High resolution imaging systems (organ-dedicated, small animal systems (1)
Session chair:
Ma, Tianyu, (Tsinghua University, Department of Engineering Physics, Beijing, China); Zannoni, Elena Maria, Dr. (The University of Texas at Austin, Austin, USA)
Shortcut:
MIC-02
Date:
Wednesday, 11 November, 2026, 11:30 -
12:45
Location:
MANUEL DE FALLA
Session type:
MIC Session
Contents
Click on an contribution to preview the abstract content.
The underlined authors are the presenters. The authors in bold are the main authors.
11:30
MIC-02-01
Development and Evaluation of Gym-PET for Functional Brain Imaging of Awake Running Mice (#2398)
X. Yu1, H. Liu1, D. Liang1, W. Zhu1, W. Ma1, Y. Zhang1, J. Tao1, H. Zhao1, Q. Peng1
1 Shenzhen Bay Laboratory, Shenzhen, China
Abstract
Awake functional brain imaging is crucial for behavioral neuroscience, but conventional preclinical PET scanners typically require anesthesia, which suppresses brain glucose metabolism and limits natural behavioral studies. To address these limitations, we developed Gym-PET, a 75 g head-mounted wearable PET system optimized for awake running mice.
The wearable module features a compact detector ring (20.0 mm inner diameter) composed of 1 x 1 x 5 mm³ LYSO crystal arrays coupled to SiPMs, a short crystal design chosen to minimize parallax degradation under close-range conditions. To enable stable imaging during locomotion, the scanner is integrated with a customized treadmill platform using a lightweight suspension mechanism. Based on the NEMA NU-4 2008 standard, the system achieved 12.5% energy resolution, 0.8% peak sensitivity, and a high spatial resolution of 0.66 mm. Compared to conventional preclinical PET systems, Gym-PET demonstrated visibly improved delineation of small subcortical structures.
To validate the system's in vivo capabilities, dynamic 18F-FDG PET imaging was performed. The results successfully captured exercise-induced metabolic activation in the brainstem and thalamus of awake running mice. Furthermore, a three-day sleep deprivation study revealed the system's sensitivity to global metabolic suppression without anesthesia interference. Ultimately, the Gym-PET platform significantly reduces anesthesia-related metabolic interference, establishing a highly effective tool for high-resolution molecular neuroimaging in awake behavioral models.
AcknowledgmentThis work was supported by the National Natural Science Foundation of China (Grant no. 82327809), the National Key Research and Development Program of China (Grant No. 2024YFF0507700 ), National High-Level Hospital Clinical Research Funding (2025-PUMCH-D-003), Beijing Natural Science Foundation(L252047).
References [1] A. Miranda, D. Glorie, D. Bertoglio et al., “Awake 18f-fdg pet imaging of memantine-induced brain activation and test–retest in freely running mice,” Journal of Nuclear Medicine, vol. 60, no. 6, pp. 844–850, 2019. [2] A. Miranda, S. Staelens, S. Stroobants et al., “Fast and accurate rat head motion tracking with point sources for awake brain pet,” IEEE transactions on medical imaging, vol. 36, no. 7, pp. 1573–1582, 2017. [3] X. Yu, Z. Zhao, H. Liu, D. Liang, W. Zhu, Y. Lin, J. Zeng, C. Liu, J. Xu, S. Xie, W. Wang, and Q. Peng, “Development and performance evaluation of a benchtop small-animal pet/mri scanner,” IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 9, no. 8, pp. 1118–1126, 2025.
