New Concepts and Emerging Applications

Session chair: Rafecas, Magdalena, Professor (University of Lübeck, Institute of Medical Engineering, Lübeck, Germany); Jin, Yifei, Dr.
 
Shortcut: MIC-12
Date: Friday, 13 November, 2026, 9:00 - 11:00
Location: MANUEL DE FALLA
Session type: MIC Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

9:00 MIC-12-01

Direct clinical imaging of alpha therapy in a PET/CT scanner via cascade gamma-rays imaging (#1380)

J. Caravaca1, 2, Y. Seo2, J. Cabello3, S. Siegel3, R. R. Flavell2, T. A. Hope2

1 Lawrence Berkeley National Laboratory, Applied Nuclear Physics, Berkeley, California, United States of America
2 University of California San Francisco, Radiology, San Francisco, California, United States of America
3 Siemens Medical Solutions USA, Inc., Knoxville, Tennessee, United States of America

Abstract

Targeted alpha therapy is a very promising treatment modality for numerous types of cancer. Although PET presents an excellent resolution and signal-to-noise ratio, this modality is limited to radionuclides that emit positrons and cannot be used to image alpha radionuclides such as Ac-225 and Pb-212. Therefore, SPECT is the imaging modality of choice for these radionuclides, despite its poor signal-to-noise ratio and low quantitative accuracy due to the extremely limited sensitivity of this modality. We propose a new approach that enables imaging of alpha-emitting radionuclides in PET/CT scanners: time-of-flight cascade gamma-ray imaging. Our methodology exploits the coincidence detection of gamma-ray cascades emitted by 225Ac or 212Pb to perform tomography of non-positron emitters in PET/CT scanners. Our technique is evaluated with Ac-225 and Pb-212 phantoms at low concentrations of ~44kBq/mL and short scan sessions under 5-minutes in a commercial clinical PET/CT. We also present the first clinical image of a prostate cancer patient injected with 225Ac-PSMA-617 in a clinical PET/CT system. Lastly, we predict via simulations that next-generation long-axial field-of-view PET/CT scanners will achieve a sensitivity several orders of magnitude higher than SPECT with similar or better spatial resolution.

AcknowledgmentThis work is supported by the Department of Energy and by the National Institutes of Health (NIH) under grant R01EB032324 and under clinical trial 
LuTACT NCT07054346. This research used resources of the National Energy Research Scientific Computing Center (NERSC), a Department of Energy User Facility using NERSC awards BER ERCAP0034495, BER ERCAP0035599, and DDR-NESAP ERCAP0037956. \ac~was supplied by the U.S. Department of Energy Isotope Program, managed by the Office of Isotope R\&D and Production.
References
[1] A. Jang, A. T. Kendi, G. B. Johnson, T. R. Halfdanarson, and O. Sartor, “Targeted Alpha-Particle Therapy: A Review of Current Trials,” Int. J. Mol. Sci., vol. 24, no. 14, p. 11626, Jul. 2023, doi: 10.3390/IJMS241411626.
[2] N. Benabdallah et al., “Practical considerations for quantitative clinical SPECT/CT imaging of alpha particle emitting radioisotopes,” Theranostics, vol. 11, no. 20, pp. 9721–9737, 2021, doi: 10.7150/thno.63860.
[4] C.-C. Chiang, C.-C. Chuang, Y.-C. Ni, M.-L. Jan, K.-S. Chuang, and H.-H. Lin, “Time of flight dual photon emission computed tomography,” Sci. Rep., vol. 10, no. 1, p. 19514, 2020, doi: 10.1038/s41598-020-76526-z.
[3] J. Caravaca, “Feasibility of ^225 \textAc Imaging with Time-Offlight Gamma-Ray Cascade Tomography,” in 2025 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conference (RTSD), Nov. 2025, pp. 1–1. doi: 10.1109/NSS/MIC/RTSD57106.2025.11287360.
 
