IEEE 2026 NSS MIC RTSD

Please note! All times in the online program are given in Madrid - Europe (CET) times!

Madrid - Europe ()
Oct 23, 2026, 6:56:09 PM
Your time ()
n/a
Madrid - Europe ()
Oct 23, 2026, 6:56:09 PM
Our Sponsors:

To search for a specific ID please enter the hash sign followed by the ID number (e.g. #123).

NSS Poster Session

 
Shortcut: NSS-01
Date: Monday, 9 November, 2026, 15:00 - 17:00
Location: Poster Area
Session type: NSS Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

15:00 Poster panel: 1

Poster Number:
NSS-01-001

Fast or Adapt: Proportional Gas in γ-ray Fields (#1278)

J. Prchlik1, E. Yokie1, A. Petitjean1, D. O'Connor1

1 Reuter-Stokes, LLC, Twinsburg, Ohio, United States of America

Abstract

Background γ-ray fields complicate neutron measurements for Nondestructive Assay (NDA) of Nuclear Materials and the next generation of advanced reactor designs, including non-light water (non-LWR) and Small Modular Reactors (SMRs). Neutron sensitive proportional counter design for high γ-ray fields often focus on optimizing ion collection time and integrating low-Z materials. In these counters, the metal cathode produces most of the Compton scattered electrons, which deposit unwanted energy and signal in the gas. The long path length for Compton electrons in the counter gas means the counter gas pressures may be optimized to increase the ratio of ion-to-electron energy deposition. Here we present gas mixture and pressure optimization for ion-to-electron energy deposition using SRIM simulations. The simulation output is then tested experimentally for its effect on neutron sensitivity in γ-ray fields between 1 R/Hr and 100 R/Hr. The ion-to-electron energy deposition ratio shows promise as an additional design consideration for neutron sensitive proportional counters in γ-ray fields, even though the experimentally measured optimum pressure of 0.5 atm for He/N2 95/5 is lower than the simulated optimum pressure. Future experiments with a current sensitive preamplifier (CAEN A1427) will improve neutron counting for 1 to 100 R/Hr γ-ray fields.

References
[1] DH Beddingfield, NH Johnson, and HO Menlove. 3he neutron proportional counter performance in high gamma-ray dose environments. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 455(3):670–682, 2000.
[2] D. C. Henzlova, M. P. Baker, K. Bartlett, A. Favalli, M. Iliev, M. A. Root, S. Sarnoski, T. Shin, and M. T. Swinhoe. Neutron Detectors, pages 325–358. Springer Nature Switzerland, Cham, 2024.
[3] Kevin S McKinny, Thomas R Anderson, and Nathan H Johnson. Neutron detector sensitivity measurements and their variation. In 2011 IEEE Nuclear Science Symposium Conference Record, pages 533–537. IEEE, 2011.
[4] J. Va’Vra. Review of wire chamber aging. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 252(2):547–563, 1986.
Keywords: Gamma-ray effects, Reactor instrumentation, Radiation monitoring, Nuclear instrumentation, Gaseous detectors
15:00 Poster panel: 3

Poster Number:
NSS-01-003

Development of a Monte Carlo Simulation–Based Analysis Technique for High-Pressure Ionization Chambers (HPIC) (#1858)

K.H. Sung1, C.H. Min1, J.-K. Shin2

1 Yonsei University, Department of Radiation Convergence Engineering, Wonju, Republic of Korea
2 NeosisKorea, Daejeon, Republic of Korea

Abstract

High-pressure ionization chambers (HPICs) are widely used for radiation monitoring owing to their high sensitivity and mechanical robustness. However, under low-dose conditions, the inherently small signal results in a low signal-to-noise ratio, making accurate characterization of detector response challenging. Therefore, detailed analysis of radiation interaction and charge transport processes in the detector is required for accurate characterization and optimization of HPIC performance. In this study, a simulation framework was developed to investigate and optimize the signal response characteristics of HPICs. A coupled simulation framework integrating Geant4 and Garfield++ is used to model the full signal formation process, including radiation dose deposition and charge transport under applied electric fields. A Kyocera HPIC was used to measure the current response as a function of applied voltage under irradiation from a 95 μCi Cs-137 source. In the Geant4 simulation, the HPIC geometry was modeled to calculate the spatial distribution of dose deposition within the gas volume, which is subsequently converted into ion pair distributions using the W-value. The electric field is modeled in Garfield++ to simulate charge transport under applied voltages, enabling the calculation of the resulting current response. The collected charge in the anode shows a plateau behavior at approximately 64.2 pA, while the experimental results exhibit a saturation around 54.8 pA. It is predicted that the discrepancy is attributed to additional physical effects such as ion recombination, feedthrough effects, and leakage currents. These findings demonstrate that the proposed approach provides a reliable framework for accurate analysis and optimization of HPIC.

AcknowledgmentThis work was supported by the Nuclear Energy International Joint Research Project through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (MSIT) (No. RS-2025-25396349).
References
[1] G. F. Knoll, Radiation Detection and Measurement, 4th ed. Hoboken, NJ, USA: Wiley, 2010.
[2] D. Pfeiffer, M. J. R. Hoch, S. R. Johnson, and A. Sharma, “Interfacing Geant4, Garfield++ and Degrad for the simulation of gaseous detectors,” Nucl. Instrum. Methods Phys. Res. A, vol. 935, pp. 121–134, 2019.
[3] ICRU, “Mean energy required to produce an ion pair,” ICRU Report 31, Bethesda, MD, USA: International Commission on Radiation Units and Measurements, 1979.
Keywords: High Pressure Ionization Chamber, Monte Carlo Simulation, Detector Response
15:00 Poster panel: 5

Poster Number:
NSS-01-005

High Granularity Readout Time Projection Chamber R&D for Future Circular e+e- Colliders (#2530)

H. Qi1, 2, M. Titov2

1 Institute of High Energy Physics, CAS, Beijing, China
2 Linear Collider Time Projection Chamber International Collaboration, Hamburg, Germany

On behalf of Linear Collider Time Projection Chamber International Collaboration

Abstract

A worldwide Lepton Collider Time Projection Chamber community of the physicists was working to realize an exceptional physics program of the energy-frontier, electron-positron collision, especially for Future Circular Collider (FCC-ee), Circular Electron Positron Collider (CEPC) and the International Linear Collier (ILC). In all proposed detector concepts, the Time Projection Chamber (TPC) serves as the main tracking detector, complemented by the silicon tracking detectors both inside and outside the TPC, all embedded within a 3 T solenoid field. Many extensive R&D program for the track detector has been developed within the collaboration of LCTPC.

TPC performance is satisfactory in Higgs mode, but the high luminosity Z pole running poses substantial technical challenges. Based on MDI background simulation data to study ion-induced space charge effects, we have conducted a detailed assessment of TPC technical challenges and potential solutions, particularly under the high luminosity Z pole running conditions. In this talk, the feasibility and update progress of high precision TPC as the main track detector for e+ e− collider will be presented. TPC detection aims the good separation power with the cluster counting to be considered and the simulation results of the pad/pixelated TPC technology will be given. Compared with the pad readout using the simulation, the high granularity readout TPC options will obtain the better spatial resolution of single electrons, the very high detection efficiency in excellent tracking and good PID performance (less than 3σ).  A large prototype TPC in a 1.0T magnetic field, which allow to accommodate up to seven identical Micro Pattern Gaseous Detector (MPGD) readout modules of the TPC being studied using the 5GeV electron beam at DESY, we will present the track reconstruction performance results and summarize the next steps of the pad/pixelated TPC technology for the future lepton colliders.

Keywords: Time Projection Chamber, Micro-pattern Gaseous Detector, e+e- collider, PID
15:00 Poster panel: 7

Poster Number:
NSS-01-007

A Semi-Analytical Method for Sensitivity Estimation of Parallel-Plate Boron-Coated Ionization Chambers (#3076)

P. Tang1

1 tsinghua university, Institute of Nuclear and New Energy Technology, beijing, China

Abstract

This paper presents a semi-analytical method for sensitivity estimation of multilayer parallel-plate boron-coated ionization chambers. The model combines: (1) an overlap-geometry calculation for the distribution of crossed boron layers under oblique incidence, and (2) a microscopic-simulation-based depth-response function for single-layer effective signal generation. By coupling geometric crossing statistics, boron attenuation, and depth response, detector sensitivity can be rapidly evaluated versus incidence angle, boron thickness, and plate spacing. Compared with Geant4, the method reproduces both trend and magnitude of angular sensitivity, with better agreement at large angles. The framework is suitable for fast parameter screening before high-fidelity simulation.

Keywords: Boron-coated ionization chamber, thermal neutron detection, semi-analytical method, currency sensitivity, Geant4
15:00 Poster panel: 9

Poster Number:
NSS-01-009

A New Efficient n-γ Pulse Shape Discrimination Technique for Fast Scintillation Detectors (#1149)

S. Riboldi1, 2, A. Giaz2, S. Brambilla2, C. Boiano2

1 Università degli Studi di Milano, Fisica, Milano, Italy
2 INFN, Milano, Milano, Italy

Abstract

Pulse shape discrimination (PSD) is an effective technique for identifying the interacting particle (e.g., gamma rays or neutrons) in scintillation detectors.
In the simplest cases (e.g., the Cs2LiYCl6 scintillator, showing a large difference between gamma and neutron signals), the PSD procedure can be performed using the "charge integration" (CI) method, based on rectangular weighting functions. However, for scintillators with smaller differences in signal shape (e.g., the LaCl3:Ce scintillator), different methods must be used.
Moreover, when digital acquisition systems are used, sampling the photodetector’s analog signal at a finite time step can significantly affect the PSD results. Indeed, apart from the effects of electronic and quantization noise, the main cause of overlapping of the PSD regions of interest (ROI) of fast scintillator signals processed in the time domain is the temporal variability (ΔT) of the sampling comb relative to the onset of the analog pulse. In the case of relatively high DAQ's acquisition frequency (e.g., 500 MHz), increasing it further to mitigate this issue is not practical, and alternative techniques must be used.
One solution is to proceed via the absolute value of the discrete Fourier transform (DFT) of the signal, which completely solves the temporal variability issue, though at the cost of significant computational burden.
This paper presents a new analysis technique that solves the problem with a negligible computational overhead, making it especially suitable for online applications, by just linking the information on the time shift ΔT to the detector signal, and linearly filtering the whole dataset.
The filter weighting function is determined with the DPLMS optimal filter synthesis algorithm, employed here for the first time for this purpose.
The PSD results obtained with this technique, suitable as well for energy and time estimations, are here shown for experimentally acquired  LaCl3:Ce scintillator signals.

References
[1] S. Riboldi, et al., 2025, 'Neutron-Gamma Pulse Shape Discrimination Techniques for Scintillation Detectors,' IEEE NSS, Yokohama, Japan, doi: 10.1109/NSS/MIC/RTSD57106.2025.11287487
[2] D. Rigamonti, et al., 2025, 'A chlorine based detector (LaCl3(Ce)) for 2.5 MeV neutron spectroscopy in deuterium nuclear fusion plasmas with enhanced particle discrimination algorithm', Meas. Sci. Technol. 36 (2025), doi: 10.1088/1361-6501/ad8f4e
Keywords: PSD, Neutron-gamma discrimination, DPLMS, LaCl3:Ce scintillator
15:00 Poster panel: 11

Poster Number:
NSS-01-011

Near infrared scintillation properties of rare earth doped fluorapatite transparent ceramics (#1184)

T. Yanagida1, K. Miyajima1, K. Okazaki1, T. Nakanishi2, H. Furuse2, T. Kato1, D. Nakauchi1, N. Kawaguchi1

1 Nara Institute of Science and Technology, Ikoma, Japan
2 NIMS, Tsukuba, Japan

Abstract

Near infrared (NIR) emitting scintillators have attracted attentions recently for radiation monitoring at high dose fields. In this work, NIR scintillation properties of Yb3+ and Nd3+ doped fluorapatite (Ca10(PO4)6F2, FAP) transparent ceramics with different doping concentration were investigated. These materials have been originally developed for laser applications. The most famous laser material, Nd:YAG transparent ceramic, can show good scintillation performance both UV-VIS emission and NIR emission, and following such a study, good performance can be expected in FAP transparent ceramic. When X-rays were irradiated, they exhibited 1000 nm (Yb) and 1064 (band) emission bands, and their scintillation decay time resulted several micro hundreds s. The most important property for high dose field monitoring, the lower detection limit (LDL), was investigated by coupling with InGaAs photodiode. Yb and Nd-doped FAP showed 1.2 and 0.6 mGy/hr, respectively. In the conference, scintillation properties as well as photoluminescence properties will be presented, and compared with other NIR emitting scintillators.

Keywords: scintillator, transparent ceramic, X-ray, optical fiber, InGaAs
15:00 Poster panel: 13

Poster Number:
NSS-01-013

Hydrophobic Solvent-Based Polishing for Performance Enhancement of Water-Sensitive Perovskite Scintillator Crystals (#1236)

S. Song1, 2, J. Seo3, D. Lee1, 2, C. Park4, B. Park5, J.-Y. Yeom2, 6

1 Korea University, Department of Bioengineering, Seoul, Republic of Korea
2 Korea University, Interdisciplinary Program in Precision Public Health, Seoul, Republic of Korea
3 Korea Institute of Fusion Energy, Dajeon, Republic of Korea
4 Korea University, Global Health Technology Research Center, Seoul, Republic of Korea
5 Seoul National University, Research Institute for Future Technology and Policy, Seoul, Republic of Korea
6 Korea University, School of Bioengineering, Seoul, Republic of Korea

Abstract

Halide perovskites are promising scintillator materials for radiation detection and medical imaging because of their excellent optical and scintillation properties. Since the surface quality of single-crystal scintillators strongly affects light extraction and detector performance, polishing is an essential step in scintillator fabrication. However, conventional wet polishing processes are not suitable for water-sensitive crystals such as Cs3Cu2I5 (CCI). In this work, hydrophobic solvents were investigated as polishing media for water-sensitive CCI single crystals. Three hydrophobic solvents—squalane, silicone oil, and mineral oil— were used as dispersion media for 1 μm alumina abrasives, followed by toluene rinsing after polishing. Among them, squalane showed the best polishing performance, yielding the lowest surface roughness (Rq=17.29 nm), the highest transmittance of 78.21%, and the narrowest rocking-curve FWHM of 0.025°. In addition, sequential polishing in squalane using P2000 sandpaper, P4000 sandpaper, and 1 μm alumina enhanced the light yield and improved the energy resolution from 6.53% to 5.83%. These results identify squalane as a promising polishing medium for water-sensitive halide perovskite scintillators.

Acknowledgment

This work was supported by the National Research Foundation of Korea (NRF), funded by the Ministry of Science and ICT (RS-2023-NR077190, RS-2022-00165164), and by the National Research Foundation of Korea and the Commercializations Promotion Agency for R&D Outcomes (RS-2023-00234651).

Keywords: Perovskite Scintillator, Cs3Cu2I5, Hydrophobic Polishing, Surface Treatment
15:00 Poster panel: 15

Poster Number:
NSS-01-015

Combining cross-luminescent scintillators and μSiPMs for better timing in ToF-PET (#1249)

K. Herweg1, 2, S. Bisi3, C. Bruschini3, E. Charbon3, A. Gola4, L. Parellada-Monreal4, M. Penna4, D. Schug1, 2, V. Schulz2, S. Gundacker5

1 RWTH Aachen University, University Hospital RWTH Aachen, Aachen, Germany
2 RWTH Aachen University, Institute of Imaging and Computer Vision, Aachen, Germany
3 Ecole polythechnique fédérale de Lausanne, Advanced Quantum Architecture Laboratory, Neuchatel, Switzerland
4 Fondazione Bruno Kessler, Trento, Italy
5 Austrian Academy of Sciences, Marietta Blau Institute for Particle Physics, Vienna, Austria

Abstract

Time-of-flight positron emission tomography (ToF-PET) has boosted PET image quality significantly in the last years. During its first inception it was built with cross-luminescent BaF2 crystals, which have since been replaced by LYSO. Recently, cross-luminescence has regained popularity with new scintillators being developed. However, BaF2 and the recently developed Cs2ZnCl4 could not improve on the LYSO state-of-the-art coincidence time resolution (CTR) (56 ps for 2x2x3 mm³ and 95 ps for 3x3x19 mm³). As Cs2ZnCl4 shows a significant Cherenkov production, we combined it with the DIGILOG approach to boost its timing performance. The DIGILOG approach segments the sensor into μSiPMs and has shown an improved timing performance for BGO due to its Cherenkov radiation and an improved SPTR. Here, we simulated a 3x3x3 mm³ and a 3x3x20 mm³ Cs2ZnCl4 crystal coupled to seven different μSiPM arrays. The simulation included noise factors like dark counts, cross-talk, SPAD dead time and analog noise. It was designed with a PDE of 60 % and an SPTR of 25 ps. This resulted in an improved CTR of 34+/-4 ps for an array of 20x20 μSiPMs coupled to a 3x3x3 mm³ Cs2ZnCl4 crystal compared to the non-segmented SiPM at 48+/-3 ps. Furthermore, for the 3x3x20 mm³ crystal, a CTR of 64+/-4 ps was reached with a 10x10 μSiPM array, while the non-segmented SiPM showed a CTR of 84+/-3 ps. The results of the segmented SiPMs improve on the LYSO state-of-the-art. Additionally, they demonstrate that the DIGILOG SiPM approach improves timing performance not just for BGO, but also for other scintillators with high Cherenkov yield, ultra-fast emission and low light yield. We also provide motivation to optimize sensors for Cs2ZnCl4, which could enable better timing performance than the LYSO state-of-the-art.

AcknowledgmentThis research is funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) - 500540345 and the Swiss National Science Foundation (SNSF) - #200021L_208073.
References
[1] Wong, W. H. et al. 1984, 'Characteristics of small barium fluoride (BaF2) scintillator for high intrinsic resolution time-of-flight positron emission tomography', IEEE TNS
[2] Herweg, K. et al. 2023, 'On the Prospects of BaF2 as a Fast Scintillator for Time-of-Flight Positron Emission Tomography Systems', IEEE TRPMS
[3] Rutstrom, D. et al. 2022, 'Improved light yield and growth of large-volume ultrafast single crystal scintillators Cs2ZnCl4 and Cs3ZnCl5', Optical Materials
[4] Herweg, K. et al. 2024, 'Timing limits of ultrafast cross-luminescence emission in CsZnCl-based crystals for TOF-CT and TOF-PET', EJNMMI Physics
[5] Nadig, V. et al. 2023, 'Timing advances of commercial divalent-ion co- doped LYSO:Ce and SiPMs in sub-100 ps time-of-flight positron emission tomography', PMB
[6] Gundacker, S. et al. 2023, 'DIGILOG: A digital-analog SiPM towards 10 ps prompt-photon tagging in TOF-PET', 2023 IEEE NSS MIC RTSD
[7] Herweg, K. et al. 2024, 'Investigating μSiPMs to overcome the limits of BGO in ToF-PET', 2024 IEEE NSS MIC RTSD
[8] Herweg, K. et al. 2026, 'Exploring μSiPMs with BGO for Cherenkov time-of-flight in PET', revision submitted to IEEE TRPMS
[9] Zuo, X. et al. 2025, 'Scintillation performance of 1-inch-diameter Cs2ZnCl4 crystals', CrystEngComm
Keywords: ToF-PET, sensor segmentation, Cherenkov, CsZnCl, cross-luminescence
15:00 Poster panel: 17

Poster Number:
NSS-01-017

Temperature Dependence of Pulse Shape Discrimination in SiPM-Based EJ-276D Detectors (#1585)

J. W. Fritchie1, A. Di Fulvio1, G. Gariazzo1, G. Roche1

1 University of Illinois Urbana-Champaign, Nuclear, Plasma, and Radiological Engineering, Urbana, Illinois, United States of America

Abstract

The temperature dependence of pulse shape discrimination performance was investigated for three commercial silicon photomultiplier technologies coupled to an EJ-276D organic scintillator. Measurements were conducted at 22 °C, 30 °C, 40 °C, and 50 °C using PuBe sources. Pulse shape discrimination was quantified using the tail-to-total ratio and figure of merit. For all devices, the figure of merit increased at 30 °C. The Broadcom device exhibited the highest performance, increasing from 1.12 at 22 °C to a maximum of 1.17 at 30 °C before decreasing to 0.76 at 50 °C. The Onsemi and Hamamatsu devices showed smaller improvements, with figure of merit values increasing from 0.86 to 0.89 and 0.84 to 0.90, respectively, between 22 °C and 30 °C. At 50 °C, all devices exhibited reduced performance due to increased silicon photomultiplier thermal noise. Temperature-dependent changes in pulse shape were observed, with increasing temperature producing faster decay and modifying the balance of prompt and delayed scintillation light, improving neutron-gamma separation at intermediate temperatures. Despite degradation at higher temperature, all devices maintained effective discrimination up to 50 °C. These results demonstrate that silicon photomultiplier-based detectors are capable of robust neutron-gamma discrimination at elevated temperatures relevant to safeguards applications.

AcknowledgmentThis work is funded in-part by Sandia National Laboratories (SNL) LDRD Award 2308289. SNL is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration (NNSA) under contract DE-NA0003525. This research was performed under appointment to the Nuclear Nonproliferation International Safeguards Fellowship Program sponsored by the U.S. NNSA's Office of International Nuclear Safeguards.
References
[1] Acerbi, Fabio, Gundacker, Stefan 2019, 'Understanding and Simulating SiPMs', Nulcear Insturments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 926, 16-35
[2] Borgwardt, TC, Oukrop, L, Bartlett, KD, Smith, K, Williamson, E, Meierbachtol, KC, Febbraro, M 2025, ‘Temperature dependence of the nspec fieldable neutron spectrometer’, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1072, article 170161.
[3] Arrue, J, Chandler, C, Duce, M, Lim, A, Sellinger, A, Erickson, A 2023, ‘Impact of temperature on light yield and pulse shape discrimination of polysiloxane-based organic scintillators formulated with commercial resins’, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1056, article 168650.
Keywords: Silicon photomultipliers, pulse shape discrimination, radiation detection, organic scintillators, temperature dependence
15:00 Poster panel: 19

Poster Number:
NSS-01-019

Scintillation light quenching for energetic charged particles in GAGG:Ce (#1607)

F. Liang1, N. Floyd1, H. Jayatissa1, P. Adsley2, A. Alvarez2, R. Bartsch2, S. Fritz2, T. Hankins2, B. Harvey2, K. Pham2, E. Schnorrenberg2, D. Shelden2, S. Yennello2

1 Los Alamos National Laboratory, ISR Division, Los Alamos, New Mexico, United States of America
2 Texas A&M University, Cyclotron Institute, College Station, Texas, United States of America

Abstract

Cerium-doped gadolinium gallium aluminium garnet (GAGG:Ce) is a novel scintillator with excellent scintillation properties. It is suitable for use in various basic science research and applications. Because the scintillation light is quenched for charged particle detection, it is necessary to use beams from accelerators to calibrate the energy response. Measurements of energetic charged particles incident on three GAGG:Ce crystals were performed using accelerated protons, 4He, and 12C at 0oC and 20oC in consideration for detecting charged particles in the earth's radiation belts for space weather modeling and for deploying in dosimetry devices in ion therapy, respectively. The Birks factor which quantitatively describes the extent of quenching was deduced from the experimental data. For all three GAGG:Ce scintillators, the Birks factor decreases with the atomic number Z of the incident ions. Furthermore, less light quenching, a smaller Birks factor, was observed for GAGG:Ce at 0oC. The quenching for the Mg-codoped GAGG:Ce which has a shorter decay time constant, was found to be less temperature dependent compared to the other two GAGG:Ce crystals.

AcknowledgmentLos Alamos National Laboratory is managed by Triad National Security, LLC for the U.S. Department of Energy's NNSA.
References
[1] Wang, YQ, Burward-Hoy, JM, Tesmer, JR 2014, 'Production of high energy and low flux protons using 2D(3He,p)4He for space detector calibrations', Nucl. Instrum. Methods, vol. B332, pp. 432-438.
[2] Espinoza, TN, et al. 2024, 'Proton quenching in rare-earth inorganic scintillators: GAGG:Ce and YSO:Ce', IEEE Trans. Nucl. Sci., vol. 71, pp. 2102-2108.
[3] Birks, JB 1964, 'The theory and practice of scintillation counting', Pergamon Press, Oxford.
[4] Treytak, VI 2010, 'Semi-empirical calculation of quenching factors for ions in scintillators', Astro. Phys., vol. 33, pp. 40-53.
[5] Ziegler, JF, Biersack, JP, Littmark, U 1985, 'The stopping and range of ions in solids', vol. 1, Pergamon Press, New York.
[6] Berger, MJ, Coursey, JS, Zucker, MA, Chang, J 2017, 'Stopping-power & range tables for electrons, protons and helium ions', https://dx.doi.org/10.18434/T4NC7P.
Keywords: Cerium-doped gadolinium gallium aluminium garnet, scintillation quenching, Birks factor, accelerated ion beam
15:00 Poster panel: 21

Poster Number:
NSS-01-021

Facile, scalable and high-yield synthesis of zero-dimensional copper halide Cs3Cu2Cl5 scintillator with near-unity quantum yield for high-resolution X-ray imaging applications (#1659)

Y.S. Choi1, J. Im2, K. Heo3, S.O. Cho2, B.K. Cha4, B. Shin1

1 KAIST, Materials Science and Engineering, Daejeon, Republic of Korea
2 KAIST, Nuclear and Quantum Engineering, Daejeon, Republic of Korea
3 Viewworks, Anyang, Republic of Korea
4 KERI, Ansan, Republic of Korea

Abstract

Metal halide perovskites, particularly copper halide variants, have emerged as promising scintillators owing to their large Stokes shift, high photoluminescence quantum yield (PLQY), and efficient radioluminescence. Here, we demonstrate a dioxolane-mediated reaction synthesis as a simple, scalable, and high-yield strategy for producing Cs3Cu2Cl5 powders with near-complete conversion. By employing low-polarity yet water-miscible dioxolane as the reaction medium together with an aqueous H3PO2 additive, the solubility imbalance between the precursors inherent to low-polarity solvents is effectively addressed. This approach enables stoichiometry-controlled dissolution–precipitation under a low-polarity reaction environment and the formation of phase-pure Cs3Cu2Cl5 powders with near-unity PLQY. The powders show bright green emission at ~530 nm and retain over 80% of their initial efficiency after 300 days of ambient storage without encapsulation, demonstrating remarkable intrinsic stability. Cs3Cu2Cl5-based composite films deliver an ultrahigh light yield of ~98,000 photons MeV-1, greatly surpassing that of commercial scintillators such as Gd2O2S and CsI:Tl, and exhibiting excellent dose linearity and long-term irradiation stability. When integrated into commercial flat-panel detectors, the Cs3Cu2Cl5-based composite films successfully enabled high-quality 2D radiographic and 3D computed tomography imaging, directly verifying their compatibility with existing X-ray detection systems. This facile and efficient synthesis, together with the demonstrated device-level imaging performance, highlights Cs3Cu2Cl5 as a scalable and practical candidate for next-generation X-ray scintillators.

Keywords: halide perovskite, scintillator, Cs3CuCl5
15:00 Poster panel: 23

Poster Number:
NSS-01-023

Spectral-feature-based radionuclide and radiation-type discrimination using a plastic scintillation fiber detector for in-situ pipe measurements (#1767)

T. Abe1, T. Nakasone2, T. Yamada2, M. Kanno3, Y. Morishita1

1 Japan Atomic Energy Agency, Collaborative Laboratories for Advanced Decommissioning Science, Minamisomashi, Japan
2 Japan Radiation Engineering Co.,Ltd., Hitachishi, Japan
3 PESCO Co., Ltd., Minatoku, Japan

Abstract

A capillary-type plastic scintillation fiber (PSF) detector combined with a multi-channel analyzer (MCA) was investigated for radionuclide and radiation-type discrimination in in-situ pipe measurements. Plastic scintillators generally exhibit poor energy resolution, resulting in broadened spectra that complicate conventional peak-based identification. In this study, spectral features including the Compton edge (CE), endpoint, and centroid were extracted from β- and γ-ray spectra obtained using Sr-90/Y-90 and Cs-137 sources. The positional dependence of these features along the fiber was evaluated, and significantly reduced variation compared with previous studies was achieved by introducing a reflective structure at the fiber end. In addition, radiation-type discrimination under mixed β/γ conditions was investigated using a stainless-steel (SUS) cover to suppress β-ray components. The results demonstrated that the extracted spectral features remained stable against source position and that condition switching using the SUS cover enabled practical discrimination of β and γ components. These findings indicate that the proposed method is applicable to contamination assessment in confined environments such as piping systems.

References
[1] S. Song, J. H. Park, J. Kim, S. Kim, S. Jegal, S. Lee, and B. Lee, “Acquiring gamma-ray energy spectrum using a plastic scintillation optical fiber detector,” Photonics, vol. 11, p. 493, 2024.
[2] J. W. Bae and H. R. Kim, “Plastic scintillator beta ray scanner for in-situ discrimination of beta ray and gamma ray radioactivity in soil,” Nucl. Eng. Technol., vol. 52, pp. 1259–1265, 2020.
Keywords: Plastic scintillation fiber, Spectral analysis, Compton edge, Radionuclide discrimination
15:00 Poster panel: 25

Poster Number:
NSS-01-025

Investigation of Coincidence Time Resolution in BaF2:Y Scintillators for TOF PET Applications (#1798)

H. Kim1, J. Chen3, J. Zhang3, J. Xu3, S. Sundramoorthy2, Y. Wang1, C.-T. Chen1, C.-M. Kao1

1 University of Chicago, Department of Radiology, Chicago, Illinois, United States of America
2 University of Chicago, Department of Radiation and Cellular Oncology, Chicago, Illinois, United States of America
3 Chinese Academy of Sciences, Shanghai Institute of Ceramics, Shanghai, China

Abstract

We are investigating BaF₂:Y scintillators for TOF‑PET applications. BaF₂ exhibits an ultra‑fast scintillation component with a 0.6 ns decay time produced through cross‑luminescence, making it an attractive material for achieving coincidence time resolutions below 100 ps. Recent advances in Vacuum‑Ultraviolet (VUV) SiPMs, which provide high photon‑detection efficiency in the deep‑UV range, have made it increasingly feasible to reliably detect this fast component. In addition to the fast emission, BaF₂ also contains a slow scintillation component with a decay time of approximately 600 ns. This slow component can be substantially suppressed through doping—for example, BaF₂:Y, produced via yttrium doping. Effective suppression of the slow component is essential for applications requiring high count‑rate capability, excellent timing performance, and minimal pulse pile‑up, such as TOF‑PET. In this work, we investigated the coincidence time resolution (CTR) of BaF₂:Y scintillators. The BaF₂ and BaF₂:Y crystals used in this study were grown and polished by the Shanghai Institute of Ceramics (SIC), China. For the BaF₂:Y samples, the yttrium concentration was set to 2 at%, which suppressed the slow component by approximately a factor of four while leaving the fast‑component light yield unaffected. Hamamatsu S13370 VUV‑MPPCs were used to detect the fast scintillation component. Pairs of BaF₂ and BaF₂:Y crystals with dimensions 2 × 2 × 3 mm³ were optically coupled to S13370 VUV‑MPPCs and irradiated with a ²²Na source placed between them in a coincidence setup. We measured CTR values of 86 ps for BaF₂ and 96 ps for BaF₂:Y. These initial results are highly promising, and we anticipate further improvements in CTR with a more optimized experimental setup. Here, we report our preliminary findings.

Keywords: BaF2:Y, Coincidence Time Resolution, TOF PET, VUV SiPM
15:00 Poster panel: 27

Poster Number:
NSS-01-027

Experimental Study of DOI Effects on the Timing Response of a 1”×2” LaBr3 Detector (#1996)

S. Gaitan Dominguez1, V. M. Nouvilas1, M. Caballero Rodríguez1, J. A. Briz1, L. M. Fraile2, J. Udias1

1 Complutense University of Madrid, Group of Nuclear Physics, EMFTEL and IPARCOS, Madrid, United Kingdom
2 Cern, ISOLDE, EP Department, Geneva, Genève, United Kingdom

Abstract

Depth of interaction (DOI) effects can affect the timing response of scintillation detectors due to variations in optical photon transport inside the crystal volume. In this work, DOI-dependent timing measurements were performed using a 1”×2” LaBr3​ scintillation detector coupled to a photomultiplier tube (PMT) within the framework of the HiSTARs project. A 22Na source was positioned at different locations along the crystal axis in coincidence with a fast SiPM-based reference detector, and signals were acquired using a DRS digitizer operating at 5 GS/s. The present study focuses on the comparison between interactions occurring close to the PMT side of the crystal and interactions occurring close to the opposite side. Coincidence timing distributions show a systematic shift of approximately 300 ps in the centroid position between both irradiation configurations. Coincidence timing resolutions of 287 ps and 268 ps FWHM were obtained for the two positions, respectively. The observed behavior is consistent with differences in optical photon propagation paths and light collection timing inside the scintillator. Although DOI effects introduce measurable timing shifts, the overall degradation of the timing resolution remains moderate for the studied configurations. Additional irradiation geometries and analysis conditions are currently under study in order to obtain a more complete characterization of DOI effects in long LaBr3​ scintillation detectors.

AcknowledgmentThis work was supported by the Spanish Government under grant PR38/23-HISTARS(MRR)
References
[1] Luxium Solutions, “LaBr3 Scintillation Crystals.” [Online]. Available: https://www.luxiumsolutions.com
[2] Hamamatsu Photonics, “Photomultiplier Tubes: Basics and Applications,” Hamamatsu, Japan. [Online]. Available: https://www.hamamatsu.com 
[3] EPIC Crystal Company, “Scintillation Crystals.” [Online]. Available: http://www.epic-crystal.com
[4] S. Ritt, “DRS4 Handbook,” Paul Scherrer Inst., Villigen, Switzerland, Rev. 0.9, 2008
Keywords: Depth of interaction, LaBr​3, scintillation detectors, silicon photomultipliers, timing resolution
15:00 Poster panel: 29

Poster Number:
NSS-01-029

Development of Mo-Doped Cs2HfCl6 for Dosimetry in High Dose-Rate Environment (#2267)

S. Kondo1, C. F. Fujiwara2, 3, A. Yamaji3, S. Kurosawa3, 4

1 Nagoya University, School of Engineering, Nagoya, Japan
2 Tohoku University, Department of Materials Science, Graduate School of Engineering,, Sendai, Japan
3 Nagoya University, Graduate School of Engineering, Nagoya, Japan
4 Osaka University, Institute of Laser Engineering, Osaka, Japan

Abstract

In order to accomplish rapid and safe decommissioning of Fukushima Daiichi nuclear power plant, the remote and real-time dosimeter was required. To address this issue, detector systems comprising a scintillator coupled to an optical fiber have been proposed.  In this system, emission wavelength of the scintillator itself should be in the near-infrared (NIR) band, to spectrally discriminate the scintillation signal from the Cherenkov component generated within the optical fiber itself. Therefore, in this study, we focus on Mo doped Cs2HfCl6 as the scintillator with NIR emission wavelength and high atmospheric stability. The Mo doped Cs2HfCl6 scintillators were grown via melt solidification method.  The result of powder X-ray diffraction pattern suggested that the single phase of Mo: Cs2HfCl6 were successfully obtained. Furthermore, the emission wavelength of Mo doped Cs2HfCl6 was shifted to 900nm from 420 nm of host emission of C2HfCl6. These results indicate Mo: CHC is the promising scintillator for the real time remote monitoring system with optical fiber.

Keywords: Scintillator material, Dosimetry, Gamma-ray detection, Optical fiber, Near-infrared emission
15:00 Poster panel: 31

Poster Number:
NSS-01-031

From LaBr3:Ce to Cs2LiLa(Br,Cl)6:Ce Mixed-Halide Elpasolites: Tailoring Scintillation Response for High-Precision Gamma-Ray and Neutron Detection (#2321)

Z. Cai1, Z. Yin1, X. Zhang1, Z. Kang2, J. Liu2, Q. Zhao1, T. Wang1

1 Northwestern Polytechnical University, State Key Laboratory of Solidification Processing, Xi'an, China
2 Crystalab Corporation Ltd, Xi'an, China

Abstract

Halide scintillators provide a flexible material platform for detectors requiring high gamma-ray energy resolution, fast response, and, in lithium-containing compounds, intrinsic neutron sensitivity. This work presents CrystaLab Co., Ltd.'s compositional-engineering route from LaBr3:Ce gamma-ray scintillators to Cs2LiLa(Br,Cl)6:Ce (CLLBC) mixed-halide Elpasolites for combined gamma-ray and neutron detection. Packaged LaBr3:Ce detector modules demonstrate high-resolution gamma-ray spectroscopy, with a representative energy resolution of 2.37% at 662 keV and product specifications below 3% at 662 keV. CeBr3 detectors provide a low-background lanthanide-halide option with energy resolution below 4.5% at 662 keV. By introducing Li and tuning the Br/Cl halide sublattice, Cs2LiLaBr6 (CLLB) and CLLBC extend the platform to neutron-sensitive dual-mode detection with neutron-gamma pulse-shape discrimination (PSD). CLLB products provide gamma-ray energy resolution below 4.5% at 662 keV and room-temperature neutron-gamma figure of merit (FOM) values >1.2, while optimized 1-inch CLLBC crystals achieved 3.09% energy resolution at 662 keV and FOM = 2.1. These results show how halide composition, crystal growth, and detector integration can tailor scintillation response from high-precision gamma-ray spectroscopy toward compact mixed-field radiation detectors.

Keywords: LaBr3:Ce, CLLB, CLLBC, gamma-ray spectroscopy, neutron-gamma discrimination
15:00 Poster panel: 33

Poster Number:
NSS-01-033

Application of neutron sensitising layers to plastic scintillator (#2414)

J. R. Hitchens1, C. Allwork1, S. L. Chauhan1, T. Crane1, T. Heather1, M. P. Taggart1

1 AWE Nuclear Security Technologies, Reading, United Kingdom

Abstract

Eljen plastic scintillator disks have been coated with layers of neutron sensitiser in a systematic study on the thickness of neutron detection layers. Here we discuss the impact of enhancing standard plastic scintillator (PVT) with coatings containing both lithium and boron isotopes. The application of these layers enhances the material to provide a mechanism for detecting neutron radiation. A systematic study was performed to assess the impact of sensitiser thickness on neutron detection efficiency and neutron-gamma pulse shape discrimination (PSD) performance. Samples were exposed to the mixed radiation fields of a 252Cf source, and a sample of plutonium. The results demonstrate clear neutron-gamma discrimination in sensitised samples, with measured figures of merit in excess of 3 recorded for optimised lithium-rich coatings. This is comparable performance to established dual-mode detectors. These findings show that thin, externally applied neutron-sensitising layers provide an effective route to enhancing the performance of conventional plastic scintillators. This approach may offer a low-cost means of upgrading existing detector systems in nuclear security applications.

References
[1] J. Glodo, et al., “Selected Properties of Cs2LiYCl6:Ce3+ Scintillator,” IEEE Trans. Nucl. Sci., vol. 56, pp. 873–880, 2009.
[2] R. Song, et al., “The Neutron-Gamma Pulse Shape Discrimination of CLLB Detector,” EPJ Web of Conferences, vol. 295, Art. No. 09031, 2024
[3] N. Zaitseva, et al., “Plastic scintillators with efficient neutron-gamma pulse shape discrimination,” Nuclear Instruments and Methods in Physics Research A, vol. 668, pp. 88-93, 2012
[4] R. Breuckers, C. Bartle and A. Edgar, "Transparent lithium loaded plastic scintillators for thermal neutron detection," Nuclear Instruments and Methods in Physics Research A, vol. 701, pp. 58-61, 2013
[5] I. Pawelczak, et al., “Boron-loaded plastic scintillators with neutron-γ discrimination capability,” Nuclear Instruments and Methods in Physics Research A, vol. 751, pp. 62-69, 2014
[6] N. Cherepy, et al., “Bismuth- and lithium-loaded plastic scintillators for gamma and neutron detection,” Nuclear Instruments and Methods in Physics Research A, vol. 778, pp. 126-132, 2015
Keywords: Boron coated plastic scintillator, Lithium coated plastic scintillator, Neutron detection, Nuclear security, Pulse shape discrimination
15:00 Poster panel: 35

Poster Number:
NSS-01-035

Micropower Generation and Radiation Detection with Cr-doped Al2O3 Transparent Ceramics (#2416)

N. Kawaguchi1, K. Miyajima1, K. Okazaki1, T. Kato1, D. Nakauchi1, T. Yanagida1

1 Nara Institute of Science and Technology, Ikoma, Japan

Abstract

We prepared 0.05–1% Cr-doped Al2O3 transparent ceramics with a diameter of approximately 10 mm by spark plasma sintering. The samples showed sharp emission peaks at around 700 nm, which matched the sensitivity of typical Si-photodetectors. When the samples were combined with a Si-photodetector and irradiated with X-, α-, and β-rays, currents ranging from picoamperes to nanoamperes were detected. The generated power was maximized when the dopant concentration was around 0.2–0.4 %.

Acknowledgment

This work was supported by the Cooperative Research Project of Research Center for Biomedical Engineering, Kazuchika Okura Memorial Foundation, Yashima Environment Technology Foundation, Iketani Science and Technology Foundation, and JSPS KAKENHI (22H00309, 24K03197, and 26K03208).

Keywords: transparent ceramics, scintillation detector, micropower generation
15:00 Poster panel: 37

Poster Number:
NSS-01-037

Single-ended Multiplexed Readout Scintillation Detector With Depth of Interaction Capability: Architecture and Optical Simulation (#2505)

G. Jazvac1, A. M. Kožuljević1, L. Lotina1, L. Pavelić1, 2

1 Institute for Medical Research and Occupational Health, Division of Radiation Protection, Zagreb, Croatia
2 Nucleometrix d.o.o., Zagreb, Croatia

Abstract

An accurate and precise determination of the depth of interaction (DOI) of incident photons in scintillation detectors is paramount to increasing the spatial resolution of positron annihilation tomography (PET) systems. The high number of readout channels is a major source of cost and complexity of such systems, while light sharing multiplexed readouts suffer from edge effects. We have developed a pixelized scintillator detector with DOI capability and 4-to-1 multiplexing utilizing only single-ended readout and light-sharing light guides which can improve signal-to-noise ratio and mitigate edge effects present in other solutions. The scintillator matrix is coupled to a silicon photomultiplier (SiPM) array on one end and light guides on the other. Adjacent crystals are connected in pairs via light guides to enable light sharing. The scintillation light of these crystal pairs is shared between exactly two SiPM pixels. DOI is determined using the ratio of signals on the two SiPM pixels. Pairing distant crystals on matrix edges avoids edge effects. We present the detector architecture and the results of optical simulations evaluating its DOI capability. The interaction position was swept along the central axis of one crystal and the number of incident photons was recorded in the interaction crystal and in the optically connected crystal. The number of rays incident on the sensor coupled to the interaction crystal is always higher than that of the connected crystal. This enables unambiguous determination of the interaction crystal. The ratio of the number of rays incident on the sensors spans three orders of magnitude and approaches unity as the source gets closer to the light guide. These properties demonstrate a favorable DOI capability of the presented detector configuration.

AcknowledgmentThis work was funded by the European Union – Next Generation EU and is part of the project Voxel matrix detector for full solid angle radiological imaging (VMDScan) - NPOO.C3.2.R2-I1.06.0084.
References
[1] LaBella, A, Cao, X, Zeng, X, Zhao, W, Goldan AH 2021, ‘Sub-2 mm depth of interaction localization in PET detectors with prismatoid light guide arrays and single-ended readout using convolutional neural networks’, Med. Phys., 48, 1019-1025, AAPM
[2] Yu, X, Han, S, Liang, C, Liu, H, Zhang, X, Tao, J, Zhao, H, Xu, J, Peng, Q 2025, ‘An optimized DOI decoding method for a PET detector with nine-crystal-to-one-photodetector coupling’, Phys. Med. Biol., 70, 175016, IPEM
Keywords: depth of interaction, positron emission tomography, solid scintillation detectors
15:00 Poster panel: 39

Poster Number:
NSS-01-039

Performance evaluation of GaGG(Ce) scintillators with different photosensors (#2850)

M. Caballero Rodríguez1, N. Bernier1, V. M. Nouvilas1, L. Fraile2, 1, O. Alonso-Sañudo1, J. A. Briz1, S. Gaitan1, G. G. de Lorenzo1, P. Gonzalez-Tarrio1, A. Illana3, J. Udias1

1 Universidad Complutense de Madrid, Facultad de Ciencias Físicas / Departamento de Estructura de la Materia, Física Térmica y Electrónica, Madrid, Spain
2 CERN, ISOLDE, EP Department, Geneva, Spain
3 CSIC, Instituto de Estructura de la Materia, Madrid, Spain

Abstract

The HIE-ISOLDE Timing Array for Reaction Studies (HISTARS) project at CERN is developing a specialized detector system designed to measure the lifetimes of excited nuclear states. For efficient particle detection, thin square GaGG(Ce) are utilized alongside YSO due to their high density and fast scintillation properties. This work evaluates the performance of GAGG(Ce) crystals coupled with two distinct photosensors: a Hamamatsu R9779 photomultiplier tube (PMT) and an array of four silicon photomultipliers (SiPM) using a custom-designed circuit. These configurations were tested in combination with a LaBr3(Ce) detector to facilitate coincidence measurements. Data acquisition was performed using high-speed digitizer to extract timing and energy information. This article reports on the comparative performance of both readout methods, specifically characterizing pulse shape discrimination capabilities, energy resolution, and the coincidence time resolution for alpha-gamma events. Although the energy resolution is acceptable and it has a good pulse shape discrimination capability, the measured timing limitations show that the current configuration is not ideal for the HISTARS array. These results will guide the selection of better-suited materials for high-precision timing at HIE-ISOLDE.

