Multi-modality imaging systems including applications and High resolution imaging systems (organ-dedicated, small animal systems) (2)

Session chair: Schulz, Volkmar, (RWTH Aachen University, Institute of Imaging and Computer Vision and Imaging, Aachen, Germany); Efthimiou, Nikos, Dr. (UMCG, Department of Nuclear Medicine, Groningen, Netherlands)
 
Shortcut: MIC-07
Date: Thursday, 12 November, 2026, 11:30 - 12:45
Location: MANUEL DE FALLA
Session type: MIC Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

11:30 MIC-07-01

Experimental Feasibility of Dual-Mode C-arm CT/SPECT Imaging Using a Commercial X-ray Detector for Online Brachytherapy Delivery Verification (#1805)

S. Sung1, H.-J. Choi2, S.W. Jeong2, S.H. You2, C.H. Min1

1 Yonsei University, Department of Radiation Convergence Engineering, Wonju, Republic of Korea
2 Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital, Department of Radiation Oncology, Wonju, Republic of Korea

Abstract

Online brachytherapy delivery verification requires two complementary capabilities: anatomical verification of the applicator prior to irradiation and dynamic tracking of the radioactive source during dose delivery. This study experimentally evaluated the feasibility of a dual-mode C-arm CT/SPECT imaging concept using a single commercially available X-ray flat-panel detector. The core paradigm repurposes a standard X-ray detector into a shared hardware platform: an uncollimated mode for structural visualization, and a collimator-attached mode for radioactive source tracking. The experimental setup utilized a DRTECH EXT1616R digital detector. In the uncollimated X-ray mode, projection images of a PMMA–agar phantom containing a two-ovoid applicator were acquired at 90 kV and 10 mAs during rotational acquisition. The acquired projections successfully distinguished the applicator, air cavities, and phantom tissue surrogate layers. For the SPECT mode, a parallel-hole tungsten collimator was attached to the identical detector. Projection frames of a 58.12 GBq Co-60 source were acquired continuously at 1 frame/s during rotation. Following image intensity enhancement, the Co-60 source profile yielded full width at half maximum values of 3.80 mm and 2.91 mm in the x and y directions, respectively. Furthermore, to demonstrate the ultimate clinical utility of this dual-mode concept, a high-quality reference CT image of a patient-specific 3D-printed pelvic phantom was overlaid with the reconstructed SPECT source distribution, successfully illustrating CT/SPECT fusion feasibility. These findings robustly support the experimental viability of utilizing a commercial X-ray detector for both anatomical assessment and frame-based source delivery verification.

AcknowledgmentThis work was supported by NRF/MSIT, Republic of Korea (RS-2025-25438965), and the Gangwon RISE program (2025-RISE-10-006).
References
[1] P. Georg et al., “Dose-volume histogram parameters and late side effects in magnetic resonance image-guided adaptive cervical cancer brachytherapy,” Int. J. Radiat. Oncol. Biol. Phys., vol. 79, no. 2, pp. 356–362, 2011, 10.1016/j.ijrobp.2009.11.002
[2] S. Sung et al., “Feasibility of internal-source tracking with C-arm CT/SPECT imaging with limited-angle projection data for online in vivo dose verification in brachytherapy: A Monte Carlo simulation study,” Brachytherapy, vol. 22, no. 5, pp. 673–685, 2023, 10.1016/j.brachy.2023.05.003
Keywords: Brachytherapy, delivery verification, dual-mode imaging, C-arm CT/SPECT, source tracking
11:45 MIC-07-02

Development of Biological Microenvironment Imaging Technique Using 111In Cascade Gamma-Ray Correlation (#3120)

B. Feng1, M. Hamdan2, T. Tatsumi3, S. Miyao3, A. Sugiyama5, M. Uenomachi4, H. L. Mizuno4, Y. Anraku4, N. Akimitsu3, K. Shimazoe1

1 The University of Tokyo, Graduate School of Engineering, Tokyo, Japan
2 Fukushima Institute for Research, Education and Innovation (F-REI), Fukushima, Japan
3 The University of Tokyo, Isotope Science Center, Tokyo, Japan
4 Institute of Science Tokyo, Tokyo, Japan
5 Hoshi University, Tokyo, Japan

Abstract

This study explores nuclear medicine imaging toward visualization of both radiotracer distribution and microscopic chemical environment using 111In cascade gamma-ray correlation. PAC coefficients of 111In-labeled agents were quantitatively evaluated under different pH conditions to assess local chemical-environment sensitivity. Cell experiments using 111In-labeled molecular probes were performed to examine applicability to biological samples. In vivo DPECI visualized 111In-labeled agent biodistribution in mice, showing liver and tumor signals consistent with ex vivo organ biodistribution. These results provide a basis for future multimodal imaging that integrates PAC-derived microscopic chemical information with DPECI-based spatial visualization.