[5] J. Caravaca, B. Das, H. Chu, and R. Heller, “POSSUM: a Python Image Reconstruction Framework for Emerging and Combined Modalities,” 2025 IEEE Nucl. Sci. Symp. NSS Med. Imaging Conf. MIC Room Temp. Semicond. Detect. Conf. RTSD, pp. 1–1, Nov. 2025, doi: 10.1109/NSS/MIC/RTSD57106.2025.11287697.
Keywords: tof-cgi, targeted alpha therapy, theranostics, alpha imaging
9:15 MIC-12-02

From MeV Gamma to PET Signal: Experimental Demonstration of Pair Production Tomography for Theranostic Imaging (#2289)

B. Das1, 2, R. Peter3, J. Caravaca2, 1, Y. Seo1, 4

1 University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, California, United States of America
2 Lawrence Berkeley National Laboratory, Applied Nuclear Science Division, Berkeley, California, United States of America
3 University of California, San Francisco, Department of Radiation Oncology, San Francisco, California, United States of America
4 University of California, Berkeley, Department of Nuclear Engineering, Berkeley, California, United States of America

Abstract

Imaging of theranostic radionuclides that emit high-energy (MeV range) γ rays remains extremely challenging with conventional imaging systems. SPECT performance degrades at MeV energies due to scatter and collimator penetration, while PET is inherently restricted to positron-emitting radionuclides. Pair production tomography (PPT) offers a new approach enabled by the high-energy γ interactions with matter to detectable coincidence signals. When a photon with energy ≥ 2mec2 (=1.022 MeV) undergoes pair production, the positron generated from this pair production leads to annihilation with the medium electron and emission of two 511 keV photons, enabling PET imaging. In this study, we experimentally demonstrate PPT using the 212Pb decay chain, exploiting 2.617 MeV γ rays from 208Tl. Monte Carlo simulations indicate that, despite long photon transport distances, the spatial distributions of pair production and annihilation events remain localized at the millimeter scale. Phantom experiments were performed on both clinical time-of-flight (TOF) PET and preclinical non-TOF PET systems without hardware modification using clinically and preclinically relevant 212Pb activity levels. Reconstructed PPT images successfully recovered the spatial distribution of activity, with improved contrast observed when TOF information was available. Corresponding SPECT measurements under identical conditions showed reduced visibility for smaller structures. Our results demonstrate the feasibility of PPT for imaging high-energy γ-emitting radionuclides and suggest a route to extend PET beyond conventional principles requiring positron emissions directly from radionuclides.

AcknowledgmentThis work was supported by the National Cancer Institute (NCI) grant R01CA279203 and the National Institute of Biomedical Imaging and Bioengineering (NIBIB) grant R01EB032324.
Keywords: Pair production tomography (PPT), High-energy γ-ray imaging, Targeted alpha therapy (TAT), 212Pb theranostics, Positron emission tomography (PET)
9:30 MIC-12-03

Quantitative evaluation of pair-produced positrons using a clinical linear accelerator for pair-production tomography (#2445)

R. Ota1, 2, Q. Lyu3, B. Das4, B. Faddegon3, Y. Seo4, K. Sheng3, S.I. Kwon1

1 University of California, Davis, Department of Biomedical Engineering, Davis, California, United States of America
2 Hamamatsu Photonics K.K., Central Research Laboratory, Hamamatsu, Japan
3 University of California, San Francisco, Department of Radiation Oncology, San Francisco, California, United States of America
4 University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, California, United States of America

Abstract

X-ray based radiotherapy is indispensable in modern cancer treatment yet has challenges because it is an open-loop treatment, with limited ability to verify during treatment whether the delivered dose matches the treatment plan. To address this problem, we investigated the use of positrons which are generated in a patient body during X-ray radiotherapy through pair production interactions between matter and MV X-rays, and proposed a novel imaging modality termed pair-production tomography (P2T). This is possible because the X-ray energy used for radiotherapy is a few MeV, and pair production can occur when the photon energy is higher than 1.022 MeV, producing an electron–positron pair. Their simulation results showed opportunities to utilize pair-produced positrons to not only monitor the treatment but also differentiate materials with similar density but different effective atomic numbers, which remains challenging in conventional computed tomography. However, to our best knowledge, there has been no experimental evidence of pair-produced positron detection using a clinical linear accelerator (LINAC).  Therefore, in this study, we performed experimental detection of pair-produced positrons using a LINAC. Experiments were conducted using a LINAC and a pair of radiation detectors composed of photomultiplier tubes and LYSO scintillator crystals. We successfully observed positrons generated in various phantoms via pair production. Furthermore, we quantitatively investigated sensitivity of P2T by adjusting the effective atomic number of phantoms, showing consistent results with the previous simulation results. These results provide an important step toward experimental validation of P2T.