AcknowledgmentThis work has been supported by the Spanish Ministerio de Ciencia e Innovaci\'on under projects PID2019-104714GB-C21 and PID2022-140400NB-C21.
References
[1] Wang, Z, Guo, H, Qian, S 2020, ‘Pulse shape discrimination of GAGG:Ce crystals for charged particle detection’, Journal of Instrumentation, Vol. 15, p. C06031, Bristol: IOP Publishing.
[2] Tsuchida, N, Ikeda, M, Kamae, T 1997, ‘A study of the GAGG:Ce crystal for its application in nuclear physics’, Nuclear Instruments and Methods in Physics Research Section A, Vol. 385, pp. 290–298, Amsterdam: Elsevier.
[3] Vedia, V, Carmona-Gallardo, M, Fraile, LM 2017, ‘Characterization of specialized LaBr3(Ce) detectors for fast-timing lifetime measurements’, Nuclear Instruments and Methods in Physics Research Section A, Vol. 857, pp. 98–105, Amsterdam: Elsevier
Keywords: GAGG(Ce) scintillator, pulse shape discrimination, photomultiplier tube, silicon photomultipliers, timing resolution
15:00 Poster panel: 41

Poster Number:
NSS-01-041

Cosmic-Ray Muon Position Reconstruction via Dual-End Readout of Triangular Plastic Scintillators (#2888)

Z. Yin1, 2, Y. Zhang1, 4, J. Zhang5, L. Wang1, 2, Y. Huang1, 2, X. Zhao1, 2, J. Cheng1, 3, Y. Liu1, 3

1 Beijing Normal University, School of Physics and Astronomy, Beijing, China
2 Beijing Normal University, Joint Laboratory of Jinping Ultra-low Radiation Background Measurement of Ministry of Ecology and Environment, Beijing, China
3 Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province, Liangshan, China
4 Beijing Normal University, Key Laboratory of Beam Technology of Ministry of Education, Beijing, China
5 Chengdu University of Technology, College of Nuclear Technology and Automation Engineering, Chengdu, China

Abstract

By measuring the time difference and amplitude ratio of the signals at both longitudinal ends of a triangular prism plastic scintillator through dual-end readout, it is theoretically possible to reconstruct the longitudinal position of an incident muon. This paper presents a cosmic-ray muon collimation device that determines the incident region via triple coincidence and features an adjustable incident area. Using natural cosmic-ray muons obtained with this device, dual-end positioning experiments were carried out on a triangular prism plastic scintillator. The threshold-crossing time and amplitude information were extracted from the complete waveforms and fitted, yielding well-fitted relationship functions of the threshold-crossing time difference and the logarithm of the amplitude ratio with respect to the hit position. Experimental results show that the longitudinal position resolution achieved by this method is 3 cm, confirming the effectiveness of the dual-end readout positioning method in triangular prism plastic scintillator array muon detectors and laying a foundation for future research on lightweight and efficient plastic scintillator array detectors.

AcknowledgmentThis work was supported by the National Natural Science Foundation of China (No.12222502).
References
[1] Nagamine, K, Iwasaki, M, Shimomura, K et al. 1995, ‘Method of probing inner-structure of geophysical substance with the horizontal cosmic-ray muons and possible application to volcanic eruption prediction’, Nucl. Instrum. Methods Phys. Res. A, vol. 356, no. 2-3, pp. 585-595, Amsterdam: Elsevier.
[2] Park, C, Kim, K B, Baek, M K et al. 2023, ‘Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system’, Nuclear Engineering and Technology, vol. 55, no. 3, pp. 1009-1014, Amsterdam: Elsevier.
[3] Wang, Z, Li, Z, Fan, X et al. 2025, ‘Composition, structure and position resolution optimization of plastic scintillator units and arrays for a muon tomography detector’, Radiat. Phys. Chem., vol. 236, Art. no. 112893, Amsterdam: Elsevier.
[4] Sweany, M, Galindo-Tellez, A, Brown, J et al. 2019, ‘Interaction position, time, and energy resolution in organic scintillator bars with dual-ended readout’, Nucl. Instrum. Methods Phys. Res. A, vol. 927, pp. 451-462, Amsterdam: Elsevier.
Keywords: muon collimator, dual-end readout, time difference, logarithm of amplitude ratio
15:00 Poster panel: 43

Poster Number:
NSS-01-043

Scintillation Properties of 6Li-doped CsI:Tl Crystals for Thermal Neutron Detection (#2928)

D. Sharma1, 2, A. K. Gourishetty1, M. Tyagi2, M. Sonawane2

1 India Institute of Technology Roorkee, Department of Physics, Roorkee, India
2 Bhabha Atomic Research Centre, Technical Physics Division, Mumbai, India

Abstract

Alkali halide scintillators have emerged as promising low-cost alternatives to conventional thermal neutron detectors such as 3He counters, through the incorporation of neutron sensitive isotopes such as 6Li or 10B, owing to their ease of growth and scalability. In this work, single crystals of CsI:Tl incorporating 2% 6Li and varying concentration of Sr as dopants were grown using the Bridgman melt growth method and evaluated for their scintillation and neutron-gamma discrimination characteristics. The radioluminescence spectra are dominated by yellow-green emission from Tl activator sites. Under 137Cs excitation, the light output of the crystals was observed to decrease with Sr incorporation compared to the 6Li-only doped crystal, while the crystal doped with 2% Sr exhibit the best energy resolution of 6.8% at 662keV. The pulse shape discrimination (PSD) studies of the grown crystals demonstrate effective neutron-gamma discrimination, highlighting the potential of these crystals for use in mixed radiation fields and compact radiation system.

References
[1] Yang, KN, Menge, PR & Ouspenski, V 2017, ‘Li co-doped NaI:Tl (NaIL)—A large volume neutron-gamma scintillator with exceptional pulse shape discrimination’, IEEE Transactions on Nuclear Science, vol. 64, p. 2406, New York: IEEE.
[2] Wang, J, Wang, C, Li, H, Shi, J, Wen, X, Shan, C & Wu, Y 2023, ‘Improvement of energy resolution and neutron–gamma discrimination of NaI:Tl, ⁶Li single crystal scintillators by Ca²⁺ and Sr²⁺ co-doping’, IEEE Transactions on Nuclear Science, vol. 70, p. 840, New York: IEEE.
Keywords: CsI:Tl, Thermal neutron detector, Scintillator, Bridgman method
15:00 Poster panel: 45

Poster Number:
NSS-01-045

Development of Plastic Scintillator by Thermal Polymerization for Gamma Spectroscopy (#2945)

T. Kumar1, V. Anand1, A. K. Gourishetty1

1 Indian Institute of Technology Roorkee, Department of Physics, Roorkee, India

Abstract

A series of polyvinyl toluene (PVT)-based scintillators was prepared via thermal polymerization to investigate the effect of the thermal initiator 2,2-Azobisisobutyronitrile (AIBN) on light output. Samples were synthesized both with varying weight percentages (wt%) of AIBN and without AIBN. All samples contained 2% 2,2-diphenyloxazole (PPO) and 0.05% 1,4-bis(5-phenyl-2-oxazolyl) benzene (POPOP), while the concentrations of vinyl toluene and AIBN were varied. The light output of the developed plastic scintillators (PS) was compared to the commercially available PS EJ-267D using the gamma spectrum from a Cs-137 radiation source. The results indicated that samples containing 0.1% AIBN without argon purging, 1% AIBN without purging, and 0% AIBN with argon purging yielded 24.40%, 28.23%, and 40.88% of the light output of EJ-267D, respectively.

AcknowledgmentThe authors would like to acknowledge Prof. Akash Kaithal and Mr. Manish Tiwari from Department of Chemistry, IIT Roorkee for their help in Argon purging.
This work was supported by the Council of Scientific and Industrial Research (CSIR), Human Resource Development Group (CSIR-HRDG), Government of India, under the Extra Mural Research (EMR) Scheme (ID: 35112355 and File No. 09/0143(21791)/2025-EMR-I). G. Anil Kumar would also like to acknowledge the financial support provided by the Anusandhan National Research Foundation (ANRF) under the projects ANR-2415-PHY-TSAH/24-25 and  ANR-2863-PHY-TSAH/25-26.
 
References
[1] Lee, C.H., Son, J., Kim, T.-H., Kim, Y.K. 2017, ‘Characteristics of plastic scintillators fabricated by a polymerization reaction’, Nuclear Engineering and Technology,Volume 49, Issue 3, April 2017, Pages 592-597, South Korea: Korean Nuclear Society
[2] Lastname, GN, Lastname, GN YYYY, ‘Article’, Journal, Edition, Page, Place of publication: publishers
Fitriana, R., Febrianti, Y., Rahmawati, R. & Saputro, A.H. 2025, ‘A Review on Plastic Scintillator Development and Performance for Gamma-Ray Detection’, Nuclear Science and Engineering, vol. 00, pp. 1–29, Taylor & Francis.
Keywords: Plastic scintillator, polyvinyl toluene, thermal polymerization, gamma spectroscopy, light output.
15:00 Poster panel: 47

Poster Number:
NSS-01-047

Comparative Analysis of Scintillators for TOF-DXA Detectors in the Low-Energy X-ray Region (#3149)

J. Nam1, J. Jung1, S.-H. Chun1, S. Kwon1, J.H. Jung1, Y. Choi1

1 Sogang University, Department of Electronic Engineering, Intelligent Signal Processing System (ISPS) Laboratory, Seoul, Republic of Korea

Abstract

TOF-DXA requires simultaneous energy and timing measurement in the low-energy X-ray region (<60 keV).  However, the low X-ray energies result in reduced scintillation light output and small detector signals, making timing measurement challenging. The purpose of this study was to evaluate the performance of different scintillators for energy and timing measurement in low-energy TOF-DXA detectors.

An analog front-end circuit was developed for energy and timing measurement in low-energy TOF-DXA detectors. Detector signals in the energy path were amplified transmitted differentially to reduce common-mode noise and signal degradation. For timing path, a high slew-rate amplifier and comparator were used to generate LVDS preserving the rising-edge integrity of detector pulses. Three 3 × 3 × 3 mm³ scintillators (LYSO, GFAG, and YAP) coupled with a NUV-MT SiPM were evaluated for simultaneous energy and timing measurement. Output pulses were measured using an Am-241 point source to evaluate energy resolution and pulse characteristics. In addition, X-ray spectra were acquired using an X-ray generator operated at 83 kVp and 0.2 mA with a Ce filter to evaluate detector performance in the DXA.

The energy resolutions measured with LYSO, GFAG, and YAP were 25.7%, 24.4%, and 30.9%, respectively. In the timing path, LYSO exhibited the highest slew rate (364.8 MV/s), followed by GFAG (354.9 MV/s) and YAP (220.8 MV/s). LYSO showed the highest peak-to-valley ratios for both the low- and high-energy peaks (3.96 and 1.62, respectively). For the low-energy peak, GFAG and YAP showed PVRs of 3.32 and 2.45, respectively, whereas YAP showed a slightly higher high-energy PVR (1.13) than GFAG (1.02).This overall performance may be attributed to the balanced characteristics of LYSO, which exhibited higher light output than YAP and faster decay time than GFAG.

These results indicated that LYSO was superior to GFAG and YAP for TOF-DXA applications requiring both energy and timing measurement.

References
[1] Pietrobelli, A, Formica, C, Wang, Z, Heymsfield, SB 1996, ‘Dual-energy X-ray absorptiometry body composition model: review of physical concepts’, Am. J. Physiol., vol. 271, pp. E941–E951.
[2] Park, C, et al. 2020, ‘Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry’, Nucl. Eng. Technol., vol. 52, pp. 2346–2352
Keywords: TOF-DXA, scintillator, crystal, low-energy, front-end
15:00 Poster panel: 49

Poster Number:
NSS-01-049

Improved Low‑Energy Threshold Performance of a Vacuum‑Compatible Hybrid Pixel Detector for Soft X‑ray Applications (#1007)

Y. Nakaye1, T. Inoue1, M. Oka1, T. Sakumura1, Y. Sakuma1, S. Mikusu1

1 Rigaku Corporation, Detector Development Grp., Akishima, Japan

Abstract

We report characterization results of a vacuum‑compatible, pre‑production hybrid pixel array X‑ray detector incorporating a silicon sensor and a low‑noise photon‑counting readout ASIC, with emphasis on extending the practical low‑energy discriminator threshold. Calibration pulse measurements combined with refined noise characterization enabled evaluation of discriminator threshold settings down to approximately 450 eV. Considering measured RMS noise levels on the order of 70-80 e-RMS, such threshold operation implies practical detectability of soft X‑ray photons with energies around 500 eV, although uniform full‑field operation at this threshold is not yet expected.

Low‑threshold operation was found to be temporally stable, showing negligible threshold drift and no observable degradation of pixel operability during continuous operation over extended periods. Soft X‑ray beam validation experiments are planned at the SPring‑8 BL17SU beamline. Additional measurements at higher X‑ray energies will be conducted at BL32‑B2 and BL29XU to support fundamental characterization of detector and ASIC behavior.

The present study focuses on system‑level noise correction and threshold optimization using a conventional silicon sensor. Evaluation with alternative sensor technologies, including iLGAD, is foreseen in future work.

References
[1] Grybos, P, Kmon, P, Maj, P & Szczygiel, R 2016, ‘32k Channel Readout IC for Single Photon Counting Pixel Detectors with 75 μm Pitch, Dead Time of 85 ns, 9 e⁻ rms Offset Spread and 2% rms Gain Spread’, IEEE Transactions on Nuclear Science, vol. 63, no. 2, pp. 1155–1161, Piscataway, NJ: IEEE.
Keywords: Hybrid pixel array detector, Low‑energy threshold, Photon counting, Vacuum‑compatible detector, Noise performance
15:00 Poster panel: 51

Poster Number:
NSS-01-051

Repairing Proton Radiation Damage on n-type, Cross-Strip Germanium Detectors (#1121)

S. E. Haight1, J. Roberts1, S. Boggs1, S. Pike1, J. Gerber1, E. Broadbent1, J. Tomsick2, J. Szornel4, A. Shih3, A. Valluvan1, A. Zoglauer2

1 University of California San Diego, Department of Astronomy and Astrophysics, La Jolla, California, United States of America
2 University of California Berkeley, Space Sciences Laboratory, Berkeley, California, United States of America
3 NASA, Goddard Space Flight Center, Greenbelt, Maryland, United States of America
4 Lawrence Berkeley National Laboratory, Berkeley, California, United States of America

Abstract

We performed a high-energy proton irradiation on a cross-strip germanium detector with the goals of measuring the subsequent loss to detector spectral resolution and characterizing the effectiveness of high-temperature annealing in repairing radiation damage. This work aims to address the expected radiation damage to the Compton Spectrometer and Imager (COSI) during two-year primary mission in low-Earth orbit and evaluate methods for maintenance of spectral resolution. COSI's cross-strip germanium detectors are susceptible to damage induced by the space radiation environment. Negatively charged dislocations induced by high-energy protons trap charge carriers as they drift in the applied bias voltage. The result is a degraded hole-collection signal characterized by widened spectral lines and loss to detector spectral resolution. We irradiated a non-flight detector with a fluence of 1.1 • 107 p+/cm2 — COSI's expected exposure over prime mission (95% confidence level). After irradiation, we executed a series of high-temperature anneals aimed at physically repairing the damaged germanium. We track spectral resolution by measuring the full width half maximum (FWHM) of the 662 keV spectral line emitted by the isotope Cesium-137. We repaired widened FWHMs through high-temperature annealing to within 12% of its preradiation value, repairing to 2.97 keV compared to the original 2.67 keV. We track spectral resolution across annealing processes and characterize a timescale for repair. We find the anneal time needed to repair damage from COSI's primary mission within 1% of the spectral broadening from residual damage. We project the repair time required at 90°C to be 54 +/- 10 hours.

AcknowledgmentThis work was supported by the NASA Astrophysics Research and Analysis (APRA) program, grant 80NSSC22K1881. The Compton Spectrometer and Imager is a NASA Explorer project led by the University of California, Berkeley with funding from NASA, United States under contract 80GSFC21C0059.
References
[1] J. Tomsick, S. Boggs, A. Zoglauer, D. Hartmann, M. Ajello, E. Burns, et al., The Compton Spectrometer and Imager, Proc. ICRC2023, vol. 444, 2023, p. 745.
[2] L. S. Darken, R. C. Trammell, T. W. Raudorf, R. H. Pehl, and J. H. Elliott, "Mechanism for fast neutron damage of Ge(HP) detectors," NuclearInstruments and Methods, vol. 171, no. 1, pp. 49–59, 1980.
[3] J. Beechert, H. Lazar, S. E. Boggs, T. J. Brandt, Y.-C. Chang, C.-Y. Chu, H. Gulick, C. Kierans, A. Lowell, N. Pellegrini, J. M. Roberts, T. Siegert, C. Sleator, J. A. Tomsick, and A. Zoglauer, "Calibrations of the Compton Spectrometer and Imager," Nuclear Instruments and Methods in Physics Research A, vol. 1031, p. 166510, May 2022.
[4] S. E. Haight, S. E. Boggs, G. Brewster, S. N. Pike, J. M. Roberts, A. Y.Shih, J. M. Szornel, J. A. Tomsick, A. B. Valluvan, and A. Zoglauer, "Proton radiation damage and annealing of COSI p-type cross-strip hpge detectors," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.1077, p. 170538, 2025.
[5] J. Ripa, G. Dilillo, R. Campana, and G. Galgoczi, "A comparison of trapped particle models in low earth orbit," in Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray, Eds. SPIE, Dec. 2020.
[6] M. Koenen, J. Bruckner, M. Korfer, I. Taylor, and H. Wankel, "Radiation damage in large-volume n- and p-type high-purity germanium detectors irradiated by 1.5 GeV protons," in Proceedings of 1994 IEEE Nuclear Science Symposium - NSS’94 vol. 1, 1994, pp. 201–205 vol.1.
Keywords: gamma-ray detector, anneal, radiation damage
15:00 Poster panel: 53

Poster Number:
NSS-01-053

Development and Testing of the Strip Pairing Algorithm for the COSI Data Pipeline (#1263)

J. Gerber1, A. Zoglauer2, S. E. Boggs1, F. Hagemann2, C. Kierans3, S. N. Pike1, J. M. Roberts1, F. R. Rogers2, J. A. Tomsick2

1 University of California, San Diego, Astronomy & Astrophysics, San Diego, California, United States of America
2 University of California, Berkeley, Space Sciences Laboratory, Berkeley, California, United States of America
3 NASA Goddard Space Flight Center, Greenbelt, Maryland, United States of America

Abstract

The Compton Spectrometer and Imager (COSI) is a NASA Small Explorer satellite mission scheduled for launch in August 2027. COSI’s imaging capabilities are achieved by reconstructing Compton scattering events within a 2 x 2 x 4 stack of germanium detectors (GeDs). Each GeD contains orthogonal electrode strips on opposite faces of the detector, forming an x-y grid. An incident gamma ray interacts with the GeD by depositing energy in one or more strips on each face that are then read out simultaneously. The “strip pairing” algorithm reconstructs the 2D position of each scatter by comparing the measured energies on pairs of orthogonal strips through a reduced chi square statistic. While simple for a single-site event, the matching becomes more complex when considering multiple scatters within a detector, multiple scatters on a single strip, or charge sharing between neighboring strips. Here, we describe the strip pairing algorithm and how it is implemented into the COSI pipeline. We then test the algorithm's efficacy and use it to demonstrate the imaging and spectral performance of a COSI GeD. Using a 137Cs calibration source and a single test detector, we find that the pipeline reconstructs the source's position and yields an energy resolution of less than 1% full width at half maximum at 662 keV.

AcknowledgmentThis work was supported in part by the Compton Spectrometer and Imager, a NASA Explorer project led by the University of California, Berkeley with funding from NASA, United States under contract 80GSFC21C0059.
References
[1] A. C. Zoglauer, “First light for the next generation of Compton and pair telescopes,” Ph.D. dissertation, Technical University of Munich, Germany, Jan. 2005.
[2] F. R. Rogers et al., “Depth calibration of double-sided strip germanium detectors for the Compton Spectrometer and Imager satellite,” Nuclear Instruments and Methods in Physics Research A, vol. 1086, p. 171332, Jun. 2026.
[3] J. Tomsick et al., “The Compton Spectrometer and Imager,” in 38th International Cosmic Ray Conference, Sep. 2024, p. 745.
Keywords: gamma-ray detector, germanium radiation detector
15:00 Poster panel: 55

Poster Number:
NSS-01-055

Temperature-Dependent Charge Transport in Diamond Radiation Detectors (#1377)

O. A. Johnson1, 2, R. Fitzhugh2, E. Lukosi1

1 University of Tennessee Knoxville, Nuclear Engineering, Knoxville, Tennessee, United States of America
2 Y-12 National Security Complex, Oak Ridge, Tennessee, United States of America

Abstract

Semiconductor radiation detectors are often limited due to thermal degradation of their electrical properties: as temperature increases, thermally activated carrier generation and other effects lead to elevated leakage currents and reduced signal to noise ratios. For more extreme environments such as advanced reactors and molten salt environments, detectors which operate at high temperatures are needed. Diamond, with its wide 5.47 eV bandgap, high carrier mobility, and radiation hardness is a promising material. Previous work in literature reported charge collection efficiency degradation in diamond at 230 °C, followed by recovery and stability of operation to 450 °C. However, this result has not been widely validated. This study evaluates three diamond samples of varying thickness at elevated temperatures, reevaluating carrier mobility and charge collection efficiency. Alpha traces at each temperature are analyzed to study the current transients, gaining insight into how thermal variations impact detector performance and mechanisms driving charge transport variation.

AcknowledgmentThe information, data or work presented herein was funded in part by the Advanced Research Project Agency-Energy (ARPA-E), U.S. Department of Energy, under award
Number DE-AR0001603. This work was also supported in part by Consolidated Nuclear Security, LLC (CNS) as accounts of work sponsored by an agency of the United
States Government under Contract DE‑NA‑0001942 and under subcontract number 4300189680, both related to the operation of Y-12 National Security Complex.
Neither the United States Government nor any agency thereof, nor CNS, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or
responsibility to any non-governmental recipient hereof for the accuracy or usefulness of any information. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency or contractor thereof.
Keywords: High-Temperature, Spectroscopy, Transient-Currents, Diamond
15:00 Poster panel: 57

Poster Number:
NSS-01-057

Monitoring neutron exposure in hyper-pure germanium detectors with in-situ capture reactions (#1736)

T. Round1, B. Green1, S. Croft1, J. Moore2, A. Metcalfe1, M. J. Joyce1

1 Lancaster University, Engineering Department, Lancaster, United Kingdom
2 NSG Environmental, Chorley, United Kingdom

Abstract

The potential to monitor neutron exposure in hyper-pure germanium detectors via capture-g reactions in the germanium crystal is explored.  The short-lived reactions on 70Ge and 74Ge resulting in g rays in the 130 to 200 keV energy region have been studied in terms of their response to thermalization of neutrons incident on portable, mechanically cooled, reverse-electrode hyper-pure germanium detectors (REGeTM). The relative sensitivity in terms of y rays emitted per unit neutron flux is estimated and a comparison is made with the inelastic response observed at higher energies, the latter often considered as cause of damage in such detectors.  We report the potential for these short-lived reactions to serve as a built-in neutron-sensitive diagnostic for germanium detector use in hot cells and realistic, mixed-field environments.

Acknowledgment

We acknowledge the support of NSG Ltd (Chorley, UK) and the UK Nuclear Decommissioning Authority.

References
[1] J-H. Chao, Appl. Rad. Isot. (1993) 44 (3) pp. 605-611, https://doi.org/10.1016/0969-8043(93)90177-C.
[2] N. Soppera, M. Bossant and E. Dupont, Nuclear Data Sheets, (2014) 120 pp. 294-296, https://doi.org/10.1016/j.nds.2014.07.071.
[3] S. He et al., Anal. Methods, (2014) 6 (12) pp. 4402–4407, https://doi.org/10.1039/c4ay00068d
[4] L. Szentmiklósi, J. Radioanal. Nucl. Chem. 315 (2018) pp. 663-670, https://doi.org/10.1007/s10967-017-5589-z
Keywords: hyper-pure germanium, neutron damage, neutron activation, y-ray spectroscopy
15:00 Poster panel: 59

Poster Number:
NSS-01-059

Pixel Architecture Effects on Neutron-Induced White Spot Generation in CMOS Image Sensors (#1811)

J. Jeong1, S. Kim2, J. Lim2, S. Lee2, I. Kwon1

1 Yonsei University, Radiation Convergence Engineering, Wonju, Republic of Korea
2 Samsung Electronics, Whaseong, Republic of Korea

Abstract

This paper quantifies how pixel structural parameters, specifically pitch, photodiode type, and transfer gate design, independently influence neutron-induced white spot generation in CMOS image sensors. Six sensor families with pixel pitches of 0.64, 0.70, 1.00, 1.12, and 1.20 μm, covering single and dual photodiode configurations and single and dual transfer gate designs, were irradiated with neutrons at the TRIUMF facility across seven cumulative fluence steps up to approximately 7×10⁸ n/cm². Ten samples per family were used, with dark-frame measurements performed at each step using eight-frame averaged images. White spot fractions were extracted using a baseline-subtracted delta counting method with Arrhenius-based temperature correction applied to the radiation-induced component. All six families exhibit a clear power-law dependence of white spot fraction on fluence. Spatial analysis reveals a monotonic increase in the 3×3 cluster ratio, defined as the ratio of the summed dark signal increase in neighboring pixels to that of the center hot pixel, from 0.14 at 1.20 μm to 0.24 at 0.64 μm, and this metric remains independent of fluence. A two-stage meta-regression model shows that increasing pitch from 0.64 to 1.20 μm raises the power-law amplitude by 2.12 times, adopting dual photodiode sharing raises it by 2.35 times, and employing a dual transfer gate reduces it by 0.49 times. Furthermore, the model is extended to predict white spot fractions for unmeasured pixel configurations, with potential for radiation-tolerant CIS design.

References
[1] J. R. Srour, C. J. Marshall and P. W. Marshall, "Review of displacement damage effects in silicon devices," in IEEE Transactions on Nuclear Science, vol. 50, no. 3, pp. 653-670, June 2003, doi: 10.1109/TNS.2003.813197.
[2] J. R. Srour and J. W. Palko, "Displacement Damage Effects in Irradiated Semiconductor Devices," in IEEE Transactions on Nuclear Science, vol. 60, no. 3, pp. 1740-1766, June 2013, doi: 10.1109/TNS.2013.2261316.
[3] C. Virmontois et al., "Displacement Damage Effects Due to Neutron and Proton Irradiations on CMOS Image Sensors Manufactured in Deep Submicron Technology," in IEEE Transactions on Nuclear Science, vol. 57, no. 6, pp. 3101-3108, Dec. 2010, doi: 10.1109/TNS.2010.2085448.
[4] J.-M. Belloir, V. Goiffon, C. Virmontois, M. Raine, P. Paillet, O. Duhamel, M. Gaillardin, R. Molina, P. Magnan, and O. Gilard, “Pixel pitch and particle energy influence on the dark current distribution of neutron irradiated CMOS image sensors,” Optics Express, vol. 24, no. 4, pp. 4299–4315, Feb. 2016, doi: 10.1364/OE.24.004299.
[5] V. Goiffon, M. Estribeau, P. Cervantes, R. Molina, M. Gaillardin and P. Magnan, "Influence of Transfer Gate Design and Bias on the Radiation Hardness of Pinned Photodiode CMOS Image Sensors," in IEEE Transactions on Nuclear Science, vol. 61, no. 6, pp. 3290-3301, Dec. 2014, doi: 10.1109/TNS.2014.2360773.
[6] S. Place, J. -P. Carrere, S. Allegret, P. Magnan, V. Goiffon and F. Roy, "Radiation Effects on CMOS Image Sensors With Sub-2 μm Pinned Photodiodes," in IEEE Transactions on Nuclear Science, vol. 59, no. 4, pp. 909-917, Aug. 2012, doi: 10.1109/TNS.2012.2193671.
Keywords: CMOS image sensors, neutron radiation effects, pixel pitch, transfer gate, photodiode
15:00 Poster panel: 61

Poster Number:
NSS-01-061

Characterisation of edge-on fully-depleted monolithic CMOS silicon sensors (#1882)

M. Barbagiovanni1, 2, A. Bjorklid3, A. Bortone2, R. Brunskog6, M. Da Rocha Rolo2, M. Danielsson6, A. Elihar3, U. Follo2, S. Garbolino2, J. Hartman4, J. Herzen7, D. John7, F. L. Klaus7, C. Mogler7, L. Pancheri5, J. Parnell7, 6, M. Persson6, E. Posteraro1, 2, M. Sjolin3, M. Y. Tamm6, S. Wirtensohn7

1 Politecnico di Torino, Electronics and Telecommunications, Turin, Italy
2 INFN Sezione Torino, Turin, Italy
3 Prismatic Sensor, Stockholm, Sweden
4 Karolinska Institutet, Stockholm, Sweden
5 Università di Trento, Trento, Italy
6 KTH Royal Institute of Technology, Stockholm, Sweden
7 TUM, Munich, Germany

On behalf of 1MICRON Collaboration

Abstract

Monolithic silicon CMOS Sensors represent a considerable step forward in charged particle and photon sensing, and emerge as a promising embodiment for the design of novel deep-silicon photon-counting X-ray Computed Tomography scanners . This work presents the first characterization of the ARCADIA MD3 Fully-Depleted CMOS sensors, which technology is currently the baseline for the development of innovative sensors under the framework of the EIC Pathfinder Open 1MICRON project. We report on the characterisation results using an edge-on geometry and a focused synchrotron X-ray beam at the DESY test facility. The x-rays impinge on the edge of the sensor, increasing the active sensor depth seen by the photons, which consequently improves the quantum efficiency with respect to a face-on configuration. A 37 keV focused beam incident parallel to the sensor surface allowed scans along the two directions of the sensor edge, enabling the extraction of the active sensor thickness and mechanical tilt via pixel intensity profiles. Lateral scans across pixel boundaries revealed a periodicity of the spatial modulation of mean cluster size compatible with the pixel pitch of the matrix. Taking the cluster size as the main figure of merit, the performance of the sensor was evaluated at different thresholds and multiple bias voltages in order to assess the variation in the Coulomb cone and collection dynamic. The measurements are supported by Allpix Squared Monte Carlo framework, demonstrating good consistency between the simulated and the real domain.

AcknowledgmentThis study was carried out with support from the INFN CSN5 Call ARCADIA. This work was supported by the European Union’s Horizon Europe research and innovation programme under the 1MICRON project – “New Technology for 1 MICRON Resolution Biomedical Imaging” (grant agreement No. 101186826).
References
[1] Da Rocha Rolo, Manuel 2025 'Arcadia fully depleted cmos maps development
with lfoundry 110 nm cis', Frontiers in Sensors, vol. Volume 6 - 2025
[2] Bergamaschi, A., 2005, 'Edge on silicon microstrip detectors for medical
imaging', Nuclear Instruments and Methods in Physics Research Section
A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.
549, no. 1, pp. 199–204, Sep. 2005
Keywords: Monolithic CMOS Silicon Sensor, Deep-silicon, X-ray imaging, Clinical CT
15:00 Poster panel: 63

Poster Number:
NSS-01-063

Gain suppression study on LGADs with different gain layer designs (#2025)

L. Cavazzini1, 2, A. Bisht1, M. Boscardin1, M. Centis Vignali1, M. Fernandez Garcia3, F. Ficorella1, O. Hammad Alì1, V. Kraus4, M. Moll5, G. Paternoster1, M. Wiehe5

1 Fondazione Bruno Kessler, Trento, Italy
2 University of Trento, Department of Physics, Trento, Italy
3 Instituto de Fisica de Cantabria, IFCA, Santander, Spain
4 TU Wien, Faculty of Physics,, Vienna, Austria
5 CERN, Geneva, Switzerland

Abstract

High-energy physics experiments currently use Low Gain Avalanche Diodes (LGADs) as part of their time-of-flight layers to track particles, thanks to their unique temporal resolution and radiation hardness. With increasing deposited charge, the gain was observed to decrease. This gain suppression effect originates from the electrostatic field screening produced by the avalanche multiplication charge. This work investigates the resilience of the LGADs to the gain suppression by characterizing a set of detectors with different gain layer designs and thicknesses, using Transient Current Techniques.

References
[1] G. Pellegrini et al. “Technology developments and first measurements of Low Gain Avalanche Detectors (LGAD) for high energy physics applications”. In: Nucl. Instrum. Meth. A.765 (2014), pp. 12–16. DOI: https://www.doi.org/10.1016/j.nima.2014.06.008.
[2] N. Cartiglia et al. “Beam test results of a 16 ps timing system based on ultra-fast silicon detectors”. In: Nucl. Instrum. Meth. A.850 (2017), pp. 83–88. DOI: https://www.doi.org/10.1016/j.nima.2017.01.021.
[3] E. Curras et al. “Gain reduction mechanism observed in Low Gain Avalanche Diodes”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1031 (May 2022), p. 166530. ISSN: 0168-9002. DOI: http://www.doi.org/10.1016/j.nima.2022.166530.
[4] Sebastian Pape et al. “TCAD Simulation of Two Photon Absorption—Transient Current Technique Measurements on Silicon Detectors and LGADs”. In: Sensors 24.24 (2024). ISSN: 1424-8220. DOI: https://doi.org/10.3390/s24248032.
Keywords: Detectors, Silicon, LGAD, Timing, GainSuppression
15:00 Poster panel: 65

Poster Number:
NSS-01-065

Pulse-Shape-Based Slow-Rising Pulse Rejection for Reliable Charge-Carrier Transport Characterization in a Semiconductor Radiation Detector (#2231)

J. Boo1, B. Park2, G. Kim1, 3

1 Seoul National University, Department of Energy Systems Engineering, Seoul, Republic of Korea
2 Seoul National University, Nuclear Research Institute for Future Technology and Policy (NIFTEP), Seoul, Republic of Korea
3 Seoul National University, Nuclear Engineering Department, Seoul, Republic of Korea

Abstract

Mobility (μ), lifetime (τ), and mobility–lifetime product (μτ) are key metrics for semiconductor radiation detectors. Highly concentrated trapping centers or defects can distort the internal electric-field distribution, producing reduced-amplitude slow-rising charge-sensitive preamplifier pulses that degrade carrier-transit and charge-collection analyses. Although slow-rising-pulse rejection is commonly used to sharpen pulse-amplitude peaks and suppress low-amplitude tails, this work extends its use to charge-carrier transport characterization. A CdZnTeSe detector [1, 2] was characterized at room temperature under electron- and hole-transit-dominant conditions using ²⁴¹Am alpha irradiation. Pulse-shape analysis rejected slow-rising pulses for key metrics extraction. In electron-transit-dominant measurements, the fast-rising pulse events preserved the bias-dependent peak-centroid trend and yielded (μτ)e = 5.7 × 10⁻⁴ cm²/V, μe = 576 cm²/V·s, and τe = 1.0 μs, consistent with reported values [3,4]. For hole-transit-dominant measurements, all-pulse events obscured the pulse-amplitude peak and hindered Hecht fitting. After rejection, we obtained (μτ)h = 2.1 × 10⁻⁴ cm²/V, τh = 0.7 μs, comparable to reported values [5], with μh = 318 cm²/V·s. Using the rise-time peak as the representative transit time, both all-pulse and fast-rising-pulse events yielded similar μh values. However, when the median rise time of all-pulse events was used instead, drift velocity did not show a clear linear dependence on electric field, whereas fast-rising-pulse events retained linearity. This reflects the need for careful consideration of slow-rising components and the transit-time definition. These results show that slow-rising-pulse rejection enables reliable transport characterization beyond spectral improvement.

AcknowledgmentThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (Ministry of Science and ICT) (No. 2022M2D2A1A02063826).
References
[1] Park, B., et al. 2022, 'Bandgap engineering of Cd1−xZnxTe1−ySey (0< x< 0.27, 0< y< 0.026)', Nucl. Instrum. Methods Phys. Res. A. 1036, 166836.
[2] Park, B., et al. 2024 'Fabrication and Evaluation of Spectroscopic Grade Quasi-hemispherical CdZnTe Detector', J. Radiat. Prot. Res. 49(2), 85-90.
[3] Kleppinger, J.W., et al. 2021, 'Growth of Cd0.9Zn0.1Te1–ySey single crystals for room-temperature gamma ray detection, IEEE Trans. Nucl. Sci. 68(9), 2429-2434.
[4] Chaudhuri, S.K., et al. 2021, 'Quaternary semiconductor Cd1−xZnxTe1−ySey for high-resolution, room-temperature gamma-ray detection', Crystals 11(7), 827.
[5] Pipek, J., et al. 2021, 'Charge transport and space-charge formation in Cd1−xZnxTe1−ySey radiation detectors', Phys. Rev. Appl. 15(5) 054058.
Keywords: Semiconductor radiation detector, Charge-carrier transport characterization, Charge-sensitive preamplifier waveform, Pulse-shape discrimination, Slow-rising pulse rejection
15:00 Poster panel: 67

Poster Number:
NSS-01-067

The Sensor, Packaging and INtegration (SPIN) group at Fondazione Bruno Kessler (FBK): capabilities, facilities and expertise (#2415)

D. Novel1, T. Facchinelli1, E. Demenev1, A. Lega1, P. Tosato1, S. Ferrari1

1 Fondazione Bruno Kessler, Trento, Italy

Abstract

This contribution presents the capabilities, infrastructure, and technical expertise of the Sensor, Packaging and Integration (SPIN) group at Fondazione Bruno Kessler (FBK). The SPIN unit has established experience in the miniaturisation and integration of electronic systems for radiation detectors, with demonstrated results in space instrumentation (e.g. THESEUS for ESA), high-energy physics (e.g. R&D for ALICE3), and medical applications (e.g. the BOA project within INFN). These domains impose stringent constraints on material budget, geometrical footprint, and signal integrity, motivating the development of dedicated integration strategies. The group core expertise lies in the co-design of sensors and front-end electronics for operation in highly constrained volumes, where standard packaging solutions are not applicable. This includes the optimisation of interconnect technologies (wire bonding, TAB, flip-chip), layout strategies and the implementation of low-noise architectures. Emphasis is placed on preserving signal integrity in high-density environments typical of modern detector systems. SPIN offers end-to-end capabilities covering system design, prototyping, assembly, and characterisation, supported by dedicated infrastructure for precision packaging and electrical testing. A key enabling technology is the use of flexible and hybrid electronics, allowing the development of low-mass, conformable interconnects and non-planar integration schemes. In particular, the group has developed dedicated processes for the fabrication and integration of ultra-thin Kapton-aluminium flexible circuits, optimised for low material budget and high mechanical compliance. These structures enable the realisation of fine-pitch routing on lightweight substrates, with controlled thickness and reduced radiation length, making them especially suitable for tracking detectors.

Keywords: Integration, Packaging, Bonding, Electronics, Silicon detectors
15:00 Poster panel: 69

Poster Number:
NSS-01-069

High-voltage stress test and thermal recovery of an amorphous-silicon-passivated planar HPGe detector (#2646)

L. Han1, 2, Y. Li1, 2, L. He1, 2, S. Yu1, 2, X. Li1, 3, M. Yang1, 2, Y. Li1, 2, Y. Tian1, 2

1 Tsinghua University, Department of Engineering Physics, Beijing, China
2 Ministry of Education, Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Beijing, China
3 Greater Bay Area National Center of Technology Innovation, Guangzhou, China

Abstract

High-purity germanium (HPGe) detectors are widely used in low-background and rare-event measurements because of their excellent energy resolution and relatively high detection efficiency. Compared with a-Ge, sputtered a-Si provides a higher electron-injection barrier, which is attractive for planar detectors under high electric fields. However, the high-voltage (HV) stability of a-Si contacts and the recovery from HV-induced large leakage-current and resolution degradation remain insufficiently understood. The detector was fabricated using a planar p-type HPGe crystal (φ24 mm × 10 mm). A Li-diffused n+ contact was used as the high-voltage electrode, while the opposite face was coated with an a-Si layer deposited by magnetron sputtering. A central Al pad was formed on the a-Si layer by thermal evaporation and used as the signal readout electrode. I–V curves were measured with a picoammeter up to 2500 V, and 57Co spectra were acquired at 500–2000 V using a DSPEC-50 digital spectrometer. The stress test consisted of repeated biasing up to 2000 V, followed by 9 hours of room-temperature storage and 9 hours of thermal treatment with the crystal holder maintained below 70 degrees. After the high-voltage stress test, the leakage current at 1000 V increased to approximately 1.1 nA, more than two orders of magnitude higher than the initial level. After thermal treatment below 70 degrees, the leakage current at 1000 V decreased to less than 2 pA, close to the as-fabricated level. At 1000 V, the resolution broadened to 1.53 keV FWHM, suggesting larger noise and contact-related instability under a higher electric field. After thermal treatment, the resolution at 500 V recovered to 0.67 keV FWHM, comparable to the initial value. In the future, we will repeat stress-recovery cycles, and investigate the dependence on treatment temperature and duration. The possible underlying recovery mechanism related to the a-Si fermi level will also be studied.

References
[1] Hull E L, Pehl R H, Lavietes A D, et al. Amorphous-semiconductor blocking contacts on Ge radiation detectors. Nuclear Instruments and Methods in Physics Research Section A, 2014, 762: 130-134.
[2] Looker Q, Amman M, Vetter K. Leakage current in high-purity germanium detectors with amorphous semiconductor contacts. Nuclear Instruments and Methods in Physics Research Section A, 2015, 777: 138-144.
[3] Yang M, Li Y, Zeng Z, et al. A prototype segmented planar high purity germanium detector using wraparound lithium diffusion electrode and amorphous germanium blocking contact. Radiation Detection Technology and Methods, 2022, 6(4): 433-438.
Keywords: HPGe, a-Si, High-voltage stress
15:00 Poster panel: 71

Poster Number:
NSS-01-071

Development of a SiC-Based Muon Beam Monitor for the COMET Experiment (#2912)

K. Okabe1, Y. Fukao2, Y. Igarashi2, Y. Fujita2, E. Hamada2, T. Kishishita3, K. Kojima4, R. Kosugi4, S. Mihara2, H. Nishiguchi2, M. Shoji2, Y. Tanaka4, Y. Yamaguchi5, Y. Yamada5

1 The Graduate University for Advanced Studies, Particle and Nuclear Physics Program, Tsukuba, Japan
2 High Energy Accelerator Research Organization, Institute of Particle and Nuclear Studies, Tsukuba, Japan
3 Universität Bonn, Physikalisches Institut, Bonn, North Rhine-Westphalia, Germany
4 National Institute of Advanced Industrial Science and Technology, Advanced Power Electronics Research Center, Tsukuba, Japan
5 University of Tsukuba, Faculty of Engineering, Information and Systems, Tsukuba, Japan

Abstract

The COMET Experiment at J-PARC aims to search for the muon-to-electron conversion process with a sensitivity of 10−17. In COMET Phase-I, the muon beam monitor (MBM) will be installed downstream of the primary detector system for background suppression and precise beam control. Since the MBM directly measures the high-intensity muon beam, silicon carbide (SiC), one of the wide-bandgap semiconductors with higher radiation tolerance, is employed as the detector material. The SiC sensor was jointly developed by KEK and AIST, and a beam test performed at J-PARC MLF in 2024 showed successful muon detection and sufficient linearity for operation in the COMET Experiment. In addition, a radiation-tolerant ASIC currently under development at KEK is planned for the SiC detector readout. While the initial prototype MBM board utilised a two-layer polyimide PCB to minimise the material budget, it suffered from external noise and inter-channel crosstalk, obscuring low-amplitude beta-ray signals. To address this and optimise the final MBM board design, we developed a test board equipped with seven SiC detectors. This study showed that noise can be reduced by implementing appropriate noise mitigation techniques, such as a ground plane in a standard PCB structure, enabling stable waveform acquisition of low-amplitude beta-ray signals. In addition, inter-channel crosstalk was effectively suppressed to a negligible level by introducing low-pass filters on the bias supply lines close to each detector. Based on these findings, a prototype MBM board for the final system is currently being developed. This presentation also reports on its design and initial performance evaluation.

AcknowledgmentThis work was supported by JSPS KAKENHI Grant Numbers JP21H01117, JP22H00139, JP25K07348, and JST SPRING, Japan Grant Number JP-MJSP2104.
References
[1] R. Abramishvili et al., “COMET Phase-I Technical Design Report,” PTEP, vol. 2020, no. 3, p. 033C01, 2020.
[2] T. Kishishita et al., “SiC p+n Junction Diodes Toward Beam Monitor Applications,” IEEE Trans. Nucl. Sci., vol. 68, no. 12, pp. 2787–2793, 2021.
[3] K. Okabe et al., “Performance review of the prototype SiC muon beam monitor for COMET experiment,” Nucl. Instrum. Meth. A, vol. 1080, p. 170798, 2025
Keywords: COMET experiment, Lepton flavour violation, Semiconductor detectors, Silicon carbide
15:00 Poster panel: 73

Poster Number:
NSS-01-073

Argon Ion-Assisted Polycrystalline PbO Layers for Direct-Conversion X-ray Imaging Detectors (#3080)

M. Vostokov1, J. Rado1, G. Nagicheva1, A. Stieh1, A. Alexandrov1, A. Reznik1

1 Lakehead University, Physics Department, Thunder Bay, Ontario, Canada

Abstract

Lead oxide (PbO) is a high-atomic-number photoconductor for direct-conversion X-ray imaging. This work compares PbO layers produced by three deposition regimes: conventional physical vapor deposition from molten PbO powder, oxygen ion-assisted PVD, and argon ion-assisted PVD. All layers were deposited on indium tin oxide coated glass substrates with a polyimide blocking layer to reduce dark current and were characterized by scanning electron microscopy, Raman spectroscopy, profilometry, density measurements, and X-ray photoconductivity.

Deposition without ion assistance produced low-density polycrystalline PbO with noticeable lag in the X-ray response after irradiation. Oxygen ion-assisted growth yielded dense amorphous PbO with essentially lag-free temporal response. In contrast, argon ion-assisted deposition preserved the polycrystalline structure while producing a more uniform layer with intermediate density and needle-like surface crystallites. X-ray photocurrent measurements showed that the argon-assisted films had an electron–hole pair creation energy, W±, of approximately 6 eV/ehp at 10 V/µm, close to the fundamental limit. Under 30 Hz modulated X-ray irradiation, these films showed stable photocurrent during exposure and rapid signal decay after irradiation stopped, indicating negligible lag.

Acknowledgment

This research was supported by Teledyne DALSA and Natural Sciences and Engineering Research Council of Canada Discovery and Alliance programs, MITACS. The authors gratefully acknowledge their support.