Keywords: Cascade gamma rays, Angular correlation, DPECI
12:00 MIC-07-03

SmartBrain-EEG: First-in-Human Wearable PET/EEG Imaging in Epilepsy (#2207)

H. Liu1, 2, W. Qu1, Y. Lin1, K. Hu1, 2, X. Yu1, D. Liang1, Y. Lin1, X. Zhang1, J. Tao1, D. Shi1, W. Li1, H. Zhao1, Y. Zhang1, Q. Peng1

1 Shenzhen Bay Laboratory, Institute of Biomedical Engineering, Shenzhen, China
2 Harbin Institute of Technology, College of Artificial Intelligence, harbin, China

Abstract

In presurgical epilepsy evaluation, noninvasive localization remains challenging in patients with negative or suspicious magnetic resonance imaging findings or inconsistent multimodal results. Positron emission tomography provides metabolic information, while electroencephalography records abnormal electrical activity. However, conventional fixed PET systems usually require supine and constrained positioning, limiting simultaneous monitoring during seizure-related states, task conditions, or near-natural behaviors. To address this limitation, we integrated scalp electroencephalography with an ultra-light wearable motion-following brain PET system to evaluate the feasibility of simultaneous metabolic-electrophysiological imaging in epilepsy subjects. Compatibility was first assessed using an electroencephalography-equipped brain phantom. Phantom images acquired with and without electroencephalography electrodes showed comparable structures, and electroencephalography waveforms remained interpretable with and without PET operation. Initial human evaluation was then performed in an epilepsy patient. Wearable brain PET imaging and simultaneous wearable PET/EEG acquisition were successfully completed. During prolonged acquisition, the subject fell asleep, causing detector displacement and motion artifacts in reconstructed PET images. These results demonstrate the technical feasibility of simultaneous wearable metabolic-electrophysiological brain imaging and highlight the need for improved fixation, motion tracking, and motion correction in future natural-state neuroimaging studies.

AcknowledgmentThis work was supported by the National Natural Science Foundation of China (Grant no. 82327809), the National Key Research and Development Program of China (Grant No. 2024YFF0507700), National High-Level Hospital Clinical Research Funding (2025-PUMCH-D-003), Beijing Natural Science Foundation(L252047).
References
[1] Traub-Weidinger, T, Arbizu, J, Barthel, H et al. 2024, ‘EANM practice guidelines for an appropriate use of PET and SPECT for patients with epilepsy’, European Journal of Nuclear Medicine and Molecular Imaging, vol. 51, pp. 1891–1908.
[2] Grouiller, F, Thornton, K, Groening, A et al. 2015, ‘All-in-one interictal presurgical imaging in patients with epilepsy: single-session EEG/PET/(f)MRI’, European Journal of Nuclear Medicine and Molecular Imaging, vol. 42, pp. 1133–1143.
[3] Liu, H, Qu, W, Liang, D et al. 2026, ‘Performance Evaluation of SmartBrain: A Wearable PET System for Human Brain Imaging’, Journal of Nuclear Medicine.
[4] Rajkumar, R, Rota Kops, E, Mauler, J et al. 2017, ‘Simultaneous trimodal PET-MR-EEG imaging: Do EEG caps generate artefacts in PET images?’, PLOS ONE, vol. 12, no. 9, e0184743.
Keywords: Electroencephalography, epilepsy, positron emission tomography, SmartBrain, wearable imaging
12:15 MIC-07-04

Human Subject and Phantom Imaging Performance of PETcoil Gen II Brain-Dedicated PET System (#2894)