Acknowledgment

This work was supported by NIH grants R01 EB030538 and R01EB031577.

References
[1] Q. Lyu, et al., "Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing", Nat. Biomed. Eng., 2022 vol. 7, pp 323
Keywords: Pair production tomography (P2T), Radiation therapy, Monitoring, Annihilation gamma rays
9:45 MIC-12-04

Terbium-149: a Laboratory for Three-Photon Events (#2764)

L. Mercolli1, 2, P. V. Grundler3, A. N. Moiseeva3, L. Eggimann2, S. Braccini2, U. Köster4, N. P. van der Meulen3, 5, W. M. Steinberger6

1 Inselspital, Bern University Hospital, Department of Nuclear Medicine, Bern, Bern, Switzerland
2 University of Bern, Albert Einstein Center for Fundamental Physics (AEC), Laboratory for High Energy Physics (LHEP), Bern, Bern, Switzerland
3 PSI Center for Life Sciences, Center for Radiopharmaceutical Sciences, Villigen, Aargau, Switzerland
4 Institut Laue-Langevin, Grenoble, France
5 PSI Center for Nuclear Engineering and Science, aboratory of Radiochemistry, Villigen, Aargau, Switzerland
6 Siemens Medical Solutions USA, Inc, Knoxville, Tennessee, United States of America

Abstract

Terbium-149 (149Tb) is a promising radionuclide for targeted α therapy that also emits positrons and prompt photons γ across a wide energy range, which makes it a candidate for ortho-positronium (oPs) lifetime imaging (oPsLI). We present the first demonstration of oPsLI with a therapeutic radionuclide and with γ energies below 511 keV on a commercial long-axial field-of-view PET/CT system. Using a three-lifetime-component Bayesian fitting model, we determined the oPs lifetime for the following three γ energy windows: 310 to 420 keV, 590 to 710 keV and above 720 keV. The medium- and high-energy windows yielded oPs lifetime values consistent with each other and with literature values, while the low-energy window produced systematically lower values. Voxel-wise oPsLI with small voxel size was successfully demonstrated using a single γ energy window. These results establish 149Tb as a versatile probe for exploring γ energy window effects in oPsLI, with future potential for in vivo microdosimetry and chelator stability studies.

Keywords: alpha Therapy, PET Imaging, Positronium Lifetime Imaging, Terbium-149
10:00 MIC-12-05

The first in vivo quantum entanglement imaging of a human subject (#3065)

P. Moskal1, D. Kumar1, S. Sharma1, E. Ł. Stępień1

1 Jagiellonian University, Institute of Physics, KRAKOW, Poland

Abstract

We present the first in-vivo imaging of the degree of quantum entanglement in a human subject. The reported investigations were conducted at the Cracow University Hospital in Poland using a 50 cm long, multi-photon J-PET scanner capable of registering and imaging the degree of quantum entanglement of photons originating from electron-positron annihilations in the patient’s body.

A 48-year-old male patient, administered 145 MBq of [68Ga]Ga-DOTA-TATE, was scanned for 20 minutes starting 90 minutes post-injection, following the completion of his routine diagnosis. Data were collected in a triggerless mode, enabling the simultaneous registration of annihilation photons and Compton scattered photons. Event selection was based on the position, time, and energy deposition of the annihilation and scattered photons.

The angular distributions between the scattering planes of annihilation photons in the patient's liver and spleen were determined. These distributions were used to extract the degree of quantum entanglement for these organs. The obtained degree of quantum entanglement is larger than expected for separable photons and lower than expected for maximally entangled photons.