References
[1] S. O. Kasap, J. B. Frey, G. Belev, O. Tousignant, H. Mani, J. Greenspan, L. Laperriere, O. Bubon, A. Reznik, G. DeCrescenzo, K. S. Karim, and J. A. Rowlands, "Amorphous and polycrystalline photoconductors for direct conversion flat panel X-ray image sensors," Sensors, vol. 11, no. 5, pp. 5112-5157, 2011, doi: 10.3390/s110505112.
[2] O. Grynko and A. Reznik, "Progress in lead oxide X-ray photoconductive layers," in Photoconductivity and Photoconductive Materials, S. O. Kasap, Ed. Hoboken, NJ, USA: Wiley, 2022, ch. 16, pp. 643-688, doi: 10.1002/9781119579182.ch16.
[3] O. Semeniuk, O. Grynko, G. DeCrescenzo, G. Juska, K. Wang, and A. Reznik, "Characterization of polycrystalline lead oxide for application in direct conversion X-ray detectors," Scientific Reports, vol. 7, Art. no. 8659, 2017, doi: 10.1038/s41598-017-09154-w.
[4] O. Semeniuk, O. Grynko, G. Juska, and A. Reznik, "Amorphous lead oxide (a-PbO): suppression of signal lag via engineering of the layer structure," Scientific Reports, vol. 7, Art. no. 13272, 2017, doi: 10.1038/s41598-017-13572-7.
[5] O. Grynko, T. Thibault, E. Pineau, and A. Reznik, "Engineering of a blocking layer structure for low-lag operation of the a-PbO-based X-ray detector," IEEE Trans. Electron Devices, vol. 68, no. 5, pp. 2335-2341, May 2021, doi: 10.1109/TED.2021.3067616.
[6] A. Reznik and O. Semeniuk, "Lead oxide as material of choice for direct conversion detectors," in Oxide Electronics, 2021, ch. 7, doi: 10.1002/9781119529538.ch7.
Keywords: argon ion assistance, direct-conversion X-ray detectors, lead oxide, polycrystalline PbO, X-ray photoconductivity
15:00 Poster panel: 75

Poster Number:
NSS-01-075

Quantum Dots-Based Short-Wave Infrared Avalanche Photodetectors (#1295)

S. Fang1, 3, X. Wei2, 3

1 Chongqing University of Posts and Telecommunications, Chongqing, China
2 Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing, China
3 Chongqing School, University of Chinese Academy of Sciences, Chongqing, China

Abstract

Short-wave infrared photodetectors based on colloidal quantum dots (QDs) have attracted substantial attention owing to their solution processability, tunable bandgaps, and natural compatibility with silicon-based readout integrated circuits. However, the performance of QDs photodetectors is fundamentally limited by the low intrinsic carrier mobility of colloidal QDs, which significantly hinders charge transport. In addition, conventional detector architectures typically provide insufficient internal gain, thereby restricting detection sensitivity, particularly under weak infrared illumination. To address these challenges, we propose a hybrid avalanche photodetector that integrates a halogen-passivated PbS QDs absorption layer with a silicon multiplication region. After absorbing incident infrared photons in the QDs layer, photoexcited electrons are efficiently injected into the silicon multiplication region. The accelerated carriers then induce impact ionization, which enables strong avalanche multiplication and yields high internal gain for efficient carrier collection. Technology Computer-Aided Design (TCAD) simulations indicate that the proposed device delivers a responsivity of 29.5 A/W at a wavelength of 1550 nm, accompanied by fast rise and fall times of 305 ps and 306 ps, respectively. By integrating the spectral tunability of PbS QDs with the robust avalanche gain offered by mature silicon platforms, this architecture provides a highly promising, CMOS-compatible route toward next-generation, high-sensitivity infrared photodetection.

AcknowledgmentThis work is supported by National Key Research and Development Program of China (2024YFE0211900) and the Natural Science Foundation of Chongqing of China (CSTB2023NSCQ-LZX0087) .
References
[1] F. de Arquer, D. Talapin, V. Klimov, et al., ‘Semiconductor quantum dots: Technological progress and future challenges,’ Science, vol. 373, no. 6555, pp. eaaz8541, American Association for the Advancement of Science
[2] Y. Wang, C. Deng, J. Liu, et al., ‘Interface Engineering Enables High-performance PbS Colloidal Quantum Dots Imager via Tungsten Oxide Hydrophilic Layer,’ Laser & Photonics Reviews, vol. 19, no. 19, pp. 9, Wiley-VCH
[3] J. Liu, P. Liu, D. Chen, et al., ‘A near-infrared colloidal quantum dot imager with monolithically integrated readout circuitry,’ Nature Electronics, vol. 5, no. 7, pp. 443–451, Springer Nature
[4] C. Hartley, and J. Dempsey, ‘Revealing the Molecular Identity of Defect Sites on PbS Quantum Dot Surfaces with Redox-Active Chemical Probes,’ Chemistry of Materials, vol. 33, no. 7, pp. 2655–2665, American Chemical Society
[5] J. Fu, C. Leng, R. Ma, et al., ‘Photo-driven fin field-effect transistors,’ Opto-Electronic Science, vol. 3, no. 5, pp. 230046, Science Press
[6] X. Xiao, K. Xu, M. Yin, et al., ‘High quality silicon: Colloidal quantum dot heterojunction based infrared photodetector,’ Applied Physics Letters, vol. 116, no. 10, pp. 4, American Institute of Physics
[7] G. Whitworth, M. Dalmases, N. Taghipour, et al., ‘Solution-processed PbS quantum dot infrared laser with room-temperature tunable emission in the optical telecommunications window,’ Nature Photonics, vol. 15, no. 10, pp. 738–742,Springer Nature
Keywords: Quantum dots, Avalanche photodetector, CMOS, Responsivity, Infrared photodetection
15:00 Poster panel: 77

Poster Number:
NSS-01-077

Characterization and Radiation Damage Mitigation of Silicon Photomultipliers for Low Earth Orbit Applications (#1902)

S. Davarpanah1

1 Université de Genève, Département de physique nucléaire et corpusculaire, Genève, Genève, Switzerland

On behalf of NUSES Collaboration

Abstract

Silicon photomultipliers (SiPMs) are attractive photosensors for space applications because of their compact size, low cost, low operating voltage, high photon detection efficiency (PDE), and single-photon sensitivity. Their use in space applications, however, is limited by radiation-induced increases in dark count rate (DCR). This work presents the characterization and radiation tolerance study of FBK NUV-HD-MT SiPMs for the focal plane of the Terzina Cherenkov telescope onboard the NUSES mission, which will operate in a Sun-synchronous low Earth orbit (LEO) at an altitude of approximately 550 km. Devices with micro-cell sizes ranging from 25 to 50 μm were evaluated through a comprehensive characterization campaign comprising static (current-voltage), dynamic (noise and pulse-shape), and optical (photon detection efficiency) measurements to identify the sensor configuration best suited for this application. The 30 μm bare sensors were selected as the optimal solution, achieving a PDE greater than 50% at 400 nm, optical cross-talk below 2%, and a DCR below 60 kHz/mm2 at 10 V overvoltage. The radiation environment was modeled using SPENVIS, and dose deposition in the focal plane was evaluated with Geant4 simulations. In parallel, radiation effects were investigated experimentally through two irradiation campaigns: a 50 MeV proton beam test and electron exposure using a Sr-90 source. Proton-induced damage produced a significant increase in leakage current and DCR, while electron-induced degradation was substantially smaller. Temperature-dependent measurements were used to extrapolate in-orbit performance and to evaluate recovery through thermal annealing. The results indicate that performing periodic annealing cycles at temperatures above 50°C can reduce the radiation-induced current by up to 40% after approximately 84 hours, helping preserve detector performance over the three-year mission.

References
[1] NUSES Collaboration, “The NUSES space mission,” PoS TAUP2023, p. 121, 2024.
[2] NUSES collaboration, The NUSES space mission, J. Phys. Conf. Ser. 2429 (2023) 012007.
[3] L. Burmistrov, “Terzina on board NUSES: A pathfinder for EAS Cherenkov light detection from space,” EPJ Web Conf., vol. 283, p. 06006, 2023.
[4] L. Burmistrova, S. Davarpanah, M. Heller, T. Montaruli, C. Trimarelli, R. Aloisio, et al., “Performance and radiation damage mitigation strategy for silicon photomultipliers on LEO space missions,” J. Cosmol. Astropart. Phys., vol. 2025, no. 07, p. 073, Jul. 2025.
[5] T. Montaruli and A. Nagai, “Properties of large SiPM at room temperature,” Nucl. Instrum. Methods Phys. Res. A, vol. 985, p. 164609, 2021.
[6] A. Nagai, C. Alispach, D. Della Volpe, M. Heller, T. Montaruli, S. Njoh, et al., “SiPM behaviour under continuous light,” JINST, vol. 14, p. P12016, 2019.
[7] Spenvis: The space environment information system, 2022.
[8] Geant4: Toolkit for the simulation of the passage of particles through matter. its areas of application include high energy, nuclear and accelerator physics, as well as studies in medical and space science, 2019.
[9] J. Swakon, P. Olko, D. Adamczyk, T. Cywicka-Jakiel, J. Dabrowska, B. Dulny et al., Facility for proton radiotherapy of eye cancer at ifj pan in krakow, Radiation Measurements 45 (2010) 1469.
Keywords: Silicon photomultipliers, Cherenkov telescope, radiation damage, Annealing, space instrumentation
15:00 Poster panel: 79

Poster Number:
NSS-01-079

Toward SiPM Single-Photon Detection Matrix using Ultrafast, Low Power RF Readout (#1939)

R. Belkacem1, D. F. Yvon1, 4, D. Baudin2, D. Breton3

1 CEA Saclay / Univ. Paris-Saclay, IRFU/DPhP, Gif sur Yvette, France
2 CEA Saclay / Univ. Paris-Saclay, IRFU/DEDIP, Gif sur Yvette, France
3 CNRS-IN2P3/ Univ. Paris-Saclay, IJCLab, Orsay, France
4 UMR BioMaps/ Univ. Paris-Saclay, Orsay, France

Abstract

To enable the readout of fast signals from SiPM arrays, we have developed a SiPM chip readout based on a compact, low-power radio-frequency preamplifier, thus avoiding the use of ASICs. On a 16 mm² SiPM operating in single photoelectron mode, we measure a rise time of 450 ps and a timing resolution (SPTR) of 84 ps (FWHM), while amplifying the fast component of the SiPM pulses. Furthermore, the active output impedance of the preamplifier is on the order of kΩ, allowing these chips to be mounted along a transmission line without significantly affecting signal propagation. This enables the implementation of dense SiPM lines or arrays, reducing the number of digitization channels required for readout. Finally, an optimized passive pole-zero compensation network, placed at the ends of the line, suppresses the slow component of the SiPM pulses and achieves critical damping of the fast pulse shapes. Thus, pulse pile-up, expected during multiplexing of SiPM photodetectors, can be controlled even at high counting rates. We are currently working on the assembly of such SiPM arrays. We measured a Coincidence Time Resolution of 69 ps (FWHM) using a 9 mm3 LYSO crystal + SiPM spectrometers with our readout electronics.

References
 [1] J. Huizenga et al., Nucl. Instrum. Meth. A 695 (2012) 379
[2] H. Kim et al., Nucl. Instrum. Meth. A 784 (2015) 557–564
[3] J. W. Cates et al., Phys. Med. Biol. 63 (2018) 185022
[4] S. Gundacker et al., Phys. Med. Biol. 65 (2020) 025001
Keywords: SiPM, Fast Photodetection, Matrix Multiplexing, RF Readout, Gamma Spectrometers
15:00 Poster panel: 81

Poster Number:
NSS-01-081

FPGA-Based Real-Time SiPM Emulator with Sub-Nanosecond Temporal Quantization (#1987)

A. Abba1, S. Carsi1, F. Caponio1, E. Proserpio1, 2, V. Arosio1

1 Nuclear Instruments SRL, Lambrugo, Italy
2 Università dell'Insubria, Como, Italy

Abstract

This work presents a real-time FPGA-based Silicon Photomultiplier (SiPM) detector emulator capable of reproducing physically accurate detector waveforms at 16-bit resolution and 2.5 GS/s analog output rate. The proposed architecture combines microscopic event simulation with a temporally quantized event-streaming model, enabling real-time waveform synthesis directly inside FPGA logic while drastically reducing bandwidth requirements compared to traditional waveform streaming approaches. The emulator separates event generation from signal shaping: software layers generate timestamped photon-hit sequences derived either from analytical distributions, Geant4 simulations, or SimSiPM microscopic detector models, while the FPGA reconstructs the analog waveform through parallel Infinite Impulse Response (IIR) filter banks implementing the SiPM transfer function; a look-ahead recursive transformation enables II = 1 operation across all banks at 156.25 MHz, consuming approximately 235 DSP48E2 slices. A multi-phase temporal quantization architecture provides 0.8 ns effective timing precision using a 156.25 MHz fabric clock and eight temporal sub-phases. Experimental validation demonstrates excellent agreement between hardware-generated waveforms and analytical as well as SimSiPM-generated references, including pile-up scenarios with overlapping scintillation events reproduced through linear superposition. The prototype operates with an end-to-end latency of approximately 83 ns.

Keywords: Detector emulator, FPGA, real-time systems, Silicon Photomultipliers, waveform synthesis
15:00 Poster panel: 83

Poster Number:
NSS-01-083

Design and Single-Cell Verification of an Integrated Temperature-Compensation Architecture for Digital SiPMs in Extreme Environments (#2580)

O. Jinseok1, H. Seop2, K. Seo-Ryong2, K. Inyong3

1 Korea University of Science and Technology (UST), Daejeon, Republic of Korea
2 Korea Atomic Energy Research Institute (KAERI), Daejeon, Republic of Korea
3 Yonsei University, Wonju, Republic of Korea

Abstract

This paper presents the single-cell design and verification of a digital SiPM building block with an integrated temperature-compensation architecture that eliminates external sensors by exploiting SPAD output-amplitude tracking as an intrinsic thermal indicator. A low-power SPAD with a P+/N-well junction and P-well guard ring was fabricated in a 180 nm CMOS process, exhibiting a 10.3 V breakdown voltage, while the digital-cell employs a high-speed comparator to suppress pulse-width variation and premature edge breakdown. The extracted amplitude trend drives an integrated PMIC in a closed loop to dynamically adjust the SPAD bias, maintaining a constant overvoltage and providing instantaneous compensation for thermal drifts.

AcknowledgmentThis work was supported in part by the National Research Foundation (NRF) funded by the Korean government (MSIT) (RS-2025-04162969, RS-2022-00144324, RS-2022-00144419, and RS-2022-00165164), the Regional Innovation System & Education (RISE) program through the Gangwon RISE Center, funded by the Ministry of Education (MOE) and the Gangwon State (G.S.), Republic of Korea. (2025-RISE-10-006), the National Research Council of Science & Technology (NST) grant by the Korea government (MSIT) (No. GTL25051-000), and the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (RS-2026-00144324).
References
[1] C. Veerappan and E. Charbon, "A Low Dark Count p-i-n Diode Based SPAD in CMOS Technology," IEEE Transactions on Electron Devices, vol. 63, no. 1, pp. 65–71, Jan. 2016, doi: 10.1109/TED.2015.2475355.
[2] F. Nolet et al., "A 2D Proof of Principle Towards a 3D Digital SiPM in HV CMOS With Low Output Capacitance," IEEE Transactions on Nuclear Science, vol. 63, no. 4, pp. 2293–2299, Aug. 2016, doi: 10.1109/TNS.2016.2582686.
[3] F. Licciulli and C. Marzocca, "An Active Compensation System for the Temperature Dependence of SiPM Gain," IEEE Transactions on Nuclear Science, vol. 62, no. 1, pp. 228–235, Feb. 2015, doi: 10.1109/TNS.2015.2388580.
Keywords: Digital SiPM, Temperature-compensation, Amplitude tracking, Low-power
15:00 Poster panel: 85

Poster Number:
NSS-01-085

Graphene Photodetectors for Vacuum-UV Through Visible Wavelengths (#3124)

A. Lindman1, M. Turqueti1, L. Schlueter1, G. R. Araujo2

1 Lawrence Berkeley National Laboratory, Berkeley, United States of America
2 University of Zurich, Zurich, Switzerland

Abstract

Many experiments rely on measuring vacuum-ultraviolet light, which is emitted in situations as diverse as scintillation in cryogenic liquid noble gases (126.8 nm in argon) and laser spectroscopy of atomic hydrogen isotopes (121.6 nm). Graphene-monolayer photodetectors offer several attractive traits: they are naturally thin, sensitive to a broad range of wavelengths, relatively simple to fabricate (including with integrated readout circuitry with the same process), and can be made on flexible substrates. We present measurements with visible and UV light down to 115 nm, including at low intensity and with fast pulses, of graphene field-effect transistors (GFETs) of various sizes up to 2 mm square fabricated on silicon. These detectors show promise for experiments from neutrinoless double beta decay searches to absolute neutrino mass measurements, as well as dark-matter searches or other VUV-detection applications.

Acknowledgment

This work was supported by the U.S. Department of Energy through the Laboratory Directed Research and Development program. 

Keywords: Graphene, field effect transistors, photodetectors
15:00 Poster panel: 87

Poster Number:
NSS-01-087

Development of a PLL-less 6.25Gbps Serializer and CML Transmitter for the LCLS-II Upgrade (#1129)

G. Liu1, H. Sandberg1, A. Pena Perez1, B. Markovic1, A. Gupta1, H. Kim1, L. Rota1, D. Doering1, L. Ruckman1

1 Stanford University, SLAC National Accelerator Laboratory, Menlo Park, California, United States of America

Abstract

Linac Coherent Light Source (LCLS) at SLAC National Laboratory has been going through a major upgrade, called LCLS-II, where the repetition rates are increasing from 120Hz to almost a MegaHertz. Custom ASICs that support x-ray data measurements at these rates are in development for both full frame and sparse data readout. For these ASIC designs we are departing from conventional internal PLL architectures, and instead implementing a 6.25 Gbps serializer with high-speed current-mode logic (CML) receivers (for clock) and transmitters (for data). This approach simplifies the whole chip design, reduces the power consumption and minimizes the noise sensitivity between the high-speed data path and the low-noise front-end blocks. This paper presents detailed performance measurements in a prototype ASIC, followed by the description of their circuit design and implementation.

AcknowledgmentWork supported by the U.S. Department of Energy, under contract number DE-AC02-76SF00515.
Keywords: PLL, High-Speed Data Transmission, Serializer, Particle Accelerator Instrumentation, Application-Specific Integrated Circuit (ASIC)
15:00 Poster panel: 89

Poster Number:
NSS-01-089

Performance Evaluation of Differential Amplifiers for Fast Scintillating Fiber Readout in Proton Therapy (#1449)

B. Deniz1, 2, A. Eksim1, 2

1 TUBITAK BILGEM, KOCAELI, Turkey
2 Gebze Technical University, KOCAELI, Turkey

Abstract

Real time range verification in proton therapy requires analog front end electronics that can process fast, low amplitude signals from scintillating fibers with sub nanosecond precision. This work compares two COTS differential amplifiers (ADA4930 vs. ADA4938) for the NOVO project’s detector. Using actual scintillator derived PWL pulses (0.3 V peak, 18 ns rise time) and a 5th order 250 MHz Butterworth filter, we show that small signal bandwidth governs transient performance. The ADA4930 achieved 660 V/µs pre filter and 350.56 V/µs post filter slew rate, versus 550 and 289.44 V/µs for the ADA4938. Noise analysis reveals the ADA4930 is “resistor noise limited” (61.4% passive resistors), while the ADA4938 is “IC noise limited” (71.6% internal noise). The ADA4930 yields SNR = 65 dB and ENOB = 10.6 bits, outperforming the ADA4938 (62 dB, 10.0 bits). The ADA4930 is therefore the optimal driver for maximizing slope to noise ratio and minimizing timing jitter.

Acknowledgment

The authors thank the TUBITAK BILGEM Embedded Systems and Digital Design Team and the NOVO Project Team for their technical support and collaboration throughout this work.

Keywords: Analog front-end, noise analysis, proton therapy, scintillating fibers, slew rate.
15:00 Poster panel: 91

Poster Number:
NSS-01-091

Radiation qualification of the interface Daughterboard for the ATLAS Tile Calorimeter Upgrade (#1565)

E. Valdes Santurio1, 2

1 Stockholm University, Physics Department, Stockholm, Sweden
2 CERN, ATLAS Collaboration, Meyrin, Genève, Switzerland

On Behalf of behalf of the ATLAS Tile Calorimeter system

Abstract

The upgrade of the ATLAS Tile Calorimeter readout system for the High Luminosity Large Hadron Collider requires radiation tolerant high throughput electronics capable of reliable long term operation under extreme radiation conditions. This work presents radiation qualification results of the Daughterboard, which interfaces on-detector electronics with off-detector trigger and data acquisition systems. Single point failures are minimized by means of two fully redundant halves, each integrating a CERN radiation tolerant GBTx ASIC for clock and configuration distribution, together with a Kintex Ultrascale FPGA for front-end control and data transmission via SFP+ modules. Radiation qualification targets require tolerance up to 32.71 Gy total ionizing dose, 4.38 × 10E12 n/cm2 non-ionizing energy loss, and 2.37 × 10E11 hadron/cm2 single event effects, including safety factors. Samples of Commercial off the shelf components were tested to evaluate batch variability. Results show all production components meet or exceed requirements. The MOSFETs exhibit degradation via a 15 mV threshold shift after 50 Gy, which does not affect the board functionality. Optical link single event upset error rates to about 9 errors/min over 3584 SFP+ modules, easily manageable by using forward error correction. While 0.65 functional errors/day are recoverable through targeted SFP+ module power cycle. Around 9.37 soft errors/min are expected over 1792 Kintex FPGAs, from which less than 0.20% (1.12 errors/hour) will require targeted FPGA reconfiguration. Radiation effects are mitigated using redundancy strategies and FPGA based soft error mitigation, reducing system impact to negligible levels. The results show that a hybrid architecture combining radiation tolerant ASICs with qualified commercial components enables a robust high bandwidth readout system for sustained operation withing the radiation conditions specified.

AcknowledgmentFysikum Stockholm University Physics Department
CERN ATLAS Collaboration
References
[1] ATLAS Collaboration, “Technical Design Report for the Phase-II Upgrade of the ATLAS Tile Calorimeter,” CERN-LHCC-2017-019, ATLAS-TDR-028, 2018.
[2] E. Valdes Santurio, “Development of the read-out link and control board for the ATLAS Tile Calorimeter Upgrade,” PhD dissertation, Department of Physics, Stockholm University, Stockholm, Sweden, 2019. DiVA: diva2:1364842
[3] GBTX Manual. Available: https://espace.cern.ch/GBT-Project/GBTX/Manuals/gbtxManual.pdf
[4] C. Amelung and H. Chen, “ATLAS Radiation Tolerant Electronics Proposed Guideline on COTS Lot-to-Lot Variation,” 2020. Available: https://indico.cern.ch/event/946481/contributions/3978191/attachments/2087789/3507703/COTSL2L.20200806.v2.pdf
[5] ATLAS Collaboration, “Radiation Environment of ATLAS.” Available: https://twiki.cern.ch/twiki/pub/Atlas/RadiationMapsGeant4/WebRadMapsZoomR2public.html
Keywords: Radiation Tolerant, TID, NIEL, SEU, SEL
15:00 Poster panel: 93

Poster Number:
NSS-01-093

Design of the new Matterhorn detector for the 4th generation synchrotrons (#1694)

D. Mezza1, M. Anastasi1, A. Bergamaschi1, M. Brueckner1, R. Dinapoli1, M. Carulla1, S. Ebner1, S. Emiliani1, K. Ferjaoui1, V. Gautam1, D. Greiffenberg1, E. Froejdh1, S. Hasanaj1, V. Hinger1, M. Huerst1, V. Kedych1, T. King1, S. Li1, C. Lopez-Cuenca1, L. Lunin1, A. Mazzoleni1, S. Moses1, K. Moustakas1, A. Mozzanica1, J. Mulvey1, M. Mueller1, C. Ruder1, B. Schmitt1, S. Silletta1, D. Thattil1, X. Xie1, J. Zhang1

1 Paul Scherrer Institute (PSI), SLS Detector Group, Villigen, Aargau, Switzerland

Abstract

The new fourth-generation storage rings (diffraction-limited storage rings), such as those at MAX IV Laboratory, ESRF EBS, and Swiss Light Source 2.0, will provide significantly higher brilliance than third-generation sources, resulting in a much larger photon flux at the pixel level. This increased flux will exceed the count-rate capabilities of many single-photon counting detectors currently in use, making them unsuitable for future experiments at these facilities. Matterhorn is a 2-D hybrid pixel detector developed by the PSD detector group at the Paul Scherrer Institute for operation at SLS 2.0. Its main objective is to extend the count rate capability to a target of 20 Mcounts/pixel/s using multi-threshold circuitry implemented in each pixel. The Matterhorn ASIC features a 256 × 256 pixel matrix with 75 μm pitch and is implemented in UMC 110 nm technology. Each pixel includes a charge-sensitive amplifier and a shaper connected to four comparators with independently adjustable thresholds. Setting thresholds above the photon energy enables an extension of the effective count-rate capability. Each comparator is connected to an independently gateable 16-bit counter. The target frame rate for reading out one 16-bit counter per pixel is 10 kHz. To support this rate, the ASIC periphery includes four serial links operating in double data rate mode at up to 3.125 GHz, driven by a 1.5625 GHz clock generated by an on-chip PLL. A fully synthesized digital periphery provides flexible ASIC configuration. Since January 2026, the final ASIC, which is fully functional, has been under test to evaluate its performance. This contribution focuses primarily on the ASIC design and detector architecture, and reports the main performance parameters measured so far, while a detailed discussion of the full characterization results will be presented in a separate contribution.

Keywords: ASIC Design, Single-photon counting, X-ray detectors, Synchrotron Detectors
15:00 Poster panel: 95

Poster Number:
NSS-01-095

A Low-Latency 28-nm CMOS ASIC for Superconducting Quantum Readout (#1815)

Y. Zhang1, C. Guo2, X. Wang2, W. Peng2, F. Liang2

1 University of Science and Technology of China, school of physical science, hefei, China
2 University of Science and Technology of China, Hefei National Laboratory,, hefei, China

Abstract

As the scale of the superconducting quantum control system continues to expand, traditional field-programmable gate array architectures face bottlenecks such as high energy consumption, low scalability, and severe signal attenuation. This paper proposes a highly integrated, low-latency digital front-end architecture fabricated in a 28-nm CMOS process to meet dynamic feedback requirements and optimize power, performance,and area. The front-end includes an arbitrary waveform generator and a data acquisition module, independently managed by a microcontroller. At the transmitter, a digital-to-analog converter
is used to output analog signals, with a measured spurious free dynamic range of 52 dB. At the receiver, a low-latency analog-to-digital converter captures analog signals, which the data acquisition module demodulates and ultimately uploads via a low-voltage differential signaling interface. The total hardware latency is restricted to approximately 100 ns. Under full-load testing conditions—including continuous waveform generation,concurrent demodulation of 16 qubits, and state feedback—the total digital power consumption is limited to 539 mW(33.7 mW/qubit). This design achieves extremely low latency and excellent energy efficiency, satisfying the real-time control demands of scalable fault-tolerant quantum computers.

References
[1] F. Arute et al., “Quantum supremacy using a programmable superconducting processor,” Nature, vol. 574, no. 7779, pp. 505–510, Oct. 2019.
[2] J. P. G. van Dijk et al., “Impact of Classical Control Electronics on Qubit Fidelity,” Physical Review Applied, vol. 12, no. 4, p. 044054, Oct. 2019.
[3] J. C. Bardin et al., “Design and Characterization of a 28-nm Cryo-CMOS Core for Control of Transmon Qubits,” IEEE Journal of Solid-State Circuits, vol. 54, no. 11, pp. 3043–3060, Nov. 2019.
[4] C. A. Ryan et al., “Hardware for dynamic quantum operations,” Physical Review A, vol. 95, no. 6, p. 062317, Jun. 2017.
Keywords: superconducting quantum computing, readout electronics, 28-nm CMOS ASIC, low latency
15:00 Poster panel: 97

Poster Number:
NSS-01-097

Radiation Effects on COTS On-Board Computer and Boot/Data-Storage Media Configurations for Super-Low-Earth-Orbit Optical Satellites (#1893)

J. Sohn1, 2, H. Lee1, 2, H. Yoon3

1 Korea Astronomy and Space Science Institute, Division of Space Exploration, Daejeon, Republic of Korea
2 University of Science and Technology, Department of Astronomy and Space Science, Daejeon, Republic of Korea
3 Korea Advanced Institute of Science and Technology, Department of Aerospace Engineering, Daejeon, Republic of Korea

Abstract

Super-low-Earth-orbit (SLEO) optical satellites require compact on-board computing and data-storage electronics, but commercial off-the-shelf (COTS) on-board computers (OBCs) and boot/data-storage media must retain boot, communication, and read/write functions under the mission radiation environment. This paper reports a configuration-level radiation screening of COTS OBC candidates for a 300 km-class, 2-year SLEO optical satellite. A SPENVIS/SHIELDOSE-2 dose assessment gave a total ionizing dose of 14.345 krad(Si) for the design case; therefore, a conservative 30 krad(Si) TID screening target was selected by applying a margin factor of approximately 2. The screening campaign included Arduino and Raspberry Pi family boards, and the detailed design interpretation focused on Raspberry Pi Compute Module 4 (CM4) with input/output board and nonvolatile boot/data-storage media, including Secure Digital (SD) cards, embedded MultiMediaCard (eMMC), solid-state drives (SSDs), and hard disk drives (HDDs). Devices were irradiated with cobalt-60 gamma rays, 10 MeV electrons, and 100 MeV protons, and were evaluated by boot status, communication, supply-current and voltage behavior, read/write operation, and recovery after irradiation. The results indicate that CM4-based configurations were more suitable than the other screened modules for the SLEO OBC candidate. Among storage options, eMMC showed the most favorable radiation and operational suitability, SSDs were identified as a practical secondary storage option after configuration-level verification, and HDDs were not recommended for spacecraft on-board use although some configurations survived to approximately 30 krad(Si), because rotating mechanical parts can affect spacecraft operation. These results support qualifying the exact OBC and boot/data-storage configuration, rather than only the processor board, for COTS-based SLEO on-board computing and storage electronics.

References
[1] Heynderickx, D, Quaghebeur, B, Wera, J, Daly, EJ, Evans, HDR 2004, ‘New radiation environment and effects models in the European Space Agency’s Space Environment Information System (SPENVIS)’, Space Weather, vol. 2, no. 10, S10S03, doi:10.1029/2004SW000073.
[2] Seltzer, SM 1994, ‘Updated calculations for routine space-shielding radiation dose estimates: SHIELDOSE-2’, NIST Interagency/Internal Report 5477, Gaithersburg, MD: National Institute of Standards and Technology.
[3] Raspberry Pi Ltd. 2026, ‘Raspberry Pi Compute Module 4 Datasheet’, Product Datasheet, Cambridge, United Kingdom: Raspberry Pi Ltd.
[4] European Space Components Coordination 2016, ‘Total Dose Steady-State Irradiation Test Method’, ESCC Basic Specification No. 22900, Issue 5, Noordwijk, The Netherlands: European Space Agency.
[5] U.S. Department of Defense 2013, ‘Method 1019.9: Ionizing Radiation (Total Dose) Test Procedure’, MIL-STD-883J, Test Method Standard Microcircuits, Washington, DC: U.S. Department of Defense.
[6] NASA Tech Briefs 2010, ‘Solid-State Recorders Enhance Scientific Data Collection’, NASA Tech Briefs, December 2010, Washington, DC: National Aeronautics and Space Administration.
[7] Fleetwood, DM 2013, ‘Total ionizing dose effects in MOS and low-dose-rate-sensitive linear-bipolar devices’, IEEE Transactions on Nuclear Science, vol. 60, no. 3, pp. 1706–1730, doi:10.1109/TNS.2013.2259260.
Keywords: COTS electronics, digital circuits, on-board computer, radiation effects, storage media
15:00 Poster panel: 99

Poster Number:
NSS-01-099

A Versatile High Linearity Front-End Preamplifier with Wide Dynamic Range for Multiple SiPM Sensors (#1920)

J. García-Barrena1, V. Herrero1, C. Mourani2, R. Esteve1, J. F. Toledo1, F. J. Mora1, F. Ballester1, V. Álvarez1, J. J. Gómez-Cadenas2

1 Universitat Politècnica de València (UPV), Instituto de Instrumentación de Imagen Molecular (I3M), Valencia, Spain
2 Donosti International Physics Center (DIPC), San Sebastián, Spain

On behalf of NEXT collaboration

Abstract

The integration of Silicon Photomultipliers (SiPMs) into high-resolution radiation detection systems has become increasingly relevant in the search for novel methodologies in precision energy measurement. This fact implies the need of front-end electronics capable of properly working with these sensors, whose parasitics change among different parts. In the signal processing chain, the initial stage must offer maximal linearity to preserve signal integrity throughout the subsequent architectures. A low-noise goal is also important in order to optimize energy resolution since first stage is critical in noise budget. Consequently, a specialized preamplifier design is presented in this paper in order to address these requirements. The primary design challenge involves achieving a very good linearity through high internal loop gain without compromising system stability. To ensure a controlled frequency response, the circuit employs a Miller compensation scheme whose dominant pole is inside the circuit. Constructing a robust stability topology, the architecture can handle diverse parasitic components in its input due to the use of different SiPM devices. In a first amplification stage, a key innovative structure has been developed as a translinear wideband inner gain stage. Furthermore, to ensure an extended dynamic range which allows working in both photon counting and high amplitude signal conditions without design reconfiguration, a digitally controlled attenuator system is integrated at the output of the first stage. The attenuator uses a R-2R ladder architecture implemented with MOSFET technology, allowing for direct gain adjustments and accurate calibration through external control logic.

AcknowledgmentThis work was supported by the Agencia Española de Investigación (AEI) through project PID2024-161553NB-C53. The authors gratefully acknowledge this funding, which enabled the research presented in this study.
References
[1] T. Contreras, B. Palmeiro, H. Almazán et al., “Measurement of energy resolution with the next-white silicon photomultipliers,” Journal of High Energy Physics, vol. 2024, no. 9, p. 112, 2024.
[2] C. Adloff et al., “Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques,” Journal of Instrumentation, vol. 7, no. 09, p. P09017, 2012.
[3] F. Corsi et al., “Modelling a silicon photomultiplier (sipm) as a signal source for optimum front-end design,” Nuclear Instruments and Methods in Physics Research Section A, vol. 572, no. 1, pp. 416–418, 2007.
[4] F. Corsi, M. Foresta, C. Marzocca, G. Matarrese, and A. Del Guerra, “Basic: An 8-channel front-end asic for silicon photomultiplier detectors,” Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE, pp. 1082 –1087, 24 2009-nov. 1 2009.
[5] W. Cheng, F. Cossio, M. D. R. Rolo, A. Rivetti, and Z. Wang, “A mixed-signal large dynamic range front-end asic for high capacitance detectors,” Journal of Instrumentation, vol. 14, no. 08, p. P08013, aug 2019. [Online]. Available: https://doi.org/10.1088/1748-0221/14/08/P08013
[6] R. J. Wiegerink, Analysis and Synthesis of MOS Translinear Circuits, ser. The Kluwer International Series in Engineering and Computer Science. Dordrecht, The Netherlands: Kluwer Academic Publishers, 1993, vol. 232.
[7] K. Bult and G. Geelen, “An inherently linear and compact most-only current-division technique,” Solid-State Circuits Conference, 1992. Digest of Technical Papers. 39th ISSCC, 1992 IEEE International, pp. 198–199, 281, Feb 1992.
Keywords: Preamplifier, High-Linearity, SiPM, Analog-Circuit
15:00 Poster panel: 101

Poster Number:
NSS-01-101

SPAGHETTI : An original instrument for the continuous gamma-ray based monitoring of hydrothermal volcanoes (#2092)

H. Chanal1, C. Achard1, J. Bonnard1, V. Breton1, E. Busato1, C. Insa1, J. Lao1, G. Magaud1, H. Croizet1, M. Magne1, V. Niess1, D. Picard1, V. Rabant1, L. Terray1

1 Université Clermont Auvergne, CNRS/IN2P3, LPCA, Clermont-Ferrand, France

Abstract

Hydrothermal volcanic systems are associated with major hazards such as magmatic/phreatic eruptions and toxic gaz emissions.
Monitoring fluid circulation within these systems is a key scientific challenge. 
The SPAGHETTI project (Spectral Panoptic Analyzers of Gamma rays in Hydrothermal Environments for Transport Time Inference) aims to develop
an original instrument dedicated to the continuous and high-frequency monitoring of radon using gamma-ray spectroscopy. 
The instrument relies on NaI scintillation detectors coupled to a specific signal processing electronics. 
The whole system is designed to withstand high temperatures, extreme humidity, and acidic corrosion. 
This contribution focuses on the FPGA-based digital signal processing chain implemented on a low-cost ADC-SoC platform. 
Real-time triggering, digital filtering, and amplitude extraction are performed directly in programmable logic. 
First tests aiming to demonstrate the capability of the system to continuously
acquire and process scintillation signals in conditions representative of volcanic hydrothermal environments will be presented.

Keywords: Volcano monitoring, radon, gamma-ray spectroscopy, digital signal processing, FPGA
15:00 Poster panel: 103

Poster Number:
NSS-01-103

Evaluating AMD's Versal Architecture for Tapped Delay Line Time-to-Digital Converters. (#2179)

J. Rossignol1, S.I. Kwon1

1 University of California, Davis, Biomedical engineering, Davis, California, United States of America

Abstract

Performances of tapped delay line (TDL) time-to-digital converters (TDCs) in FPGAs are strongly linked to the FPGA fabrication process, with newer fabrication processes usually yielding smaller propagation delays, thus improving the resolution and precision of the fine measurement. This study evaluates TDLs designed inside the Versal architecture, AMD's newest architecture that uses a 7 nm fabrication process. Since the Versal architecture's new configurable logic blocks (CLB) allow for multiple propagation paths through them, three different implementations of a TDL were evaluated. Code density and single-shot precision measurements were performed on five pairs of channels for each implementation. The lowest quantization error, 4.47 ps, was obtained using a mix of the outputs of the carry propagation circuit and the look-up tables (LUTs) of the CLB, while the best single-shot precision, 7.51 ps, was obtained by using only the output of the LUTs. Because of the change in the CLB design, TDL TDCs perform significantly worse than in AMD's previous architecture.

AcknowledgmentThis work was supported by the National Institutes of Health under grant R01 EB033536.
References
[1] H. Xia et al., A Review of Advancements and Trends in Time-to-Digital Converters Based on FPGA. IEEE T. Instrum. Meas. Vol. 73,  June 2024.
[2] J. Rossignol et al., Simulating and Optimizing Tapped Delay Lines for Time-to-Digital Converters in FPGA using a Precision Model based on Circuit Characteristics. SSRN, Oct. 2025.
[3] J. Rossignol et al., Tapped Delay Lines Time-to-Digital Converter Design and Performance in Versal Architectur. IEEE Real-Time Conference, 2026.
[4] Q. Wingering et al., FPGA Based Time-To-Digital Converter for Time of Flight Computed Tomography, IEEE NSS MIC RTSD, 2024.
Keywords: time-to-digital converter, Versal, tapped delay line, FPGA, digitizer
15:00 Poster panel: 105

Poster Number:
NSS-01-105

Probing Sub-20 ps Intrinsic Timing Limits of MVT-SiPM Readout for TOF-PET (#2205)

H. Lao1, Q. Xie1, G. Su3, Z. Wang4, J. Chen1, J. Wang4, H. Xu1, J. Yu2, L. Li2

1 University of Science and Technology of China, Department of Electronic Engineering and Information Science, hefei, China
2 Huazhong University of Science and Technology, Biomedical Engineering Department, Wuhan, China
3 University of Science and Technology of China, School of Gifted Young, hefei, China
4 University of Science and Technology of China, School of Microelectronics, hefei, China

Abstract

 The Multi-Voltage Threshold (MVT) method is widely employed in particle detection. However, limited by discrete hardware architectures, existing FPGA-based digitization systems struggle to fully exploit the fundamental timing potential of photodetectors. To investigate these performance limits, we systematically evaluate the ultimate timing performance of a detection chain comprising a CMOS SiPM and an in-house-developed MVT ASIC. This ASIC features picosecond time quantization and a wide dynamic range. Experimental results show that, under excitation from a synchronized picosecond laser source, the MVT ASIC achieves an intrinsic electronic time resolution of 16.94 ps (FWHM) and a coincidence time resolution (CTR) of 16.58 ps (FWHM). Benchmarking against a high-performance digital oscilloscope demonstrates that the timing precision of the MVT ASIC closely approaches that of laboratory-grade instrumentation (11.74 ps). This work validates the potential of the MVT ASIC for time-of-flight (TOF) measurement systems and establishes a promising technical foundation for ultra-high-resolution TOF detection.

AcknowledgmentThis work was supported in part by the National Key R\&D Program of China under Grant 2024YFE0113500, in part by the start-up fund of USTC "Research on total solid Angle PET-EPR multimodal intelligent imaging".
Hui Lao, Guanning Su, Jingbin Chen, Haoxuan Xu, Zereng Wang, Jing Wang (e-mail: jw2019@ustc.edu.cn) and Qingguo Xie (e-mail: qgxie@ustc.edu.cn) are with University of Science and Technology of China, Hefei, China.
Junhao Yu and Lu Li are with Biomedical Engineering Department,Huazhong University of Science and Technology, Wuhan,China.
References
[1] Xie, Q. , et al. "A New Approach for Pulse Processing in Positron Emission Tomography." IEEE Transactions on Nuclear Science 52.4(2005):988-995.
[2] Xi, Daoming , et al. "FPGA-Only MVT Digitizer for TOF PET." IEEE Transactions on Nuclear Science 60.5 Part1(2013):3253-3261.
Keywords: Multi-Voltage Threshold (MVT), Coincidence Time Resolution, Time-of-flight Measurement
15:00 Poster panel: 107

Poster Number:
NSS-01-107

Graphene-Based Front-End Amplifier for Nuclear Instrumentation (#2349)

M. Turqueti1, A. Lindman2, O. Aggarwal1, A. Poon2

1 Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, California, United States of America
2 Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, California, United States of America

Abstract

Front-end electronics for nuclear instrumentation require ultra-low noise, high bandwidth, radiation tolerance, and low power consumption to accurately process weak signals generated by radiation detectors. Conventional silicon-based amplifiers face increasing limitations in applications demanding extreme sensitivity, cryogenic operation, and compact integration. This work investigates the use of graphene-based electronic devices as a novel platform for next-generation front-end amplifiers for nuclear science applications. Owing to its exceptional carrier mobility, high thermal conductivity, mechanical flexibility, and potential for low-noise operation, graphene presents a promising alternative material for advanced detector readout electronics.

We present the conceptual design and preliminary evaluation of a graphene-based front-end amplifier architecture intended for integration with nuclear radiation detectors including silicon photomultipliers (SiPMs), cadmium zinc telluride (CZT) detectors, and other low-signal sensing systems. The proposed approach focuses on achieving improved signal amplification while minimizing electronic noise and power dissipation. Device-level considerations including transconductance behavior, impedance matching, frequency response, and low-temperature performance are analyzed to assess suitability for nuclear instrumentation environments.

Theoretical analyses indicate that graphene-enabled amplifier structures can provide enhanced sensitivity and bandwidth compared to conventional semiconductor implementations, particularly in low-temperature and low-signal regimes relevant to modern nuclear physics experiments and radiation detection systems. The results demonstrate the potential of graphene-based front-end electronics as an enabling technology for next-generation nuclear instrumentation, with applications spanning particle physics, medical imaging, homeland security, and advanced scientific sensing platforms.

References
[1] Butseraen, G., Ranadive, A., Aparicio, N. et al. A gate-tunable graphene Josephson parametric amplifier. Nat. Nanotechnol. 17, 1153–1158 (2022). https://doi.org/10.1038/s41565-022-01235-9
[2] Yuya Takatsuka; Kazuhiro Takahagi; Eiichi Sano; Victor Ryzhii; Taiichi Otsuji, "Gain enhancement in graphene terahertz amplifiers with resonant structures ",J. Appl. Phys. 112, 033103 (2012),https://doi.org/10.1063/1.4742998
[3] T. Hanna, N. Deltimple, M.S. Khenissa, E. Pallecchi, H. Happy, S. Frégonèse,"2.5GHz integrated graphene RF power amplifier on SiC substrate",Solid-State Electronics,Volume 127,2017,Pages 26-31,ISSN 0038-1101,https://doi.org/10.1016/j.sse.2016.10.002.
Keywords: GFET, Graphene, Charge Amplifier, CSA, Cryogenic
15:00 Poster panel: 109

Poster Number:
NSS-01-109

Design and characterization of a 28 nm CMOS asynchronous front-end for the readout of hybrid pixel sensors in future colliders (#2384)

L. Gaioni1, 3, L. Ratti2, 3, V. Re1, 3, G. Traversi1, 3, S. Gerardin4, D. Falchieri5, L. Frontini6, A. Stabile7

1 University of Bergamo, Dept. of Engineering and Applied Sciences, Bergamo, Italy
2 University of Pavia, Dept. of Electrical, Computer and Biomedical Engineering, Pavia, Italy
3 INFN - Istituto Nazionale di Fisica Nucleare, Sezione di Pavia, Pavia, Italy
4 University of Padova, Dept. of Information Engineering, Padova, Italy
5 INFN - Istituto Nazionale di Fisica Nucleare, Sezione di Bologna, Bologna, Italy
6 INFN - Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Milano, Italy
7 University of Milano, Dept. of Physics, Milano, Italy

Abstract

A demonstrator chip integrating a matrix of 32 x 8 readout channels for hybrid pixel detectors has been designed and tested in the framework of the PiHEX project, funded by the Italian Ministry of University and Research. The front-end channels include a low-noise charge sensitive amplifier with detector leakage compensation, an asynchronous, differential comparator, and a 5-bit threshold tuning DAC. A Time-over-Threshold counter is integrated for signal digitization. The front-end channels have been developed in a 28 nm CMOS technology and feature an overall area of 25 um x 100 um with a current consumption close to 4.2 uA. Full details on the design and characterization of the prototype chip will be reported in the conference paper.

Acknowledgment

This work was carried out in the framework of the PiHex project, CUP F53D23001490006 - PRIN 2022, funded by NextGenerationEU - M4, C2, 1.1.

References
[1] I. Peric, “The FEI3 Readout Chip for the ATLAS Pixel Detector”, Nucl. Instrum. and Methods, A 565 (2006), 178-187.
[2] H. C. Kastli et al., “Design and performance of the CMS pixel detector readout chip”, Nucl. Instrum. and Methods, A 565 (2006), 188-194.
[3] O. Aberle et al., “High-Luminosity Large Hadron Collider (HL-LHC): Technical design report”, CERN-2020-010 (2020).
[4] G. Alimonti et al., “RD53 pixel readout integrated circuits for ATLAS and CMS HL-LHC upgrades”. J. Instrum., 20 P03024 (2025).
[5] F. Resta et al., “28nm Integrated Circuit for PIXel detector”, Nucl. Instrum. and Methods, A 904 (2018), 140-148.
[6] F. Bandi et al., “Analog IP blocks in 28nm CMOS for the high energy physics community: SLVS transmitter and receiver”, J. Instrum., 18 C01039 (2023).
[7] S. Bonaldo et al., “Ionizing-radiation response and low frequency noise of 28-nm MOSFETs at ultrahigh doses”, IEEE Trans. Nucl. Sci., 67(2020), 1302-1311.
Keywords: 28 nm CMOS, low noise front-end, Time-over-Threshold digitization, hybrid pixel detectors
15:00 Poster panel: 111

Poster Number:
NSS-01-111

A 5.12-GS/s Time-Interleaved VCO-Based ADC With Digital Calibration for High-Speed Detector Waveform Digitization (#2436)

C. Chen1, Y. Hu1, S. Chen1, X. Hu1, J. Wang1

1 University of Science and Technology of China, Hefei, China

Abstract

This paper presents a 5.12-GS/s time-interleaved voltage-controlled-oscillator-based analog-to-digital converter (VCO-based ADC) for high-speed detector waveform digitization in nuclear science and high-energy physics experiments. The proposed ADC employs an 8-channel time-interleaved architecture, where each sub-channel operates at 640 MS/s, resulting in an aggregate sampling rate of 5.12 GS/s. VCO-based quantization is adopted to exploit time-domain signal processing and inherent first-order noise shaping. Each sub-channel integrates a high-linearity bootstrapped sampling switch, a 15-stage ring-VCO quantizer, multi-phase sampling flip-flops, and an asynchronous coarse counter to realize hybrid coarse-fine quantization. To address the major performance limitations of VCO-based and time-interleaved ADCs, a digital calibration scheme is introduced to compensate for the VCO voltage-to-frequency nonlinearity and inter-channel timing skew. The ADC is implemented in a 55-nm CMOS process. Post-layout simulation results show that, at an aggregate sampling rate of 5.12 GS/s with a 2.4-GHz input signal, the ADC achieves an SNDR of 37.5 dB and an effective number of bits of 5.94 bits after calibration. The simulated power consumption is 75 mW from a 1.2-V supply, corresponding to a Walden figure-of-merit of 239 fJ/conversion-step. Full-chip performance measurement is currently underway, and the measured results will be reported at the conference. These results demonstrate the potential of the proposed digitally calibrated TI VCO-based ADC for compact, high-speed detector readout systems.