Keywords: Awake Functional Brain Imaging, Wearable PET
11:45
MIC-02-02
Preliminary Validation of Flexible On-Demand Customized Ultra-Resolution System for Targeted Performance Enhancement in Preclinical PET (#3184)
K. Wang1, R. Liao1, Z. Yuan1, Y. Chen1, Y. Chen1, H. Wen1, C. Li1, Y. Hou1, S. Gong1, Y. Tai2, J. Jiang1
1 Beijing Normal University, Beijing, China 2 Washington University in St. Louis, Mallinckrodt Institute of Radiology, St. Louis, Missouri, United States of America
Abstract
This study introduces Flexible On-demand Customized Ultra-resolution System for PET (FOCUS-PET), a novel technique designed to maximize spatial resolution and counting statistics within a predefined region of interest. The efficacy of FOCUS-PET was rigorously evaluated via Monte Carlo simulations and physical experiments using high-resolution add-on detector configurations. The simulated system employed an arc-shaped add-on detector comprised of a 4×2 module array, with each module housing 32×48 LYSO crystals (0.42×0.42×5.0 mm³). Sensitivity profiles were mapped using an axially stepped 22Na point source, and a three-bed whole-body protocol was simulated utilizing a micro-Derenzo phantom. Simulation results demonstrated a 5.1% to 19.8% enhancement in absolute sensitivity. The system resolved 0.9-mm micro-rods, effectively surpassing native resolution limits, and improved the peak-to-valley ratio (PVR) and contrast recovery (CR) for 1.0-mm rods from 1.50 to 2.13 and 33.30% to 52.95%, respectively. Experimental validation was performed by integrating a flat-panel add-on detector—comprising two modules with 44×44 LYSO arrays (0.52×0.52×5.0 mm³)—into an ACTIVE 7 MAX preclinical scanner. Imaging of a physical Derenzo phantom was conducted to assess ultimate resolution and multi-bed stitching fidelity. Physical experiments corroborated the theoretical gains, with the flat-panel FOCUS-PET device consistently improving PVR (1.57 to 1.90) and CR (27.93% to 33.19%) for 1.25-mm hot rods compared to the baseline. In conclusion, FOCUS-PET significantly elevates system sensitivity and spatial resolution, providing a cost-effective pathway for ultra-high-resolution preclinical imaging and potential translation to clinical whole-body PET applications.
Acknowledgment
This work was supported in part by the National Natural Science Foundation of China (No. 12475336), and the Fundamental Research Funds for the Central Universities (No. 310400209521).
References [1] S. Surti, Journal of Nuclear Medicine, vol. 56, pp. 98-105, Jan 2015. [2] M. Janecek, et al., IEEE Transactions on Nuclear Science, vol. 53, pp. 1143-1149, 2006. [3] M. Janecek, et al., IEEE Transactions on Nuclear Science, vol. 53, pp. 1143-1149, 2006. [4] Z. Yuan, et al., Medical Physics, vol. 53, no. 1, pp. e70216, 2026.
Initial Performance Characterization of the SAVANT Ultra-High-Resolution Phoswich-Based DOI Brain PET Scanner (#2935)
R. Lecomte1, 5, Y. Najmaoui4, 2, M. Gaudreault1, O. Sarrhini3, J.-F. Beaudoin3, T. Galarneau3, É. Croteau3, É. Lavallée3, C. Thibaudeau5, R. Espagnet4, N. Viscogliosi4, J. Bouchard4, A. Samson4, M. Toussaint6, T. Marin2, Y. Chemli2, J.-B. Michaud4, M.-A. Tétrault4, R. Fontaine4, G. El Fakhri2
1 Université de Sherbrooke, Sherbrooke Molecular Imaging Center and Department of Medical Imaging and Radiation Sciences, Sherbrooke, Québec, Canada 2 Yale University School of Medicine, Yale Biomedical Imaging Institute, New Haven, Connecticut, United States of America 3 CRCHUS, Sherbrooke Molecular Imaging Center, Sherbrooke, Québec, Canada 4 Université de Sherbrooke, Interdisciplinary Institute for Technological Innovation – 3IT, Sherbrooke, Québec, Canada 5 Imaging Research and Technology (IR&T) Inc., Magog, Québec, Canada 6 Nantes Université, Laboratoire CRCI2NA, INSERM, CNRS, Nantes, France
Abstract
High spatial resolution is essential to resolve small structures in the brain and to enable imaging of neurological pathways at the onset of diseases. A key challenge with ultra-high-resolution (UHR) PET scanners is the significant degradation of resolution that occurs beyond the central area of the field-of-view (FOV). The UHR Brain PET scanner was designed with short (12 mm) LYSO crystals to mitigate the parallax error off the FOV center, but at the expense of reduced sensitivity. To address these limitations, the LabPET II technology platform was upgraded to implement depth-of-interaction (DOI) measurement using longer (15 mm) dual LGSO phoswich detectors in the SAVANT. Simulation results indicate an estimated 40% gain in sensitivity, while maintaining the resolution below 2 mm FWHM at the edge of the