These results demonstrate, for the first time, the feasibility of measuring the degree of quantum entanglement in annihilation photons originating from patients during positron emission tomography. This finding motivates the further development of detectors for the construction of PET systems capable of simultaneously capturing annihilation and Compton-scattered photons, and supports future studies aimed at uncovering medically useful information gained by imaging the degree of quantum entanglement.

Acknowledgment

We acknowledge support by National Science Center in Poland (2021/42/A/ST2/00423,2021/43/B/ST2/02150, 2022/47/I/NZ7/03112), Polish Ministry MNiSW (IAL/SP/596235/2023 and SPUB/SP/627733/2025), and European Union through ERC Advanced Grant POSITRONIUM no. 101199807.

References
[1] M. L. H. Pryce and J. C. Ward, Nature 160 (1947) 435.
[2] I. Tkachev et al., Scientific Reports 15 (2025) 6064.
[3] P. Moskal et al., Science Advances 11 (2025) eads3046.
 
[4] P. Moskal, Bio-Algorithms and Med. Systems 22 (2026) 56.
[5] R. Bayerlein et al, Phys. Med. Biol. 71 (2026) 075026.
 
[6] K. Kacprzak et al., Bio-Algorithms and Med. Systems 22 (2026) 36
Keywords: Quantum Entanglement, PET, J-PET, QE-PET
10:15 MIC-12-06

Constraining CP Invariance in Ortho-Positronium Decays at 7 T with NeuroSphere MR-Compatible PET Modules (#3078)

M. S. Allen1, 2, M. Scipioni1, C. Silva2, N. Efthymiou1, M. Hiradfar1, O. Hen2, C. Catana1

1 MGH and Harvard University, A. A. Martinos Center and Harvard Medical School, Cambridge, Massachusetts, United States of America
2 MIT, Physics, Cambridge, Massachusetts, United States of America

Abstract

In addition to medical imaging applications, Positron Emission Tomography (PET) systems can be used to study fundamental physics. One pathway for positron-electron annihilation is the formation of ortho-positronium (oPs), an intermediate bound state that decays to photons after a short lifetime. The lifetime and decay kinematics of oPs can be used to probe material properties and test the Standard Model. Additional sources of charge conjugation-parity (CP) symmetry violation are required to explain the observed matter-antimatter imbalance in the Universe, and CP violation can be constrained by measuring  decays under the reversal of an applied magnetic field. A dedicated physics measurement platform was constructed from the architecture of the NeuroSphere brain PET insert for 7-T MRI, including a PET detector array, positronium target with lifetime trigger, and motorized gantry for control of the system orientation inside the 7-T environment. GATE simulations were used to inform the development of a custom data analysis pipeline for oPs event selection and multi-coincidence processing. Systematics were mitigated by combining runs with various target and detector positions (to average out artificial asymmetries caused by assembly or detector efficiency) and by applying a baseline correction from events in a kinematic region with vanishing analyzing power (to account for drift and more field- and material- related effects).  decays in polyvinyltoluene (PVT) were measured at 7 T, finding a lifetime of 98.7 ± 1.0 ns and constraining CP violation to be zero at a level of 2 × 10−2. This work demonstrates the unique opportunity provided by PET/MR instrumentation to perform high-field physics measurements, a pathway toward a leading measurement of CP violation in positronium, and proof-of-concept for measuring positronium decays with the full NeuroSphere system.

Acknowledgment

This project is funded by the NIH BRAIN Initiative, 1U01EB029826-01.