References
[1] M. Wang et al., "Development of a High Counting Rate Waveform-Sampling Readout Electronics Based on DRS4 for TOF-PET Detector," in IEEE Transactions on Instrumentation and Measurement, vol. 74, pp. 1-9, 2025
[2] E. Delagnes et al., "The SAMPIC Waveform and Time to Digital Converter," 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Seattle, WA, USA, 2014
[3] J. Kim et al., "Analysis and Design of Voltage-Controlled Oscillator Based Analog-to-Digital Converter," in IEEE Transactions on Circuits and Systems I: Regular Papers, vol. 57, no. 1, pp. 18-30, Jan. 2010,
Keywords: TI-ADC, VCRO, 55-nm CMOS.
15:00 Poster panel: 113

Poster Number:
NSS-01-113

Development of an FPGA-based Hardware Data Injector for High-Energy Experiments (#2845)

M. M. Boonen1, D. Cieri1, O. Kortner1, S. Kortner1

1 Max Planck for Physics, Munich, Bavaria, Germany

Abstract

Most high-energy experiments at CERN are upgrad-
ing their trigger systems for the upcoming high-luminosity era of
the LHC. At the same time, development started on the trigger
systems of future collider experiments. To fully validate those
new systems and developments, it is necessary to test both the
algorithms and the underlying interfaces under consideration in a
faithful manner. For the former, simulations are used, and for the
latter small-scale hardware test stands are typically used. This
project proposes the usage of an FPGA-based hardware data
injector, which could replicate at the same time the expected fast
trigger data rate and transmission protocols. By storing Monte-
Carlo simulated data in a DDR4 memory and subsequently
transmitting it continuously to a trigger board under test using
Gigabit Transceivers, the emulator can mimic the expected low
latency data flow.

References
[1] CERN Yellow Reports: Monographs. CERN Yellow Reports: Mono-
graphs, Vol. 10 (2020): High-Luminosity Large Hadron Collider (HL-
LHC): Technical design report. 2020.
[2] Iacopo Longarini. “Status and testing of the MDT Trigger Processor for
the ATLAS Level-0 Muon Trigger at HL-LHC”. In: PoS EPS-HEP2025
(2026), p. 563. DOI: 10.22323/1.485.0563.
[3] Eric Shearer Hazen et al. “The APOLLO ATCA Platform”. In: Pro-
ceedings of Topical Workshop on Electronics for Particle Physics —
PoS(TWEPP2019). TWEPP2019. Sissa Medialab, Mar. 2020, p. 120.
DOI : 10.22323/1.370.0120. URL: http://dx.doi.org/10.22323/1.370.0120.
Keywords: Emulator, FPGA, Transceiver, Hardware, DDR
15:00 Poster panel: 115

Poster Number:
NSS-01-115

15:00 Poster panel: 117

Poster Number:
NSS-01-117

MU-STAR-mini: A 5-GS/s Prototype Sampling Array for High-Resolution Multi-Channel Streaming Readout (#3057)

L. Macchiarulo1, I. Mostafanezhad1, E. Forsythe1, J. Horikawa1, K. Hoe1, G. Uehara1, J. Cardenas1, C. Chock1

1 Nalu Scientific, LLC, Honolulu, Hawaii, United States of America

Abstract

In this article we describe the design and prototyping of the MUlti-channel Streaming Autonomous Readout chip (MU-STAR-mini) to explore the design limits of fast (5 Gsps) sampling array architectures for high voltage resolution, and probe the hypothesis that such architecture can be competitive in resolution and advantageous in terms of power, density and data reduction when compared with traditional ADC architectures for impulsive applications as they are often found in particle physics. We will describe the design and fabrication of the sampling array architecture, the design and fabrication of its test board, and its initial testing.

Acknowledgment

This work was partially funded under U.S. DOE DE-SC0025827 award.

References
[1] S. Ritt, "Design and performance of the 6 GHz waveform digitizing chip DRS4," 2008 IEEE NSS 2008 Dresden, Germany, 2008,
[2] L. Macchiarulo, et al., "Design improvements and first results for the revision 3 of AARDVARC Waveform Sampling System On Chip," IEEE NSS-MIC 2021, Virtual Presentation, October 2021.
[3] L. Macchiarulo et al. “HPSoCv3 - an integrated 9-channel 10 Gsps Waveform Digitizer for high density LGAD array”     2025 IEEE NSS, Yokohama, Japan, 2025
[4]  Luca Macchiarulo, et al, “Design and Measurement Results for the High Density Digitizer System on Chip (HDSoC): A 64 Channel 1 GSa/s Waveform Digitizer for High Density Detectors, ” IEEE NSS conference, October 2021.
Keywords: Data acquisition, high speed sampling, waveform digitization, high voltage resolution, streaming readout
15:00 Poster panel: 119

Poster Number:
NSS-01-119

Implementation of FPGA-Based Time-to-Digital Converters with Zero Measurement Dead Time (#1024)

X. Qi1, Y. Wang1

1 University of Science and Technology of China, Department of Modern Physics, Hefei, China

Abstract

Field programmable gate array (FPGA)-based time-to-digital converter (TDC) has played a very important role in facilities of high-energy physics and scientific instrumentation. Some applications even require TDCs without measurement dead time. In this paper, normal tapped delay line (TDL) based TDC structure is modified towards the realization of zero dead time without losing any TDC original performance. The major challenge in this situation is that there will be more than one signal transition edge in the latched TDL status, therefore, a robust multi-signal transition edge detection circuit module and calibration module are crucial. On a Xilinx UltraScale FPGA, the latched TDL status is first decomposed into 32 divisions, which execute the transition edge picking up parallel before they are combined together to give out all the edges. Since there is only one calibration table in the system, all the edges have to be calibrated sequentially through a specially designed data queue. For performance evaluation, the TDC prototype is implemented on the FPGA with a system clock frequency of 700 MHz. The TDC resolutions for the rising and falling edges are measured as 2.44 ps and 2.31 ps respectively, meanwhile the root-mean-square (RMS) time-interval measurement precisions are measured in the range of 3.5 to 6.5 ps. Applying two trigger signals with 500 ps separation into the TDC repeatedly, all the edges are captured and correctly measured, which demonstrates the capability of zero measurement dead time of the design.

References
[1] Y. Wang, X. Zhou, Z. Song, J. Kuang, and Q. Cao, “A 3.0-ps rms precision 277-MSamples/s throughput time-to-digital converter using multi-edge encoding scheme in a Kintex-7 FPGA,” IEEE Trans. Nucl. Sci., vol. 66, no. 10, pp. 2275–2281, Oct. 2019, doi: 10.1109/TNS.2019.2938571.
[2] X. Qi, J. Zhang, and Y. Wang, “Realization of zero measurement dead time on FPGA-based time-to-digital converters,” IEEE Trans. Instrum. Meas., vol. 74, pp. 1-8, Dec. 2024, Art no. 2001008, doi: 10.1109/TIM.2024.3509597.
Keywords: Field programmable gate array (FPGA), time-to-digital converter (TDC), tapped delay line (TDL), zero-dead-time TDC
15:00 Poster panel: 121

Poster Number:
NSS-01-121

A Pre-Study of a General-Purpose Trigger Processing Unit for the CEPC TDAQ System (#1197)

D. Liu1, 2, J. Zhao1, H. Wang1, 2, S. Dong1, B. Chen1, K. Zhu1, 2, W. Gong1, C. Li1, 2, F. Li1, X. Cao1, 2, Q. Zhao1, 2, Z. Liu1, 2

1 Institute of High Energy Physics, Beijing, China
2 University of Chinese Academy of Sciences, Beijing, China

Abstract

The Circular Electron Positron Collider (CEPC) is a large-scale international high-energy physics facility with the Higgs boson as its primary scientific goal. Three operation modes are foreseen: Higgs, Z, and W+W-. The CEPC Trigger and Data Acquisition (TDAQ) system faces a fundamental challenge: extracting rare physics events from an extremely high background rate. For example, in the Higgs mode, simulation results indicate that the target physics event rate is approximately 0.5 kHz, while the bunch crossing rate reaches 1.34 MHz. To cope with this challenge, the required Level-1 (L1) trigger rate for the Higgs mode is about 20 kHz.This extremely low signal-to-background ratio demands a trigger system capable of making efficient and real-time trigger decisions to achieve high-purity event selection while maintaining high efficiency for rare physics signals.To facilitate research and verification of the trigger system design, this talk presents a general-purpose Advanced Telecommunications Computing Architecture (ATCA) processing unit for the CEPC TDAQ system. The unit features an AMD Virtex UltraScale+ field-programmable gate array (FPGA) as its computing core, providing high-density parallel processing. High-speed data transmission is achieved via the FPGA's Gigabit Transceiver (GT) and optical transceivers, offering standardized interfaces for electronic subsystems. The design incorporates 11 Quad Small Form-factor Pluggable (QSFP) modules providing 44 high-speed lanes up to 25 Gbps each, 16 GB of Double Data Rate (DDR) memory for hundreds of milliseconds of buffering, and an Intelligent Platform Management Controller (IPMC) + K26 system-on-module (SOM) for intelligent management. Developed as a flexible testbed, this unit enables the implementation and evaluation of various trigger algorithms and architectures. The test results of related trigger functionalities and performance will be presented in the talk at the conference.

References
[1] S. P. Adhya et al. (CEPC Study Group), “CEPC Technical Design Report - Reference Detector,” arXiv:2510.05260 [hep-ex] (2025).
Keywords: CEPC, TDAQ, ATCA, FPGA, data processing.
15:00 Poster panel: 123

Poster Number:
NSS-01-123

Design of the Ultra-Low-Power Readout Electronics for the Large Area 3He Tube Array Detector at China Spallation Neutron Source (#1266)

W. Yin1, 2, Y. Lai1, 2, H. Liu1, 2, Q. Xiu1, 2, Y. Zhao1, 2

1 Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
2 Spallation Neutron Source Science Center, Dongguan, China

Abstract

The China Spallation Neutron Source (CSNS) is currently upgrading to CSNS-II, increasing the proton beam power to 500 kW and constructing several new neutron spectrometers. The CSNS-II upgrade poses significant challenges for detector and electronics systems, including higher counting rate, improved position resolution requirement, and vacuum operating environment. The large-area 3He tube array detector has been adopted as the major neutron detector owing to the high detection efficiency, the excellent neutron/gamma discrimination, and the ability to construct the detector with large area coverage. In this paper, we present an ultra-low-power front-end readout electronics designed for ³He tube detectors in CSNS-II spectrometers. The circuit design, FPGA algorithms, and laboratory test results of the electronics will be discussed. Experimental results demonstrate that the new electronics system can achieve a single-tube counting rate of 100K/s while maintaining a position resolution about 6 mm. Test also confirmed the system's capability to operate under vacuum conditions. These results meet the requirements for neutron signal readout in CSNS-II spectrometers.

Keywords: Readout electronics, 3He tube, CSNS II, Position resolution
15:00 Poster panel: 125

Poster Number:
NSS-01-125

A modular, self-triggered firmware for the FPGA-based readout of electromagnetic calorimeters at the INSIGHT@ELSA experiment (#1294)

B. Otto1

1 Bonn University, Helmholtz-Institut für Strahlen- und Kernphysik, Bonn, Germany

On behalf of the INSIGHT collaboration

Abstract

This paper presents a modular, per-channel self-triggered firmware architecture for the FPGA-based readout of electromagnetic calorimeters at the INSIGHT experiment. The firmware integrates a compact deconvolution stage to compensate preamplifier trailing-edge ringing, a configurable, pipelined feature extraction chain (baseline estimation, peak-based trigger with interpolation, pileup detection), and a lightweight network module. The implementation uses a decomposition of the deconvolution kernel to reduce resource usage. Despite the computational demands, the implementation of the deconvolution is resource-efficient and leaves headroom for further extensions. A Python-based simulation framework guided the selection and tuning of algorithms and numerical parameters. Test-beam measurements with a detector module showed an effective ringing suppression without affecting the pulse amplitude and timing; cooling the detector to the nominal operating temperature in upcoming runs is expected to further reduce residual artifacts. The resulting firmware framework provides a base for both electromagnetic calorimeters, the Crystal Barrel and the PANDA forward endcap calorimeter, in the INSIGHT experiment and will reduce maintenance effort.

Keywords: Feature extraction, Field programmable gate arrays, Sampling Analog-digital conversion
15:00 Poster panel: 127

Poster Number:
NSS-01-127

A Self-Triggered, Event-Driven Readout ASIC for the eXTP PFA X-ray Polarimeter (#1382)

N. Wang1, K. Wang1, Y. Zhang2, K. Wei2, Y. Shi2, M. Li3, T. Luo3, Z. Chen2, W. Lu2, Y. Cui2, W. Wei1, W. Jiang1, X. Liu1, H. Li1, H. Liu1, H. Liao1, H. Feng1

1 Institute of High Energy Physics,Chinese Academy of Sciences, Beijing, China
2 School of Integrated Circuits, Peking University, Beijing 100871, Peoples R China, Beijing, China
3 School of Software and Microelectronics, Peking University, Beijing 100871, Peoples R China, Beijing, China

Abstract

The Polarimetry Focusing Array (PFA) onboard the planned enhanced X-ray Timing and Polarimetry (eXTP) observatory comprises three identical X-ray imaging telescopes, providing X-ray polarimetry in the 2–8 keV energy range with high spatial, spectral, and temporal resolution. To meet these requirements, each detector unit integrates a radiation sensor with a dedicated Application-Specific Integrated Circuit (ASIC) for precise charge extraction and digitization of individual X-ray events.

 

This paper presents a readout ASIC designed for this application. The proposed ASIC features a self-triggering mechanism that enables event-driven readout with dynamically configurable windows. To satisfy stringent performance requirements, a two-stage analog readout architecture is adopted. Although the target system employs a 352 × 304 pixel array, a prototype ASIC with a 70 × 60 pixel matrix and a pitch of 50 μm was fabricated in a 180-nm CMOS process to validate the design.

 

Measurement results demonstrate an Equivalent Noise Charge (ENC) below 40 e⁻ rms. With a 12.5 MHz readout clock, the dead time for a typical event involving approximately 1000 pixels is maintained below 100 μs. These results verify the feasibility of the proposed ASIC architecture for the eXTP PFA instrument.

Keywords: eXTP, PFA, ASIC, X-ray polarimetry, low-noise readout
15:00 Poster panel: 129

Poster Number:
NSS-01-129

Pulse shape discrimination by digital pulse processing (#1608)

F. Liang1, N. Floyd1, H. Jayatissa1, P. Adsley2, A. Alvarez2, R. Bartsch2, S. Fritz2, T. Hankins2, B. Harvey2, K. Pham2, E. Schnorrenberg2, D. Shelden2, S. Yennello2

1 Los Alamos National Laboratory, ISR Division, Los Alamos, New Mexico, United States of America
2 Texas A&M University, Cyclotron Institute, College Station, Texas, United States of America

Abstract

Cerium doped gadolinium aluminium gallium garnet (GAGG:Ce) is capable of detecting both photons and charged particles. Particle identification capabilities present GAGG:Ce as a useful detector in nuclear physics research, and in medical, industry, security and space applications. This work explores the feasibility of using trapezoidal filtering for pulse shape discrimination (PSD) to perform particle identification so that the pulse height analysis (PHA) mode in commercially available waveform digitizers can be used without developing custom PSD firmware. Waveforms recorded from proton and alpha scattering measurements were analyzed offline to optimize the trapezoidal filter parameters. Satisfactory pulse shape discrimination was achieved with a figure of merit of 0.68. Future work will incorporate the optimized parameters in the waveform digitizers for heavy-ion reaction experiments to improve particle identification in real time.

AcknowledgmentLos Alamos National Laboratory is managed by Triad National Security, LLC for the U.S. Department of Energy's NNSA.
References
[1] Wuenschel, S, et al. 2009, 'NIMROD-ISIS, a versatile tool for studying the isotopic degree of freedom in heavy ion collisions', Nucl. Instrum. Methods, vol. A604, pp. 578-583.
[2] Sarantites, D, et al. 1996, 'The microball', Nucl. Instrum. Methods, vol. A381, pp. 418-432.
[3] HV, Richardson, IG, von Rosenvinge, TT 2010, 'A study of solar energetic particle events of 1997-2006: Their composition and associations', J. Geophys. Res., vol. 225, A014848.
[4] Rawat, S, et al. 2016, 'Pulse shape discrimination properties of Gd3Ga3Al2O12:Ce,B single crystal in comparison with CsI:Tl', Nucl. Instrum. Methods, vol. A840, pp. 186-191.
[5] Jordanov, VT, Knoll, GF, Huber, AC, Pantazis, JP 1994, 'Digital techniques for real-time pulse shaping in radiation measurements', Nucl. Instrum. Methods, vol. A533, pp. 261-264.
Keywords: inorganic scintillator, digital pulse processing, particle identification, pulse shape discrimination
15:00 Poster panel: 131

Poster Number:
NSS-01-131

Intrinsic time jitter of alternate data acquisition systems for the HISTARS project (#1947)

V. M. Nouvilas1, S. Gaitán1, L.M. Fraile2, 1, M. Caballero1, N. Bernier1, A. Illana3, 1, J.A. Briz1, J.M. Udías1

1 Universidad Complutense de Madrid, Grupo de Física Nuclear, Madrid, Spain
2 CERN, ISOLDE, Meyrin, Genève, Switzerland
3 CSIC, Instituto de Estructura de la Materia, Madrid, Spain

Abstract

The HIE-ISOLDE Timing Array for Reaction Studies (HISTARS) is being developed for the measurement of lifetimes of excited nuclear states produced in reactions at HIE-ISOLDE (CERN). It is based on fast particle and gamma scintillator  detectors that will require a fast data acquisition system capable of handling more than 60 channels with good time and energy resolution. Digitizing the fast scintillator signals will allow for a flexible signal processing, while preserving the pulse time structure, and potentially enabling high-precision timing.
In this work we measure the intrinsic time resolution of several digitizer systems for data acquisition and processing of data stemming from fast scintillators, such as LaBr$_3$(Ce). A very promising high-performance candidate is the CAEN 2751 digitizer, providing 14-bit, 1 GS/s, 16 channels, and embedded FPGA processing for advanced waveform acquisition and digital pulse processing. 
The DRS4 Evaluation Board uses the DRS4 switched-capacitor array chip developed at Paul Scherrer Institute with 4 input channels, sampling rates of 0.7 to 5 GS/s with 1024 sampling cells at 14-bit resolution. The CAEN DT5742B is a 16-channel switched-capacitor digitizer based on the same DRS4 chip, providing 14-bit resolution and up to 5 GS/s sampling rate.
The CAEN DT5751 is a desktop digitizer 4 channels, 10-bit resolution, and sampling rate of 1 GS/s per channel.
An in-house custom microcontroller-based data acquisition system, capable of analog pulse integration and timestamp assignment based on a bespoke time to amplitude converter (TAC), is also included in the DAQ systems comparison. These results will guide the choice of the data acquisition system for the HISTARS project and determine its baseline contribution to the timing capabilities of the array.

AcknowledgmentThis work was funded by the Spanish Government under grant PR38/23-HISTARS (MRR), and by the Comunidad de Madrid CT85/23 under grant PIPF-2023/SAL-GL-30761.
Keywords: Nuclear physics, Solid scintillation detectors, Nuclear electronics, Data acquisition
15:00 Poster panel: 133

Poster Number:
NSS-01-133

Feasibility Study of Analog Pulse Processing ASIC for SDD Array in High Count Rate XRF (#2211)

Y. Okubo1, D. Matsunaga1, C. Fiorini2, 3, G. Borghi2, 3

1 HORIBA, Ltd., Advanced R&D Center, Kyoto, Japan
2 Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milan, Italy
3 INFN, Sezione di Milano, Milan, Italy

Abstract

Silicon Drift Detectors (SDDs) are the most widely used sensors for energy dispersive X-ray detection in the energy range from a few hundred eV to some tens of keV. When connected to a state-of-the-art CMOS preamplifier, they provide high energy resolution at short peaking times, allowing for high count rates. In high-count-rate X-ray fluorescence (XRF) measurements, SDD arrays are also considered; however, using conventional Digital Pulse Processors (DPPs) requires a large number of ADCs and FPGAs, leading to an increase in overall system size. To keep the total system compact, this study proposes an approach using the analog pulse processing ASIC "SCARLET" and investigates its feasibility. Using an actual XRF setup, a single SDD signal was input into the ASIC as an initial evaluation of its fundamental throughput performance and energy spectrum at an input count rate of up to 1.8 Mcps. The results show that with a 400 ns shaping pulse width, the ASIC could potentially achieve faster throughput compared to a conventional DPP with an equivalent filter length. However, with a 200 ns pulse width, the throughput decreased, and incorrect energy measurements were observed, such as the appearance of an unexpected peak on the lower energy side. This indicates that there are remaining issues in the peak detection logic within the ASIC. This study provides fundamental insights into the effectiveness of the analog ASIC for high-count-rate XRF measurements and highlights areas for future improvement.

References
[1] R. Quaglia, et al., “Silicon Drift Detectors and CUBE preamplifiers for high-resolution X-ray spectroscopy “, IEEE Trans. Nucl. Sci., Vol. 62, No. 1, pp. 221-227, 2015
[2] G. Bellotti, et al. "The detection module of ARDESIA: A new, versatile array of SDDs for X-ray spectroscopy synchrotron applications",  Proc. IEEE NSS/MIC/RTSD, pp. 1-4, 2016
[3] I. Hafizh et al., “TERA: Throughput-Enhanced Readout ASIC for High-Rate Energy-Dispersive X-ray Detection,” IEEE Trans. Nucl. Sci., Vol. 67, No. 7, p. 1746, 2020
[4] G. Deda, et al., “SCARLET: Readout ASIC for Bump-bonded SDD Array for Large Event Throughput”, IEEE Trans. Nucl. Sci., Vol. 71, No. 10, pp. 2323-2333, 2024
Keywords: analog pulse processor, ASIC, high count rate, SDD array
15:00 Poster panel: 135

Poster Number:
NSS-01-135

High-performance upgrade for Track Lab: processing Timepix4 hits efficiently at scale (#2433)

P. Mánek1, B. Bergmann1, P. Burian1, 2, T. Čelko1, 3, R. E. Mihai1, 4, P. Smolyanskiy1

1 Czech Technical University in Prague, Institute of Experimental and Applied Physics, Prague, Czech Republic
2 University of West Bohemia in Pilsen, Faculty of Electrical Engineering, Pilsen, Czech Republic
3 Charles University, Department of Computer Science Education, Prague, Czech Republic
4 Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering, Department of Nuclear Physics, Bucharest-Magurele, Romania

Abstract

Timepix4 represents a significant advancement in the Timepix family of hybrid active pixel detectors, particularly attractive due to its fine time resolution (195 ps) and high supported hit rates (up to 5 GHz/mm2). To address performance challenges presented by these new features, an upgrade has been implemented for the Track Lab software package, which has become a standard tool for data collection and analysis of many
Timepix-based systems. Above all, the presented upgrade adds support for a 40 Gb/s PCI-express readout interface, capable of reaching hit rates of 300–400 MHz. To facilitate efficient analysis of such data volumes, the presented work implements a number of optimizations, including memory-level bit packing, deduplication and GPU offload for hit clustering, a required step for most event-based analysis algorithms. This work will
present details of these improvements, characterize Track Lab’s response under heavy load and present results of a performance benchmark. The upgraded software is expected to find plentiful applications in high-intensity X-ray imaging, γ-imaging and the forthcoming high-luminosity campaign at the Large Hadron Collider.

AcknowledgmentB.B. and P.M. and P.S. acknowledge funding from the Czech Science Foundation under Registration Number GM23-04869M. P.B. acknowledges funding from the Technology Agency of the Czech Republic under grant number TN02000012.
References
[1] P. Mánek, P. Burian, E. David-Bosne, P. Smolyanskiy, and B. Bergmann, “Track Lab: extensible data acquisition software for fast pixel detectors,
online analysis and automation,” J. Instrum., vol. 19, Jan. 2024, Art. no. C01008, 10.1088/1748-0221/19/01/C01008.
[2] X. Llopart et al., “Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp bin-
ning,” J. Instrum., vol. 17, Jan. 2022, Art. no. C01044, 10.1088/1748-0221/17/01/C01044.
[3] O.Růžička et al., “Timepix4 chipboard and readout concept,” J. Instrum., vol. 20, Jun. 2025, Art. no. C06074, 10.1088/1748-0221/20/06/C06074.
[4] T. Čelko, F. Mráz, B. Bergmann, and P. Mánek, “Parallel CPU- and GPU-based connected component algorithms for event building for hybrid pixel detectors,” J. Instrum., vol. 20, Jan. 2025, Art. no. C01041, 10.1088/1748-0221/20/01/C01041.
Keywords: GPU offload, high-performance computing, Timepix4, parallel processing, PCI-express
15:00 Poster panel: 137

Poster Number:
NSS-01-137

A Scalable High-Throughput DAQ Architecture for Real-Time Proton Beam Monitoring Applications (#2452)

B. Yerli1, U. Demir1, H. O. Caliskan1, B. Deniz1, F. Caliskan1, M. Ayyildiz1, K. Nurdan1, 2, B. Akgun2, 3

1 TÜBİTAK, Informatics and Information Security Research Center (BİLGEM), Kocaeli, Turkey
2 Bogazici University, Department of Physics, İstanbul, Turkey
3 Bogazici University, Center for Targeted Therapy Technologies, İstanbul, Turkey

On Behalf of NOVO Collaboration

Abstract

This paper presents a scalable and high-throughput data acquisition (DAQ) architecture developed for real-time proton beam monitoring applications in advanced proton therapy systems. The proposed system is designed to support detector-based tracking of proton energy deposition, enabling continuous monitoring of beam delivery and allowing treatment parameters to be adjusted dynamically during operation. By providing precise localization of proton energy release within the target region, the system contributes to improved dose accuracy while minimizing radiation exposure to surrounding healthy tissue. The DAQ architecture integrates high-speed digitization, synchronized timing distribution, and efficient event aggregation within a modular rack-based platform optimized for detector readout applications. The system consists of eight digitizer boards supporting 64 analog input channels corresponding to 32 detector elements. Differential signal readout is employed to improve signal integrity and reduce noise susceptibility during acquisition. A dedicated Data Collection Board equipped with 40 Gbps QSFP+ communication links aggregates and transfers acquired event data to a host DAQ server with high bandwidth and low latency. System-wide synchronization is maintained through a centralized Clock Distribution Board, while an OpenVPX-compliant Power Supply Board ensures reliable operation of all modules. The proposed architecture provides a compact, scalable, and synchronized solution for real-time proton therapy monitoring and high-performance medical imaging applications.

AcknowledgmentThe authors would like to acknowledge the support of The Scientific and Technological Research Council of Türkiye (TÜBİTAK). This work was carried out within the framework of the NOVO Collaboration, whose support and collaborative environment are gratefully appreciated.
References
[1] Bortfeld, Thomas, and Wolfgang Schlegel. "An analytical approximation of depth-dose distributions for therapeutic proton beams." Physics in Medicine & Biology 41.8 (1996): 1331-1339.
[2] Medina, Elisabetta. "Solid-state detectors for beam monitoring in FLASH radiotherapy and for other harsh environment applications." (2025).
[3] Halfon, Orith, et al. "A position sensitive detector with real-time gamma/neutron discrimination capability." IEEE Transactions on Nuclear Science (2025).
[4] Halfon, O., et al. "First Experimental Measurement of Prompt Gamma Imaging with Real-Time Neutron Rejection via Pulse Shape Discrimination." IEEE Transactions on Radiation and Plasma Medical Sciences (2026).
[5] Matamoros, A., et al. "Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector." Physics in Medicine & Biology 70.16 (2025): 165002.
[6] Liu, Zhengyao, et al. "Design of highly reliable and rugged PHYTIUM computing unit based on OpenVPX." International Conference on Internet of Things and Machine Learning (IoTML 2021). Vol. 12174. SPIE, 2022.
[7] Paganetti, Harald, et al. "Roadmap: proton therapy physics and biology." Physics in Medicine & Biology 66.5 (2021): 05RM01.
Keywords: Data acquisition (DAQ), proton therapy, OpenVPX, clock synchronization
15:00 Poster panel: 139

Poster Number:
NSS-01-139

A Modular High-Bandwidth DAQ System for the Medipix4 ASIC Based on FPGA Ethernet Readout (#2665)

N.V. Biesuz1, R. Ballabriga2, J. A. Alozy2, R. Bolzonella2, M. Campbell2, M. Fiorini3, 1, X. Llopart2

1 Istituto Nazionale di Fisica Nucleare (INFN), Ferrara Division, Ferrara, Italy
2 CERN, EP Department, Geneva, Switzerland
3 Università di Ferrara, Ferrara, Italy

Abstract

The Medipix4 ASIC is a hybrid pixel detector developed for high-rate spectroscopic X-ray imaging and photon-counting applications. Its synchronous frame-based architecture supports multiple acquisition modes and up to sixteen DDR output links, requiring scalable off-detector electronics. This work presents a modular FPGA-based Data Acquisition (DAQ) system developed for Medipix4 characterization and detector integration.
The system is composed of a Xilinx Kintex UltraScale FPGA DAQ board and a dedicated CERN-developed Medipix4 chipboard directly interfaced through FMC connectivity. The firmware reuses the IPbus-based control path developed for the Timepix4 ASIC while implementing a dedicated Medipix4 synchronous acquisition pipeline. Sixteen independent DDR interfaces operate at selectable clock frequencies of 20, 40, 80, 160 and 320 MHz. Each detector link is connected to a deserializer implementing frame detection, header decoding and 64-bit payload reconstruction. The decoded headers allow the firmware to determine the active acquisition configuration, including counter depth, active links and payload size.
The sixteen parallel data streams are packetized and transmitted through two independent 10~Gigabit Ethernet UDP links. The aggregate detector bandwidth of 10.24 Gb/s is compatible with the measured sustained transmission throughput of 2 X 8.85 Gb/s. The firmware uses reusable open-source HDL components where possible and is distributed within the Medipix collaboration as Open Hardware under the CERN Open Hardware Licence. Ongoing developments include migration toward lower-cost FPGA platforms and support for simultaneous acquisition from multiple Medipix4 ASICs.

References
[1] Sriskaran, V.,  Alozy, J., Ballabriga, R., Campbell, M., Christodoulou, P., Heijne, E., Koukab, A. Kugathasan, T., Llopart, X., Piller, M., Pulli, A., Sallese, J.-M., Tlustos, L. 2024, ‘High-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities’, Journal of Instrumentation, 19 (02) P02024 , online: IOP Publishing
[2] Llopart, X., Alozy, J., Ballabriga, R., Campbell, M., Casanova, R., Gromov, V., Heijne, E.H.M., Poikela, T., Santin, E., Sriskaran, V., Tlustos, L., Vitkovskiy, A.,  2022, ‘Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning’, Journal of Instrumentation, 17 (01), C01044, online: IOP Publishing
[3] C. Ghabrous Larrea, K. Harder, D. Newbold, D. Sankey, A. Rose, A. Thea and T. Williams, 2015, “IPbus: a flexible Ethernet-based control system for xTCA hardware”, Journal of Instrumentation 10 (02), C02019, online: IOP Publishing
[4] Biesuz, N.V., Caballero, R., Cieri, D., Giangiacomi, N., Gonnella, F., Loustau De Linares, G., Peck, A., 2023, `Hog 2023.1: a collaborative management tool to handle Git-based HDL repository', Proceedings of the 3rd Workshop on Open-Source Design Automation (OSDA), arXiv:2304.02437
[5] Forencich, A., Han, S., 2025, `verilog-ethernet: Ethernet MAC, PHY, and networking stack in Verilog', GitHub repository, [Online]: https://github.com/alexforencich/verilog-ethernet
[6] Bruendler, O., 2026, `Open-Logic: reusable open-source FPGA building blocks', GitHub repository. [Online], https://github.com/open-logic/open-logic
Keywords: Medipix4, FPGA, DAQ systems, pixel detectors, front-end electronics
15:00 Poster panel: 141

Poster Number:
NSS-01-141

Measurement of Energy-Dependent Neutron-Induced Single-Event-Upset Rates for Multiple FPGA Types (#2544)

S. Ueda1, H. Bae2, E. Hamada3, Y. Igarashi3, Y. Nakazawa3, S.-I. Meigo4, 5, H. Miyai1, K. Oishi3, K. Ueno1, C. Yamada1

1 The University of Osaka, Toyonaka, Japan
2 Tohoku University, Sendai, Japan
3 High Energy Accelerator Research Organization, Tukuba, Japan
4 Japan Atomic Energy Agency, Naka, Japan
5 J-PARC Center, Naka, Japan

Abstract

We measured energy-dependent single-event-upset (SEU) rates for three field-programmable gate array (FPGA) types under neutron irradiation at the BL10 beamline of the Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC). Two 28-nm complementary metal oxide semiconductor (CMOS) devices and one 65-nm CMOS device was irradiated with neutrons over a wide energy range from meV to MeV. Dedicated firmware detected SEUs with high timing precision, and the time-of-flight (TOF) method identified the neutron energies that caused the SEUs. We estimated the neutron fluence from a PHITS simulation of the beam spectrum and normalized the SEU counts to the fluence for each FPGA type.

The SEU rates clearly depended on neutron energy. 
One 28-nm device had an SEU rate in the 10-8-10-7 MeV region about one order of magnitude higher than that at 1 MeV, whereas the other devices showed no significant low-energy enhancement. Below 0.1 MeV, the SEU rate increased as neutron energy decreased, approximately following the 1/v dependence, where v is the neutron velocity.

The two 28-nm devices responded differently despite using the same process technology. In contrast, the 65-nm device had a low-to-high-energy change similar to that of one 28-nm device.
These results suggest that device structure or neutron-sensitive materials, rather than process technology alone, contribute to neutron-induced SEUs.

AcknowledgmentThe neutron experiment at the J-PARC MLF BL10 NOBORU was performed under a user program (Proposal No. 2025B0064). The
authors would like to express their sincere thanks to
Dr. K. Oikawa, Dr. M. Harada, and Dr. Y. Tsuchikawa at J-PARC for their support during this experiment.
This work was supported by the Japan Society for the Promotion of Science (JSPS) KAKENHI under Grant JP21H04971.
References
[1] Iwashita, H, Kiuchi, R, Hiroshima, Y,  ,Okugawa, Y, Sebe, T,  Takeda, M 2023, ‘Energy-Resolved SEU Cross Section From 10-meV to 800-MeV Neutrons by Time-of-Flight Measurement,’ in IEEE Transactions on Nuclear Science, vol. 70, no. 3, pp. 216-221
[2] Yamada, C, Bae, H, Hamada, E, Miyai, H, Nakazawa, Y, Oishi, K, Ueda, S, Ueno, K, 2026 “Thermal-neutron-induced single event upsets in an FPGA used in particle physics experiments,” Nucl. Instrument. Methods. Phys. Res. A, Vol. 1083, p. 171149.
[3] Hasemi, H, Harada, M, Kai, T, Shinohara, T, Ooi, M, Sato, H, Kino, K, Segawa, M, Kamiyama, T, Kiyanagi, Y, 2015 “Evaluation of nuclide density by neutron resonance transmission at the NOBORU instrument in J-PARC/MLF,” Nucl. Instrum. Methods Phys. Res. A, Vol. 773, pp. 1137–1149.
[4] Iwasem, H, Niita, K, Nakamura, T, 2002 “Development of general-purpose particle and heavy ion transport Monte Carlo code,” J. Nucl. Sci. Technol., Vol. 39, No. 11, pp. 1142–1151.
Keywords: Field-programmable gate arrays, Neutron beams, Radiation hardening, Single-event upsets
15:00 Poster panel: 143

Poster Number:
NSS-01-143

Wireless Dosimetry System for Interventional Radiology (#2676)

M. Moniz1, P. M.M. Correia1, A. L.M. Silva1, J. F.C.A. Veloso1, C. D.R. Azevedo1

1 University of Aveiro, i3N - Physics Department, Aveiro, Portugal

Abstract

This work presents the design and characterisation of the front-end eletronics of a wireless active personal dosimeter for interventional radiology. The device is a low-cost, single-channel sensing unit that can be replicated across the thorax, neck, hands, and eyes, providing operators with continuous dose-rate feedback at these four anatomical regions. Each dosimeter consists of a tissue-equivalent plastic scintillator coupled to a silicon photomultiplier, read out by a charge-sensitive amplifier, a semi-Gaussian shaper with pole-zero cancellation, and a peak-and-hold circuit triggered by a comparator. Power management and wireless transmission are handled by a battery-operated microcontroller, keeping the assembly compact and unobtrusive to the operator. Dose-rate data are transmitted to a remote display with visual and sound alarms. The front-end has been characterised under dark-count conditions, with a dead time of 11.6 microseconds expected to extend to approximately 20 microseconds once analog-to-digital conversion is included in the readout loop. Energy and dose calibration of the coupled detector, together with the four-channel graphical interface, are the next development steps.

AcknowledgmentThis work was supported in part by project CENTRO2030-FEDER-02363500 (easyPET.CT), funded by the FEDER program through CENTRO2030 and by national funds through FCT - Fundação para a Ciência e a Tecnologia, I.P., under the project UID/50025/2025 (doi.org/10.54499/UID/50025/2025), UID/PRR/50025/2025 (doi.org/10.54499/UID/PRR/50025/2025), UID/PRR2/50025/2025 (doi.org/10.54499/UID/PRR2/50025/2025) and the Associate Laboratory I3N -- LA/P/0037/2020 (doi.org/10.54499/LA/P/0037/2020).
References
[1] National Council on Radiation Protection and Measurements, ``NCRP Report No. 168: Radiation dose management for fluoroscopically guided interventional medical procedures,'' Bethesda, MD, USA, Tech. Rep., Jul. 2010.
[2] L. Servoli, L. Bissi, S. Fabiani, D. Magalotti, P. Placidi, A. Scorzoni, A. Calandra, R. Cicioni, S. Chiocchini, A. C. Dipilato, N. Forini, M. Paolucci, R. D. Lorenzo, F. P. Cappotto, M. Scarpignato, A. Maselli, and A. Pentiricci, “Personnel real time dosimetry in interventional radiology,” Physica Medica, vol. 32, pp. 1724–1730, 12 2016.
[3] R. Sanchez, E. Vano, J. M. Fernandez, and J. J. Gallego, “Staff radiation doses in a real-time display inside the angiography room,” CardioVascular and Interventional Radiology, vol. 33, pp. 1210–1214, 12 2010.
[4] R. Baumgartner, K. Libuit, D. Ren, O. Bakr, N. Singh, U. Kandemir, M. T. Marmor, and S. Morshed, “Reduction of radiation exposure from c-arm fluoroscopy during orthopaedic trauma operations with introduction of real-time dosimetry,” Journal of Orthopaedic Trauma, vol. 30, pp. 53–58, Feb. 2016
[5] V. Koch, L. M. Conrades, L. D. Gruenewald, K. Eichler, S. S. Martin, C. Booz, T. D’Angelo, I. Yel, S. Bernatz, S. Mahmoudi, M. H. Albrecht, J. E. Scholtz, A. Thalhammer, S. Zangos, T. J. Vogl, and T. Gruber-Rouh, “Reduction of radiation dose using real-time visual feedback dosimetry during angiographic interventions,” Journal of Applied Clinical Medical Physics, vol. 24, 2 2023.
[6] J. Racadio, R. Nachabe, B. Carelsen, J. Racadio, N. Hilvert, N. Johnson, K. Kukreja, and M. Patel, “Effect of real-time radiation dose feedback on pediatric interventional radiology staff radiation exposure,” Journal of Vascular and Interventional Radiology, vol. 25, pp. 119–126, 2014.
[7] James, R. F., Wainwright, K. J., Kanaan, H. A., Hudson, S., Wainwright, M. E., Hightower, J. H., & Delaney, J. J. (2015). Analysis of occupational radiation exposure during cerebral angiography utilizing a new real time radiation dose monitoring system. Journal of neurointerventional surgery, 7(7), 503–508. https://doi.org/10.1136/neurintsurg-2014-011215
[8] U. O’Connor, E. Carinou, I. Clairand, O. Ciraj-Bjelac, F. De Monte, J. Domienik-Andrzejewska, P. Ferrari, M. Ginjaume, H. Hrˇsak, O. Hupe, Z. Kneˇzevi´c, M. Sans Merce, S. Sarmento, T. Siiskonen, and F. Van- ˇ havere, “Recommendations for the use of active personal dosemeters (apds) in interventional workplaces in hospitals,” Physica Medica, vol. 87, pp. 131–135, 2021.
[9] Radiological protection---X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy---Part 1: Radiation characteristics and production methods}, ISO Standard 4037-1:2019, Jan. 2019.
Keywords: Active personal dosimeter, Interventional radiology, plastic scintillator, real-time monitoring, silicon photomultiplier
15:00 Poster panel: 145

Poster Number:
NSS-01-145

FPGA firmware for ³He resistive wire tube readout with CAEN R5560 ADC. (#2794)

D. Raspino1, A. Abba2, E. Schooneveld1, S. Carsi2, J. Sykora1

1 UKRI- STFC, ISIS, Chilton Didcot, United Kingdom
2 Nuclear Instrument, Comom, Italy

Abstract

This work presents the development of a versatile FPGA firmware for the readout of ³He resistive wire tubes widely used in neutron scattering instruments. These detectors are deployed in large numbers across major neutron facilities, including ISIS, ILL, SNS, FRM2, ESS, MLF, and CNCS.

In typical configurations, detector signals are first conditioned by front-end preamplifiers located near the tubes, then digitized by ADC systems positioned up to 40 m away. The FPGA-based processing extracts pulse amplitudes to determine the neutron interaction position along the detector. The implemented system is based on the R5560 ADC, operating at a sampling rate of 125 MHz.

The firmware, developed using SCI-Compiler, is organized into two main blocks: signal processing and data transmission. The signal processing stage includes baseline correction and gain scaling to maximize ADC dynamic range, followed by configurable filtering. The latter consists of cascaded moving-average integrators and a differentiator, with user-defined parameters (number and length of filters) adjustable via control registers to accommodate different instrument requirements.

To ensure compatibility with both legacy and next-generation data acquisition systems, the firmware supports multiple communication interfaces. At ISIS, the ADC serial interface is currently used for integration with the existing Data Acquisition Electronics (DAE), as demonstrated on the OSIRIS instrument. In parallel, a high-throughput UDP-based optical fibre link has been developed for future deployment, including WISH and μRWELL-based detector systems. Additionally, a TCP/IP Ethernet interface provides a flexible solution for diagnostics and lower-rate data acquisition.

This architecture enables a scalable and adaptable readout solution for current and future neutron detector systems.

References
[1] ISIS Annual Report, https://www.isis.stfc.ac.uk/wp-content/uploads/2025/10/ISIS_Annual_Report_2025_final.pdf
[2] CAEN R5560 ADC Family, https://www.caen.it/products/r5560/
[3] Visual Programming Language for Open FPGA, https://www.sci-compiler.com/
[4] M. T. F. Telling and K. H. Andersen , Phys. Chem. Chem. Phys., 2005, 7 , 1255 —1261, https://doi.org/10.1039/B413934H
[5] L. C. Chapon, P. Manuel, P. G. Radaelli, C. Benson, L. Perrott, S. Ansell, N. J. Rhodes, D. Raspino, D. Duxbury, E. Spill, J. Norris, Wish: The new powder and single crystal magnetic diffractometer on the second target station. Neutron News 22, 22–25 (2011).
[6] R. Hafeji,et al, Gain measurements of μRWELLs in 3He-CF4 mixtures for thermal neutron detectors, Nuclear Instruments and Methods in Physics Research Section A, Volume 1048, 2023, https://doi.org/10.1016/j.nima.2022.167976.
Keywords: ADC, FPGA, Signal Processing, Neutron Detectors
15:00 Poster panel: 147

Poster Number:
NSS-01-147

LDMX Silicon Tracker Data Acquisition System (#2807)

B. Reese1, T. K. Nelson1, M. Gignac1, C. Bakalis1

1 SLAC National Accelerator Laboratory, Menlo Park, California, United States of America

Abstract

The Light Dark Matter eXperiment (LDMX) is a proposed fixed-target experiment that will search for sub-GeV dark matter using a missing-momentum signature in high-rate electron interactions. Its Silicon Tagging Tracker (STT) and Silicon Recoil Tracker (SRT) measure incoming and outgoing charged particles around the target, providing trajectory and momentum information needed to identify events with invisible final-state particles and reject backgrounds. The Tracker data acquisition (DAQ) system is built around APV25-based silicon strip modules, front-end boards (FEBs), and a Bittware PCI Express back end integrated with the common LDMX timing, fast-control, and event-building infrastructure. Each FEB distributes APV25 clock, trigger, reset, I2C control, low-voltage power, and sensor bias. It also digitizes APV25 analog streams, formats three-sample channel records, and transmits Tracker event records to the back end. The architecture is constrained by the APV25 pipeline latency and must preserve bunch timing while scaling to the final multi-FEB Tracker. During the 2025 LDMX test at SLAC End Station A, a Tracker DAQ vertical slice operated one FEB with four silicon Hybrid modules and the Bittware back end. The system acquired coherent data with other LDMX subsystems, demonstrated stable noise performance, was timed in to beam, and observed beam-induced hits with the expected timing behavior.

Keywords: Data Acquisition, FPGA, ADC, Silicon Sensor
15:00 Poster panel: 149

Poster Number:
NSS-01-149

Latest Upgrades and Operation of the Neutron Veto Data Acquisition System for the XENONnT Experiment (#2929)

S. Mastroianni1

1 INFN, Sec. Naples, Naples, Italy

on behalf of the XENON Collaboration

Abstract

The Neutron Veto (NV) of the XENONnT experiment is a gadolinium-doped water Cherenkov
detector surrounding the central xenon time projection chamber (TPC). It is instrumented with 120
photomultiplier tubes (PMTs) to reduce the nuclear recoil background induced by radiogenic
neutrons originating from detector materials, which can mimic WIMP-like signatures.
During the third science run (SR2), conducted between October 2023 and March 2025, XENONnT
achieved a significantly reduced background configuration. In particular, the neutron background
was suppressed by loading the water tank with 500 ppm of gadolinium sulfate, resulting in an
approximately twofold reduction compared to earlier runs performed with pure water. Following
maintenance activities initiated in summer 2025, the detector is currently being recommissioned in
preparation for the next science run.
This work presents the latest upgrades and the operational performance of the NV data acquisition
(DAQ) and online processing systems. The NV DAQ is based on a fully triggerless architecture in
which PMT waveforms are continuously digitized, enabling software-based coincidence searches
within time windows of several hundred nanoseconds.
To enhance long-term reliability and stability, the DAQ system has been upgraded with new-
generation CAEN PCIe readout cards. Concurrently, the front-end server has been upgraded to
ensure compatibility with latest operating systems, while improving fault tolerance, system
monitoring, and integration with the experiment-wide online processing system.
A further improvement is the deployment of a dedicated FPGA-based monitoring board for the NV
data readout. This board processes digitizer monitoring signals such as buffer occupancy, busy and
flow-control flags, timing and synchronization signals, and error conditions during both science
data taking and calibration runs, enabling continuous checks of DAQ performance and stability.

