quality XRD data within a fraction of a second. Such speed enables 2D scanning across the entire volume of the inspected sample.

[1] Vavrik, D., Georgiev, V., Jakubek, J. et al. Transmission energy dispersive X-ray diffraction as a tool for the laboratory study of fast processes in metals. Sci Rep 15, 31752 (2025). https://doi.org/10.1038/s41598-025-16314-9

Keywords: Timepix, XRD
18:45 RTSD-08-05

Energy-resolved Grating-based Phase-contrast Imaging with Timepix4 (#2862)

M. Schneider1, G. Anton1, B. Bergmann2, P. Burian2, T. Čelko2, P. Mánek2, S. Pospíšil2, C. Rauch1, M. Rongen1, P. Smolyanskiy2, S. Funk1

1 Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen Centre for Astroparticle Physics, Erlangen, Germany
2 Czech Technical University in Prague, Institute for Experimental and Applied Physics, Prague, Czech Republic

Abstract

Grating-based phase-contrast imaging (gbPCI) is a powerful tool for non-destructive testing and material analysis. In conventional X-ray imaging, only the attenuation of the X-rays is measured, resulting in low contrast between structures with similar absorption characteristics. With gbPCI, it is possible to not only get information about the absorption, but also the phase-shift of X-rays when propagating through material. For non-destructive testing and material analysis, the dark-field image provides complementary information, since it is sensitive to structures below the resolution limit of the system, which is primarily given by the pixel sizes of the detector. The pixel pitch is typically 50 μm or higher. With the dark-field image, it is possible to see porous or fibrous structures and estimate their sizes. A photon-counting and energy-resolving Timepix4 detector is used in this work. By setting energy cuts, the sensitivity range can be maximized, allowing a more detailed structural analysis. Additionally, the quality of the imaging system can be improved by cutting unwanted energies. First test measurements with Timepix4 have shown the feasibility of phase-contrast imaging with this detector, by acquiring energy-resolved dark-field images of lycopodium spores and a piece of wood.

AcknowledgmentThis work was supported by the Bavarian-Czech Academic Agency from funds of the Bavarian State Ministry of Science and the Arts, and by the Ministry of Education, Youth and Sports of the Czech Republic under Grant BTHA-JC-2024-80.
Keywords: Non-destructive testing, Grating-based phase-contrast imaging, Dark-field imaging, Photon-counting detectors