G. H.-S. Park1, M. N. Ullah1, G. Chinn1, C. S. Levin1

1 Stanford University, Radiology, Stanford, California, United States of America

Abstract

PETcoil Gen II is a second-generation RF-penetrable time-of-flight (TOF) positron emission tomography (PET) brain insert designed for simultaneous PET/MRI. We evaluated initial imaging performance using a 3D Hoffman brain phantom and present the first clinical ¹⁸F-FDG brain PET images acquired with the system. Randoms correction was performed using delayed-window (DW) estimates. A computed tomography (CT)-based attenuation (μ) map was generated and extrapolated to 511 keV using piecewise linear interpolation, while scatter fractions were estimated via OpenSSS. In the Hoffman phantom and research subject scan, full corrections improved signal-to-background ratio from 3.48 to 4.50 and from 2.69 to 3.20, respectively, with improved visualization of cortical and subcortical structures. These results indicate that the correction methods are functioning and demonstrate the ability of the PETcoil Gen II to produce high-quality images.

AcknowledgmentThis work was supported in part by NIH-NIBIB grant #5R01EB03103804. The authors thank Dr. Qian Dong for foundational contributions to the PETcoil Gen II system, Martin Schneider, our clinical coordinator for this study, and the patient who participated in this first clinical scan.
References
[1] Q. Dong et al. 2024, ‘Article’, Physics in Medicine & Biology, 69, 185007, Bristol: IOP Publishing
[2] Ullah, MN 2024, ‘Data Correction and Imaging Studies for PETCoil: A Second-Generation RF-Penetrable Brain TOF-PET Insert for Simultaneous PET/MRI’, IEEE NSS/MIC/RTSD, Piscataway: IEEE
[3] Williams, CW et al. 1979, ‘Article’, Journal of Nuclear Medicine, 20, 695–696, Reston: Society of Nuclear Medicine
[4] Hudson, HM et al. 1994, ‘Article’, IEEE Transactions on Medical Imaging, 13, 601–609, Piscataway: IEEE
Keywords: PET/MRI, Time-of-flight PET, Brain imaging, Scatter correction, Hoffman phantom
12:30 MIC-07-05

Development of SIAT 9.4T MRI compatible animal PET scanner (#1791)

H. Li1, H. Huang1, S. Yang1, Z. Kuang1, N. Ren1, Z. Hu1, Y. Yang1, Z. Liu1

1 Chinese Academy of Sciences,, Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Shenzhen, China

Abstract

This study aims to develop a 9.4 T MRI-compatible small-animal PET insert with sub-millimeter spatial resolution and system-level magnetic compatibility. The PET insert consists of 84 dual-ended readout detector arrays arranged in 7 axial rings, with 12 detector modules per ring. Each detector array contains a 28 × 28 LYSO crystal matrix with a crystal size of 0.75 × 0.75 × 20 mm³. Compact front-end amplification electronics, row-column multiplexed readout, non-magnetic mechanical support, and inner/outer carbon-fiber tubes were integrated to meet the spatial and electromagnetic compatibility requirements of a 9.4 T MRI scanner. Point-source imaging was performed to evaluate spatial resolution. A prototype PET insert was developed and integrated. 22Na point-source images reconstructed using OSEM with 5 iterations demonstrated sub-millimeter spatial resolution, indicating high-resolution imaging capability for 9.4 T small-animal PET/MRI applications.

AcknowledgmentThis work is supported by the National Key Research and Development Program of China (2023YFF0716000), the National Natural Science Foundation of China (Grant No. 12375358), the Shenzhen Science and Technology Program (JCYJ20220531100000001, JCYJ20220818101804009).
References
[1] R. S. Miyaoka and A. L. Lehnert, "Small animal PET: a review of what we have done and where we are going," Physics in Medicine & Biology, vol. 65, no. 24, p. 24TR04, 2020.
[2] G. Stortz et al., "Performance of a PET insert for high-resolution small-animal PET/MRI at 7 tesla," Journal of Nuclear Medicine, vol. 59, no. 3, pp. 536-542, 2018.
[3] Z. Kuang et al., "Design and performance of SIAT aPET: a uniform high-resolution small animal PET scanner using dual-ended readout detectors," Physics in Medicine & Biology, vol. 65, no. 23, p. 235013, 2020.
[4] Z. Kuang et al., "Development and performance of SIAT bPET: a high-resolution and high-sensitivity MR-compatible brain PET scanner using dual-ended readout detectors," European Journal of Nuclear Medicine and Molecular Imaging, vol. 51, no. 2, pp. 346-357, 2024.
Keywords: PET/MRI, 9.4 T MRI, small-animal PET, MRI-compatible detector, PET image reconstruction