Keywords: trigger-less, FPGA, Neutron Veto
15:00 Poster panel: 151

Poster Number:
NSS-01-151

Design and Integration of a Modular LiInP2Se6 Neutron Detector Prototype for Single-Crystal Diffractometry Applications (#3158)

M.E.A. Benkechkache1, 2, E. Hoegberg1, 2, A. Kargar3, J. Christian3, C. Sosa3, H. Hong3, M. Kanatzidis4, K. Saheb4, S. Imam4, E. Lukosi1

1 University of Tennessee, Nuclear Engineering Department, Knoxville, Tennessee, United States of America
2 UT Institute for Advanced Materials & Manufacturing, Knoxville, Tennessee, United States of America
3 Radiation Monitoring Devices, Inc., Watertown, Massachusetts, United States of America
4 Northwestern University, Department of Chemistry, Evanston, Illinois, United States of America

Abstract

Lithium Indium Phosphorus Selenide (LiInP2Se6) has emerged as a promising semiconductor material for neutron detection due to its high neutron capture cross-section, suitable bandgap, and favorable charge transport properties. This work reports on the development of a modular LiInP2Se6 detector prototype for single-crystal diffractometry (SCD) applications. The prototype consists of an 8 × 2 array of LiInP2Se6 strip sensors with a 300 μm pitch configuration integrated onto a custom sensor baseboard. Initial sensor characterization includes electrical IV measurements and preliminary radiation-response evaluation. The sensors are coupled to a dual-ASICs daughterboard based on VATAGP7 ASICs for signal readout and processing, while detector control and data acquisition are managed through the LISeDAQ acquisition system. This work demonstrates the integration of LiInP2Se6 sensors, front-end electronics, and acquisition hardware into a scalable detector module architecture toward future high-resolution SCD detector systems.

AcknowledgmentThis material is based upon work supported by the U.S. Department of Energy under grant no. DE-SC0021554. Disclaimer: The views and conclusions contained in this document are those of the authors and should not be interpreted as necessarily representing the official policies, either expressed or implied, of the U.S. Department of Energy.
References
[1] C.C. Wilson, ” Single-crystal neutron diffraction from molecular materials”. Vol. 2. World Scientific Publishing Company, 2000.
[2] Y. Liu, et al. ”PIONEER, a high-resolution single-crystal polarized neutron diffractometer.” Review of Scientific Instruments 93.7 (2022).
[3] C.L. Wang, et al. ”Bright Eu2+-activated polycrystalline ceramic neutron scintillators.” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 883 (2018): 1-8.
[4] D. Chica, et al., ”Direct thermal neutron detection by the 2D semiconductor 6LiInP2Se6”. Nature, 577(7790), (2020).
[5] M.A. Benkechkache, et al. ”Front-end Electronics of a LiInP2Se6 Neutron Detector for Single Crystal Diffractometer.” 2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conference (RTSD). IEEE, 2024.
[6] IDEAS, Inc. (Norway), http://ideas.no/.
Keywords: DSSD, LiInP2Se6, Readout electronics, SCD, VATAGP7 ASIC
15:00 Poster panel: 153

Poster Number:
NSS-01-153

Improvement of Ambient dose equivalent rate Estimation for Airborne Radiation Monitoring Using Artificial Neural Networks with Vegetation and Topographic Information (#1454)

A. Miyahara1, S. Miyuki1, K. Suzuki1, Y. Morishita1, H. Funaki1

1 Japan Atomic Energy Agency, 1. Collaborative Laboratories for Advanced Decommissioning Science, Minamisoma, Japan

Abstract

In airborne radiation monitoring using unmanned aerial vehicles conducted in Japan following the Fukushima Daiichi nuclear power plant accident, a flat-source model is used to estimate the ambient dose equivalent rate at ground level from count rates. However, its assumptions are not suitable for mountainous and forested areas. To improve reliability in these areas, an artificial neural network was constructed that incorporates topographic and vegetation information as input variables in addition to count rate information, and its impact on estimation performance was evaluated.

The ambient dose equivalent rate map generated by the artificial neural network model reproduced spatial variation in more detail compared to the map created by the flat-source model. Vegetation information helped distinguish between forests and open land, contributing to improved estimation accuracy and precision. Topographic information reduced errors in mountainous areas where the relative position of the detector and the ground changes drastically. An artificial neural network incorporating this information can contribute to identifying hotspots and determining whether evacuation orders can be lifted for small areas.

References
[1] Sasaki, M., Sanada, Y., Katengeza, E.W., Yamamoto, A., 2021, ‘New method for visualizing the dose rate distribution around the Fukushima Daiichi Nuclear Power Plant using artificial neural networks’, Scientific Reports, vol. 11, article 1857
[2] Sasaki, M. & Sanada, Y. 2022, ‘Improvement of training data for dose rate distribution using an artificial neural network’, Journal of Advanced Simulation in Science and Engineering, vol. 9, no. 1, pp. 30–39
[3] Sasaki, M., Ochi, K., Sanada, Y., Joung, S., Choi, Y., Lee, E., Ji, W. & Ji, Y.-Y. 2025, ‘Expanding the Applicability of Air Dose Rate Conversion Artificial Neural Networks Constructed from Fukushima Experience to Other Detectors’, Journal of Radiation Protection and Research, vol. 50, suppl. 1, pp. S112–S123
Keywords: Vegetation, Topographic, Airborne radiaiton monitoring, Artificial neural network
15:00 Poster panel: 155

Poster Number:
NSS-01-155

Explainable Radionuclide Identification Using FWHM-Aware Adaptive Banding in Gamma-Ray Spectroscopy (#1543)

S. Jang1, G. Song1, U. Lee1, J. Lee1, D. Kim2, J. Kim1, G. Cho1

1 KAIST (Korea Advanced Institute of Science and Technology), Department of Nuclear and Quantum Engineering, Daejeon, Republic of Korea
2 Pusan National University, Nuclear Systems Major, School of Mechanical Engineering, Pusan, Republic of Korea

Abstract

Machine learning has shown strong potential for radionuclide identification using gamma-ray spectroscopy. However, its black-box nature limits the physical interpretation of model predictions. In this study, a spectroscopy-tailored explainable artificial intelligence (XAI) framework for a 1D-CNN-based radionuclide identification model was investigated using gamma-ray spectra measured with a NaI(Tl) detector. The model was trained to classify four radionuclides: 22Na, 60Co, 137Cs, and 54Mn. To identify the spectral regions contributing to the CNN predictions, Grad-CAM, LIME, and Kernel SHAP were applied. In particular, because perturbation-based XAI methods are strongly affected by the definition of input features, two spectral banding strategies were compared: conventional uniform banding and FWHM-aware adaptive banding. The results showed that compared with uniform banding, the proposed adaptive banding provided more localized and physically interpretable attribution results in several cases. These findings suggest that detector-resolution-aware banding can improve the reliability and interpretability of XAI for gamma-ray spectroscopy.

References
[1] M. S. Bandstra, J. C. Curtis, J. M. Ghawaly Jr, A. C. Jones, and T. H. Joshi, “Explaining machine-learning models for gamma-ray detection and identification,” Plos one, vol. 18, no. 6, p. e0286829, 2023.
[2] J. Contreras and T. Bocklitz, “Explainable artificial intelligence for spectroscopy data: a review,” Pflügers Archiv-European Journal of Physiology,
vol. 477, no. 4, pp. 603–615, 2025.
[3] Y. Wang, Q. Yao, Q. Zhang, H. Zhang, Y. Lu, Q. Fan, N. Jiang, and W. Yu, “Explainable radionuclide identification algorithm based on the convolutional neural network and class activation mapping,” Nuclear Engineering and Technology, vol. 54, no. 12, pp. 4684–4692, 2022.
[4] B. Jeon, J. Kim, and M. Moon, “Explanation of deep learning–based radioisotope identifier for plastic scintillation detector,” Nuclear Technology, vol. 209, no. 1, pp. 1–14, 2023.
Keywords: Explainable Artificial Intelligence (XAI), Grad- CAM, kernel SHAP, LIME, Adaptive band
15:00 Poster panel: 157

Poster Number:
NSS-01-157

Source-Transferable Machine Learning-based Pulse Shape Discrimination in 3D-Printed Plastic Scintillators (#1703)

V. Anand1, K. Shah1, A. K. Gourishetty1

1 Indian Institute of Technology Roorkee, Roorkee, India

Abstract

This work demonstrates source-transferable neutron-gamma pulse-shape discrimination in 3D-printed plastic scintillators using compact deep neural networks trained on experimental waveforms. Additively manufactured plastic scintillators are attractive for application-specific neutron detectors because printing can produce nonplanar and architected geometries. However, their pulse shapes can depend on resin chemistry, dopant loading, and curing conditions. Therefore, discrimination algorithms validated on conventional liquid or cast plastic scintillators cannot be assumed to transfer directly to printed scintillators. Pulses were collected from 252Cf and AmBe sources using CAEN DT5751 and DT5730 digitizers, respectively, and analyzed using charge-comparison pulse-shape discrimination, unsupervised clustering, tree-based classifiers, one-dimensional convolutional neural networks, and fully connected deep neural networks. Charge-comparison methods were limited to 92-93% accuracy for the more overlapping 252Cf dataset, whereas the optimized network used smoothed, peak-aligned, amplitude-normalized waveforms and achieved 99.55% test accuracy on 252Cf. Without retraining, the same model achieved 99.91% inference accuracy on the independent AmBe dataset. Peak alignment was found to be essential as AmBe inference accuracy increased from 88.11% for unaligned raw waveforms to 99.91% for aligned waveforms. These results establish peak-aligned waveform learning as an effective route for robust neutron-gamma discrimination in 3D-printed plastic scintillators.

AcknowledgmentThis work was supported by the Ministry of Higher Education (MHRD), Government of India.
Keywords: 3D-printed plastic scintillator, machine learning, deep neural network, neutron-gamma discrimination, pulse-shape discrimination
15:00 Poster panel: 159

Poster Number:
NSS-01-159

Spectro-Temporal Gamma-Ray Anomaly Detection with Context-Adaptive Background Modeling (#2215)

H. Parrilla1, M. Bandstra1, R. Cooper1

1 Lawrence Berkeley National Laboratory, Berkeley, California, United States of America

Abstract

Gamma-ray anomaly detection and identification in complex environments requires background models that are accurate, robust to environmental variation, and interpretable enough to support adaptation given contextual information. We present Gaussian Process Prior NMF (GPP-NMF) spectro-temporal background modeling, combining the physically meaningful structure of Non-negative Matrix Factorization (NMF) in the spectral dimension with a Gaussian process prior (GPP) in the temporal dimension, parameterized by a smoothing hyperparameter λT. Evaluated on RADAI synthetic mobile search data, GPP-NMF outperforms standard spectral NMF in the low false alarm rate regime of operational interest, with a single fixed calibrated λT. We validate a principled approach for λT adaptation to contextual information by showing that the power spectrum of the logarithm of the total building solid angle seen by the detector — extractable from camera data in real time — closely matches the GPP prior power spectrum. Full contextual integration results, including on real-world data, will be presented.

AcknowledgmentThis work was performed under the auspices of the U.S. Department of Energy by Lawrence Berkeley National Laboratory (LBNL) under Contract DE-AC02-05CH11231. The project was funded by the U.S. Department of Energy, National Nuclear Security Administration, Office of Defense Nuclear Nonproliferation Research and Development.
Keywords: radiation detection, background modeling, non-negative matrix factorization, source identification
15:00 Poster panel: 161

Poster Number:
NSS-01-161

Optical Readout of Geiger–Müller Survey Instruments on a Coordinated Multicopter Fleet for Distributed Count-Rate Mapping (#2225)

S. Junnarkar1, A. Junnarkar1

1 Field Viewers inc, Austin, Texas, United States of America

Abstract

The primary objective is to describe and evaluate a multisensor architecture in which several small unmanned aircraft jointly support geographically registered ambient gamma survey without carrying a separate heavy scintillator and high-resolution pixel imager on every vehicle. The working hypothesis is that conventional handheld Geiger–Müller survey instruments, rigidly mounted with the numeric display visible to an onboard camera, can supply useful count-rate estimates when digits are recovered by image-space region selection, classification or template matching, and short-window temporal filtering that suppresses vibration-induced blur. The research design couples this optical readout path to a single mission manager that maintains a unified operator display, explicit multicopter formations to spread measurement locations along transects or grids, leader–follower roles with reassignment when radio links degrade, and a fixed policy in which facial-identity checks gate escalation to autonomous rerouting or alarm acknowledgement. Methods include hardware-in-the-loop bench comparison against an independent counting reference, latency measurement on embedded accelerators, and qualitative stress tests for glare, backlight change, and partial occlusion from neighboring rotors. Preliminary outcomes indicate stable decode at representative dose rates when temporal aggregation spans one to two seconds, inference on the order of tens of milliseconds per frame region, and graceful degradation when the display is shadowed. The conclusions are that display-mediated readout is a viable interface when spectroscopic identification is not required, and that formation metadata should be fused with decoded rates before mapping. Implications are outdoor line and grid flights with uncertainty accounting, handheld references, and optional spectrometer comparison before field deployment claims.

Keywords: unmanned aircraft, radiation survey, Geiger–Müller counter, optical character recognition, multicopter fleet, mission planning, human–machine interface, distributed mapping
15:00 Poster panel: 163

Poster Number:
NSS-01-163

Generative Overlay Augmentation for Robust Structural Region Segmentation in Dual-Energy X-Ray Cargo Container Imagery (#2263)

Y.-W. Kim1, K. Kim1, T. T.D. Pham1

1 Infiniq, AI Lab, Seoul, Republic of Korea

Abstract

Non-intrusive inspection of cargo containers via dual-energy X-ray radiography increasingly faces threats concealed within the container’s own structural void spaces, making segmentation of the structural region a necessary prerequisite for downstream anomaly detection. Two compounding factors hinder this task: inconsistent geometric distortion across operational scans, and path-integral structure–cargo overlay that prevents pixel-level human annotation in densely loaded regions. We formulate the task as binary segmentation and propose a regionwise generative overlay augmentation pipeline, in which Stable Diffusion is adapted via a three-stage scheme—LoRA, ControlNet, and inpainting—to synthesise structure–cargo overlay imagery. Polygon annotation is partitioned by visual confidence: structural polygons supply segmentation labels and ControlNet conditions, while cargo polygons serve as inpainting masks. The central hypothesis is that a model trained with the proposed structure–cargo overlay augmentation outperforms a baseline trained on real annotations alone, evaluated on two test partitions defined by the visual clarity of structure–cargo separation under overlay: Easy (clearly distinguishable) and Hard (separation challenging but feasible).

AcknowledgmentThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT, KCS) (IRIS RS-2025-25459707).
References
[1] T. W. Rogers et al., “Automated X-ray image analysis for cargo security,” J. X-Ray Sci. Technol., vol. 25, no. 1, pp. 33–56, 2017.
[2] N. Jaccard et al., “Detection of concealed cars in complex cargo X-ray imagery using deep learning,” J. X-Ray Sci. Technol., vol. 25, no. 3, pp. 323–339, 2017.
[3] World Customs Organization, Infiltration of Maritime Cargo Supply Chains: Organized Crime, Cocaine and the Internal Conspirator, Brussels, 2025.
[4] R. Rombach et al., “High-resolution image synthesis with latent diffusion models,” Proc. CVPR, 2022, pp. 10684–10695.
[5] E. J. Hu et al., “LoRA: Low-rank adaptation of large language models,” Proc. ICLR, 2022.
[6] L. Zhang, A. Rao, and M. Agrawala, “Adding conditional control to textto-image diffusion models,” Proc. ICCV, 2023, pp. 3836–3847.
[7] R. Sapkota et al., “YOLO26: Key architectural enhancements and performance benchmarking for real-time object detection,” arXiv:2509.25164, 2025.
[8] F. Li et al., “Mask DINO: Towards a unified transformer-based framework for object detection and segmentation,” Proc. CVPR, 2023, pp. 3041– 3050.
[9] Y. Fang et al., “EVA-02: A visual representation for neon genesis,” arXiv:2303.11331, 2023.
Keywords: X-ray cargo inspection, container security, semantic segmentation, generative data augmentation, latent diffusion models.
15:00 Poster panel: 165

Poster Number:
NSS-01-165

Development of Realistic Gamma-ray Spectrum Database Using Geant4 and U-Net-based Sim-to-Real Translation (#2356)

G. Kim1, 2, J. Hwang1, 2, D.Y. Oh1, 2, C. Kim3, J.-Y. Yeom1, 4

1 Korea University, Department of Bioengineering, Seoul, Republic of Korea
2 Korea University, Interdisciplinary Program in Precision Public Health, Seoul, Republic of Korea
3 Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
4 Korea University, School of Biomedical Engineering, Seoul, Republic of Korea

Abstract

Reliable gamma-ray spectrum databases are needed for data-driven radioisotope identification, but direct measurements of accident-related or short-lived radionuclides are often limited by safety regulations and isotope availability. Geant4 can generate synthetic spectra, but simulated spectra may differ from measured detector-domain spectra because of detector response, energy resolution, gain variation, and channel-domain distortion. In this study, we evaluated a U-Net-based sim-to-real translation framework to transform Geant4-simulated spectra toward measured detector spectra. Measured detector energy-resolution broadening and channel-domain augmentation were applied before translation, and a spatial-transformer-integrated U-Net was used to compensate for gain- and offset-related channel shifts. In validation, the model achieved a mixed-isotope training mean absolute error of 0.045214 and leave-one-out mean absolute error values of 0.068125 for unseen ²²Na and 0.047816 for ¹³⁷Cs. A photopeak-based fidelity analysis showed that 44% of ²²Na samples and 24% of ¹³⁷Cs samples satisfied the defined peak-position and peak-height criterion and a peak-height difference threshold of 0.05. These results indicate that U-Net-based translation can partially reduce the sim-to-real discrepancy in gamma-ray spectroscopy, while consistent reconstruction of detailed photopeak structures remains limited.

References
[1] Chanho Kim, Dongyoung Kim, Yeeun Lee, Chansun Park, Muhammad Nasir Ullah, Duckhyun Kim, Inyong Kwon, Seop Hur, Jung-Yeol Yeom, “Radiation resistance and temperature dependence of Ce:GPS
[2] S. Agostinelli et al., "Geant4-a simulation toolkit," Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 506, no. 3, pp. 250-303, 2003.
[3] O. Ronneberger, P. Fischer, and T. Brox, “U-Net: Convolutional networks for biomedical image segmentation,” in Proc. Medical Image Computing and Computer-Assisted Intervention (MICCAI), 2015, pp. 234–241.
Keywords: Artificial intelligence, gamma-ray spectroscopy, Geant4, radioisotope identification, sim-to-real translation
15:00 Poster panel: 167

Poster Number:
NSS-01-167

Real-Time Nuclide Identification via Physics-Region Preprocessing (#2437)

D. Shin1, I. Kwon2

1 Korea Atomic Energy Research Institute, Department of Advanced I&C Research, Daejeon, Republic of Korea
2 Yonsei University, Department of Radiological Science, Wonju, Republic of Korea

Abstract

This work addresses real-time identification of gamma-emitting nuclides released outside a damaged reactor using a network of low-cost Silicon photomultiplier (SiPM)–scintillator gamma detectors. Of all fission products, only a few reach the plant exterior in amounts sufficient to produce measurable photopeaks; using the NUREG-1465 source term for Pressurized Water Reactor (PWR) severe accidents, we reduce the monitored set to the dominant nuclides 85Kr, 131I, 132Te, 137Cs, 60Co, and 140Ba. For this set, we design a 2K+1 physics-region preprocessing front-end that places one region of interest on each target photopeak and Compton edge, producing compact features for small downstream classifiers, including the target on-chip deep-learning core. Because direct validation on a real off-site release is impractical, we evaluate the pipeline on a K=5 surrogate set of 133Ba, 22Na, 137Cs, 54Mn, and 60Co spanning the same 80 keV-to-1.3 MeV band on a NaI(Tl)-SiPM detector. On this surrogate, the 2K+1 preprocessing achieves 83.9% accuracy at 25 photopeak counts per window and 97.8% at 100, compared with 75.4% and 94.3% for a raw pulse-vector baseline.

Acknowledgment

This work was supported in part by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (RS-2022-00165164, RS-2022-00144419)

References
[1] IAEA, “The Fukushima Daiichi Accident: Technical Volume 1,” IAEA, Vienna, 2015.
[2] IAEA, “Method for Developing Arrangements for Response to a Nuclear or Radiological Emergency,” IAEA EPR-METHOD, Vienna, 2003.
[3] L. Soffer et al., “Accident Source Terms for Light-Water Nuclear Power Plants,” NUREG-1465, U.S. NRC, 1995.
[4] G. F. Knoll, Radiation Detection and Measurement, 4th ed., Wiley, 2010.
[5] C. G. Ryan et al., “SNIP, a statistics-sensitive background treatment,” Nucl. Instrum. Methods B, vol. 34, pp. 396–402, 1988.
[6] L. A. Currie, “Limits for qualitative detection and quantitative determination,” Anal. Chem., vol. 40, no. 3, pp. 586–593, 1968.
[7] M. Kamuda, J. Stinnett, and C. J. Sullivan, “Automated isotope identification algorithm using artificial neural networks,” IEEE Trans. Nucl. Sci., vol. 64, no. 7, pp. 1858–1864, 2017.
[8] ANSI N42.34, “Performance Criteria for Hand-Held Instruments for the Detection and Identification of Radionuclides,” American National Standards Institute, 2015.
[9] I. Kwon, D. Shin, J. Oh, C.-H. Kim and H. Kim, “Preprocessing Energy Intervals on Spectrum for Real-Time Radionuclide Identification,” IEEE Trans. Nucl. Sci., vol. 68, no. 8, pp. 2202–2209, Aug. 2021, doi: 10.1109/TNS.2021.3097389.
Keywords: Silicon photomultiplier (SiPM), real-time nuclide identification, physics-region preprocessing, deep learning, low-count gamma spectroscopy.
15:00 Poster panel: 169

Poster Number:
NSS-01-169

Development of a vehicle-mounted Directional radiation monitoring system using multiple NaI(Tl) detectors and an ANN algorithm (#2628)

H.K. Baek1, J.W. Lee1, S.M. Park1, M.Y. Park1, S.J. Jeong1, S.H. Choi1, J.S. Heo1, Y.H. Chung2, S.Y. Kim1, J.K. Shin1

1 Neosiskorea Co., Ltd., Daejeon, Republic of Korea
2 Yonsei University, Department of Radiation Convergence Engineering, Wonju, Republic of Korea

Abstract

Vehicle-based radiation monitoring systems are widely used for environmental radiation surveillance, nuclear emergency response, and radioactive contamination mapping. Conventional systems use large-area NaI(Tl) scintillation detectors with high sensitivity for low-count-rate radiation measurements. However, they have limitations such as poor energy resolution and the inability to provide directional information of radiation sources. To overcome these limitations, this study developed a vehicle-based radiation source direction detection system using nine NaI(Tl) detectors while maintaining high sensitivity and energy resolution. The system consists of nine Φ3” × 3” NaI(Tl) detectors. Four upper-layer detectors were arranged for rapid direction identification, one center detector was used for dose assessment, and four lower-layer detectors with lead collimators improved directional accuracy. Radiation source direction was estimated using detector count-rate ratios according to incident direction and distance. An ANN-based algorithm was applied for direction estimation. System performance was evaluated using a 137Cs (100 μCi). Energy resolution and sensitivity were evaluated at 23 cm, while angular resolution tests were conducted at 6 m with source angles varied from 0° to 90° at 10° intervals. The developed system showed approximately 6.8 times higher detection sensitivity than a conventional large-area NaI(Tl) detector system. The angular resolution was evaluated as 45° and 10° for the upper and lower detector layers, respectively, confirming the feasibility of radiation source direction detection in a vehicle-based system. Future work will focus on miniaturization through compact optical sensors, detector rearrangement, and signal-processing optimization.

Acknowledgment

This work was supported by the Nuclear Energy International Joint Research Project through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (MSIT) (No. RS-2025-25458886).

Keywords: Carborne, Environmental radiation, directional monitoring, Artificial Neural Network, Scintillation detector
15:00 Poster panel: 171

Poster Number:
NSS-01-171

Wavelet optimisation for improved photopeak extraction in low-count gamma-ray spectra (#2656)

J. Biggs1, C. Shenton-Taylor1

1 University of Surrey, School of Maths and Physics, Guildford, United Kingdom

Abstract

Detector networks are a potential method of surveillance of radiological material moving through urban environments. Such a network would require ways of automatically assessing collected spectra for non-background isotopes, particularly in count-starved spectra collected in environments with complex backgrounds. In 2018, the London-based SIGMA trial gathered 1.5 billion one-second gamma spectra using both stationary and mobile scintillator detectors. This work presents a wavelet analysis method optimised for use with count-starved gamma spectra. A range of 137Cs spectra were collected, both experimentally and simulated in Geant4, and combined with real-world SIGMA background data. A continuous wavelet transform was conducted on each spectrum, producing an associated scalogram with wavelet transform modulus maxima lines arising from spectral features. By using the ’straightness’ of these lines, it was shown to be possible to identify the presence of 137Cs with 95% accuracy, with a number of false positive identifications. Constraining certain metrics within the method reduced the number of false positives at the expense of overall detection accuracy. UK Ministry of Defence © Crown Owned Copyright 2026/AWE

Keywords: Gamma radiation, spectrum, SIGMA, wavelets
15:00 Poster panel: 173

Poster Number:
NSS-01-173

Real-Time Particle Hit Detection Using a 1D Convolutional Neural Network on a CAEN FPGA-Based Digitizer (#2722)

C. Tintori1, M. Brini1, A. Potenza1, F. Giordano1, M. Zanetti2, 3, A. Triossi2, 3, M. Sapkas2, 3

1 CAEN S.p.A., Viareggio, Italy
2 University of Padova, Physics and Astronomy, Padova, Italy
3 INFN Padova, Padova, Italy

Abstract

This study proposes a 1D Convolutional Neural Network (CNN) architecture designed for real-time particle hit detection, moving beyond traditional rigid triggering thresholds. By processing continuous data streams, including high-noise environments, our model demonstrates superior sensitivity in low Signal-to-Noise Ratio (SNR) regimes and pile-up events. We demonstrate that this approach successfully identifies particle signals and provides precise temporal metadata in real time, offering a robust alternative to conventional signal processing methods. Performance was evaluated on a scintillating detector.

References
[1] F. Fahim et al., “hls4ml: An Open-Source Codesign Workflow to Empower Scientific Low-Power Machine Learning Devices,” arXiv:2103.05579, 2021
Keywords: CNN, FPGA, HLS4ML, particle detection, digitizer
15:00 Poster panel: 175

Poster Number:
NSS-01-175

Development of an ANN-based Gamma-ray Spectrum Correction Algorithm for PVT Detectors (#2762)

J. Ra1, J. Kang1, Y.S. Chung1, Y.H. Chung1

1 Yonsei University, Department of Radiation Convergence Engineering, Wonju, Republic of Korea

Abstract

Environmental radiation monitoring systems require detectors that can measure radiation in real time and rapidly identify radionuclides. This study developed an artificial intelligence–based spectrum Correction algorithm that converts gamma-ray spectra acquired from polyvinyl toluene (PVT) detectors with limited energy resolution into spectra comparable to those of NaI(Tl) detectors. The proposed model used an artificial neural network (ANN)-based multi-layer perceptron (MLP) regressor with two hidden layers, each containing 64 nodes. Rectified Linear Unit (ReLU) and Adaptive Moment Estimation (Adam) were employed as the activation function and optimizer, respectively. The model was trained using PVT spectra as input and NaI(Tl) spectra as target output data to learn the spectral relationship between the two detector systems. Training datasets were generated using Geant4 Application for Tomographic Emission (GATE) for four radionuclides: Co-57, Ba-133, Cs-137, and Co-60. The simulation results demonstrated that the proposed model successfully generated NaI(Tl) photopeak features from PVT spectra. Representative results for Cs-137 yielded a Pearson correlation coefficient of 0.9996 and a root mean square error (RMSE) of 0.0038. Additionally, the energy resolutions at the 662 keV photopeak were found to be 5.94% for the actual NaI(Tl) spectrum and 5.96% for the predicted spectrum, indicating that the two spectra have highly consistent energy resolution characteristics. These results imply that the proposed model can generate spectra with characteristics comparable to those of NaI(Tl) detectors while maintaining the practical benefits of PVT detectors for radiation monitoring applications.

Acknowledgment

This research was supported by the Regional Innovation System & Education(RISE) program through the Gangwon RISE Center, funded by the Ministry of Education(MOE) and the Gangwon State(G.S.), Republic of Korea.(2025-RISE-10-006)

References
[1] Lowdon M, Martin PG, Hubbard MWJ, Taggart MP, Connor DT, Verbelen Y, Sellin PJ, Scott TB. Evaluation of Scintillator Detection Materials for Application within Airborne Environmental Radiation Monitoring. Sensors (Basel). 2019 Sep 4;19(18):3828.
[2] Knoll, G. F. (2010). Radiation detection and measurement. John Wiley & Sons.
[3] Daniel, G., Ceraudo, F., Limousin, O., Maier, D., & Meuris, A. (2020). Automatic and real-time identification of radionuclides in gamma-ray spectra: a new method based on convolutional neural network trained with synthetic data set. IEEE Transactions on Nuclear Science, 67(4), 644-653.
Keywords: Artificial neural network, environmental radiation monitoring, gamma-ray spectroscopy, PVT scintillator, spectrum correction.
15:00 Poster panel: 177

Poster Number:
NSS-01-177

measurement-guided x-ray image restoration using fourier stochastic differential equations (#2948)

S. Oh1, J. Lee1, S. Yoo1, J. Kim1, H.K. Kim1

1 Pusan National University, school of mechanical engineering, Busan, Republic of Korea

Abstract

Industrial X-ray imaging for nondestructive inspection requires high spatial resolution and high sensitivity, but phosphor-based detectors face a trade-off because increased phosphor thickness improves X-ray absorption while degrading spatial resolution through optical spreading. This study investigates a measurement-guided Fourier stochastic differential equation for detector X-ray image restoration. The proposed method defines a degradation path in the Fourier domain using measured detector characteristics. The relative modulation transfer function (MTF) models deterministic resolution loss, and the measured noise power spectrum guides stochastic perturbation. A neural restoration network is trained to reconstruct high-resolution images from intermediate degraded states conditioned on low-resolution observations. Experiments on printed circuit board X-ray images compared the proposed method with Wiener filtering, a regression baseline, and a conditional diffusion model (CDM). The proposed method improved low-resolution images and achieved image domain restoration quality comparable to the regression baseline and better than Wiener filtering, while CDM showed slightly lower structural fidelity in representative regions. Frequency domain analysis using MTF, contrast transfer function (CTF), and NNPS showed that both CDM and the proposed method closely followed the high-resolution MTF and that the proposed method showed higher CTF recovery in the mid-to-high frequency range. These results indicate that X-ray image restoration methods should be assessed using both image domain metrics and frequency domain characteristics.

Acknowledgment

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) under Grant RS-2024-00340520. S. Oh was supported by the Basic Science Research Program through the NRF funded by the Ministry of Education under Grant RS-2024-00408137.

References
[1] R. C. Gonzalez and R. E. Woods, Digital Image Processing, 4th ed. New York, NY, USA: Pearson, 2018.
[2] O. Ronneberger, P. Fischer, and T. Brox, “U-Net: Convolutional networks for biomedical image segmentation,” in Proc. Med. Image Comput. Comput.-Assist. Intervent. (MICCAI), 2015, pp. 234–241.
[3] C. Dong, C. C. Loy, K. He, and X. Tang, “Image super-resolution using deep convolutional networks,” IEEE Trans. Pattern Anal. Mach. Intell., vol. 38, no. 2, pp. 295–307, Feb. 2016.
[4] J. Ho, A. Jain, and P. Abbeel, “Denoising diffusion probabilistic models,” in Adv. Neural Inf. Process. Syst., vol. 33, 2020, pp. 6840–6851.
[5] C. Saharia, J. Ho, W. Chan, T. Salimans, D. J. Fleet, and M. Norouzi, “Image super-resolution via iterative refinement,” IEEE Trans. Pattern Anal. Mach. Intell., vol. 45, no. 4, pp. 4713–4726, Apr. 2023.
[6] Y. Song, J. Sohl-Dickstein, D. P. Kingma, A. Kumar, S. Ermon, and B. Poole, “Score-based generative modeling through stochastic differential equations,” in Proc. Int. Conf. Learn. Represent. (ICLR), 2021.
[7] D. P. Kingma and J. Ba, “Adam: A method for stochastic optimization,” in Proc. Int. Conf. Learn. Represent. (ICLR), 2015.
Keywords: Diffusion models, Fourier transforms, Image restoration, Stochastic differential equation, X-ray imaging
15:00 Poster panel: 179

Poster Number:
NSS-01-179

A General-Purpose Radionuclide Identification Model for HPGe Gamma-Ray Spectrometry (#3209)

J. Zickefoose1, H. Persson1, C. Cianci1

1 Mirion Technologies (Canberra) Inc, Physics, Meriden, Connecticut, United States of America

Abstract

Radionuclide identification in high‑purity germanium (HPGe) gamma‑ray spectra can be a challenging and time‑consuming task, particularly when complex samples contain many radionuclides that produce overlapping spectral features. In addition to sample emissions, HPGe detectors measure contributions from naturally occurring and environmental radionuclides, referred to as background. The measured sample spectrum is therefore the sum of sample and background contributions, and in most applications it is desirable to identify only the radionuclides present in the sample itself. While background subtraction is commonly performed using a separate background measurement, accurate identification near critical detection limits remains difficult, especially for low‑count or cluttered spectra.

We present a Siamese Neural Network (SNN)–based approach for radionuclide identification with background subtraction in HPGe gamma‑ray spectra that is generalizable to many detector models and geometries. By directly learning a similarity metric between foreground and background spectra, the method enhances sensitivity to weak spectral features while maintaining low false‑positive rates.

The network is trained on a large dataset containing spectra from over 500 radionuclides, generated using Monte Carlo simulations spanning more than 50 detector and geometry combinations and augmented with measured background data. We present the data generation methodology, training procedure, and performance results on both simulated and measured spectra. The results demonstrate that the SNN approach achieves performance comparable to or exceeding that of traditional spectral analysis techniques. This work provides a foundation for robust, automated radionuclide identification across diverse measurement conditions.

Keywords: Artificial Intelligence, background subtraction, gamma-ray spectrometry
15:00 Poster panel: 181

Poster Number:
NSS-01-181

15:00 Poster panel: 183

Poster Number:
NSS-01-183

15:00 Poster panel: 185

Poster Number:
NSS-01-185

High-Fidelity 3D MCNP Modeling for Waste Classification in PWRs (#1189)

C. Yoon1

1 Korea Hydro & Nuclear CO., LTD, Central Research Institute, Daejeon, Republic of Korea

Abstract

Accurate classification of radioactive waste is critical for determining disposal costs and ensuring safety during nuclear power plant decommissioning. However, generic models with simplified geometries and material compositions can lead to systematic misclassification. In this study, a high-fidelity 3D MCNP model of a pressurized water reactor (PWR) was developed to evaluate activation source terms and classify waste based on IAEA Safety Standards Series. The model includes the reactor pressure vessel (RPV), reactor vessel internals (RVI), and bioshield concrete, enabling realistic representation of complex structures. Activation analysis shows that Fe-55, Co-60, and Mn-54 are the dominant radionuclides in both the RPV and bioshield, qualitatively aligning with widely recognized reactor activation data and thereby validating the developed model. Based on specific activity, Fe-55 accounts for over 99% in both structures. However, applying radionuclide-specific activity limits results in a dramatic shift in the dominant contributor. In the bioshield concrete, the contribution of Fe-55 decreases from over 99% to approximately 16%, while C-14 becomes dominant at approximately 76%. This indicates that classification based solely on specific activity can lead to fundamental misclassification. The RPV is classified as low-level waste (LLW), whereas the bioshield meets the criteria for very low-level waste (VLLW). In contrast, generic models fail to accurately represent the reactor configuration, which can result in over-classifying the bioshield as LLW. The high-fidelity approach provides a quantitative basis for reclassification, directly contributing to the reduction of disposal volume. These results demonstrate that high-fidelity activation modeling is essential not only for improving classification reliability but also for avoiding systematic overestimation of waste classes and enabling more economically efficient decommissioning strategies.

Keywords: Monte Carlo methods, Nuclear energy, Radioactive waste, Waste management
15:00 Poster panel: 187

Poster Number:
NSS-01-187

Six-Degree-of-Freedom Pose Estimation for Safety Monitoring in a Nuclear Glovebox (#1287)

L. Mead1, C. Kind1, T. Scott1

1 University Of Bristol, Interface Analysis Centre, Bristol, United Kingdom

Abstract

Nuclear glovebox monitoring must recognise not only which objects are present, but whether their position and orientation indicate an operationally relevant state, such as an inverted container, a handled tool, or an object moving close to a glove during potentially hazardous work. This paper evaluates a two-camera six-degree-of-freedom vision pipeline for advisory operator support in a tabletop analogue of a nuclear glovebox containing a can, pliers, and screwdriver. Offline colour-and-depth pseudo-labels are generated and filtered to train a lightweight object detector and keypoint regressor. During live operation, the system performs object detection, keypoint-based pose recovery, masked depth refinement, temporal smoothing, and safety-state logging. On the validation split, the detector achieved 99.3% mean average precision at an intersection-over-union threshold of 0.5, and the live keypoint-and-depth-refinement pipeline ran at 8.5 frames per second on constrained hardware. These results show that pose-aware monitoring can support prototype glovebox alarms and auditable event records without running a high- capacity pose model online, suggesting a practical route toward advisory systems that improve situational awareness and post- task review while preserving operator judgement. Before such systems could be used operationally, further work is required to establish independent ground truth, model articulated tools, validate longer-term reliability, and build the necessary safety case.

Acknowledgment

Thanks to my supervisors Charlie Kind and Tom Scott, and colleagues at the Interface Analysis Centre, for their guidance, technical support, and feedback throughout this work.

References
[1] O. Tokatli, P. Das, R. Nath, L. Pangione, A. Altobelli, G. Burroughes,
E. T. Jonasson, M. F. Turner, and R. Skilton, “Robot-Assisted Glovebox
Teleoperation for Nuclear Industry,” Robotics, vol. 10, no. 3, p. 85, 2021.
[2] B. Wen, W. Yang, J. Kautz, and S. Birchfield, “FoundationPose: Unified
6D Pose Estimation and Tracking of Novel Objects,” in Proc. IEEE/CVF
Conf. Comput. Vis. Pattern Recognit., 2024, pp. 17868–17879.
[3] C. Rother, V. Kolmogorov, and A. Blake, “GrabCut: Interactive Fore-
ground Extraction Using Iterated Graph Cuts,” in ACM SIGGRAPH 2004
Papers, 2004, pp. 309–314.
[4] G. Jocher and J. Qiu, “Ultralytics YOLO11,” version 11.0.0, 2024.
[Online]. Available: https://github.com/ultralytics/ultralytics
[5] V. Lepetit, F. Moreno-Noguer, and P. Fua, “EPnP: An Accurate O(n)
Solution to the PnP Problem,” Int. J. Comput. Vis., vol. 81, no. 2, pp.
155–166, 2009.
[6] M. A. Fischler and R. C. Bolles, “Random Sample Consensus: A
Paradigm for Model Fitting with Applications to Image Analysis and
Automated Cartography,” Commun. ACM, vol. 24, no. 6, pp. 381–395,
1981.
[7] P. J. Besl and N. D. McKay, “A Method for Registration of 3-D Shapes,”
IEEE Trans. Pattern Anal. Mach. Intell., vol. 14, no. 2, pp. 239–256,
1992.
[8] J. Park, Q.-Y. Zhou, and V. Koltun, “Colored Point Cloud Registration
Revisited,” in Proc. IEEE Int. Conf. Comput. Vis., 2017, pp. 143–152.
[9] T. Hodaˇn, M. Sundermeyer, B. Drost, Y. Labb´e, E. Brachmann, F.
Michel, C. Rother, and J. Matas, “BOP Challenge 2023 on Detection,
Segmentation and Pose Estimation of Seen and Unseen Rigid Objects,”
in Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit. Workshops,
2024.
Keywords: Nuclear glovebox monitoring, 6DoF pose estimation, RGB-D sensing, computer vision, safety monitoring
15:00 Poster panel: 189

Poster Number:
NSS-01-189

Photonuclear Processes in a Tungsten Matrix Collimator for Spatially Fractionated Radiation Therapy (#1326)

I. E. Anokhin1, D. Ramazanov1

1 Institute for Nuclear Research, Kyiv, Ukraine

Abstract

Spatially fractionated radiation therapy using tungsten matrix collimators enables high peak-to-valley dose ratios and improved normal tissue sparing. At photon energies near 25 MeV, photonuclear interactions in tungsten induce activation and produce secondary neutrons, potentially affecting both dosimetric performance and radiation safety.

In this work, these processes were investigated using FLUKA Monte Carlo simulations of a modular tungsten-matrix collimator irradiated by a 25-MeV photon beam. Secondary neutron fluence distributions, energy spectra, and absorbed-dose maps in a silicon detector plane were evaluated and normalized to a photon fluence of approximately 1 × 10⁹ cm⁻². The calculated absorbed-dose profile exhibits a pronounced mini-beam structure with a peak dose of 6.16 × 10⁻⁴ Gy, a valley dose of 2.53 × 10⁻⁵ Gy, and a peak-to-valley dose ratio of 24.4. Neutron production is highest at the entrance to the collimator and decreases significantly beyond approximately 5 cm along the beam path, indicating substantial attenuation within the 9 cm tungsten structure. Folding the neutron spectra with energy-dependent fluence-to-dose conversion coefficients yields an ambient dose equivalent of 102 µSv in the collimator region and 0.62 µSv in the phantom region for the same irradiation.

The results demonstrate that photoneutron generation is strongly influenced by the collimator configuration and exhibits distinct spatial and spectral characteristics. Photoneutrons contribute to the dose outside the primary irradiation field, thereby increasing the valley dose and affecting the achievable peak-to-valley dose ratio. These findings underscore the importance of accounting for photonuclear effects during collimator optimization and shielding design for high-energy photon mini-beam therapy systems.

References
[1] Anokhin  I. E., Pugatch V. M., Ramazanov D. M., and Storozhyk D. V., "Matrix metal collimators studies for the spatially fractionated radiation therapy," 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-11
[2] Anokhin I. E., Pugatch V. M., and Ramazanov D. M., "Matrix metal collimators studies for the spatially fractionated radiation therapy. Part II: Tungsten, Tantalum and Iron Collimators," 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference, N-28-194
[3] Anokhin I. E., Pugatch V. M., and Ramazanov D. M., "Matrix metal collimators studies for the spatially fractionated radiation therapy. Part III: Particle spectrums," 2022 IEEE NSS/MIC/RTSD, NSS-03-243 
[4] FLUKA Collaboration, FLUKA: a multi-particle transport code, https://fluka.cern
[5] ICRP, Conversion Coefficients for use in Radiological Protection against External Radiation, ICRP Publication 74, Ann. ICRP 26(3-4), 1996
Keywords: radiation therapy, collimators, absorbed dose, photonuclear reactions, Monte Carlo methods
15:00 Poster panel: 191

Poster Number:
NSS-01-191

A Low-Energy X-ray Transmission Imaging Method for Detecting Metallic Microparticles in Single-Layer LiFePO4 Batteries (#1517)

D. Wang1, Y. Yang1

1 Tsinghua University, Department of Engineering Physics, Beijing, China

Abstract

Metallic foreign particles are critical safety hazards in lithium-ion battery manufacturing. To address the difficulty of detecting metallic microparticles in single-layer LiFePO4 cells, this work proposes a nondestructive detection method based on low-energy X-ray transmission imaging. Cu, Fe, and Ni particles are analyzed through attenuation modeling and simulation to evaluate the effects of photon energy, particle material, and particle thickness on transmission contrast. Preliminary imaging experiments are performed using 40keV X-rays, and weak abnormal signals are extracted by normal-sample normalization, filtering enhancement, threshold segmentation, and local SNR analysis. The results show that metallic microparticles can produce detectable local attenuation anomalies in low-energy X-ray images.

Acknowledgment

The authors would like to thank the Department of Engineering Physics, Tsinghua University, for experimental support and helpful discussions.

References
[1] J. Grabow, M. Osenberg, J. Hilger, I. Manke, and A. Latz, "Particle contamination in commercial lithium-ion cells---Risk assessment with focus on internal short circuits and replication by currently discussed trigger methods," Batteries, vol. 9, no. 1, 2023.
[2] P. R. Shearing, J. Gelb, N. P. Brandon, and S. J. Harris, "X-ray tomography for lithium ion battery research", Annual Review of Materials Research, vol. 48, pp. 1--27, 2018.
Keywords: Low-energy X-ray imaging, metallic foreign particles, nondestructive testing
15:00 Poster panel: 193

Poster Number:
NSS-01-193

Graph-Based Modeling of Organ and Lesion Radiomics Interactions in Theranostic SPECT/CT Imaging (#3206)

M. S. Azimi3, M. Cheraghi4, M. A. Ghodsi-Rad4, G. Divband5, H. Zaidi1, 2

1 Geneva University Hospital, Division of Nuclear Medicine & Molecular Imaging, Geneva, Genève, Switzerland
2 Odense University Hospital, Deptartment of Nuclear Medicine, Odense, Denmark
3 Obuda University, University Research and Innovation Center, Budapest, Hungary
4 Shahid Beheshti University, Department of Nuclear Medicine, Tehran, Iran (Islamic Republic of)
5 Jam Hospital, Department of Nuclear Medicine, Tehran, Iran (Islamic Republic of)

Abstract

Current radiomics approaches primarily focus on individual organs or lesions, which limits the ability to describe interactions within the body holistically. To address this limitation, we introduce a graph-based framework for modeling radiomics relationships between organs and lesions in theranostic SPECT/CT imaging. A cohort of 57 patients treated with ¹⁷⁷Lu-based radiopharmaceuticals was analyzed using post-therapy SPECT/CT. Organs were segmented using a deep learning–based approach, and lesions were delineated semi-automatically on SPECT images. From each region, 107 standardized radiomic features were extracted. Interactions between organs and lesions were quantified using a combination of linear similarity measures (Pearson, Spearman, cosine) and a nonlinear dependency metric based on normalized mutual information. These relationships were then represented as patient-specific graphs to capture system-level radiomics organization. The results reveal a non-uniform interaction pattern, where only a subset of organs exhibits strong associations with lesion characteristics. The highest coupling was observed in physiologically active regions such as the kidneys, liver, and spleen, with normalized mutual information values reaching approximately 0.66. Across all regions, nonlinear dependencies consistently showed higher values than linear metrics, indicating that complex relationships dominate radiomics interactions. Network representations further demonstrated a densely connected structure without prominent hubs, suggesting a distributed interaction model. Stability analysis confirmed reproducible patterns across patients, with near-perfect rank consistency and high agreement among top-ranked regions. These findings demonstrate that radiomics interactions between organs and lesions are structured, nonlinear, and reproducible. The proposed framework enables system-level interpretation of imaging data and may support the development of more informative biomarkers.