References
[2] Moskal, P., Bilewicz, A., Das, M., Huang, B., Khreptak, A., Parzych, S., Qi, J., Rominger, A., Seifert, R., Sharma, S., Shi, K., Steinberger, W. M., Walczak, R., & Stępień, E. (2025). Positronium Imaging: History, Current Status, and Future Perspectives. IEEE Transactions on Radiation and Plasma Medical Sciences, 9(8), 981–1001. https://doi.org/10.1109/TRPMS.2025.3583554
[3] Moskal, P., Gajos, A., Mohammed, M., Chhokar, J., Chug, N., Curceanu, C., Czerwiński, E., Dadgar, M., Dulski, K., Gorgol, M., Goworek, J., Hiesmayr, B. C., Jasińska, B., Kacprzak, K., Kapłon, Ł., Karimi, H., Kisielewska, D., Klimaszewski, K., Korcyl, G., … Wiślicki, W. (2021). Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography. Nature Communications, 12(1), 5658. https://doi.org/10.1038/s41467-021-25905-9
[1] Yamazaki, T., Namba, T., Asai, S., & Kobayashi, T. (2010). Search for C P Violation in Positronium Decay. Physical Review Letters, 104(8), 083401. https://doi.org/10.1103/PhysRevLett.104.083401
[6] Rauscher, L. U., Allen, M. S., Judenhofer, M. S., Byars, L., Scipioni, M., Udias, J. M., Catana, C., Pichler, B. J., & Schmidt, F. P. (2025). Impact of DOI Capability on Detector Performance: A Comparative Study of DOI and Non-DOI Detectors for High-Resolution and Sensitivity Organ-Specific PET Inserts. IEEE Transactions on Radiation and Plasma Medical Sciences, 1–1. https://doi.org/10.1109/TRPMS.2025.3624609
[4] Scipioni, M., et al. (2025). Manufacturing and Assembly of the NeuroSphere PET Insert for the Human Dynamic NeuroChemical Connectome. IEEE NSS MIC RTSD. 
[5] Allen, M. S., et al. (2024). Coincidence Timing Performance Optimization of the Detector for the Human Dynamic NeuroChemical Connectome Scanner. IEEE NSS RTSD MIC.
Keywords: positron emission tomography, positronium, magnetic resonance imaging, symmetry violation, detector physics
10:30 MIC-12-07

Novel Spatial Encoding Using Larmor Precession in Nuclear Medicine: A Study on Imaging Robustness (#1753)

H. Suzuki1, B. Feng2, M. Fushimi3, K. Shimazoe2, H. Takahashi2, M. Sekino4

1 The University of Tokyo, Department of Electrical Engineering and Information Systems Graduate School of Engineering, Bunkyo, Japan
2 The University of Tokyo, Department of Nuclear Engineering and Management, Department of Bioengineering, and Institute of Engineeing Innovation, Bunkyo, Japan
3 Keio University, Department of Applied Physics and Physico-Informatics, Faculty of Science and Technology, Bunkyo, Japan
4 The University of Tokyo, Department of Bioengineering, School of Engineering, Yokohama, Japan

Abstract

In nuclear medicine, positron emission tomography (PET) and single photon emission computed tomography (SPECT) exhibit high detection sensitivity by detecting γ-rays emitted from radiopharmaceuticals, but they are limited by poor spatial resolution. Conversely, Magnetic Resonance Imaging (MRI) achieves high spatial resolution by encoding positional information through Larmor precession induced by magnetic field gradients. To improve the spatial resolution in nuclear medicine, we propose a novel image reconstruction framework that integrates magnetic field–based spatial encoding, as utilized in MRI, with γ-ray detection as employed in PET and SPECT.
By incorporating the effect of Larmor precession in perturbed angular correlation (PAC), we formulated a forward model that enables image reconstruction as an inverse problem. Numerical simulations demonstrated that our method can stabilize 7 by 7pixels imaging on a small-animal scale. Furthermore, condition number analysis revealed that the imaging process becomes increasingly stable as the neodymium magnets are scanned. However, since each magnetic field distribution requires several hours of measurement, future work will focus on designing more detailed field distributions to reduce measurement time while further enhancing spatial resolution.

AcknowledgmentThis work was supported by JSPS KAKENHI Grant Number 22H04961. 
References
[1] S. L. Pimlott and A. Sutherland, “Molecular tracers for the PET and SPECT imaging of disease,” vol. 40, no. 1. in Chem. Soc. Rev., no. 40, vol. 40. Royal Society of Chemistry (RSC), 2011.
[2] Y. Zheng, G. W. Miller, W. A. Tobias, and G. D. Cates, “A method for imaging and spectroscopy using γ-rays and magnetic resonance,” vol. 537, no. 7622. in Nature, no. 537, vol. 537. Springer Science and Business Media LLC, Sep. 01, 2016.
[3] G. Schatz and A. Weidinger, “Nuclear Condensed Matter Physics: Nuclear Methods and Applications,” 2nd ed. John Wiley & Sons, 1996. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 1053, 2023, 168305, ISSN 0168-9002.
[4] R. M. Sterzex, “Influence of the Time-Dependent Quadrupole Interaction on the Directional Correlation of the Cd111 Gamma Rays.” 1956.
Keywords: Image reconstruction, Magnetic resonance imaging, Perturbed angular correlation, Tomographic gamma scanning
10:45 MIC-12-08