brain. For DOI determination, the crystal identification between slow (43-48 ns decay time) and fast (30-35 ns decay time) LGSO scintillators uses a model-based dual-threshold time-over-threshold (ToT) discrimination technique, currently achieving better than 70% accuracy. The 6.5/8.5 mm length ratio of the top slow and bottom fast LGSO scintillators resulted from trade-offs between off-center spatial resolution and balanced coincidence detection efficiency of the two crystal layers. We report the initial experimental characterization of the partially assembled scanner (182 mm axial extent), which demonstrate the improvement in sensitivity and resolution uniformity across the radial FOV achieved using this simple DOI discrimination scheme. Point source and phantom measurements taken at various radial positions demonstrate the gain in spatial resolution compared to non-DOI measurements, though not reaching the resolution predicted by simulation. Further refinement of the crystal identification process using AI-based classification is expected to yield the forecasted benefits from simulation. Preliminary results for imaging the human brain will be presented.
References [1] Gaudin, É., Toussaint, M., Thibaudeau, C., Paille,M., Fontaine, R., Lecomte, R., “Performance Simulation of an Ultrahigh Resolution Brain PET Scanner Using 1.2-mm Pixel Detectors,” IEEE Trans. Radiat. Plasma Med. Sci., vol. 3, no. 3, pp. 334–342, May 2019, doi: 10.1109/TRPMS.2018.2877511. [2] Émilie Gaudin, Maxime Toussaint, Christian Thibaudeau, Réjean Fontaine, Marc D. Normandin, Yoann Petibon, Jinsong Ouyang, Georges N. El Fakhri, Roger Lecomte.“Simulation studies of the SAVANT high resolution dedicated brain PET scanner using indi vidually coupled APD detectors and DOI encoding”. Society of Nuclear Medicine and Molecular Imaging (SNMMI) 2019 Annual Meeting, Anaheim, CA, 22-25 June 2019. (Journal of Nuclear Medicine, vol. 60, suppl. 1, p. 531, 1st May 2019) [3] Émilie Gaudin, Maxime Toussaint, Christian Thibaudeau, Étienne Croteau, Réjean Fontaine, Marc D. Normandin, Yoann Petibon, Jinsong Ouyang, Georges El Fakhri, Roger Lecomte. “SAVANT: a high resolution APD-based dedicated brain PET scanner with DOI encoding”. 2019 IEEE Nuclear Science Symposium & Medical Imaging Conference, Paper ID #2392, M-06-086, Manchester, UK, 26 October - 2 November 2019. [4] Haithem Bouziri, Catherine M. Pepin, Konin Koua, Maher Benhouria, Caroline Paulin, Jinsong Ouyang, Marc Normandin, Jean-François Pratte, Georges El Fakhri, Roger Lecomte, Réjean Fontaine. “Investigation of a model-based time-over-threshold technique for phoswich crystal discrimination”. Haithem Bouziri, Catherine M. Pepin, Konin Koua, Maher Benhouria, Caroline Paulin, Jinsong Ouyang, Marc Normandin, Jean-François Pratte, Georges El Fakhri, Roger Lecomte, Réjean Fontaine. IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 6, no. 4, pp. 393-403, 1st April 2022. (DOI: 10.1109/TRPMS.2021.3077412)
A Physics-Guided Deep Learning Method for Fast System Matrix Modeling in Self-Collimating SPECT Using Sparse Point-Source Calibration (#2412)
Q. Ye1, D. Zhang1, H. Xie2, Z. Lyu1, T. Ma1
1 Tsinghua University, Beijing, China 2 Fudan University, Shanghai, China
Abstract
Self-collimating SPECT (SC-SPECT) enables simultaneous high-resolution and high-sensitivity imaging using sparse-scintillator detector layers. Accurate system matrix (SM) estimation is essential but remains challenging in SC-SPECT, because dense point-source calibration is time-consuming and conventional modeling is limited by complex system physics, while geometry-dependent detector responses further complicate AI-based sparse-to-dense recovery. In this work, we propose a physics-guided sparse-to-dense SM modeling framework to recover the full SM from 10k point-source measurements. The framework uses a customized 3D encoder–decoder with anisotropic convolutions and modified down/up-sampling to preserve fine structures under limited sampling. Sparse response intensity, sampling positions, and detector angular information are encoded as four input channels, while LOR-directional profile and curvature-continuity losses enforce physically consistent recovery. The model is trained on simulated PPDFs, with ablation studies evaluating the input-channel, architecture, and loss designs. It is further validated using experimental SM-level metrics and MLEM reconstructions of hot-rod phantom and small-animal data. Results demonstrate improved PPDF recovery and reconstruction quality over interpolation-based SM estimation and a standard U-Net, while reducing the calibration time by over 97.5%.