Keywords: Theranostic SPECT/CT, Radiomics, Digital Twin, Organ–Lesion Coupling, Network Modeling
15:00 Poster panel: 195

Poster Number:
NSS-01-195

Improved Scattering Modeling in CIVA-RT using a Next-Event Estimator (#1959)

S. Blas1, A. Touron1, H. Hutinet2, O. Petit3, J.M. Létang4, C. Le Loirec2

1 Université Paris-Saclay, CEA, List, Palaiseau, France
2 CEA, DES, IRESNE, DER, Service de Physique des Reacteurs et du Cycle, Cadarache, France
3 Université Paris-Saclay, CEA, Service d’Etudes des Réacteurs et de Mathématiques Appliquées, Gif-sur-Yvette, France
4 INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220 U1294, Villeurbanne, France

Abstract

In non-destructive testing (NDT), simulation is used to study radiation–matter interactions for various cases. CIVA software includes a radiographic testing (RT) module, which combines analytical and Monte Carlo (MC) approaches. The analytical component models primary photons, while the MC component handles scattered photons — a process that can become computationally intensive in complex configurations. Building on this, we introduce an estimator based on a split exponential track length method (seTLE) in the MC component of CIVA-RT, designed to reduce statistical variance and computational cost. This next-event estimator increases the probability of photon contributions to the detector by creating multiple pseudo-photons during the simulation. Its performance is evaluated using a convergence index and a Figure of Merit. Three configurations are studied: a simple configuration, a step wedge configuration with a distant detector, and an industrial weld case. Results show that the estimator provides significant efficiency gains. A detailed analysis of seTLE simulation shows that rare high-weight photons can cause sudden signal variations. These results demonstrate that the approach provides efficiency gains, making high fidelity simulations more tractable in industrial contexts.

AcknowledgmentWe acknowledge the financial support of the Cross-Disciplinary Program on Numerical simulation of CEA, the French Alternative Energies and Atomic Energy Commission.
References
[1] H. Hutinet, “Développement d’un estimateur déterministe appliqué au transport de particules neutres en méthode Monte-Carlo” Thèse de doctorat, Aix Marseille Université, 2024. [Online]. Available: https://theses.fr/s376078
[2] F.-X. Hugot et al., “Overview of the TRIPOLI-4 Monte Carlo code, version 12,” EPJ Nucl. Sci. Technol., vol. 10, p. 17, 2024, doi: 10.1051/epjn/2024018.
[3] N. Freud, J.-M. Letang, and D. Babot, “A hybrid approach to simulate X-ray imaging techniques, combining Monte Carlo and deterministic algorithms,” in IEEE Symposium Conference Record Nuclear Science 2004., Rome, Italy: IEEE, 2004, pp. 3075–3079. doi: 10.1109/NSSMIC.2004.1466331.
[4] H. Hutinet, P.-L. Antonsanti, C. Le Loirec, and D. Mancusi, “Accelerating split-exponential track length estimator on GPU for Monte Carlo simulations,” EPJ Nucl. Sci. Technol., vol. 11, p. 62, 2025, doi: 10.1051/epjn/2025053.
Keywords: Monte Carlo Method, Photon Scattering, Next-Event Estimator, Non-Destructive Testing
15:00 Poster panel: 197

Poster Number:
NSS-01-197

Development of a spectral unmixing method for gamma-ray spectra analysis : application to airborne measurements (#2081)

K. Castillo1, L. Patryl1, C.-P. Mano1, H. Paradis1, F. Carrel2, J. Bobin3

1 CEA, DAM-DIF, ARPAJON, France
2 CEA, LIST, SACLAY, France
3 CEA, IRFU, SACLAY, France

Abstract

The CEA develops and uses airborne detectors to carry out gamma mapping missions for various private and public entities, and various national and international authorities. The main objectives of these missions are : site monitoring (natural and anthropic contributions to environmental radioactivity), mapping contaminated areas, detecting and identifying radionuclides and radioactive sources.

Methods for analyzing the spectra acquired during these missions are being studied, with a view to improve decision thresholds and detection limits for various radionuclides of interest. A spectral analysis method called "spectral unmixing" has been developed, using a full spectrum analysis instead of the reference method based on regions of interest. This algorithm takes into account the response of the detector under study to an individual radionuclide, and estimates the proportions of the different radionuclides using a likelihood estimator. This method was shown to be accurate for reconstructing radionuclide activities, with improved sensitivity compared to the reference method.

The application of this algorithm to airborne detectors raises a number of challenging problems, such as taking into account the variability of spectral signatures linked to the environment and source shielding. An algorithm has been developed to address this problem. The algorithm was validated on simulated and experimental data, and improved the results of an airborne measurements campaign. This method can be implemented on the measurement system for real-time radionuclide identification.

Keywords: spectral unmixing, airborne measurements
15:00 Poster panel: 199

Poster Number:
NSS-01-199

Closed-Form Energy-Based Scatter Estimation for PET Image Reconstruction (#2160)

W. A. Williams1, 2, G. Chinn1, 2, C. S. Levin1, 2

1 Stanford University, Molecular Imaging, Stanford, California, United States of America
2 Stanford University, Radiology, Stanford, California, United States of America

Abstract

Scatter correction is a vital tool in enhancing SNR and contrast recovery in PET; however, existing techniques are computationally costly, need priors, and fail at lower counts. Our focus is to remedy these concerns using a novel closed-form solution. The technique differentiates itself by considering multi-Compton scatter (>2 scatter events) that twice convolve the single-scatter energy distribution revealing 9 states of joint probability density function. This then forms the Gram covariance matrix in our L2-regularized regression with Bhattacharrya weighting: an index of the probability density function overlap establishing appropriate penalties. Lastly, a quadratic cost function is implemented, and the solution is determined via gradient optimization method. Preliminary results from a Utah Phantom mimic’s coincidence data simulated in our GenII PETCoil in GATE v.8.2 determined a 10-fold decrease in magnitude of the L2 lambda compared to our previous technique suggesting better conditioning. The global scatter fraction for the phantom, compared to the ideal estimate from GATE came remarkably close: ~0.08% with the median error per sinogram bin centered around 0.00% (99.7% CI [0.00%,0.00%]) within GATE's ideal scatter fraction within an average of 360-410 counts/sinogram bin after correction (using SF = 1-True Fraction) suggesting a near perfect scatter correction. To determine the potential benefit of a prior joint probability density function of the anatomical Utah Phantom, we reran the algorithm receiving a global scatter fraction error of 3.13% with a per sinogram bin error of -1.12% (99.7% CI [-1.17%,-1.06%]) indicating an overcorrection. Our results conclude the following: the KN derivation closed-form solution approaches the ideal and a probabilistic prior is not needed.

Acknowledgment

This work was supported in part by NIH-NCI Grant 5T32CA11868119 and NIH-NIBIB Grant 5R01EB03103804.

References
[1] S. M. Shipley, M. C. Frederick, C. M. Filley, and B. M. Kluger, “Potential for misdiagnosis in community-acquired PET scans for dementia,” Neurol Clin Pract, vol. 3, no. 4, pp. 305–312, Aug. 2013, doi: 10.1212/CPJ.0b013e318296f2df.
[2] P. E. Kinahan and J. W. Fletcher, “Positron emission tomography-computed tomography standardized uptake values in clinical practice and assessing response to therapy.,” Semin Ultrasound CT MR, vol. 31, no. 6, pp. 496–505, Dec. 2010, doi: 10.1053/j.sult.2010.10.001.
[3] T. G. Turkington, “Introduction to PET Instrumentation,” J Nucl Med Technol, vol. 29, no. 1, p. 4, Mar. 2001, [Online]. Available: http://tech.snmjournals.org/content/29/1/4.abstract
[4] N. Efthimiou, J. S. Karp, and S. Surti, “Data-driven, energy-based method for estimation of scattered events in positron emission tomography,” Phys Med Biol, vol. 67, no. 9, p. 095010, May 2022, doi: 10.1088/1361-6560/ac62fc.
[5] S. Amir Zaman Pour, A. Rezaei, F. Jansen, K. Baete, G. Schramm, and J. Nuyts, “Strengths and weaknesses of energy-based scatter estimation using three basis functions.,” Phys Med Biol, vol. 71, no. 4, Feb. 2026, doi: 10.1088/1361-6560/ae456e.
Keywords: PET, Compton Scatter, EBSE, LSQR, Klein-Nishina
15:00 Poster panel: 201

Poster Number:
NSS-01-201

Hybrid Semantic–Keyword Analysis for the Classification of Nuclear Fuel Cycle Activities Using Open-Source Information (#2241)

Y.W. Lee1, S.A. Choi1, S.A. Kim1, C.H. Min2, Y.H. Chung2, J.J. Ahn1

1 Yonsei University, Division of Data Science, Wonju, Republic of Korea
2 Yonsei University, Department of Radiation Convergence Engineering, Wonju, Republic of Korea

Abstract

This study proposes a hybrid semantic–keyword analysis framework for automatically identifying and classifying nuclear fuel cycle-related activities using open-source text data. In the safeguards system of the International Atomic Energy Agency, continuous monitoring and analysis of nuclear fuel cycle activities are required; however, existing approaches rely heavily on expert-driven manual review, limiting efficient processing of large volumes of unstructured text data. To address this issue, nuclear fuel cycle-related news articles collected from Google News were used to construct profiles for seven nuclear fuel cycle activities. Each activity was represented by combining semantic information derived from Sentence-BERT embeddings with keyword importance obtained using class-based TF-IDF. Subsequently, key sentences were extracted from IAEA news articles, and activity classification was performed by integrating semantic and keyword similarity for each activity category. Performance evaluation results showed that the proposed method achieved a Top-1 accuracy of 57.14%, a Top-3 accuracy of 85.71%, and a mean reciprocal rank of 0.738. In addition, the actual activity category was generally included within the top candidate groups, showing that the proposed framework reflects the semantic relationships and complex characteristics among nuclear fuel cycle activities. This study demonstrates the feasibility of automating open-source-based nuclear fuel cycle activity analysis and suggests the potential for future extension to an Additional Protocol-based automatic declaration target identification system. The results also highlight the applicability of data-driven analytical approaches for safeguards and regulatory support.

Acknowledgment

This work was supported by the Nuclear Safety Research Program through the Korea Foundation Of Nuclear Safety using the financial resource granted by the Nuclear Safety and Security Commission of the Republic of Korea (No. RS-2026-25538205)

References
[1] N. Reimers and I. Gurevych, “Sentence-BERT: Sentence embeddings using siamese BERT-networks,” in Proc. 2019 Conf. Empirical Methods Natural Language Processing and 9th Int. Joint Conf. Natural Language Processing (EMNLP-IJCNLP), Hong Kong, China, 2019, pp. 3982–3992.
[2] M. Grootendorst, “BERTopic: Neural topic modeling with a class-based TF-IDF procedure,” 2022, arXiv:2203.05794.
[3] International Atomic Energy Agency, “Information collection and evaluation.” Accessed: May 11, 2026, [Online]. Available: https://www.iaea.org/topics/information-collection-and-evaluation
Keywords: Nuclear fuel cycle activities, Open-source information, Hybrid semantic–keyword analysis, Text classification, IAEA safeguards
15:00 Poster panel: 203

Poster Number:
NSS-01-203

Selective Use of Directionally Informative Non-Photopeak Events for Low-Count Industrial Gamma Imaging (#2392)

L. Lei1, D. Zhang1, Y. Zhang1, Z. Lyu1, T. Ma1

1 Tsinghua University, Beijing, China

Abstract

High-performance industrial gamma imaging under count-limited conditions is challenging, particularly for medium- and high-energy radionuclides where photopeak statistics are limited. However, some non-photopeak Compton-related events still retain directional information. We propose a directionally informed multi-energy-window reconstruction method that selectively incorporates such events. Monte Carlo spectral decomposition was used to define energy windows and estimate useful-event fractions. Window-specific projection data were paired with matched system matrices and jointly reconstructed using weighted MLEM.

The method was evaluated with a self-collimating industrial gamma camera for ¹³⁷Cs imaging. In point-source experiments, 30 s multi-window reconstruction achieved localization accuracy comparable to 90 s photopeak-window-only MLEM. In structured-source and short-frame dynamic imaging, it reduced background artifacts and improved localization stability. These results show that selective use of directionally informative non-photopeak events can improve event utilization and reconstruction robustness under low-count industrial gamma imaging conditions.

Keywords: Industrial gamma camera, Multi-energy-window reconstruction, Low-count gamma imaging
15:00 Poster panel: 205

Poster Number:
NSS-01-205

An Optical Surrogate Framework for Three-Dimensional Fusion Source Reconstruction (#2548)

Z. Zhang1, 2, Y. Yang1, 2

1 Tsinghua University, Department of Engineering Physics, Beijing, China
2 Tsinghua University, Key Laboratory of Particle and Radiation Imaging, Ministry of Education, Beijing, China

Abstract

Three-dimensional reconstruction of fusion neutron sources is critical for diagnosing burn-region morphology and implosion asymmetry in inertial confinement fusion, yet the recoverable morphology is severely limited by sparse and geometrically constrained diagnostic views. This work proposes an optical surrogate framework to study information-driven sparse-channel layout design for fusion neutron source reconstruction, offering controllable source morphology, low cost, and ease of iteration compared to direct neutron diagnostics. The core motivation is to treat limited-view reconstruction not only as an inverse-algorithm problem, but also as a constrained layout-design problem. A conceptual design employing Latin hypercube sampling generates candidate layouts within admissible geometries, followed by greedy selection. The optical surrogate tests the shared inverse-problem structure using movable point-like optical sources, directional fiber channels, rather than reproducing neutron transport physics. Preliminary fiber-response measurements reveal finite-acceptance soft-channel behavior with a transverse full width at half maximum of approximately 2.7 mm. Theoretical reconstruction using a discrete multi-point-source design yields a detector-domain residual of 0.038, a source-correlation coefficient of 0.998, and a maximum relative strength-ratio error of approximately 7.2%. These results establish a forward-model basis for subsequent layout optimization and future migration to neutron-response matrices.

References
[1] D. N. Fittinghoff, N. Birge, and V. Geppert-Kleinrath, “Neutron imaging of inertial confinement fusion implosions,” Rev. Sci. Instrum., vol. 94, no. 2, Art. no. 021101, Feb. 2023, doi: 10.1063/5.0124074.
[2] P. L. Volegov, C. R. Danly, F. E. Merrill, R. Simpson, and C. H. Wilde, “On three-dimensional reconstruction of a neutron/x-ray source from very few two-dimensional projections,” J. Appl. Phys., vol. 118, no. 20, Art. no. 205903, Nov. 2015, doi: 10.1063/1.4936319.
[3] P. L. Volegov et al., “Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using spherical harmonic decomposition,” J. Appl. Phys., vol. 122, no. 17, Art. no. 175901, Nov. 2017, doi: 10.1063/1.4986652.
[4] P. L. Volegov et al., “Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion,” Rev. Sci. Instrum., vol. 92, no. 3, Art. no. 033508, Mar. 2021, doi: 10.1063/5.0042860.
[5] F. E. Merrill et al., “The neutron imaging diagnostic at NIF (invited),” Rev. Sci. Instrum., vol. 83, no. 10, Art. no. 10D317, Aug. 2012, doi: 10.1063/1.4739242.
[6] M. D. McKay, R. J. Beckman, and W. J. Conover, “A comparison of three methods for selecting values of input variables in the analysis of output from a computer code,” Technometrics, vol. 21, no. 2, pp. 239–245, May 1979, doi: 10.1080/00401706.1979.10489755.
Keywords: Fusion source reconstruction, Latin hypercube sampling, optical surrogate, sparse-channel reconstruction, system matrix
15:00 Poster panel: 207

Poster Number:
NSS-01-207

Adaptive Tetrahedral Mesh Reconstruction for Industrial Computed Tomography (#2942)

J. Lee1, Y. Hong1, S. Yoo1, S. Oh1, H.K. Kim1

1 Pusan National University, Computational X-ray Imaging Laboratory, School of Mechanical Engineering, Busan, Republic of Korea

Abstract

Industrial X-ray computed tomography (CT) is widely used for non-destructive inspection and generation of geometric models. However, conventional voxel-based CT reconstruction on a fixed Cartesian grid causes partial-volume blurring and possible geometric errors when converted into surface or CAD models. This work presents an interface-adaptive tetrahedral mesh-based iterative reconstruction framework for industrial CT. The method estimates nodal attenuation coefficients directly on an unstructured mesh. X-ray projection and backprojection are performed by an NVIDIA OptiX-accelerated projector, which computes ray-mesh intersections, segment lengths, and barycentric weights, and backprojects residuals using the SIRT algorithm. To improve boundary representation, the reconstructed field is used to detect interface-related edges, locally refine the mesh, and displace vertices. For each candidate vertex, a local attenuation-gradient direction is estimated from neighboring nodes. The neighbors are divided across the estimated normal, and the vertex is shifted toward the attenuation mid-level between regions while enforcing element quality constraints. Simulated projection studies showed the proposed adaptive mesh reconstruction preserved overall structure while producing sharper material boundaries than voxel-based SIRT. Global structural similarity improved, particularly in regions containing material interfaces. These results indicate the framework reduces boundary blurring, supporting more accurate defect sizing and dimensional measurement in industrial testing.

Acknowledgment

This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) under Grant RS-2024-00340520. J. Lee and Y. Hong were supported by the Korea Institute of Energy Technology Evaluation and Planning (KETEP) and the Ministry of Climate, Energy and Environment (MCEE) of the Republic of Korea under Grant RS-2024-00398425.

References
[1] Merckx, J., den Dekker, A. J., Sijbers, J., De Beenhouwer, J. 2025, ‘DAMMER: Direct Adaptive Multi-Resolution MEsh Reconstruction From X-Ray Measurements’, IEEE Trans. Comput. Imag., vol. 11, pp. 926–941
[2] Nagai, Y., Ohtake, Y., Suzuki, H. 2016, ‘CT reconstruction on unstructured mesh for multi-material object’, Proc. 19th World Conf. Non-Destructive Testing, Munich, Germany
[3] Buyens, F., Quinto, M. A., Houzet, D. 2013, ‘Adaptive mesh reconstruction in X-ray tomography’, Proc. MICCAI Workshop Mesh Processing Med. Image Anal., Nagoya, Japan
[4] Boutchko, R., Sitek, A., Gullberg, G. T. 2013, ‘Practical implementation of tetrahedral mesh reconstruction in emission tomography’, Phys. Med. Biol., vol. 58, no. 9, pp. 3001–3022
Keywords: Computed tomography, Industrial X-ray imaging, Tetrahedral Mesh-based reconstruction
15:00 Poster panel: 209

Poster Number:
NSS-01-209

Forward Simulation of High-Energy XPCI Using XRM-Derived Semiconductor Package Phantoms (#2980)

U. Lee1, S. Jang1, D. Kim1, 2, S. Lee1, Y. Kim1, G. Song1, J. Lee1, G. Cho1, J. Kim1

1 Korea Advanced Institute of Science and Technology, Department of Nuclear and Quantum Engineering, Daejeon, Republic of Korea
2 Pusan National University, Nuclear Systems Major, School of Mechanical Engineering, Busan, Republic of Korea

Abstract

This study presents a forward simulation of high-energy X-ray phase-contrast imaging (XPCI) for semiconductor package inspection using an X-ray microscopy (XRM)-derived structural phantom. A projected phantom from an experimental laboratory XRM reconstruction stack was used as a geometry prior rather than quantitative material ground truth. The projected grayscale phantom was percentile-normalized and mapped to simplified Cu/Si refractive-index distributions. Under the proposed long-beamline high-energy synchrotron XPCI conditions, the simulated XPCI intensity and retrieved phase images reproduced characteristic package structures, including stacked layers and metal interconnect regions. The finite-source-induced blur was on the order of the detector pixel size, while the selected intra-bump feature showed higher local visibility in the retrieved phase image than in the simulated intensity image. This work extends idealized-phantom simulations to a laboratory-XRM-reconstructed semiconductor package structure under long-beamline high-energy synchrotron XPCI conditions.

References
[1] A. Snigirev, I. Snigireva, V. Kohn, S. Kuznetsov, and I. Schelokov, “On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation,” Rev. Sci. Instrum., vol. 66, no. 12, pp. 5486–5492, Dec. 1995
[2] J. Kim and J.-H. Lim, “Exploring high-energy X-ray phase-contrast microscopy at a diffraction-limited storage ring,” NDT&E Int., vol. 155, Art. no. 103395, 2025.
[3] S. Huhn, L. M. Lohse, J. Lucht, and T. Salditt, “Fast algorithms for nonlinear and constrained phase retrieval in near-field X-ray holography based on Tikhonov regularization,” Opt. Express, vol. 30, no. 18, pp. 32871–32898, 2022.
Keywords: X-ray phase-contrast imaging, semiconductor package, wave propagation simulation, fourth-generation storage ring
15:00 Poster panel: 211

Poster Number:
NSS-01-211

Investigating Identifiability in Joint Transmission–Backscatter X-ray Image Registration with Energy-Dependent Source Geometry (#1740)

H. Joo1, Y. Choi2, J. Park2, C.H. Lim3, J. Lee2, H.J. Yang4, 5

1 Pohang University of Science and Technology (POSTECH), Department of Electrical Engineering, Pohang, Republic of Korea
2 Korea Research Institute of Ships and Ocean Engineering (KRISO), Daejeon, Republic of Korea
3 M1 International Inc., Daejeon, Republic of Korea
4 Seoul National University, Department of Electrical and Computer Engineering, Seoul, Republic of Korea
5 Seoul National University, Institute of New Media and Communications, Seoul, Republic of Korea

Abstract

X-ray scannings are widely adopted by customs to control containers. Transmission and backscatter X-ray imaging are often jointly employed to enhance material discrimination and detection robustness in cargo inspection systems. However, the two modalities typically operate at substantially different photon energy levels, leading to energy-dependent interaction volumes and effective source geometries that cannot be simultaneously aligned. As a result, image registration becomes a prerequisite for joint analysis and decision-making based on transmitted and backscattered measurements, yet it is fundamentally ill-posed because consistent spatial correspondence between the two imaging processes is not directly observable. In this work, we investigate this identifiability issue in joint transmission--backscatter X-ray image registration by explicitly modeling energy-dependent source geometry and imaging physics. We show that mismatched photon energies can induce structural ambiguity, such that multiple spatial alignments may remain similarly plausible under joint interpretation.

References
[1] A. M. Wajid, M. R. Abdelnour, A. Naz, G. Liu, Y. Wang, Z. Li, X. Li, L. Zhang, Z. Liu, and J. Liu, ‘X-ray backscattering: design, applications, and prospects in non-destructive evaluation’, J. Radioanal. Nucl. Chem., vol. 334, no. 5, pp. 3033–3054, May 2025.
[2] B. Tracey, M. Schiefele, C. Alvino, E. Miller, and O. Al-Kofani, “Combined use of backscattered and transmitted images in x-ray personnel screening systems,” in Signal Processing, Sensor Fusion, and Target Recognition XXI. SPIE, May 2012.
[3] G. An, J. Park, and H. Seo, “Dual-energy backscatter X-ray imaging for material discrimination,” in 2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conference (RTSD). IEEE, Oct. 2024, pp. 1–1.
[4] S. Huang, X. Wang, Y. Chen, J. Xu, T. Tang, and B. Mu, “Modeling and quantitative analysis of X-ray transmission and backscatter imaging aimed at security inspection,” Opt. Express, vol. 27, no. 2, pp. 337–349, Jan. 2019.
Keywords: Transmission/backscatter X-ray imaging, image registration, identifiability, energy-dependent source geometry, cargo inspection.
15:00 Poster panel: 213

Poster Number:
NSS-01-213

Development of a UAV-Mounted Radiation Survey System Integrating LaBr3(Ce) Detectors and LiDAR (#1003)

Y.-Y. Ji1, W. Ji1, K. Kim1, M.J. Kim1

1 Korea Atomic Energy Research Institute, Environmental Safety Technology Research Division, Daejeon, Republic of Korea

Abstract

To facilitate the highly efficient and accurate surveying of radioactively contaminated areas, this study presents the development of an advanced UAV-mounted integrated survey system capable of the simultaneous, real-time measurement of 3D geospatial information and environmental radiation data. The hardware architecture is robustly constructed, integrating two sets of two-inch LaBr3(Ce) detectors for high-resolution gamma spectrometry. This is combined with a LiDAR sensor for acquiring precise 3D terrain topography, a GPS, and a laser altimeter to ensure accurate spatial referencing. To guarantee operational stability during flight, the payload design incorporates specialized vibration-damping mounts and a lightweight 1.5-millimeter aluminum housing. Furthermore, a high-speed LTE router network was introduced to reliably handle the transmission of large-capacity data streams to the ground station. 
The practical efficacy of the system was rigorously validated through extensive flight tests conducted over radioactively contaminated regions in Fukushima. When aerial measurements were mathematically converted to dose rates at one meter above ground level, the results demonstrated highly satisfactory performance, showing a strong statistical correlation with baseline data obtained using conventional backpack-type ground survey equipment. Crucially, by mapping real-time energy spectra directly onto the acquired 3D geospatial models, the system successfully enabled the comprehensive, multi-dimensional identification of specific high-level contamination hotspots. Moving forward, by integrating AI to further refine advanced topographical correction algorithms, this autonomous system is expected to significantly enhance the rapid and precise generation of contamination maps, providing critical support for emergency response.

AcknowledgmentThis work was supported by the Ministry of Science and ICT (MSIT) of the Republic of Korea (Project No. RS-2022-00144210).
References
[1] Y. Sanada and T. Torii, “Aerial radiation monitoring around the Fukushima Adi-ichi nuclear power plant using an unmanned helicopter,” J. Enviorn. Radioact. vol. 139, pp. 294-299, 2015.
[2] Y. Sanada, T. Orita, and T. Torii, “Temporal variation of dose rate distribution around the Fukushima Daiichi nuclear power station using unmanned helicopter,” Appl. Radiat. Isot. vol. 118, pp. 208-216, 2016. 
[3] Y.-Y. Ji, S. Joung, W. Ji, K. Ochi, M. Sasaki, and Y. Sanada, “Performance of UAV-based airborne gamma-ray spectrometry for wide-area radiation monitoring of contaminated sites,” J. Radiol. Prot. vol. 45, 042501, 2025.
[4] Y.-Y. Ji, W. Ji, K. Kim, M.J. Kim, K. Ochi, Y. Morishita, and Y. Sanada, “Practical approach of airborne gamma-ray spectrometry using UAVs for evaluating ground-level dose rates,” Radiat. Phys. Chem. vol. 244, 113781, 2026.
Keywords: UAV-mounted system, Radiation survey, 3D geospatial information, LiDAR, LaBr3(Ce) detector.
15:00 Poster panel: 215

Poster Number:
NSS-01-215

Development of a Handheld Uranium Enrichment Analyzer Based on LaBr3 Detector and Relative Detection Efficiency Self-Calibration Method (#1069)

G. Liu1, H. Zhou1, J. Li1

1 China institute of atomic energy, Department of Radiochemistry, Beijing, China

Abstract

To meet the on-site inspection requirements for uranium materials, a handheld uranium enrichment analyzer based on a LaBr3 detector and the relative detection efficiency self-calibration method was developed. The adopted LaBr3:Ce crystal has a size of 38.1mm in diameter and 25.4mm in thickness, with an energy resolution of 2.9% at 662keV. The handheld uranium enrichment analyzer is equipped with a 4.5-inch touchscreen. It features overall dimensions of 145×75×58mm and a weight of 800g, supporting continuous operation for more than 8 hours. Test results from six NBS standard samples show that for uranium samples with a mass≥200g, a ²³⁵U enrichment≥0.711%, and a measurement time≥1800s, the relative deviation of the measured ²³⁵U enrichment is less than 8.0%. This device can be applied to the verification and measurement of ²³⁵U enrichment in uranium materials.

References
[1] T.E. Sampson, T.A. Kelley, and D.T. Vo. Application Guide to Gamma-Ray Isotopic Analysis Using the FRAM Software. Los Alamos National Laboratory report LA-14018 (2003)
[2] Vo Duc Ta, McMath, Garrett Ear. Testing the HM-5s and NaIGEM code. Los Alamos National Laboratory report LA-UR-20-23051(2020)
[3] P. Mortreau, R.Berndt. Measurement of 235U enrichment with a LaBr3 scintillation detector. Nuclear Instruments and Methods in Physics Research A 620 (2010) 324–331.
[4] William H. Geist, Peter A. Santi, Martyn T. Swinhoe. Nondestructive Assay of Nuclear Materials for Safeguards and Security(Second Edition).ISBN 978-3-031-58277-6.2024
Keywords: handheld, ²³⁵U enrichment analyzer, LaBr3 detector, on-site inspection, nuclear safeguards
15:00 Poster panel: 217

Poster Number:
NSS-01-217

Neutron Response Evaluation of Miniature Spherical Li-glass scintillators for Optical-Fiber-Based Detectors (#1115)

Y. Saito1, Y. Oshima1, W. Kitsuki1, K. Watanabe1

1 Kyushu University, Applied Quantum Physics and Nuclear Engineering, Fukuoka, Japan

Abstract

Boron Neutron Capture Therapy (BNCT) and high-flux pulsed neutron sources such as J-PARC require reliable real-time neutron monitoring with minimal perturbation of the irradiation field. We have been developing miniature optical-fiber-based neutron detectors using small Li-glass scintillators mounted at the fiber tip. Conventionally, the scintillator pieces were prepared by crushing bulk Li-glass, producing irregularly shaped fragments that introduce geometric uncertainties and complicate quantitative response evaluation by Monte Carlo simulation. To overcome this, an aerodynamic polishing technique was established to shape Li-glass fragments into well-defined spherical particles with diameters of 100 to 500 μm without significant degradation in light yield. The spherical geometry enabled quantitative prediction of the wall effect through PHITS Monte Carlo simulations with a quenching model based on Birks’ law, and the simulated pulse-height spectra showed excellent agreement with experimental data obtained from spheres of various diameters (220–450 μm). This approach provides a robust framework for the precise design and manufacturing of miniature neutron detectors for high-intensity fields.

AcknowledgmentThis work was supported by a research grant from Murata Science and Education Foundation.
References
[1] H. Tanaka, Y. Sakurai, T. Takata et al., Note: Development of real-time epithermal neutron detector for boron neutron capture therapy, Rev. Sci. Instrum., 88, 023303 (2017).
[2] A. Ishikawa, K. Watanabe, A. Yamazaki et al., Evaluation of the thermal neutron sensitivity, output linearity, and gamma-ray response of optical fiber-based neutron detectors using Li-glass scintillator, Nucl. Instrum. Methods Phys. Res. A, 1025, 166074 (2022).
[3] T. Sato, Y. Iwamoto, S. Hashimoto et al., Recent improvements of the particle and heavy ion transport code system – PHITS version 3.33, J. Nucl. Sci. Technol., 61, 127–135 (2024).
[4] K. Watanabe, Y. Oshima, N. Shigyo, Y. Hirata, Evaluation of quenching characteristics of Li-containing scintillators, Jpn. J. Appl. Phys., 63, 042001 (2024).
Keywords: neutron detector, boron neutron capture therapy, Li-glass scintillator, optical-fiber-based detector, wall effect
15:00 Poster panel: 219

Poster Number:
NSS-01-219

Time-Resolved Imaging of Radioactive Gas with the 4π Gamma-Ray Imager C3G (#1185)

Y. Kitayama1, H. Nakai1, K. Enomoto3, N. Yamada3, K. Hitomi2, M. Nogami2, N. Kawachi3, 1

1 Fukushima Institute for Research, Education and Innovation, Plant Imaging research Unit, Fukushima, Japan
2 Tohoku University, Sendai, Japan
3 National Institutes for Quantum Science and Technology, Takasaki, Japan

Abstract

The Coded Cube Camera for Gamma-ray (C3G) is a 4π gamma-ray imager designed to estimate gamma-ray source distributions from direction-dependent detector response patterns.  In this study, we developed a 24-detector C3G consisting of 24 HR-GAGG scintillators and applied it to a plant radioisotope (RI) imaging experiment using 11CO2 gas.  In the plant RI imaging experiment, approximately 300 MBq of 11CO2 gas was supplied to a plant placed in an experimental chamber to image the transport of 11C-labeled photosynthates within the plant.  During this experiment, the C3G was placed outside the chamber, and the dynamics of 11CO2 gas were continuously measured with an acquisition time of 1 s per measurement.  As a result, the inflow of the gas into the chamber was clearly visualized.  In addition, the reconstructed image intensity decreased exponentially over time.  The half-life estimated from this intensity change was 20.70 min, which was in good agreement with the known half-life of 11C, 20.34 min.  These results demonstrate that the 24-detector C3G can visualize dynamic gaseous radioactive sources and estimate temporal changes in radioactivity from reconstructed image intensity.  This capability is expected to be useful for applications such as radioactive gas leakage monitoring, environmental monitoring, and nuclear security.

AcknowledgmentThis work was supported by JSPS KAKENHI Grant Number 26K03212. The authors thank the members of the Radiotracer Imaging Project, QST, for their valuable support during the experiment.
Keywords: gamma-ray imgaing, plant RI imaging
15:00 Poster panel: 221

Poster Number:
NSS-01-221

Performance Evaluation of a Fast Fission Neutron Coincidence Counting System (#1196)

Y. Toh1, M. Maeda1, M. Komeda1

1 Japan Atomic Energy Agency, Nuclear Science and Engineering Center, Ibaraki, Japan

Abstract

Characterization of nuclear fuel in fuel debris is essential for the decommissioning of the Fukushima Daiichi Nuclear Power Station. The fast fission neutron coincidence counting (FFCC) method, which is less sensitive to neutron absorbers than conventional thermal-neutron-based techniques, was investigated using Monte Carlo simulations with PHITS. A cylindrical unit can containing fuel debris was modeled, and four detector configurations with 24–72 liquid scintillator detectors were compared. Fast neutron coincidence counting efficiency decreased as the number of detectors decreased, whereas the quantification limit did not vary monotonically; the 56-detector configuration provided the best performance. This indicates that an optimal number of detectors exists, as gains in coincidence events are offset by reduced efficiency in distant detectors and increased background counts. Evaluation of the effective dose showed that shielding with lead and boron-loaded polyethylene reduced the dose around the system below the access limit for personnel, without significantly affecting measurement performance. These findings provide useful guidelines for the design of practical FFCC systems.

Acknowledgment

This work supported by the Decommissioning, Contaminated Water and Treated Water Management Project funded by the Ministry of Economy, Trade and Industry (METI), Japan.

Keywords: non-destructive method, FFCC, fuel debris, neutron, nuclear fuel materials
15:00 Poster panel: 223

Poster Number:
NSS-01-223

Development and Validation of Neutron Diagnostics on ASP in Support of Future Facilities (#1227)

L. A. Wilson1, C. Horsfield1, A. Leatherland1, G. Davies1, T. Harrington1, S. Morley1, S. Rice1, S. Tanner1, A. Stott1, A. Simons1, W. Tominey1, V. Woolhead1, D. Wright1

1 AWE - Nuclear Security Technologies, Reading, United Kingdom

Abstract

The ASP neutron facility at AWE – Nuclear Security Technologies (AWE-NST) Aldermaston, is undergoing upgrades to both the accelerator beamline and the supporting diagnostics.  This is driven by evolving customer requirements, particularly its increasing use as a platform for fundamental nuclear data measurements. Neutron flux monitoring on ASP is provided by fission chambers and is supported by external activation foil calibrations and internal cross-calibration measurements. A recommissioned associated-particle technique provides improved accuracy for lower-fluence measurements, while ongoing work is improving neutron spectral characterisation using a range of techniques including activation, Single crystal chemical vapour deposited diamond detectors, proton recoil and Helium - 3 spectrometers. These activities reduce uncertainties in current measurements, and establish the diagnostic techniques required for a future facility (VENTURE) capable of delivering higher fluxes and a wider range of quasi-monoenergetic neutron energies. The calibration and diagnostics strategy for the VENTURE facility is outlined, with an emphasis on delivering the well characterised source required for nuclear data experiments.

UK Ministry of Defence © Crown owned copyright 2026/AWE

Keywords: neutron diagnostics, accelerator neutron sources, neutron flux measurement, neutron spectroscopy, facility diagnostics
15:00 Poster panel: 225

Poster Number:
NSS-01-225

Development and test of a novel neutron and gamma imaging detector (#1280)

Y. Yu1, Y. Liu3, X. Liu1, Z. Qiao1, N. Jiang1, Q. Wei3, Y. Liu2

1 Chengdu Novel Medical Equipment Ltd., Chengdu, China
2 Tsinghua University, Beijing, China
3 University of Science and Technology Beijing, Beijing, China

Abstract

As the demand for the detection of special nuclear materials increases, the use of imaging instruments that can sensitively image both gamma-ray and neutron signatures has become necessary. The radioactive waste streams can contain neutron-emitting  radioactive materials, hence localisation of neutron sources plays an important part in nuclear decommissioning. Neutron detector design based on the MURA revealed promising results when tested in security applications. Due to the requirement of ensuring high detection efficiency for both neutrons and gamma rays, the plastic scintillator used is typically thick. As demonstrated in our previous study, the dual-layer design exhibits better imaging performance and produces fewer artifacts. In this paper, we propose a dual-layer DOI (depth of interaction) detector design and have successfully developed a prototype module. The first and second layer of the crystals are clearly resolved from the flood histograms, demonstrating its capability to provide two-layer depth encoding. The energy resolution of each layer is improved by 50% compared with that of a single-layer detector with the same thickness, and the neutron/gamma discrimination figure of merit (FOM) is also significantly enhanced. Validation and testing of the imaging performance are currently underway.

Keywords: depth of interaction detector, coded aperture, neutron and gamma imaging, energy resolution, pulse shape discrimination
15:00 Poster panel: 227

Poster Number:
NSS-01-227

Multilayer Scintillator for Improved Gamma-ray Discrimination at Thermal Neutron Scattering Beamlines (#1365)

A. Moustafa1, M. Loyd1

1 Oak Ridge National Laboratory, Oak Ridge, Tennessee, United States of America

Abstract

Scintillator-based thermal neutron detectors are utilized at scattering beamline facilities around the world. The Anger camera is one example that was designed and deployed at Oak Ridge National Laboratory. The camera uses enriched 6Li-glass (GS20) that offers advantages over the widely used 3He gas proportional counters, including sub-millimeter spatial resolution, higher count rate capability, and high neutron absorption efficiency. However, GS20 has higher γ-ray sensitivity due to its solid state, potentially reducing the neutron signal to background ratio. Gamma rejection using pulse height discrimination is feasible, but it suffers when there is greater overlapping between the neutron and gamma spectral features in intense background fields, like with certain beamline configurations. Additionally, pulse shape discrimination is unfeasible with GS20. Previous work demonstrated a new approach to discrimination by optimizing the scintillator shape and reducing its size. In this work, we demonstrate improved gamma discrimination by segmenting the GS20 scintillator layer of the Anger camera. The layer is divided into several thinner layers with the same overall thickness, and coupled together using non-scintillating quartz layers. The neutron absorption products fully deposit their energy in the GS20 layers due to their significantly shorter range compared to the Compton-scattered electrons from γ-rays that only partially deposit their energy. This allows for better separation between the respective features on the pulse height spectrum, and therefore improved discrimination, while maintaining the same high neutron absorption efficiency.

AcknowledgmentThis work was sponsored by the U.S. Department of Energy (DOE) Office of Science Early Career Research Program Award (KC0406021) under Contract No. DE-AC05- 00OR22725.
Keywords: Neutron detectors, Scintillation detectors, Gamma discrimination
15:00 Poster panel: 229

Poster Number:
NSS-01-229

Feasibility of Organic Scintillator-Based Coincidence Counting for Photonuclear Nondestructive Assay of Nuclear Materials (#1414)

K. Tanabe1, H. Sagara2, T. Katabuchi2, K. Terada3, Y. Takahashi3, J.-I. Hori3, K. Kiatkongkaew2, R. Kunitomo2

1 National Research Institute of Police Science, Physics Section, Chiba, Japan
2 Institute of Science Tokyo, Laboratory for Zero-Carbon Energy, Tokyo, Japan
3 Kyoto University, Institute for Integrated Radiation and Nuclear Science, Osaka, Japan

Abstract

This study demonstrates organic scintillator-based neutron coincidence counting as a promising approach for photonuclear nondestructive assay (NDA) of nuclear materials. Four organic scintillators—organic glass scintillator (OGS), EJ-276D, stilbene, and BC-501A—were systematically evaluated in terms of fast-neutron detection efficiency, pulse shape discrimination (PSD) capability, and timing response. In addition, three-detector coincidence counting systems based on OGS and stilbene detectors were constructed and tested using a 252Cf source. Stilbene and BC-501A exhibited excellent PSD performance, EJ-276D showed high fast-neutron detection efficiency, and OGS provided superior timing response. The OGS-based system successfully measured neutron double- and triple-coincidence events with and without lead shielding, whereas the stilbene-based system showed a marked reduction in coincidence events under unshielded conditions. These results indicate that combining PSD, neutron coincidence counting, and gamma-ray shielding enhances the extraction of correlated neutron signals in photonuclear NDA. The proposed OGS-based approach is a promising for active interrogation systems in nuclear security and safeguards.

Acknowledgment

This work was supported by JSPS KAKENHI Grant Number JP25K01706.

References
[1] K. W. Chin, H. Sagara, C. Y. Han, “Application of photofission reaction to identify high-enriched uranium by bremsstrahlung photons”, Annals Nuclear Energy, 158, 108295, (2021).
[2] K. Tanabe, H. Sagara, “A novel method of neptunium-237 detection in its separated form and advanced fuel based on photonuclear reactions”, Annals of Nuclear Energy, 170, 108990, (2022).
[3] K. Tanabe, H. Sagara, “Feasibility of americium detection and verification based on photonuclear reactions”, Annals of Nuclear Energy, 227, 112005, (2026).
[4] A.J. Jinia, T.E. Maurer, C.A. Meert, O.V. Pakari, S.D. Clarke, H.S. Kim, D.D. Wentzloff, and S.A. Pozzi, “Prompt Photofission Neutron Detection in Depleted Uranium”, Phys. Rev. Applied, 19, 054073, (2023).
[5] O. Searfus, C. Meert, S. Clarke, S. Pozzi, and I. Jovanovic, “Detection of uranium-photofission neutrons with a 4He scintillation detector”, Phys. Rev. Applied, 22, 064080, (2024).
[6] K. W. Chin, H. Sagara, J. Hori, Y. Takahashi, “Measurement System Requirements for Photofission Signal Detection with Coincidence Neutron Counting Method”, Progress Nuclear Science Technology, 7, 91-96, (2025).
Keywords: Coincidence counting, Neutron detection, Non-destructive assay, Nuclear security, Photonuclear reaction
15:00 Poster panel: 231

Poster Number:
NSS-01-231

Localization of uranium samples in large cemented nuclear waste using active photon interrogation and a Bayesian inversion (#1492)

M. Lebreton1, B. Geslot1, C. Carasco1, B. Pérot1, C. Michelet2

1 Commissariat à l'énergie atomique et aux énergies alternatives, CEA/DES/IRESNE, St Paul Lez Durance, France
2 Université de Bordeaux, CNRS-IN2P3/LP2IB, Bordeaux, France

Abstract

CEA Cadarache currently manages over 6,000 historical 870 L nuclear waste packages. To ensure long-term safety, French regulatory authorities require a precise characterization of each unit, specifically regarding structural integrity, fissile material mass and total activity of alpha emitters. However, the high density and volume of 870 L concrete waste packages result in significant signal attenuation, making standard passive gamma spectrometry or passive and active neutron measurements inefficient to assess the mass of nuclear materials. To maximize the signal-to-noise ratio, a specific Active Photon Interrogation (API) approach is developed inside the CINPHONIE irradiation bunker of CHICADE facility, at CEA IRESNE, Cadarache, France. This method makes use of inorganic BGO scintillators to measure high-energy delayed gamma rays from short-lived photofission products induced with a high-energy bremsstrahlung photon source, i.e., a 18 MeV LINAC. A Bayesian framework is applied to infer both the mass and the position of nuclear materials from angular acquisitions. This article is focused on testing API framework in the case where the source of the signal is located in a homogeneous environment. Based on the promising results presented here, future developments will focus on the heterogenous case.

References
[1] M. Lebreton et al., “Photon flux characterization of a new electron LINAC in the CINPHONIE irradiation facility through a Bayesian framework,” IEEE Trans. Nucl. Sci., pp. 1–1, 2026, doi: 10.1109/TNS.2026.3653194.
[2] M. Delarue et al., “Localization of nuclear materials in large concrete radioactive waste packages using photofission delayed gamma rays,” EPJ Web Conf., vol. 253, p. 08003, 2021, doi: 10.1051/epjconf/202125308003.
[3] C. Carasco et al., “Photofission delayed gamma-ray measurements in a large cemented radioactive waste drum during LINAC irradiation,” Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip., vol. 1053, p. 168360, Aug. 2023, doi: 10.1016/j.nima.2023.168360.
[4] C. Carasco, “A Bayesian approach for measuring nuclear material in radioactive waste using photofission,” Nucl. Instrum. Methods Phys. Res. Sect. Accel. Spectrometers Detect. Assoc. Equip., vol. 1057, p. 168728, Dec. 2023, doi: 10.1016/j.nima.2023.168728.
[5] “Home,” FASTER. Accessed: Jan. 22, 2026. [Online]. Available: https://faster.in2p3.fr/
Keywords: Active Photon Interrogation, Inorganic scintillators, LINAC, Waste characterization, Bayesian inversion
15:00 Poster panel: 233

Poster Number:
NSS-01-233

Development and Performance Evaluation of a Four-Detector RMS in Compliance with IEC 60532 (#1540)

D. Yang1, S.-H. Lee1

1 Korea Atomic Energy Research Institute (KAERI), Radiation Safety Management Division, Daejeon, Republic of Korea

Abstract

Radiation monitoring systems (RMS) are essential for continuous radiation surveillance and rapid alarm generation in nuclear facilities. This paper presents the development and performance evaluation of a miniaturized Local Processing and Display Unit (LPDU)-based RMS designed to reduce installation space and radioactive waste generation while maintaining reliable monitoring performance. The developed RMS adopts a 1:4 architecture that enables a single LPDU to process and display signals from four independent detectors. The system was implemented using a Texas Instruments TMS2800137-based edge device and a Canberra G64IC detector. Firmware was developed to support pulse counting, EEPROM operation, RS-232/RS-485 communication, and real-time data processing. A dedicated communication protocol with Cyclic Redundancy Check (CRC) verification was also implemented to enhance data integrity. In addition, a Centered Significant Test (CST)-based adaptive filtering algorithm was embedded in the edge device to improve noise suppression and detector signal monitoring under field conditions. Performance verification tests were conducted in accordance with IEC 60532:2010 using a calibrated Cs-137 gamma radiation source. The developed RMS satisfied the acceptance criteria for linearity, statistical fluctuations, response time, and alarm response time and stability. The maximum linearity deviation was 2.1%, the coefficient of variation was 0.0203%, and all response times were below 6 s. These results demonstrate that the proposed RMS provides reliable radiation monitoring performance in a compact multi-detector configuration.