Real-Time Task-Based Adaptive SPECT Imaging via Optimized System Sampling Strategies Using a Robotic Clinical SPECT Platform (#2916)

Y. Jin1, L.-J. Meng1, 2

1 University of Illinois at Urbana and Champaign, Department of Nuclear, Plasma, and Radiological Engineering, Urbana, Illinois, United States of America
2 University of Illinois at Urbana and Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States of America

Abstract

Task-based adaptive SPECT imaging has long been limited by the computational complexity associated with optimizing acquisition strategies over high-dimensional system configuration spaces. In this work, we present a computational framework for adaptive SPECT imaging based on direct optimization of imaging time distribution (ITD) over discretized detector poses. We have demonstrated the effectiveness of this scheme on a simulated robotic SPECT platform. The framework finds the best imaging strategy by finding an optimized imaging noise property based on the modified uniform Cramér–Rao bound (MUCRB). We further improve the computation efficiency using a non-uniform object-space pixelation (NUOP), which makes it possible to compute the optimum imaging geometry in real time. A StarGuide-inspired multi-head robotic SPECT was simulated and evaluated using a Hoffman brain phantom and hot- and cold-rod resolution-phantoms. Compared with conventional whole-view and uniform ITDs under identical total acquisition time, the optimized ITDs achieved substantially improved region-of-interest (ROI) image quality in all three phantoms and ROIs. These results demonstrate that the proposed framework enables efficient task-specific optimization of acquisition strategies for highly reconfigurable SPECT systems.

Acknowledgment

This work was supported by NIH under grant numbers R01HL145786 (NHLBI) and U01EB031798 and UH3EB034715 (National Institute of Biomedical Imaging and Bioengineering).

References
[1] A. Zorz et al., “Performance evaluation of the 3D-ring cadmium–zinc–telluride (CZT) StarGuide system according to the NEMA NU 1-2018 standard,” EJNMMI Phys., vol. 11, no. 1, p. 69, Jul. 2024, doi: 10.1186/s40658-024-00671-x.
[2] H. H. Barrett et al., “Adaptive SPECT,” IEEE Trans. Med. Imaging, vol. 27, no. 6, pp. 775–788, Jun. 2008, doi: 10.1109/TMI.2007.913241.
[3] E. Clarkson, M. A. Kupinski, H. H. Barrett, and L. Furenlid, “A task-based approach to adaptive and multimodality imaging,” Proc. IEEE, vol. 96, no. 3, pp. 500–511, 2008, doi: 10.1109/JPROC.2007.913073.
[4] M. A. Kupinski, J. W. Hoppin, E. Clarkson, and H. H. Barrett, “Ideal-observer computation in medical imaging with use of Markov-chain Monte Carlo techniques,” JOSA A, vol. 20, no. 3, pp. 430–438, Mar. 2003, doi: 10.1364/JOSAA.20.000430.
[5] L.-J. Meng and N. Li, “SPECT system optimization against a discrete parameter space,” Phys. Med. Biol., vol. 58, no. 9, p. 3037, 2013, doi: 10.1088/0031-9155/58/9/3037.
[6] A. Lin, L. C. Johnson, S. Shokouhi, T. E. Peterson, and M. A. Kupinski, “Using the Wiener estimator to determine optimal imaging parameters in a synthetic-collimator SPECT system used for small animal imaging,” in Medical Imaging 2015: Image Perception, Observer Performance, and Technology Assessment, SPIE, Mar. 2015, pp. 124–131. doi: 10.1117/12.2082971.
Keywords: Fisher information matrix, Adaptive Imaging, SPECT, Cramér–Rao bound