References [1] T. Ma, et al. Self-Collimating SPECT With Multi-Layer Interspaced Mosaic Detectors. IEEE TMI, 2021. [2] D. Zhang, et al. A High-Performance Self-Collimation SPECT for Small Animal Imaging. IEEE TMI, 2026. [3] D. Zhang, et al. Characterization and Assessment of Projection Probability Density Function and Enhanced Sampling in Self-Collimation SPECT. IEEE TMI, 2023.
Keywords: SPECT, self-collimation, system modeling, physics-guided learning
12:30
MIC-02-05
BuckyPET: Performance Evaluation and NEMA Adaptation for Compact PET Geometries (#3115)
D. Perez-Benito1, L. Batres1, L. Jimenez Algarra1, M. Vidal1, J. J. Vaquero1, 2
1 Universidad Carlos III de Madrid, Departamento de Bioingenería, Madrid, Spain 2 Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain
Abstract
Dedicated brain PET systems are attracting renewed interest due to their potential to overcome key limitations of conventional whole-body PET, particularly limited sensitivity and spatial resolution for neurological imaging. In this work, we present BuckyPET, an innovative dedicated brain PET scanner inspired by fullerene-like geometry. The system is based on 234 regular hexagonal LYSO detector modules arranged to closely approximate a spherical configuration, arguably the most efficient geometry for brain PET imaging. Each detector is laser-engraved to create customizable optical barriers defining hexagonal scintillation pixels and is coupled to a hexagonal Hamamatsu MPPC with 61 individually read channels. Current clinical and preclinical NEMA standards rely on concepts such as sinograms, single-slice rebinning, axial axes, and transaxial planes, which are not directly applicable to spherical or highly enclosed geometries. We also discuss the need for a modified NEMA NU 2-2018-like protocol for non-cylindrical PET systems. We propose preserving the core performance metrics of the standard while reformulating the analysis in a geometry-independent framework. Preliminary results demonstrate the high-sensitivity capabilities of BuckyPET, alongside a high noise-to-count ratio and spatial resolution in the range of 1.5-2 mm. Ongoing work focuses on fine-tuning the electronics and acquisition system and assessing robustness under different operating conditions. Thus, the final figures of merit are expected to further improve, while ongoing advances in the reconstruction framework are anticipated to push the spatial resolution beyond the 1 mm frontier. First studies for the clinical validation are scheduled for summer 2026.
References [1] L. Moliner, M. J. Rodríguez-Alvarez, J. V. Catret, A. González, V. Ilisie, and J. M. Benlloch, “NEMA performance evaluation of CareMiBrain dedicated brain PET and comparison with the whole-body and dedicated brain PET systems,” Scientific Reports, vol. 9, pp. 1–10, 2019. [2] H. Tashima, E. Yoshida, F. Nishikido, H. Wakizaka, M. Nitta, A. M. Ahmed, A. Mohammadi, S. Tazawa, Y. Kimura, T. Suhara, Y. Fujibayashi, and T. Yamaya, “Development of the helmet-chin PET prototype,” 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, pp. 1–3, 2015.