AcknowledgmentThis work was supported by Korea Atomic Energy Research Institute (KAERI) R&D Program (No. 522430-26)
References
[1] S. H. Lee and D. A. Yang, “Development of a Low-cost Radiation Monitor with Quadruple Detectors,” in Proc. Korean Nuclear Society Autumn Meeting, 2025.
Keywords: Radiation monitoring system (RMS), Local Processing and Display Unit (LPDU), IEC 60532, gamma radiation monitoring
15:00 Poster panel: 235

Poster Number:
NSS-01-235

Template-Matching Position Solving on FPGAs for a Thermal Neutron Detector (#1591)

M. Loyd1

1 Oak Ridge National Lab, Oak Ridge, Tennessee, United States of America

Abstract

Silicon photomultiplier (SiPM) based thermal neutron detectors have been developed at Oak Ridge National Laboratory for single crystal diffraction instruments. They have potential as good replacements for current 3He detectors on neutron reflectometers due to their high spatial resolution and fast scintillator decay time. The current software-implemented position fitting on these detectors is limited due to the processing required for the recursive least-squares algorithm. In this work, we present a fast method for determining neutron position that can be run on the Field-Programmable Gate Array (FPGA) chip that is already installed on the detector. This method compares the collected event data with pre-determined shapes stored on FPGA memory in parallel, and determines the one with the least linear error. Using this method for neutron positioning takes less time than the hardware defined dead time. Count-rate and spatial resolution results collected at the High-Flux Isotope Reactor are presented, with output count rates > 500 kcps achieved, an order of magnitude greater than the software fitting method.

AcknowledgmentNotice: This summary has been authored by UT-Battelle, LLC, under contract DE-AC05-00OR22725 with the US Department of Energy (DOE).The US government retains and the publisher, by accepting the article for publication, acknowledges that the US government retains a nonexclusive,paid-up, irrevocable, worldwide license to publish or reproduce the published form of this manuscript, or allow others to do so, for US government purposes.DOE will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan. This work was sponsored by the U.S. Department of Energy (DOE) Office of Science Early Career Research Program Award (KC0406021) under Contract No. DE-AC05-00OR22725
Keywords: Neutron Detection, SiPM, FPGA
15:00 Poster panel: 237

Poster Number:
NSS-01-237

Method for determining lithium ore’s grade based on photoneutrons’ lifetime measurement (#1637)

M. Yu1, 2, Y. Yang1, 2

1 Tsinghua University, Department of Engineering Physics, Beijing, China
2 Tsinghua University, Key Laboratory of Particle & Radiation Imaging, Beijing, China

Abstract

Analysis of lithium ore grade is industrially significant for efficient lithium resource development and utilization, enabling improved production efficiency and reduced costs. Lithium has a large neutron absorption cross-section, and changes in lithium grade can affect the neutron lifetime, which is inversely proportional to the macroscopic absorption cross-section of ore. In this paper, a method for determining lithium grade through neutron lifetime measurements based on an e-LINAC driven photoneutron source is applied to the online analysis of lithium ore grade. Since lithium does not emit gamma rays upon neutron absorption, the neutron lifetime is measured from the time distribution of capture gamma rays induced by neutrons in the matrix elements of the medium. The feasibility of this approach has been demonstrated in experiments using various lithium nitrate solutions as simplified media. Meanwhile, the effect of neutron diffusion was investigated by simulations. The potential of neutron-induced prompt gamma analysis for reducing interference caused by variations in matrix composition is discussed. Further simulation studies and system design are in progress.

AcknowledgmentThis research was supported by the Natural Science Foundation of Beijing, China (Grant No. L252023).
References
[1] X. Zeng et al., “Commercialization of Lithium Battery Technologies for Electric Vehicles,” Advanced Energy Materials, vol. 9, no. 27, p. 1900161, Jun. 2019, doi: https://doi.org/10.1002/aenm.201900161.
[2] N Eswara Prasad, Amol Gokhale, and R J H Wanhill, Aluminum-Lithium Alloys : Processing, Properties, and Applications. Amsterdam: Elsevier Science, 2014. pp. 503–535.
[3] Dou L R, Liu H Q, Chang D K, et al. Challenges and countermeasures for lithium resources in China and analysis of global distribution and industry status. Bulletin of Chinese Academy of Sciences, 2025, 40(3): 494-510, doi: 10.16418/j.issn.1000-3045.20240326001.
[4] M. G. Aylmore et al., “Assessment of a spodumene ore by advanced analytical and mass spectrometry techniques to determine its amenability to processing for the extraction of lithium,” Minerals Engineering, vol. 119, pp. 137–148, Apr. 2018, doi: https://doi.org/10.1016/j.mineng.2018.01.010.
[5] C. Korbel et al., “Quantification of lithium using handheld instruments: application of LIBS and XRF spectroscopy to assay the lithium content of mineral processing products,” Journal of Analytical Atomic Spectrometry, vol. 39, no. 7, pp. 1838–1853, 2024, doi: https://doi.org/10.1039/d3ja00423f.
[6] Y. Liu, Y.-G. Yang, Y. Tai, and Z. Zhang, “A capture-gated fast neutron detection method,” Chinese Physics C, vol. 40, no. 7, p. 076201, Jun. 2016, doi: https://doi.org/10.1088/1674-1137/40/7/076201.
[7] J. S. Wahl, W. B. Nelligan, A. H. Frentrop, C. W. Johnstone, and R. J. Schwartz, “The Thermal Neutron Decay Time Log,” Society of Petroleum Engineers Journal, vol. 10, no. 04, pp. 365–379, Dec. 1970, doi: https://doi.org/10.2118/2252-PA.
[8] M. Yu, Y. Yang, C. Zong, and S. Ming, “Analysis of gadolinium concentration in solutions based on photoneutrons’ lifetime measurement,” Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment, vol. 1079, pp. 170661–170661, May 2025, doi: https://doi.org/10.1016/j.nima.2025.170661
Keywords: Lithium Grade Analysis, Neutron Lifetime, Photoneutron Source
15:00 Poster panel: 239

Poster Number:
NSS-01-239

EJ309-Based Neutron–Photon Detection for Photoneutron Characterisation and High-Altitude Radiation Assessment (#1848)

K. Al Khouri1, M. Bony1, V. Blideanu1, B. Rapp2

1 Université Paris-Saclay, Laboratoire National Henri Becquerel at CEA, Paris, France
2 Université Paris-Saclay, IRFU at CEA, Paris, France

Abstract

This work presents an EJ309 organic liquid scintillator system for neutron–photon detection in mixed radiation fields. The performances achieved are illustrated through two complementary use cases. The first concern photoneutron production in pulsed high-energy photon fields generated by a TrueBeam medical electron LINAC and it has been used to characterise neutron–photon pulse-shape discrimination, integrated-charge observables, pile-up and saturation signatures, and the response of the acquisition chain under short intense irradiation pulses. This configuration simulates closely enough the energies involved in high-altitude cosmic-ray neutron production allowing the use of the previously qualified detection system to be used for neutron monitoring at the Jungfraujoch research station (Switzerland, at 3600 m), where the neutron field is mainly produced by atmospheric secondary cascades, including proton- and alphainduced spallation reactions. The detection set-up and analysis framework will be used to measure time-resolved neutron-like and photon-like event populations, pulse-shape discrimination distributions, and spectral observables over long acquisition periods. The work demonstrates the use of EJ309 scintillators for fast-neutron detection in controlled photoneutron fields and supports their application to natural high-altitude cosmic-ray environments, atmospheric radiation monitoring, and photoneutron studies relevant to intense high-energy photon fields.

References
[1] A. Tomanin, J. Paepen, P. Schillebeeckx, R. Wynants, R. Nolte, A. Lavietes, “Characterization of a cubic EJ-309 liquid scintillator detector” in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 756, 2014, ISSN 0168-9002, https://doi.org/10.1016/j.nima.2014.03.028.
[2] C. Besnard-Vauterin, B. Rapp, V. Blideanu, “New Measurements of Photoneutron Spectra investigating specific signatures of Carbon, Nitrogen, and Oxygen” in Radiation Physics and Chemistry, vol. 229, 2025, ISSN 0969-806X, https://doi.org/10.1016/j.radphyschem.2025.112566
[3] C. Besnard-Vauterin, B. Rapp, V. Blideanu, “Neutron detection in mixed short-pulsed fields with intense photon flashes for LINAC-based active interrogation applications” in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 1064, 2024, ISSN 0168-9002, https://doi.org/10.1016/j.nima.2024.169403.
Keywords: atmospheric radiation, liquid scintillators, medical linear accelerator, neutron spectrometry, photoneutrons.
15:00 Poster panel: 241

Poster Number:
NSS-01-241

Multimodal extension of the Feynman model for thermal neutron multiplicity counters (#1916)

G. Chartier1, J. Dumazert1, B. Laurent1, L. Cavallini1, M. Labalme2

1 Commissariat à l'Énergie Atomique, DAM, DIF, Arpajon, France
2 LPC Caen, Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, Caen, France

Abstract

The point kinetics model can be extended to multiple regions or energy groups to account for system heterogeneities. This paper presents an extension of the Feynman-α technique in diverse measurement configurations relevant to nuclear safeguards. This extension is achieved by incorporating phase-type distributions into the heuristic derivation of the Feynman model. Phase-type distributions effectively capture the absorption times of finite-state Markov processes. The resulting expressions are specifically tailored to each experimental configuration. In a bare source configuration using an array of ³He-filled proportional counters, the neutron decay exhibits bimodal behavior. When a supplementary reflector is added to the setup, a third term emerges in the expression, as expected. However, the shape of this additional term depends on the type of reflector, due to assumptions in the system’s transition matrix. When fitted to simulated datasets, these new models show the fundamental decay mode of the detector (approximately 70 µs) and are validated with a 95% confidence χ2 test.

References
[1] Chartier, G., Denis-Petit, D., Aubert, D., Lavallou, F., Dufour N., Laurent, B., Lelaizant, G., Dumazert, J. 2026, ‘Bayesian calibration of the Feynman-Y technique for correlated neutron source characterization’, Annals of Nuclear Energy, Vol. 231, 112211.
[2] Feynman, R. P., de Hoffmann, F., Serber, R. 1956, ‘Dispersion of the neutron emission in U-235 fission’, Journal of Nuclear Energy, Vol. 3, pp. 64–69.
[3] Chernikova, D., Ziguan, W., Pázsit, I., Pál, L., 2014, ‘A general analytical solution for the variance-to-mean Feynman-alpha formulas for a two-group two-point, a two-group one-point and a one-group two-point cases’, European Physics Journal Plus, Vol. 129, 259.
[4] Hua, M., Hutchinson, J., McKenzie, G., Clarke, S., Pozzi, S., 2021, ‘On the Feynman-α method for reflected fissile assemblies’, Annals of Nuclear Energy, Vol. 155, 108082.
[5] Mogens, B., 2005, ‘A Review on Phase-type Distributions and their Use in Risk Theory’, ASTIN Bulletin, Vol. 35, pp.145–161.
[6] Furuhashi, A., Izumi, A., 1968, ‘Third moment of the number of neutrons detected in short time intervals’, Journal of Nuclear Science and Technology, Vol. 5, pp. 48–59, 1968.
Keywords: Neutron noise, Feynman-α, Markov processes, Phase-type distributions
15:00 Poster panel: 243

Poster Number:
NSS-01-243

Building a Two-Stage Compton Camera with LaBr3:Ce Detector Assemblies (#1962)

S. Hart1, P. Jones1, S. Mashinini4, L. Pellegri3, C. van Tubbergh2

1 iThemba LABS, Separated Sector Cyclotron Laboratory, Cape Town, South Africa
2 iThemba LABS, Research and Development Technical Support, Cape Town, South Africa
3 University of the Witwatersrand, School of Physics, Johannesburg, South Africa
4 Stellenbosch University, Cape Town, South Africa

Abstract

A two-stage Compton camera prototype was developed for compact gamma-ray imaging applications in medicine [1]. Each camera layer consists of four monolithic 14 × 14 × 25.4 mm3 LaBr3:Ce scintillation detector assemblies manufactured by CapeScint, each coupled to a single-channel silicon photomultiplier (SiPM) readout. This configuration does not provide intrinsic position sensitivity within individual crystals.

Detector performance was experimentally characterised and modelled using the TOPAS Monte Carlo toolkit, with validation performed against standard gamma-ray calibration sources [2]. Data acquisition was performed using a XIA PIXIE-16 fully digital signal processing system operating in list-mode, enabling event-by-event energy and timing extraction with digital pulse processing [3]. The detectors achieved an energy resolution of approximately 3.4% at 662 keV and a coincidence timing resolution of 988(17) ps.

Imaging performance was evaluated using a GBq 137Cs source at multiple source-to-detector distances. Reconstructed experimental images were compared with validated simulations, with simulations yielding a full width at half maximum (FWHM) of 3.36(1) mm and an angular resolution measure (ARM) of 1.47(13)o.

Results demonstrate agreement between experiment and simulation, validating the modelling framework and supporting the feasibility of compact LaBr3:Ce-based Compton camera systems for medical gamma-ray imaging applications.

AcknowledgmentThis work is based on the research supported wholly by National Research Foundation of South Africa (90741, 99037, 127116) and iThemba LABS.
Supported 2023-24 by the Technology Innovation Agency under Grant number 14606/01
References
[1] Hart, S, Jones, P, Pellegri, L, Peterson, S 2025, ‘Building a Hybrid Compton Camera System for Improving Medical Imaging Applications’, IEEE NSS MIC RTSD, DOI: 10.1109/NSS/MIC/RTSD57106.2025.11287197, USA: IEEE.
[2] TOPAS MC Inc, 2022, ‘TOPAS: A Tool for Particle Simulation’, TOPAS Monte Carlo, Available: http://www.topasmc.org/, USA: TOPAS MC Inc.
[3] XIA LLC 2019, ‘Pixie-16 User Manual’, XIA LLC, Available: https://docs.frib.msu.edu/daq/newsite/pixie16/Pixie16_UserManual.pdf, Accessed: 12-03-2024, USA: XIA LLC.
Keywords: Compton camera, gamma-ray imaging, silicon photomultiplier (SiPM), Monte Carlo simulation, Scintillation detector
15:00 Poster panel: 245

Poster Number:
NSS-01-245

Dosimetry and Beam-Condition Characterization of Mixed-Field Irradiation Positions at CERN CHARM (#2131)

S. Fiore1, F. Ravotti1, S. Danzeca1

1 CERN, Geneva, Switzerland

Abstract

Mixed-field irradiation facilities require accurate and traceable dosimetry to support the qualification of electronic components and systems for accelerator environments. This work presents an updated dosimetry and beam-condition characterization of the CERN High-energy AcceleRator Mixed-field facility (CHARM), focusing on the comparison of different irradiation positions and on the extension of the available test conditions to new high dose-rate and high fluence locations close to the target. The study combines active and passive dosimetry methods, including CERN RadMon radiation monitors, radiophotoluminescent glass dosimeters and alanine dosimeters, to evaluate Total Ionizing Dose and fluence-related quantities under representative operating conditions. Measurements acquired during commissioning are compared with data collected during user operation to assess the stability and reproducibility of the delivered radiation fields. In addition, the effect of upstream IRRAD samples on the residual beam reaching the CHARM target is investigated using the IRRAD beam position monitors and the multi-wire proportional chamber installed at the end of the T8 beam line. Variations in the upstream material configuration are shown to affect the transported beam properties, including divergence, with a measurable impact on the resulting mixed field. The combined dosimetry and beam instrumentation data are used to validate the new irradiation positions, compare independent dosimetry techniques and define operational reference conditions for CHARM tests. These results improve the traceability of dose and fluence delivery in mixed-field accelerator irradiation campaigns and support more robust interpretation of radiation effects tests performed at CHARM.

Keywords: Dosimetry, mixed radiation fields, radiation monitoring, irradiation facility characterization, beam instrumentation
15:00 Poster panel: 247

Poster Number:
NSS-01-247

Hybrid Temperature Compensation and Radiation Damage Recovery with Scintillation Detectors (#2243)

D.Y. Oh1, 2, J. Hwang1, 2, G. Kim1, 2, C. Kim3, J.-Y. Yeom1, 4

1 Korea University, Department of Bioengineering, Seoul, Republic of Korea
2 Korea University, Interdisciplinary Program in Precision Public Health, Seoul, Republic of Korea
3 Korea Atomic Energy Research Institute, Daejeon, Republic of Korea
4 Korea University, School of Biomedical Engineering, Seoul, Republic of Korea

Abstract

Gamma-ray spectroscopy is a fundamental technique for identifying radioisotopes in safety-critical applications. However, in scenarios such as nuclear accidents, high-temperature and high-radiation environments severely degrade photomultiplier tube performance. Conventional temperature compensation systems face physical voltage limits, and prior deep-learning algorithms fail because they require preserved spectral shapes. To overcome these limitations, this study presents a comprehensive strategy to enhance detector stability. First, an active high-voltage control system mitigates initial temperature-induced gain loss. Because this hardware compensation eventually reaches its physical safety limits, the system integrates a deep learning (DL) technique – bidirectional long short-term memory network – to interpret residual spectral distortions, successfully achieving accurate multi-isotope quantification up to 185 °C. Second, to address radiation-induced damage localized within the photomultiplier tube, a targeted active thermal annealing protocol was applied. Following a 1.55 kGy cumulative gamma irradiation, detector output dropped to 23.5% of its baseline. Subsequent thermal annealing of the photomultiplier tube body at 145 °C successfully restored the output to 89.4%. Ultimately, this integration of hardware, software, and active recovery lays a foundation for robust radionuclide identification under concurrent high-temperature and high-radiation constraints.

References
[1] Park, M., Kim, C., Hwang, J., Yeom, J.-Y. 2026, ‘Deep learning-based radioisotope quantification for extreme environments’, Radiation Physics and Chemistry, 239, 113345, Amsterdam: Elsevier Ltd.
[2] Kim, C., Kim, D., Lee, Y., Park, C., Ullah, M. N., Kim, D., Kwon, I., Hur, S., Yeom, J.-Y. 2021, ‘Radiation resistance and temperature dependence of Ce:GPS scintillation crystal’, Radiation Physics and Chemistry, 183, 109396, Amsterdam: Elsevier Ltd.
Keywords: Active voltage control, gamma-ray spectroscopy, thermal annealing, bidirectional long short-term memory
15:00 Poster panel: 249

Poster Number:
NSS-01-249

Simulations of A Novel Time-of-Flight β/γ Transmission Tomography Scanner (#2255)

R. Carmichael1, 2, A. Chatziioannou1, 2

1 University of California Los Angeles, Department of Molecular and Medical Pharmacology, Los Angeles, California, United States of America
2 University of California Los Angeles, Crump Institute for Molecular Imaging, Los Angeles, California, United States of America

Abstract

Large cargo scanning presents a unique challenge for national security. Container size limitations pose challenges to tomographic imaging. This work proposes a new stationary, limited angle tomographic transmission scanner geometry with a unique β/γ source utilizing a pair of fixed flat panel detectors, known as Gamma Tomography (GT). A Gate 10 simulation evaluates the imaging capabilities of the scanner and explores time-of-flight (TOF) and energy discrimination as electronic collimation methods to reduce scattered radiation and improve image quality. A 600 μm thin plastic scintillator sheet encasing 100mCi of 60Co as a near detector locally captures nearly all emitted β particles without significant γ interactions, while a far detector panel of 2 cm thick LYSO crystals captures the ~1.25 MeV energy 60Co γ photons. Both panels were simulated as 50x80 cm with a thin, 2 cm thick, multi-material test object consisting of water, aluminum, titanium, steel, and uranium in the center of the field of view. The same simulation dataset was reconstructed with/without two separate electronic collimation schemes: valid coincidences with a 100 keV energy window around the 60Co photopeaks, and valid coincidences with a 100 ps time resolution. Despite the short acquisition time (18sec), reconstructed images are low noise, with all objects visible above background and distinguishable. The images show attenuation coefficient under-estimation, due to object scatter. TOF and energy discrimination underestimate μ values by 25.8% and 34.3% respectively, but a large dynamic range and very high SNR in μ value is achieved for all reconstructions (SNR-water: 46, SNR-Uranium: 1369). Using time information in lieu of energy allows events scattered in the detector to be used to improve image quality and SNR, but further investigation will include achievable time resolution, panel construction, and source geometry optimization.

Keywords: Time-of-flight, Transmission Tomography, PET, Cargo Scanning, μ-map
15:00 Poster panel: 251

Poster Number:
NSS-01-251

A Large-Area Spectroscopic Alpha Imaging Detector for Dual-Isotope Imaging of ²²⁵Ac and ²¹³Bi in Targeted Alpha Therapy (#2275)

J.-G. Kim1, B.S. Kim1, I. Lim1, K.C. Lee1

1 Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea

Abstract

Alpha particle autoradiography is an emerging modality for mapping the biodistribution of alpha-emitting radionuclides in preclinical studies, supporting the development of radiopharmaceuticals for targeted alpha therapy (TAT). Considerable effort has been directed toward achieving high spatial resolution, with recent advances emphasizing single-event processing and energy-resolved detection to identify the nuclide of origin of individual alpha particles. Our previous work validated a spectrum decomposition method for dual-isotope imaging of ²²⁵Ac and ²¹³Bi using a spectroscopic alpha imaging detector, confirming its feasibility with therapeutic amounts of ²²⁵Ac. However, the active area of that system was constrained to 2.5 cm × 2.5 cm, limiting its applicability to small fields of view. To overcome this constraint and accommodate simultaneous imaging of multiple tissue sections or organs from larger animals, we developed a large-area spectroscopic alpha imaging detector with an active area of 5 cm × 5 cm, representing a fourfold increase over the prior system. The detector achieved an energy resolution of 4.3% FWHM at 5 MeV and a spatial resolution of approximately 600 μm, representing a substantial improvement over the prior system. Future work will include demonstration of dual-isotope spectral imaging of ²²⁵Ac and ²¹³Bi to support preclinical TAT evaluations.

Keywords: dual-isotope imaging, Actinium-225, Bismuth-213, Large alpha imaging detector
15:00 Poster panel: 253

Poster Number:
NSS-01-253

Scintillator Size Effects in Fiber-Based Neutron Detectors With Pulse-Shape Discrimination for BNCT (#2328)

H.-D. Liu1, 2, C.-Y. Chang1, Y.-H. You1, Y.-C. Chang1, Z.-F. You2, T.-H. Lin1, M.-W. Lin1

1 National Tsing Hua University,, Institute of Nuclear Engineering and Science, Hsinchu, Taiwan
2 Heron Neutron Medical Corporation, Nuclear Science Department, Zhubei, Taiwan

Abstract

Scintillator-on-fiber (SOF) detectors utilizing Liglass scintillators show strong potential for neutron flux monitoring in intense radiation environments due to their high radiation hardness and fast response. Previous studies have typically employed fragmented scintillators in SOF detectors due to the difficulty of μm-scale machining. In this work, Li-glass scintillators with well-defined dimensions (1×1×0.5 to 0.25×0.25×0.5 mm3) were precisely fabricated using laser cutting, enabling a systematic investigation of the effect of scintillator size on neutron response linearity in an acceleratordriven neutron beam. With pulse-shape discrimination (PSD), the results show that neutron signals measured with scintillator sizes larger than 0.5×0.5×0.5 mm3 become blurred in the PSP -channel scatter plot due to gamma-ray contributions and pulse pile-up at an accelerator current of 250 μA. In contrast, the smallest scintillator (0.25×0.25×0.5 mm3) maintains clear separation between neutron and gamma-ray signals. Analysis of the maximum shift error σm of the neutron peak centroid further indicates that this smallest scintillator effectively suppresses pileup, achieving σm = 0. In terms of linearity, scintillators with sizes below 0.75×0.75×0.5 mm3 yield coefficients of determination R2 > 0.99 when processed using a two-dimensional fiducial cut, satisfying the requirements for neutron flux monitoring in boron neutron capture therapy (BNCT). These results demonstrate the feasibility of optimizing Li-glass scintillator size and volume in SOF detectors to achieve reliable neutron flux monitoring in BNCT applications.

AcknowledgmentThis work was primarily supported by Heron Neutron Medical Corporation and the Industry–Academia Cooperative Ph.D. Project of the Ministry of Education in Taiwan. Partial financial support was also provided by the Institute of Nuclear Engineering and Science at National Tsing Hua University. 
Keywords: optical fiber, scintillation detector, pulse shape discrimination, Li-glass, laser-cutting
15:00 Poster panel: 255

Poster Number:
NSS-01-255

Performance Evaluation of a DOI-Based Directional Radiation Monitoring System for Moving Radiation Source Tracking (#2334)

Y.S. Chung1, J. Kang1, J. Ra1, Y.H. Chung1

1 Yonsei University, Radiation Convergence Engineering, Wonju, Republic of Korea

Abstract

Radiation accident response requires real-time source-direction and radionuclide information. However, conventional systems are limited in simultaneously achieving radionuclide identification, direction estimation, 360° monitoring, real-time processing, and multiple-source detection. To address this, a directional radiation monitoring system (DRMS) using the depth-of-interaction (DOI) method was developed previously, and its feasibility for 360° monitoring and multiple-source detection was verified. This study evaluated the real-time direction detection performance of the developed DRMS under moving-source conditions. The DRMS consisted of a CsI(Tl) scintillator (1" diameter, 4" height), two photomultiplier tubes coupled to both ends, a cylindrical collimator with eight slots arranged in different directions, and an FPGA-based DAQ. The system calculated gamma-ray energy and DOI using the sum and ratio of the two PMT signals, respectively, and generated radiation distribution maps in real time based on the slot direction corresponding to the estimated DOI layer. Evaluation was conducted assuming an accident scenario in which a 5 TBq radiation source mounted on a vehicle moved at 40 km/h, 100 m from the system. To reproduce this in a laboratory, measurements used a 3.17 MBq 137Cs source moved at 4.23 cm/min, 1 m from the system, under the same count-rate condition. Energy windows were applied to the data, and the nuclide was identified when counts within its window satisfied the criterion. A nuclide distribution map updated at fixed count intervals to reflect the real-time source position and an accumulated distribution map reflecting the total response were generated. The results confirmed that the system could visually reflect the position change and movement trajectory of a moving source. These results demonstrate the potential of the DOI-based DRMS for real-time source-direction monitoring in radiation accident response and mobile radiation detection.

References
[1] International Atomic Energy Agency, Preparedness and Response for a Nuclear or Radiological Emergency: General Safety Requirements. in IAEA Safety Standards Series No. GSR Part 7, no. v. GSR Part 7. Vienna: IAEA, 2015.
[2] International Atomic Energy Agency, Generic Procedures for Assessment and Response During a Radiological Emergency, IAEA-TECDOC-1162. Vienna, Austria: IAEA, Aug. 2000 (emended version, Mar. 2013).
[3] Y. S. Chung, M. K. Baek, S. Lee, J. Kang, and Y. H. Chung, “A novel directional radiation monitoring system for real-time nuclide identification and source localization using DOI method,” Nuclear Engineering and Technology, vol. 57, no. 10, p. 103710, Oct. 2025, doi: 10.1016/j.net.2025.103710.
[4] Y. S. Chung, S. Lee, J. Kang, J. Ra, J. Lee, and Y. H. Chung, “Design optimization and validation of a DOI-based directional radiation monitoring system for real-time nuclide identification and source localization,” Nuclear Engineering and Technology, vol. 58, no. 7, p. 104265, Jul. 2026, doi: 10.1016/j.net.2026.104265.
Keywords: Directional radiation monitoring system, Depth of interaction, Moving source detection, Radionuclide identification, Real-time
15:00 Poster panel: 257

Poster Number:
NSS-01-257

Development of a Portable High-Gamma-Ray-resistant Alpha and Beta Dust Monitor (#2423)

M. Hirato1

1 Japan Atomic Energy Agency, Plutonium Radiation Control Section Radiation Protection Department, Muramatsu, Tokai-Mura, Naka-gun, Japan

Abstract

Measuring the radioactivity concentrations of airborne dust is crucial for selecting appropriate protective equipment for radiation workers and assessing internal exposure of them. In this study, we aim to develop a portable dust monitor that can measure alpha and beta rays simultaneously without being affected by ambient gamma rays. For the development, we utilize the clothing contamination monitor, which has been successfully put into practical use in previous research.
We investigated whether it was possible to distinguish between alpha and beta rays based on their respective energy spectra by irradiation tests. The results showed that by setting appropriate regions of interest (ROIs), we were able to minimize the influence of gamma rays and successfully distinguish and measure alpha and beta rays.

Acknowledgment

This work was supported by JAEA Nuclear Energy S&T and Human Resource Development Project Grant Number JPJA25P 25135771.

Keywords: Alpha/beta dust monitor, Phoswich detector, Gd2Si2O7 (GPS) scintil
15:00 Poster panel: 259

Poster Number:
NSS-01-259

Investigation of Structure-Dependent Neutron-Induced Displacement Damage in Silicon MOSFETs (#2564)

O. Jinseok1, 2, H. Seop2, K. Seo-Ryong2, K. Inyong3

1 Korea University of Science and Technology (UST), Daejeon, Republic of Korea
2 Korea Atomic Energy Research Institute (KAERI), Daejeon, Republic of Korea
3 Yonsei University, Wonju, Republic of Korea

Abstract

This work systematically characterizes how transistor geometry governs neutron displacement damage (DD)-induced degradation in silicon MOSFETs. A monolithic single-chip array integrating 1.8 V and 3.3 V NMOS/PMOS devices with seven channel widths and 1-, 5-, and 10-finger layouts was fabricated as the device under test, and a hierarchical 1 GHz multiplexing readout was developed to track 84 transistors in real time during irradiation at TRIUMF (10⁶–10¹⁰ n/cm², five incremental steps, annealing monitored up to 40 days). For 1.8 V NMOS devices, the post-irradiation output-voltage shift scaled with channel width, while the threshold-voltage shift after 40-day annealing varied strongly with finger configuration at the same total channel width. These results indicate a strong dependence of DD-induced degradation on finger topology, beyond what channel-width scaling alone can explain, with 10-finger layouts exhibiting anomalous nonlinearity attributable to parasitic coupling and non-uniform damage.

AcknowledgmentThis work was supported in part by the National Research Foundation (NRF) funded by the Korean government (MSIT) (RS-2025-04162969, RS-2022-00144324, RS-2022-00144419, and RS-2022-00165164), the Regional Innovation System & Education (RISE) program through the Gangwon RISE Center, funded by the Ministry of Education (MOE) and the Gangwon State (G.S.), Republic of Korea. (2025-RISE-10-006), the National Research Council of Science & Technology (NST) grant by the Korea government (MSIT) (No. GTL25051-000), and the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (RS-2026-00144324).
References
[1] J. R. Srour and J. W. Palko, “Displacement Damage Effects in Irradiated Semiconductor Devices,” in IEEE Transactions on Nuclear Science, vol. 60, no. 3, pp. 1740-1766, June 2013, doi: 10.1109/TNS.2013.2261316.
[2] H. J. Barnaby, “Total-Ionizing-Dose Effects in Modern CMOS Technologies,” in IEEE Transactions on Nuclear Science, vol. 53, no. 6, pp. 3103-3121, Dec. 2006, doi: 10.1109/TNS.2006.885952.
[3] F. Faccio and G. Cervelli, “Radiation-induced edge effects in deep submicron CMOS transistors,” in IEEE Transactions on Nuclear Science, vol. 52, no. 6, pp. 2413-2420, Dec. 2005, doi: 10.1109/TNS.2005.860698.
[4] E. Simoen et al., “Radiation Effects in Advanced Multiple Gate and Silicon-on-Insulator Transistors,” in IEEE Transactions on Nuclear Science, vol. 60, no. 3, pp. 1970-1991, June 2013, doi: 10.1109/TNS.2013.2255313.
Keywords: Neutron Displacement Damage (DD), CMOS Transistor Array, Layout-dependent effects
15:00 Poster panel: 261

Poster Number:
NSS-01-261

Solid-State Large-Area Contamination Detector Using Lightlink™ technology for Contamination and clearance equipment (#2688)

P. Talent1

1 Mirion Technologies, R&D, Lamanon, France

Abstract

This paper presents a solid-state detection technology designed to improve large-area surface contamination measurements and enable integration into contamination and clearance equipment or robotics.

The primary objective is to replace photomultiplier-based detectors with compact architecture using solid-state photosensors and embedded digital processing, while maintaining or improving detection performance.

The proposed detector consists of a 579cm² sensitive surface divided into two independent channels, each coupled to integrated electronics performing biasing, signal processing, self-test, and communication. A daisy-chain configuration was implemented to evaluate system scalability, allowing up to fifty detectors to operate synchronously within a single network. Measurements demonstrate detection homogeneity better than plus or minus fifteen percent over the active area and typical hemispherical efficiencies up to forty-six percent for high-energy beta emitters. The acquisition architecture enables rapid readout compatible with moving platforms, with sampling rates reaching one hundred measurements per second for moderate network sizes.

Compared with legacy systems, the proposed solution significantly reduces mass while improving robustness and insensitivity to magnetic fields and eliminates the need for complex external electronics. These results confirm that solid-state based large-area detectors can achieve high-performance contamination monitoring while enabling modular, scalable, and easily deployable systems. The approach opens new perspectives for robotic applications and large-area inspection in nuclear environments.

Keywords: Contamination detection, radiation detectors, solid-state photosensors., scintillator
15:00 Poster panel: 263

Poster Number:
NSS-01-263

Performance Evaluation of the SNIPER-GN Portable Gamma–Neutron Detection System (#2692)

P. Garosi1, F. Davolio1, C. Del Bene1, G. Mangiagalli1, M. Morichi1, C. Uguccioni1

1 CAEN S.p.A., Viareggio, Italy

Abstract

This work presents the experimental validation of SNIPER-GN, a portable gamma–neutron detection and identification system whose core innovation is a patented neutron identification algorithm (U.S. Patent No. 11835477). The algorithm enables robust and reliable neutron identification under challenging operational conditions, including shielding, moderation effects, and intense masking gamma radiation fields, representing a significant advancement over conventional detection approaches. The system integrates a high-efficiency gamma–neutron counter with a mid–high-resolution scintillation detector for rapid localization and characterization of radioactive threats, including Special Nuclear Material. The patented algorithm constitutes the enabling technology of the system and was the primary focus of the experimental verification campaign. Extensive performance testing was conducted in several international laboratories using calibrated sources under both static and dynamic measurement conditions. The system successfully identified neutron-emitting sources down to approximately 1 count per second with background levels below 0.1 counts per second, while gamma identification remained stable above 60 net counts per second over background. Tests employing polyethylene and lead shielding demonstrated identification success rates up to 100% depending on source geometry and activity, confirming robustness in realistic scenarios. Dynamic tests compliant with ANSI N42.53 confirmed reliable alarm performance for moving sources. Additional validation for field applications, such as rapid analysis of air-sampler filters and iodine cartridges for post-fallout monitoring, showed astonishing minimum detectable activities within measurement times shorter than five minutes.
Overall, these results validate the patented technology and demonstrate the suitability of SNIPER-GN for homeland security, emergency response, and radiological field deployment scenarios.

Keywords: Gamma spectroscopy, Neutron detection, Portable radiation detector, Radiation monitoring, Special Nuclear Material
15:00 Poster panel: 265

Poster Number:
NSS-01-265

Development of A Cold Neutron Imaging Detector based on Structured 10B2O3-ZnS:Cu Screen (#2717)

D. Li1, P. Zhang1, X. Yan1, H. Li1, B. Yuan1

1 China Institute for Radiation Protection, Taiyuan, China

Abstract

Neutron imaging plays an irreplaceable role in the restoration of cultural relics and the study of lithium battery charging and discharging behaviors. The performance of neutron imaging detector directly determines the imaging quality. A cold neutron imaging detector based on a structured 10B2O3-ZnS:Cu scintillation screen was developed and tested at China Mianyang Research Reactor (CMRR) Cold Neutron Radiography Facility. The structured screen was made of glass microchannel plate (MCP), B2O3, ZnS:Cu and UV-curable binders. The refractive index contrast between the MCP (1.5) and the UV curable adhesive(1.62) leads to total internal reflection, thereby forming a light confinement structure. The spatial resolution was measured to be about 33μm with a Siemens Star Chart, and the cold neutron absorption efficiency was measured to be 24.4%

AcknowledgmentThis work was supported by the National Natural Science Foundation of China (No.12175202).
References
[1] Li, Deyuan, et al. "Design Optimization and Characterization of Cold Neutron Imaging Detector Based on Novel Gadolinium Scintillation Glass Fiber Arrays and Infinity Corrected Optics." IEEE Transactions on Nuclear Science 69.10 (2022): 2162-2167.
[2] Li, De-Yuan, et al. "High spatial resolution cold neutron imaging with new Tb3+/Ce3+ co-doped Gd2O3 scintillation glass fiber arrays." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 949 (2020): 162829.
Keywords: Structured 10B2O3-ZnS:Cu Screen, Cold Neutron Imaging, High Spatial Resolution
15:00 Poster panel: 267

Poster Number:
NSS-01-267

Revealing Disorder Faster: Detector Upgrades for SANDALS-II (#2826)

S. E. Mann1, N. J. Rhodes1, E. M. Schooneveld1, G. Mauri1, J. Day1, O. L.G. Alderman1, T.-L. Hughes1, D. T. Bowron1, G.J. Sykora1

1 STFC, ISIS, Harwell Campus, United Kingdom

Abstract

SANDALS-II is an instrument being developed at the ISIS Neutron and Muon Source as a next generation diffractometer for the study of amorphous and liquid materials. This upgrade will deliver count rates up to 11 times higher than the existing SANDALS instrument and will significantly expand its scientific capabilities. This work focuses on developments of a large area scintillator detector that are essential for achieving enhanced performance. Scintillation detectors for SANDALS-II will cover a solid angle of 0.67Ω, 2.4 times greater detector coverage than the current instrument. These detectors are required to have high efficiency, particularly at higher neutron energies (short wavelengths), which is achieved using a unique design employing tiles made from alternating layers of glass and scintillator. Scintillator and glass options are explored to optimise detector and instrument performance. Different low Li and B content glasses were tested to determine the most suitable option for the instrument that provides good neutron transmission while maintaining affordability. The ratio of ZnS:Ag to 6LiF in the scintillator will be altered from 4:1 to 2:1 to enhance neutron absorption and therefore detection efficiency. At 30eV (0.05Å) this offers a 60% improvement in detection efficiency. The applicability of low-afterglow scintillator, ZnO:Zn/6LiF, for use in SANDALS-II is also explored. ZnO:Zn/6LiF is shown to offer a 2x increase in count rate capability over ZnS:Ag/6LiF, but a 6% lower neutron detection efficiency. As the reduction in efficiency using ZnO:Zn/6LiF is modest, this alternative scintillator offers a viable solution for the high count rate regions of SANDALS-II. With optimised glass and scintillator selection, the performance required for the upgraded instrument can be delivered. This will enable faster measurements, smaller sample studies, and time resolved experiments, making SANDALS-II a world leading disordered material neutron diffractometer.

Keywords: neutron scattering, detection efficiency, ZnS:Ag and ZnO:Zn, scintillation detectors, count rate capability
15:00 Poster panel: 269

Poster Number:
NSS-01-269

PGNAA-Based Composition Analysis Using LaBr₃(Ce) and NaI(Tl) Detectors (#2849)

K. Lee1, 2, H. Kim1, H. Ha1, K. Jung1, J. Eo2, J. Shin2, J. Kim3, J. Kim4, K. Oh4, J. Park4, C. Baek1, 5

1 Kangwon National University, Medical Health Science, Samcheok, Republic of Korea
2 3I Solution, Suwon, Republic of Korea
3 Korea Atomic Energy Research Institute, Neutron Science Center, Daejeon, Democratic People's Republic of Korea
4 Korea Atomic Energy Research Institute, Advanced Radiation Technology Institute, Jeongeup, Republic of Korea
5 Kangwon National University, Radiological Science, Samcheok, Germany

Abstract

This study evaluated the performance of a LaBr₃(Ce) scintillation detector for elemental identification and mass-fraction estimation in a thermal-neutron-based prompt gamma-ray neutron activation analysis (PGNAA) system, in comparison with a conventional NaI(Tl) detector. PGNAA spectra were acquired at the Four-Circle Diffractometer (FCD) beamline of the HANARO research reactor at the Korea Atomic Energy Research Institute. The measured samples included pure Mn, Fe, Co, and Ni samples; binary Fe–Mn, Fe–Co, and Fe–Ni mixtures; and ternary NCM622 and NCM811 samples simulating spent lithium-ion battery cathode materials. Elemental identification was performed using Gaussian-derivative-convolution-based peak detection, SNIP baseline correction, and Currie-criterion-based significance testing. Mass fractions were estimated using region-of-interest-based weighted non-negative least squares (WNNLS) with attenuation-integration correction. LaBr₃(Ce) produced higher Z-scores, smaller energy-matching errors, and more stable characteristic peak combinations in mixed samples than NaI(Tl). For NCM622 and NCM811, LaBr₃(Ce) achieved mean absolute errors of 4.3 and 1.9 percentage points, respectively, while also providing higher R² values for spectral-shape reproduction. These results indicate that LaBr₃(Ce) offers improved peak separation and compositional estimation capability for nondestructive analysis of complex industrial samples, including spent lithium-ion battery cathode materials.

AcknowledgmentThis work was supported by the Technology development Program(RS-2024-00469068) funded by the Ministry of SMEs and Startups(MSS, Korea)
References
[1] T. Gozani, M. Elsalim, D. Strellis, and D. Brown, 2003, “Fusion of time-dependent gamma production spectra from thermal neutron capture and fast neutron inelastic scattering to improve material detection”, Nucl. Instrum. Methods Phys. Res. A, vol. 505, no. 1–2, pp. 438–441, Elsevier.
[2] G. Molnár, 2004, “Handbook of Prompt Gamma Activation Analysis with Neutron Beams”, 1st ed., Dordrecht, Netherlands: Springer, pp. 244-291, Springer
Keywords: Lanthanum bromide detector, mass-fraction estimation, prompt gamma-ray neutron activation analysis, spent lithium-ion battery recycling.
15:00 Poster panel: 271

Poster Number:
NSS-01-271

Ultra High-Rate Neutron Detection with ³He Tubes via CF₄ Prompt Scintillation Readout (#3034)

L. M. Margato1, 2, A. Morozov1, 2, V. Solovov1, B. Guérard3, J. Marchal3

1 LIP-Coimbra, Coimbra, Portugal
2 University of Coimbra, Dep. of Physics, Coimbra, Portugal
3 ILL-Institut Laue-Langevin, Grenoble, France

Abstract

This work presents a novel neutron detector concept aiming to provide detection efficiency and background levels equivalent to conventional ³He-based detectors, whilst boosting the maximum counting rate by several orders of magnitude. The detector retains the form-factor of a standard ³He tube and uses the same working gas mixture of 3He with admixture of CF4 as the stopping gas. The key innovation is a fast optical readout of CF₄ prompt scintillation light using silicon photomultiplier (SiPM) sensors. The target performance is a detection efficiency equivalent to that of a standard ³He tube under identical gas filling conditions, gamma sensitivity below 10⁻⁶, and a maximum counting rate of 2 MHz/pixel, orders of magnitude improvement over existing detectors. The fast emission of CF₄ scintillation light is the enabling factor for achieving ultra-high counting rates. CF₄ exhibits a considerable photon yield, with one scintillation band in the UV and another in the visible region of the spectrum, with several thousands of photons emitted per neutron event. The efficient collection of light by the SiPMs constitutes a critical design parameter, addressed in this study through Monte Carlo optimization. The gas mixture composition is optimised to maximise the scintillation yield, and a gas purification system can be integrated into the detector to ensure long-term stability. The first experimental results of a detector prototype characterisation on a neutron beamline at the Institut Laue-Langevin (ILL) will be presented.

AcknowledgmentThis work was supported by the Portuguese national funds OE and Foundation for Science and Technology within the project Ref. 2023.15652.PEX (https://doi.org/10.54499/2023.15652.PEX). L. Margato acknowledges FCT-Portugal support through contract CEECINST/00106/2018/CP1494/CT0001.
References
[1] Morozov, A, et al., “Photon yield for ultraviolet and visible emission from CF4 excited with α-particles”, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol. 268, no. 9, pp. 1456–1459, May 2010
[2] Morozov, A, et al., “Effect of the electric field on the primary scintillation from CF4”, Nuclear Instruments and Methods in Physics Research A 628 (2011) 360
[3] Morozov, A, Margato, L, Canezin, G, and Gonzalez, J, “Ants3 toolkit: Front-end for Geant4 with interactive GUI and Python scripting”, Computer Physics Communications, vol. 318, p. 109869, Jan. 2026
[4] Margato, L, et al., “Effect of the gas contamination on CF4 primary and secondary scintillation”, Nuclear Instruments and Methods in Physics Research A 695 (2012) 425
Keywords: Thermal Neutron Detectors, Neutron Time-of-Flight Spectrometers, Optical readout, SiPMs, Large Scale Neutron Facilities
15:00 Poster panel: 273

Poster Number:
NSS-01-273

Imaging detection and spectral tracking of neutrons in wide range by Timepix detectors with Si, SiC, GaAs and CdTe sensors (#3044)

C. Granja1, A. Sagatova1, T. Slavicek2, S. Pospisil2, C. Oancea3, P. Alexa4, Z. Vykydal, Z. Vykydal5

1 Slovak University of Technology, Faculty of Electrical Engineering and Computer Science, Bratislava, Slovakia
2 Czech Technical University, Institute of Experimental and Applied Physics, Prague, Czech Republic
3 Advacam, Prague, Czech Republic
4 VSB-Tech. Univ. Ostrava, Faculty of Electrical Engineering and Computer Science, Ostrava, Czech Republic
5 Czech Metrology Institute, Prague, Czech Republic

Abstract

The response of Timepix detectors with different sensors (Si, SiC, GaAs, CdTe) to thermal, slow, and fast neutrons is studied. Measurements at tunable mono-energetic neutron fields are compared and analyzed with nuclear-reaction models and numerical calculations. Specific radiation-type and sensor-material interaction neutron detection channels are derived for each detector-sensor configuration. These results serve to better and more completely process radiation data acquired with these detectors. Combining multi-detector measurements expands and enhances the resolving power of field decomposition.

Acknowledgment

Work at the STU Bratislava was partially supported by grants APVV-22-0382 and DS-FR-24-0020 of the Slovak Research and Development Agency and funded by the EU NextGenerationEU through the Recovery and Resilience Plan for Slovakia under the project No. 09I05-03-V02-00073.

References
[1] C. Zeitlin, “Physical Interactions of Charged Particles for Radiotherapy and Space Applications”, Health Physics, vol. 103, pp. 540-546, 2012.
[2] E. H. Lehmann, et al., “Neutron imaging — Detector options in progress”, J. of Instrum. vol. 6, 2011, Art no. C01050.
[3] C. Granja, et al., “Detection of fast neutrons with the pixel detector Timepix3”, J. of Instrum., vol. 18, 2023, Art no. P01003.
[4] R. Ballabriga, et. al., “ASIC developments for radiation imaging applications: The medipix and timepix family”, Nucl. Instrum. Meth. A, vol. 878, pp. 10-23, 2018R. Ballabriga, et. al., “ASIC developments for radiation imaging applications: The medipix and timepix family”, Nucl. Instrum. Meth. A, vol. 878, pp. 10-23, 2018.
[5] C. Granja, et al, "Detection resolving power of SiC Timepix3 detector to electrons, neutrons, ions and protons", J. of Instrum. vol. 19, 2024, Art no. C11007.
[6] J. Jakubek, S. Pospisil, et al., "Neutron detector based on TimePix pixel device with micrometer spatial resolution", Proc. SPIE 7449, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XI, 2009, Art no. 744910.
[7] C. Granja, et al., “Composition and Spectral Characterization of Mixed-Radiation Fields with Enhanced Resolving Power by Quantum Imaging Detection and Spectral-Sensitive Particle Tracking”, IEEE Trans. Nucl. Sci., vol. 71, 2024, Art no. 921-931.
[8] B. Bergmann, S. Pospisil, et al., “Ionizing Energy Depositions After Fast Neutron Interactions in Silicon”, IEEE Trans. Nucl. Sci. vol. 63, 2016, Art no. 2372-2378.
[9] C. Granja, et al., “Resolving power of pixel detector Timepix for wide-range electron, proton and ion detection”, Nuclear Instr. Methods A, vol. 908, 2018, Art no. 60-71.
Keywords: Neutron detection, radiation imaging, particle tracking, semiconductor pixel detectors
15:00 Poster panel: 275

Poster Number:
NSS-01-275

Characterization of 3D ultra-thin silicon-based thermal neutron detectors (#3088)

F. Zamorano1, I. Lopez1, M. Pérez1, J. Bravo1, C. Fleta1, C. Guardiola1

1 Institute of Microelectronics of Barcelona, Barcelona, Spain

Abstract

Neutron contamination in advanced radiotherapy and other mixed radiation environments has become an increasing concern due to the limitations of conventional neutron detectors under intense gamma background conditions. In this work, ultra-thin 3D silicon neutron detectors specifically designed for operation in mixed radiation fields were experimentally characterized under thermal and high-energy irradiation conditions. The detectors, consisting of 20 µm-thick silicon sensors paired with ⁶LiF neutron conversion layers, were tested at the FANT thermal neutron facility and at the CERN High-Energy Reference Field (CERF). Measurements included reproducibility, angular dependence, bias voltage operation, and discrimination threshold effects using a low-voltage FPGA-based readout system. The results showed stable operation under mixed radiation fields, moderate angular dependence, and strong dependence of the response on detector bias and discrimination threshold. The ultra-thin detector architecture enabled high gamma rejection capability, enabling reliable neutron detection under intense photon background conditions. These results demonstrate the suitability of 3D ultra-thin silicon detectors for compact real-time neutron monitoring in radiation protection and medical applications.

Acknowledgment

This project has received funding from the Consejo de Seguridad Nuclear (CSN) under the project Subvenciones 2022 SUB-08.

References
[1] Zorloni G. et al. “Joint EURADOS WG9-WG11 rem-counter intercomparison in a Mevion S250i proton therapy facility with Hyperscan pulsed synchrocyclotron” Phys. Med. Biol. (2022).
[2] Guardiola C. et al. “Neutron measurements with ultra-thin 3D silicon sensors in a radiotherapy treatment room using a Siemens PRIMUS linac” Phys. Med. Biol. (2013).
[3] Zamorano F. et al. “Out-of-field thermal neutron characterization with thin 3D-silicon detectors in Varian TrueBeam and Elekta Synergy LINACs” Phys. Med. Biol. (2025).
[4] Pozzi F. et al. “The CERN-EU high-energy Reference Field (CERF) facility: New FLUKA reference values of spectral fluences, present and newly proposed operational quantities” NIMA (2020).
Keywords: silicon, radiation detectors, neutron
15:00 Poster panel: 277

Poster Number:
NSS-01-277

A Full Rank Pileup Deconvolution Scheme Suitable for Calorimeter Online Trigger Primitive Generation (#1091)

J. Wu1

1 Fermi National Accelerator Laboratory, Batavia, Illinois, United States of America

Abstract

In this document, a pileup deconvolution scheme not relying on any mathematics guessing is presented.  In high energy physics experiment, as the luminosity increases, pile-up issues on detectors such as calorimeters become non-negligible.  Deconvolution approaches developed for data taken from DAQ systems are usually rank-deficient or underdetermined, having less equations than unknowns, even with the ADC values from multiple beam crossings are collected. These deconvolution approaches need mathematic pre-assumptions such as Sparse Representation.  For online computation tasks such as for trigger primitive creation, signal availability is significantly different as in offline data analysis stage, and therefore, it is possible to use different (yet simpler) algorithms.  In this situation, number of ADC values of the calorimeter outputs is the same as the number of beam crossings (or 4 times number of beam crossings, depending on the ADC sampling rate), and therefore, the number of equations can be arranged to be the same as number of unknowns.  This way, a determined deconvolution scheme with a full-rank squared convolution (and deconvolution) matrix becomes possible.  The robustness of deconvolution over long time windows is also studied in this paper.

Acknowledgment

This manuscript has been authored by Fermi Forward Discovery Group, LLC under Contract No. 89243024CSC000002 with the U.S. Department of Energy, Office of Science, Office of High Energy Physics.

Keywords: Calorimeter, Trigger System, FPGA Applications
15:00 Poster panel: 279

Poster Number:
NSS-01-279

In-orbit performance of the Tl2LiYCl6:Ce (TLYC) detector onboard the Neutron Radiation Detection Instrument-1A (NeRDI-1A) (#1372)

K. G. Oñate Melecio1, A. L. Hutcheson2, B. F. Phlips2, J. M. Davis2, T. T. Finne2, W.N. Johnson3, L. J. Mitchell2, M. V. Johnson-Rambert2, J. M. Wolf2, R. S. Woolf2, R. S. Perea4

1 Research Associate with the National Research Council, Resident at the United States Naval Research Lab, Washington D.C., United States of America
2 United States Naval Research Lab, Washington D.C., United States of America
3 Technology Service Corporation, Arlington, Virginia, United States of America
4 Former NRC Research Associate at the U.S. NRL, Washington D.C., United States of America

Abstract

The Neutron Radiation Detection Instrument-1A (NeRDI-1A) is a technology demonstration payload on the International Space Station (ISS) as part of the Department of Defense Space Test Program (STP) mission STP-H9. The primary objective of NeRDI-1A is to space-qualify two detector technologies: a dual-mode gamma-neutron  scintillator (Thallium-doped Cesium Lithium Yttrium Chloride, Tl2LiYCl6:Ce, or TLYC) and Domino microstructured semiconductor neutron detectors (MSNDs). The full NeRDI-1A suite includes a TLYC detector, three Domino MSNDs with varying moderation, and an EJ-270 plastic scintillator. This work focuses on the TLYC detector within NeRDI-1A. Here we present an analysis of the TLYC detector's response within distinct orbital regions--including the auroral regions and the South Atlantic Anomaly--during a period of minimal solar variability. We also present the evolution of the TLYC detector’s performance over its operational lifetime.

AcknowledgmentThis work was sponsored by the Office of Naval Research (ONR) as part of 6.1 funding. 
References
[1] Hutcheson, A. L., et al. 2023, "Neutron radiation detection instrument-1A (NeRDI-1A)," Proc. SPIE 12696, Hard X-Ray, Gamma-Ray, and Neutron Detector Physics XXV, 1269603, https://doi.org/10.1117/12.2682621
[2] Hawrami, R., et al. 2017, "TL2LiYCl6: Large Diameter, High Performing Dual Mode Scintillator," Cryst. Growth Des., vol. 17, no. 7, pp. 3960-3964, American Chemical Society.
[3] Clark, S. 2023, "U.S. Military Experiments Hitching Ride to Space Station on SpaceX Cargo Ship," SpaceFlightNow.com, Spaceflight Now Inc.
Keywords: neutron detection, space radiation, scintillators, sipm, gamma ray detection
15:00 Poster panel: 281

Poster Number:
NSS-01-281

Technical Design and Geometric Acceptance of the Assessing Lunar Ion-Generated Neutrons (ALIGN) Payload for Chang'E-8 (#1701)

K. Chaiwongkhot1, K. Amratisha1, K. Anuchit2, S. Burom1, S. Chindaratchakul1, H. Donghui3, P. Jamlongkul2, P. Khonsri2, J. Lakronwat1, S. Manuthasna2, T. Marsri2, W. Mitthumsiri1, P. Muangha2, T. Panyalert2, Y. Pittayang2, K. Puprasit4, D. Ruffolo1, Z. Shenyi3, J. Wannasorn2, N. Treesakul2, R. Plumanut2, W. Hantrakul2, P. Torteeka2

1 Mahidol University, Bangkok, Thailand
2 National Astronomical Research Institute of Thailand,, National Astronomical Research Institute of Thaila, Thailand
3 National Space Science Center, Chinese Academy of Sciences, Beijing, China
4 Chulabhorn Royal Academy, Bangkok, Thailand

Abstract

The Assessing Lunar Ion-Generated Neutrons (ALIGN) payload is an advanced spectrometer developed to characterize the lunar radiation environment during the Chang'E-8 mission. Designed to operate within a stringent mass allocation of 4.8 kg and optimized for low electrical consumption, the payload features a highly integrated coincidence telescope statically oriented at -30 degrees from the horizontal. This presentation details the instrumental architecture and multi-particle detection methodologies of the payload. The detector array comprises Double-Sided Silicon Strip Detectors (DSSDs), an EJ-254 boron-loaded plastic scintillator, and a primary CLYC calorimeter, all enveloped by an active BC-408 plastic scintillator veto. The system employs the ΔE-E technique—correlating initial energy loss in the DSSD transmission trackers with total energy deposited in the scintillators—to separate upward-moving albedo protons (20–140 MeV) from background electrons. Concurrently, intrinsic Pulse Shape Discrimination (PSD) within the CLYC crystal is utilized to accurately separate epithermal neutrons from gamma-ray interactions. To achieve definitive particle identification within these strict size, weight, and power constraints, a dedicated onboard FPGA executes priority-based signal processing. Geant4 simulations evaluated the instrument's overall geometric acceptance as a function of incident kinetic energy. By combining these advanced onboard logic techniques with a streamlined composite radiation shield, structural design is expected to successfully isolate lunar albedo signals from localized lander interference while fully satisfying the mission's strict engineering constraints.

AcknowledgmentThis research was supported from the NSRF via the Research and Innovation Acceleration Agency for Competitiveness and Area Development (RCAD) (Program Management Unit for Technology and Innovation for Future Industries (PMU-B): Brainpower for Future Industries) [grant number B39G690003]
References
[1] S. Zhang et al., “First measurements of the radiation dose on the lunar surface,” Science Advances, vol. 6, eaaz1334, 2020.
[2] T.B. McCord et al., “Sources and physical processes responsible for OH/H2O in the lunar soil as revealed by the Moon Mineralogy Mapper,”JGR (Planets), vol. 116, E00G05, 2011.
[3] Z. Xu et al., “Primary and albedo protons detected by the lunar lander neutron and dosimetry experiment on the lunar farside,” Front. Astron.Space Sci., vol. 9, 2022.
Keywords: Astroparticle Detectors, Chang’E-8, Geant4, Neutron Albedo, CLYC Scintillator
15:00 Poster panel: 283

Poster Number:
NSS-01-283

Cluster Size Simulation to Predict LHCb Upgrade I VELO Performance (#1945)

S. J. Williams1, E. Buchanan2, D. Friday3, J. Velthuis1

1 University of Bristol, H.H. Wills Physics Laboratory, Bristol, United Kingdom
2 University of Edinburgh, School of Physics and Astronomy, Edinburgh, United Kingdom
3 University of Manchester, Department of Physics and Astronomy, Manchester, United Kingdom

On behalf of the LHCb VELO group

Abstract

The LHCb experiment recently underwent an extensive upgrade program to allow operation at higher luminosities. The VErtex LOcator (VELO) was redesigned to a hybrid pixel layout with 130nm CMOS technology. As a result of the upgrade, the VELO will be exposed to an extreme radiation environment – over an order of magnitude greater than before. At the end of its lifetime, the innermost regions are expected to be exposed to 8x1015MeV neq cm-2 [1]. Previous analysis of bias voltage scans (presented at IEEE Yokohama, 2025) has shown the VELO is at risk of exceeding the maximum 1000V bias voltage limit to remain at operational performance. Here, we present a data-driven simulation of clusters in the VELO, to predict the performance at the end of its lifetime. Extensive validation of the simulation to testbeam data is performed, with angle and bias voltage scans showing very good agreement. Furthermore, charge sharing via diffusion in the simulation is authenticated with the charge collection vs intra-pixel hit position for size 2 clusters. Excellent agreement is seen. Comparison to Run III data is presented, showing good correspondence with the installed sensor. Extrapolations of the sensor performance at 8x1015MeV neq cm-2 are performed. Preliminary results estimate the hit efficiency to be 89.41±0.14\% and the spatial resolution to be 19.98±0.37μm (a 19.8% increase from non-irradiated). These results highlight the need to make use of beneficial annealing for the rest of the sensor lifetime, to ensure performance remains as good as possible.

References
[1] I. Bediaga. LHCb VELO Upgrade Technical Design Report. 11 2013.
Keywords: VELO, radiation, simulation
15:00 Poster panel: 285

Poster Number:
NSS-01-285

Design of Readout Electronics for a CdZnTe Detector Prototype for Polar-orbiting Solar Hard X-ray Imaging Telescope (#2200)

Z. Wang1, 2, S. Wang1, Z. Zhang1

1 Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
2 University of Science and Technology of China, School of Astronomy and Space Science, Nanjing, China

Abstract

To support the X-ray Imaging Telescope (XIT) onboard China's Solar Polar Orbiting Observatory, which aims to perform the first-ever imaging of the Sun polar regions and study high-energy processes in solar eruptions, we have developed a prototype readout electronics system for a CdZnTe hard X-ray detector. The system consists of a 2 mm thick CdZnTe detector with an effective area of 15 × 15 mm² segmented into four strip electrodes with switchable area ratios, a front-end electronics board employing the IDE4281 charge-sensitive preamplifier ASIC, and a FPGA-based data acquisition unit with integrated calibration and high-voltage supply. The IDE4281 chip provides 12 channels with programmable shaping times, self-triggering, and peak-hold outputs. In the readout prototype, the equivalent noise charge after common-mode noise subtraction ranges from 149 to 189 e⁻ across all channels. Using a ²⁴¹Am radioactive source, the detector demonstrates a full-width at half-maximum energy resolution of 4.92 keV at 59.5 keV, fulfilling the scientific requirement of better than 5 keV at that energy. These results validate the prototype design and establish the basis for the forthcoming X-ray imaging telescope instrument.

Keywords: CdZnTe detection, Readout electronics, X-ray imaging
15:00 Poster panel: 287

Poster Number:
NSS-01-287

Stability of the ATLAS Timepix3 Detector Network for Relative Luminosity Measurement in Run 3 (#2499)

C. Lesmes1, 2, B. Bergmann1, M. Beneš1, P. Broulím1, P. Burian1, 3, M. Farkaš3, T. Kulhánek3, P. Mánek1, S. Pospíšil1, O. Růžička3, P. Smolyanskiy1, O. Urban3, J. Zich3

1 Czech Technical University in Prague, Institute of Experimental and Applied Physics, Prague, Czech Republic
2 Czech Technical University in Prague, Faculty of Nuclear Sciences and Physical Engineering, Prague, Czech Republic
3 University of West Bohemia, Faculty of Electrical Engineering, Pilsen, Czech Republic

Abstract

Since its installation, the Timepix3 detector network has demonstrated utility within the ATLAS cavern by providing radiation field measurements and relative luminosity monitoring. This work evaluates the performance and internal stability of the network during the entire LHC Run 3. To ensure robust monitoring and assess systematic uncertainties, three distinct algorithms were evaluated and compared: cluster counting, thermal neutron counting, and heavy and straight track counting. 

Clean signal was achieved by identifying and masking noisy pixels and by modeling and subtracting background activation by a recursive growth and decay model. Internal consistency was verified through both short-term (intra-fill) and long-term (yearly) stability analyses across detectors situated at different distances from the interaction point. The presented results demonstrate that the distributed Timepix3 network provides a stable and robust relative luminosity measurement, complementing primary ATLAS luminometers during Run 3.

References
[1] P. Burian, et al., "Timepix3 detector network at ATLAS experiment,'' J. Instrum., vol. 13, p. C11024, Nov. 2018.
[2] B. Bergmann, et al., "Relative luminosity measurement with Timepix3 in ATLAS,'' J. Instrum., vol. 15, p. C01039, Jan. 2020.
[3] B. Bergmann, P. Burian, E. David-Bosne, et al., "Evaluation of Timepix3 as a luminosity detector at LHC during 2018 pp collisions at $\sqrt{s} = 13$ TeV,'' Eur. Phys. J. C, vol. 85, no. 904, 2025. 
[4] T. Holy, et al., "Pattern recognition of tracks induced by individual quanta of ionizing radiation in Medipix2 silicon detector,'' Nucl. Instrum. Meth. A, vol. 591, no. 1, pp. 287--290, June 2008.
[5] M. Campbell, et al., "Induced radioactivity in ATLAS cavern measured by MPX detector network,'' J. Instrum., vol. 14, p. P03010, Mar. 2019.
Keywords: Radiation instrumentation, Hybrid pixel detectors, Luminosity monitoring, ATLAS experiment, Particle identification
15:00 Poster panel: 289

Poster Number:
NSS-01-289

Radiation Studies for the LHCb Upgrade II Detector: Impact of the Upgraded Electromagnetic Calorimeter and Muon System Shielding (#2517)

S. E.R. Medaer1, G. Corti1

1 CERN, LHCb Collaboration, Geneva, Genève, Switzerland

Abstract

The LHCb Upgrade II, planned for Run5, will operate at a substantially higher luminosity than previous runs, motivating dedicated FLUKA simulations of the resulting mixed-field radiation environment. This work addresses the impact of two major changes: the upgraded Electromagnetic Calorimeter, referred to as PicoCal, and the shielding of the Muon System. The increased fraction of high-density material in the PicoCal central modules modifies shower development and neutron production, while additional shielding is required to preserve Muon System performance. All comparisons are made with respect to the same Run4 reference configuration without additional Muon System shielding. Two Muon System shielding solutions are evaluated: i) replacement of the Hadronic Calorimeter by an iron-and-concrete shield with borated-polyethylene plates upstream and downstream, and ii) retention of the present Hadronic Calorimeter followed by a ductile cast iron, borated-polyethylene and steel wall. The simulations show increased local neutron production around the PicoCal central modules, while the existing polyethylene-and-boron shield upstream of the calorimeter limits the impact on upstream sub-detectors. For the Muon System, both shielding strategies reduce the charged-particle fluence relevant for detector performance, with different spatial and particle-composition trade-offs. These results support the optimization of the LHCb Upgrade II layout and illustrate the role of detector radiation studies for shielding design in mixed-field high-energy physics environments.

AcknowledgmentThe authors would like to thank M. Karacson and M. Pycior for their contributions to the FLUKA model, L. Granado Cardosos and F. Sborzacchi for their support with the computing infrastructure, as well as P. Roloff, S. Kholodenko, A. Saputi, and A. Satta for their assistance with the detector geometry descriptions.
References
[1] LHCb-Collaboration, “Framework tdr for the lhcb upgrade ii-opportunities in flavour physics, and beyond, in the hl-lhc era,” Technical Reports CERN-LHCC-2021-012 and LHCB-TDR-023, 2021
[2] R. Aaij, A. S. W. Abdelmotteleb, C. Abellan Beteta, F. Abudin´en, C. Achard, T. Ackernley, B. Adeva, M. Adinolfi, P. Adlarson, H. Af- sharnia et al., “The lhcb upgrade i,” Journal of Instrumentation, vol. 19, no. 05, p. P05065, 2024.
[3] G. Battistoni, T. Boehlen, F. Cerutti, P. W. Chin, L. S. Esposito, A. Fasso, A. Ferrari, A. Lechner, A. Empl, A. Mairani et al., “Overview of the fluka code,” Annals of Nuclear Energy, vol. 82, pp. 10–18, 2015.
[4] C. Ahdida, D. Bozzato, D. Calzolari, F. Cerutti, N. Charitonidis, A. Cim- mino, A. Coronetti, G. D’alessandro, A. Donadon Servelle, L. Esposito et al., “New capabilities of the fluka multi-purpose code,” Frontiers in Physics, vol. 9, p. 788253, 2022.
Keywords: FLUKA, high-energy physics detectors, LHCb Upgrade II, radiation shielding, radiation simulation
15:00 Poster panel: 291

Poster Number:
NSS-01-291

Timing properties of the FARCOS detection system (#2838)

A. Castoldi1, 2, C. Guazzoni1, 2, A. Mason1, 2, M. Pozzi1, 2, R. Zambolo1, 2

1 Politecnico di Milano and INFN, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy
2 INFN, Sezione di Milano, Milano, Italy

on behalf of the fARCOS collaboration

Abstract

FARCOS is a Femtoscope Array for Correlation and Spectroscopy designed to perform studies of two- and multi-particle and Intermediate Mass Fragments (IMFs) correlations in heavy-ion collisions at Fermi energies with stable and radioactive beams. The FARCOS system is a modular assembly of up to 20 telescopes to be used in combination with 4π detectors like the CHIMERA multidetector. Each telescope features two Silicon detection layers (32 + 32 channels Double Side Silicon Strip Detectors 300μm and 1500μm thick and a third calorimetric stage, made of four truncated pyramidal CsI(Tl) crystals arranged in a 2 x 2 matrix). Particular care has been posed in the design of the frontend electronics for the different stages. For the first time we performed a detailed qualification of the timing properties of the FARCOS frontend electronics and of the different detection stages. The achievable resolution was optimized thanks to an accurate analysis of the waveform shape. The remarkable time resolution measured at zero pf capacitive input load, with the FARCOS frontend electronics, below 100 ps rms at 1.1 MeV injected charge on the 100 MeV full-scale energy range, thanks to the excellent energy resolution below 15 keV FWHM paves the way to widen the range of experiments in which the FARCOS system will be applied. The measured time resolution improves to 25 ps rms at 5 MeV injected charge. The selectable gain factor allows the extension of the full-scale energy range up to a gain factor of 0.5mV/MeV over the full-scale range of 1.1V, with a small compromise on the time resolution, translating in a dynamic range of more than 15bits. The INL keeps below 0.5% over the full dynamic range. The timing performance of the Silicon layers of the FARCOS telescopes was then qualified with a near-infrared pulsed laser system and with alpha particles. This contribution presents the results of this qualification together with some highlights of the recent applications of the FARCOS telescopes.

References
[1] FARCOS Technical Design Report, available online at https://drive.google.com/file/d/0B5CgGWz8LpOOc3pGTWdOcDBoWFE/view.
[2] L. Acosta et al., “Present status of the FARCOS detection system”, 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference Records, 2017 IEEE, Atlanta, Georgia, Oct. 21-Oct. 28, 2017, pp. 1– 4.
[3] L. Acosta et al., “The FARCOS detection system: the first application in a real experiment”, 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference Records, 2019 IEEE, Manchester, United Kingdom, Oct. 26-Nov. 2, 2019, pp. 1– 4.
[4] A. Pagano, “Studies of Nuclear Reactions and Time Scale with the 4pi Detector CHIMERA”, Nuclear Physics News International, 22, No.1, 28–33 (2012).
[5] A. Castoldi, C. Guazzoni, T. Parsani, V. L. Sicari, “Implementation and Qualification of the FARCOS Frontend Electronics”, 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Records, November 10-17, 2018, Sydney (Australia).
[6] A. Castoldi, C. Guazzoni and V. L. Sicari on behalf of the FARCOS collaboration, “Widening the application range of the FARCOS frontend electronics”, 2020 IEEE Nuclear Science Symposium and Medical Imaging Conference Records, pp. 1-4.
Keywords: fast timing, particle identification, FARCOS, correlation measurement, DSSSD
15:00 Poster panel: 293

Poster Number:
NSS-01-293

Thermal and In Situ annealing tests for SiPM radiation damage mitigation (#2917)

S. Bez Baruah1, 2, M. S. Ruzzarin1, F. Acerbi1, A. Gola1

1 Fondazione Bruno Kessler, CRS, Trento, Italy
2 University of Trento, Physics, Trento, Italy

Abstract

Silicon Photomultipliers (SiPMs) are solid-state photodetectors increasingly employed in astrophysics and space missions due to their high photon detection efficiency (PDE), compactness, insensitivity to magnetic fields, and operation at relatively low bias voltages. However, exposure to radiation, through both Ionizing Energy Loss (IEL) and Non-Ionizing Energy Loss (NIEL) effects, can degrade their key performance parameters. 
To mitigate radiation-induced damage, annealing strategies have been explored. This work presents the results of two annealing tests performed on FBK SiPMs, after x-ray irradiation and proton irradiation, highlighting their respective advantages and limitations: (1) thermal annealing, involves storing the devices in a climatic chamber without active heating, while periodically performing electrical measurements to track recovery over time. (2) In-situ current annealing progressively increases the SiPM bias current to induce self-heating via resistive effects. Electrical measurements have been done after each step, and a thermocamera have been used to monitor device temperature.

AcknowledgmentNational PhD Program in Space Science and Technology (University of Trento)
 
References
[1] R. Preghenella et al., Nucl. Instrum. Methods Phys. Res. A, Vol. 1056, pp. 168578, 2023
[2] S. Merzi, S.E. Brunner, A. Gola, A. Inglese, A. Mazzi, G. Paternoster, M. Penna, C. Piemonte and M. Ruzzarin, J. Instrum., vol. 18, P05040, May 2023
[3] F. Acerbi, A.R. Altamura, B. Di Ruzza, S. Merzi, P. Spinnato and A. Gola, Nucl. Instrum. Methods Phys Res. A., vol. 1045, 167502, 2023
[4] A.R. altamura, F. Acerbi, B. Di Ruzza, E. Verroi, S. Merzi, A. Mazzi, and A. Gola, Nucl. Instrum. Methods Phys. Res. A., vol. 1045, 167488, 2023
Keywords: SiPM, Radiation hardness, Annealing, temperature annealing, In situ current annealing
15:00 Poster panel: 295

Poster Number:
NSS-01-295

Axial Reactivity Profile Measurement of Polaris Using CR-39 Nuclear Track Detectors (#2958)

S. Alawabdeh1, P. Young1, N. Kaneshige1, W. Hennig1, D. Cech1, J. Peterson1, R. Grazioso1, M. Hua1

1 Helion Energy, Nuclear Diagnostics, Everett, Washington, United States of America

Abstract

This work presents the measurement of the axial neutron emission profile of the Polaris field-reversed configuration (FRC) fusion machine using CR-39 solid-state nuclear track detectors (SSNTDs). Passive detectors were deployed at multiple axial positions along the Polaris compression section, accumulating neutron-induced proton recoil tracks over several pulses of moderate yield, sufficiently low to resolve tracks. Chemical etching in 6M NaOH at 85°C for 2.5 hours revealed latent damage tracks, which were analyzed using a custom Python-based image processing pipeline incorporating a trained Random Forest classifier achieving 94.1%  ± 2.2% cross-validation accuracy in neutron track identification. The resulting axial track density profile is symmetric and centrally peaked, in agreement with MCNP-simulated neutron dose distributions for a thermonuclear DT fusion source confined within the FRC plasmoid. The absence of asymmetric structure - characteristic of beam-target dominated reactions - provides compelling experimental evidence of spatially confined thermonuclear fusion on Polaris. This represents the first deployment of CR-39 diagnostics for reactivity profiling on a pulsed FRC machine and establishes passive track detectors as an effective tool for fusion burn characterization.

References
[1] Frenje, JA, Li, CK, Seguin, FH, Hicks, DG, Kurebayashi, S, Petrasso, RD 2002, 'Absolute measurements of neutron yields from DD and DT implosions at the OMEGA laser facility using CR-39 track detectors', Review of Scientific Instruments, vol. 73, no. 7, pp. 2597–2605, New York: AIP Publishing.
[2] Seguin, FH, Frenje, JA, Li, CK, Hicks, DG, Kurebayashi, S, Petrasso, RD 2003, 'Spectrometry of charged particles from inertial confinement-fusion plasmas', Review of Scientific Instruments, vol. 74, no. 2, pp. 975–995, New York: AIP Publishing.
[3] Casey, DT, Frenje, JA, Seguin, FH, Li, CK, Rosenberg, MJ, Petrasso, RD 2011, 'The coincidence counting technique for orders of magnitude background reduction in data obtained with the Magnetic Recoil Spectrometer at OMEGA and the NIF', MIT Plasma Science and Fusion Center, Rep. PSFC/JA-11-11, Cambridge: MIT.
 
[4] Helion Energy 2026, 'Helion Energy' [Online], Everett: Helion Energy. Available: https://www.helionenergy.com [Accessed: 7 May 2026].
[5] Lahmann, B, Gatu Johnson, M, Frenje, JA, Glebov, VY, Séguin, FH, Petrasso, RD 2020, 'CR-39 nuclear track detector response to ions from 10 keV to 1.1 MeV/u', Review of Scientific Instruments, vol. 91, no. 5, p. 053502, New York: AIP Publishing.
[6] Lengar, I, Skvarc, J, Ilic, R 2003, 'Calibration of a CR-39 detector for neutron measurements by the track-diameter method', Radiation Measurements, vol. 36, pp. 245–248, Oxford: Elsevier.
Keywords: CR-39, neutron diagnostics, field-reversed configuration, fusion reactivity
15:00 Poster panel: 297

Poster Number:
NSS-01-297

On-detector Electronics for the ATLAS Liquid Argon Calorimeter Phase-II Upgrade at the High-Luminosity LHC (#2989)

E.J. Molina Gonzalez2, N. Nikiforou1

1 CERN, Geneve, Switzerland
2 Université Paris-Saclay, IRFU, CEA, PAris, France

On behalf of the ATLAS Collaboration

Abstract

The ATLAS Liquid Argon (LAr) calorimeter readout electronics are being upgraded for operation at the High-Luminosity Large Hadron Collider (HL-LHC), where up to 200 proton-proton interactions per bunch crossing will significantly increase detector occupancy, trigger rates, and radiation levels. While the calorimeter detectors themselves remain unchanged, the complete readout electronics chain is being replaced. The upgraded on-detector electronics readout system continuously amplifies, shapes, digitizes, and transmits calorimeter signals from approximately 182000 channels at the 40 MHz bunch-crossing rate. The new Front-End Boards (FEB2) integrate custom radiation-hard ASICs including the ALFE2 preamplifier/shaper, the COLUTA analog-to-digital converter, and lpGBT optical communication devices. Prototype boards and ASICs have been developed and extensively tested in laboratory and integration environments. This contribution presents the architecture, development status, and recent performance results of the Phase-II front-end electronics for the ATLAS LAr calorimeter.

References
[1] ATLAS Collaboration, “The ATLAS Experiment at the CERN Large Hadron Collider,” JINST, no. 3, S08003, 2008.
[2] ATLAS Collaboration, “Technical Design Report for the Phase-II Upgrade of the ATLAS LAr Calorimeter,” CERN-LHCC-2017-018, ATLAS-TDR-027, 2017.
[3] G. Aad et al., “The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters,” JINST 17, P05024, 2022.
Keywords: ATLAS, calorimeter, front-end electronics, ASIC, ADC
15:00 Poster panel: 299

Poster Number:
NSS-01-299

Resolution Limits of Planar Charge-Integrating X-ray Imaging Detectors in Diffraction Experiments (#1321)

M. Kuster1, R. Hartmann2, S. Hauf1, P. Holl2, T. Rüter3, L. Strüder2

1 European XFEL GmbH, Data Department, Schenefeld, Hamburg, Germany
2 PNSensor GmbH, München, Bavaria, Germany
3 Potsdam Institute for Climate Impact Research (PIK), Potsdam, Brandenburg, Germany

Abstract

The first generation of planar high-speed 2D charge-integrating imaging detectors is widely used in scattering experiments at free-electron laser facilities. Although diffraction is inherently defined on a spherical geometry, planar detectors are typically employed to record diffraction patterns. Current MHz frame rate detector systems offer spatial resolutions limited by pixel pitches in the range of 200 μm to 500 μm . Next-generation devel- opments aim to achieve sub-100 𝜇m resolution, introducing new challenges. At these smaller pixel sizes, second-order effects such as charge sharing, parallax distortion, and geometric projection errors become increasingly significant, whereas they are largely negligible at coarser resolutions.

In this work, we analyze the fundamental limits of distortion- free imaging imposed by planar detector geometries specifically for charge-integrating detectors, and explicitly excluding single-photon-counting approaches. We show that, for X-ray photon energies between 6 keV and 25 keV, distortion-free measurements are restricted to scattering angles of 2Θ = 0° and ≲ 13° for a 50 μm pixel pitch and 2Θ = 0◦ and ≈ 30° for 100 μm pixel pitch. Beyond these angular ranges, geometric distortions dominate the effective spatial resolution, such that a detector with 50 μm pixel pitch provides little resolution advantage over a 100 μm system. Our results identify fundamental scaling limits of planar charge-integrating detector concepts for scattering applications and establish general design constraints relevant for future high- resolution large-area detector developments at X-ray light sources.

Keywords: X-ray Detector, Pixel Detectors, Spatial Resolution, Free Electron Laser, Image Aberration Effects
15:00 Poster panel: 301

Poster Number:
NSS-01-301

Systematic X-ray irradiations of a back illuminated, HPGe, microstrip sensor. (#1420)

D. Thacker1, M. Borri1, M. Buckland1, W. Helsby1, A. Hill1, K. Sutowski1

1 UKRI - Science & Technology Facilities Council, Technology Department, Warrington, United Kingdom

Abstract

Back illuminated, HPGe, microstrip sensors are operated in the cryogenic detector system called XH. XH enables the collection of energy dispersive X-ray absorption spectra to investigate near-instantaneous structural variations in experimental samples. XH detects the transmitted radiation of a bright, single flash of X-rays that is delayed with respect to a laser pulse, which also hits the sample and creates an excited state of matter. Each strip in the HPGe sensor detects the intensity of a spectral component (∆E ∼1.5 eV) of the transmitted, dispersed polychromatic beam, which has a typical bandwidth of ∼1 keV. The HPGe sensor can be exposed to beam intensities as high as 1 × 1013 ph/mm2/s from polychromatic beams with a central energy in the range ∼5 keV to ∼25keV. The operation in this radiation harsh condition benefits from a systematic irradiation campaign to investigate ageing effects created by Total Ionising Dose (TID). The TID effects on the HPGe sensor are mitigated by design by adopting a back illumination approach in order to shield the strip contacts, and by the selection of a proprietary, commercial lithographic process. XH was irradiated at the X-ray Irradiation Facility at Daresbury Laboratory (UK). The 1024 strip sensor was repeatedly exposed to X-rays in finite time steps. Total leakage and strip currents were monitored regularly with X-rays on and off. The X-ray peak energy was limited to 20 keV, which was fully absorbed in the 1.5 mm thick HPGe sensor. This protected the strip contacts from radiation. Beam collimation within the active area of the HPGe sensor showed a steady performance, which was immune from TID. Evidence of deterioration in surface leakage current was measured when the beam was hitting the sensor edge and its supporting PCB.

AcknowledgmentThe authors would like to acknowledge the UKRI-STFC for funding the X-ray irradiations facility (ST X004837-1), and the UKRI-STFC Centre for Instrumentation for funding R&D on HPGe sensors.
References
[1] M.Borri et al, ’Prototyping experience with Ge micro-strip sensors for EDXAS experiments’, Nuclear Instruments and Methods in Physics Research A 1017 (2021) 165800
[2] M.Borri et al, ’Characterisation of Ge micro-strip sensors with a microfocused X-ray beam’, Nuclear Instruments and Methods in Physics Research A 988 (2021) 164932
[3] N.Sevelin-Radiguet et al, ’Towards a dynamic compression facility at the ´ ESRF’, Journal of Synchrotron Radiation 29 167-179
[4] Hernandez, J. A. et al, ’The high power laser facility at beamline ID24- ED at the ESRF’, High Pressure Research, 44(3), 372–399
[5] Rosa, A. D. at al, ’New Opportunities for Earth Science at the Extremely Brilliant Source of the European Synchrotron Radiation Facility’, Synchrotron Radiation News, 35(6), 8–16
[6] M.Borri et al, Commissioning of an X-ray irradiation facility to test HPGe sensors and to irradiate CMOS electronics, 2024 IEEE NSS MIC RTSD, https://doi.org/10.1109/NSS/MIC/RTSD57108.2024.10655927
Keywords: High-purity germanium sensors, cryogenic detector systems, X-rays.
15:00 Poster panel: 303

Poster Number:
NSS-01-303

Energy-resolved Laue Diffraction: a New Tool for Crystal Structure determination (#1715)

D. P. Siddons1, A. K. Rumaiz1, M.D. Drakopoulos1, N. Vo1, Z. Zhong1, A. J. Kuczewski1, J. Kuczewski2, J. Li1, W. Chen2

1 Brookhaven National Laboratory, NSLS-II, Upton, New York, United States of America
2 Brookhaven National Laboratory, Instrumentation, Upton, New York, United States of America

Abstract

White beam Laue diffraction is well-known as a means to orient single-crystal samples, but its use as a structure-determining tool is less exploited. One of the difficulties with the method is its incomplete measurement of the diffraction vector. Only its direction can be determined, but not its length, since conventional instrumentation does not provide the diffracted beam energy. In this paper we propose to use a high-resolution energy resolving detector to provide that information, together with NSLS-II’s HEX beamline, which has a spectral range up to 200keV. We have developed a series of microstrip germanium detectors, and present here some measurements using one of them together with a horizontal aperture to emulate a 192 x 1 pixel detector with 250 micrometer pixels. By scanning this device in one dimension we could simulate a 2-dimensional detector with good energy resolution,. We have further designed and built a custom detector for this purpose, which has 192x2 pixels, each 250 x 250 micrometers, and so does not need the aperture, and which requires half the number of measurements. Data collected with these detectors will be presented.

AcknowledgmentThis research used resources of the National Synchrotron Light Source II, a U.S. Department of Energy (DOE) Office of Science User Facility operated for the DOE Office of Science by Brookhaven National Laboratory under Contract No. DE-SC0012704.
Keywords: X-ray, Laue diffraction, germanium detector
15:00 Poster panel: 305

Poster Number:
NSS-01-305

Pile-Up Resilient X-Ray Spectroscopy via Direct Sampling and Waveform Fitting in SDDs (#1993)

A. Abba1, V. Arosio1, P. Barcella2, F. Caponio1, M. Carminati2, E. Carlotti1, S. Carsi1, A. Cusimano1, C. E. Fiorini2, M. Lazzari1, B. Pedretti2, E. Proserpio1, C. Tintori3, Y. Venturini3

1 Nuclear Instruments SRL, Lambrugo, Italy
2 Politecnico di Milano, DEIB, Milano, Italy
3 CAEN SPA, Viareggio, Italy

Abstract

A fully digital readout architecture is described for high-throughput X-ray spectroscopy with silicon drift detectors (SDDs). The core challenge is the large-amplitude voltage ramp produced by transistor reset preamplifiers, which conventionally prevents direct digitization at spectroscopic resolution. In this work, sampling the preamplifier output with a 20-bit SAR ADC achieves a dynamic range exceeding 10⁶, eliminating any analog conditioning stage upstream of the digitizer.

Throughput is sustained by combining four converters in a time-interleaved scheme, yielding an aggregate sampling rate of 160 Msps. A Zynq SoC provides the processing backbone, performing inter-channel timing alignment, gain equalization, and concurrent execution of the signal processing pipelines.

Two energy estimation algorithms run in parallel on the digitised data: a ramp-corrected trapezoidal filter and a model-based least-squares fitter that uses linear regression over the full inter-event sample record, remaining accurate even when pulse separation shrinks to sub-microsecond intervals. Experimental characterisation with ARDESIA multi-pixel SDD arrays and KETEK single-pixel detectors yields an energy resolution of 120.7 eV FWHM at low rate, 150 eV at 1 Mcps, and 180 eV at 2 Mcps, with live time exceeding 90% throughout.

Keywords: DAQ, MCA, X-RAY, Model based fitting, High rate spectroscopy
15:00 Poster panel: 307

Poster Number:
NSS-01-307

High-resolution Germanium Detector system for Fluorescence-Mode X-ray Absorption Spectroscopy (#2626)

A. K. Rumaiz1, F. Capocasa2, A. J. Kuczewski1, G. Pinaroli2, T. Krings3, B. Ravel4, D. P. Siddons1

1 Brookhaven National Laboratory, NSLS II, Upton, New York, United States of America
2 Brookhaven National Laboratory, Instrumentation Department, Upton, New York, United States of America
3 Forschungszentrum, Jülich, Germany
4 National Institute of Standards and Technology, Gaithersburg, Maryland, United States of America

Abstract

Fluorescence-mode X-ray Absorption Spectroscopy (XAS) at high photon energies require detectors with both high stopping power and excellent energy resolution to measure weak element-specific fluorescence signals. Conventional silicon-based detectors suffer from poor absorption efficiency above ~20 keV, while most high-𝒁 semiconductor materials such as cadmium telluride (CdTe), cadmium zinc telluride (CZT), and gallium arsenide (GaAs) have largely been developed for imaging applications with comparatively limited spectroscopic performance. In contrast, Germanium combines excellent stopping power with superior intrinsic energy resolution owing to its low Fano factor and favorable charge transport properties, making it particularly attractive for spectroscopy in the 15-100 keV range. Here we report the development, fabrication, and characterization of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system designed for fluorescence-mode XAS. Gepta-EX incorporates a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers inside a thermally isolated compact cryostat operating near 90K. The detector achieves energy resolutions of 218 eV at  5.9 keV using an 55Fe source and 373 eV at 59.5  keV using an 241Am source, with uniform response across all channels. By avoiding the escape-peak interference commonly associated with silicon detectors while maintaining stable high-resolution performance at elevated X-ray energies, Gepta-EX provides a powerful platform for high-energy X-ray spectroscopy and fluorescence-mode XAS applications.

Keywords: EXAFS, Germanium, Spectroscopy
15:00 Poster panel: 309

Poster Number:
NSS-01-309

Visualization of beta-emitting nuclides in water using a CCD camera and CaF₂ scintillator (#1462)

Y. Morishita1, M. Kanno2

1 Japan Atomic Energy Agency, Collaborative Laboratories for Advanced Decommissioning Science (CLADS), Futaba County, Japan
2 PESCO Co., Ltd., Tokyo, Japan

Abstract

At nuclear facilities such as decommissioning sites and reprocessing plants, continuous monitoring of radioactive liquid waste is essential to prevent the spread of contamination. While gamma-emitting radionuclides can be detected relatively easily using gamma-ray detectors, radionuclides emitting only alpha or beta radiation are difficult to measure remotely because these particles are strongly absorbed in water. Conventional liquid scintillation counting requires sample collection and pretreatment, making real-time monitoring difficult. In this study, a real-time visualization method for beta-emitting nuclides in water was developed using a calcium fluoride (CaF₂) scintillator and an Electron Multiplying CCD (EM-CCD) camera. The scintillator was designed with a water-permeable structure to allow contaminated water to flow through it, enabling direct detection of beta radiation in water. Radiation source measurements were performed in a dark room using a 90Sr–90Y beta source. Scintillation light generated in the CaF₂ scintillator was captured by the EM-CCD camera. The results demonstrated that the position of the beta source could be successfully visualized with acquisition times as short as 1 s, and the detected intensity increased with measurement time. Measurements conducted while moving the source confirmed that changes in source position could also be visualized, indicating the capability to monitor moving contamination in water. In addition, water infiltration tests confirmed that water could successfully pass through the scintillator structure. These results demonstrate that the proposed system is promising for real-time monitoring and visualization of beta-emitting radionuclides in radioactive liquid waste and aquatic environments.

References
[1] Montaña, M., et al. "The presence of radionuclides in wastewater treatment plants in Spain and their effect on human health." Journal of cleaner production 60 (2013): 77-82.
[2] Yeung, K. H., H. Y. Mok, and H. K. Lam. "An on-line water contamination monitoring system." Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 353.1-3 (1994): 550-552.
[3] Choi, Woo Nyun, et al. "Continuous beta monitoring technology for uncontrolled radiological release in underwater using integrated beta and gamma detection system." Nuclear Engineering and Technology 57.3 (2025): 103248.
[4] [4] Tarancón, A., et al. "Development of an equipment for real-time continuous monitoring of alpha and beta radioactivity in river water." Applied Radiation and Isotopes 187 (2022): 110322.
Keywords: Radiation monitoring, CaF₂ scintillator, Beta-emitting nuclides, CCD camera
15:00 Poster panel: 311

Poster Number:
NSS-01-311

Diagnosing Mechanisms for Charged Particle Attenuation Enhancement in Nanostructured Materials (#1508)

N. P. Speck1, G. J. Grey2, D. A. Vecchio1, K. A. Cotterill1, A. I. Taub2, M. D. Hammig1

1 University of Michigan, Nuclear Engineering and Radiological Sciences Department, Ann Arbor, Michigan, United States of America
2 University of Michigan, Materials Science and Engineering Department, Ann Arbor, Michigan, United States of America

Abstract

This paper presents a methodology for measuring the trajectories of high-energy electrons through materials utilizing a transmission electron microscope (TEM). This novel technique is implemented to diagnose and quantify the mechanism for enhanced radiation attenuation via nanostructures. Rather than an imaging technique, the TEM is applied to radiation shielding measurements as an adaptable electron source with functionality for various beam energies, amperage, alignments, and exposure times alongside an array of precise electron detectors. By utilizing energy filtering and direct electron detection capabilities, scattering profiles are measured with minimal background contributions. This TEM method is leveraged to describe particle transport in nanostructures. Palladium nanoparticles at various monodisperse sizes are synthesized via heat injection and deposited into an epoxy matrix. The palladium epoxy nanocomposites are sectioned with an ultramicrotome to thicknesses of 70 to 1000 nm containing nanoparticle sizes of 5 to 50 nm at 20% of the total weight fraction. Scattering profile measurements at various beam energies are conducted with a variety of sample thicknesses, nanoparticle sizes, and composite fractions. Scattering profile measurements also include bulk, homogeneous palladium samples in contrast to nanomaterials composed of identical atomic percentages. Simulation of the experimental scattering profiles demonstrate an understanding for the phenomena behind nanostructured attenuation enhancement, bolstering advanced nuclear technology via a foundational description for particle transport in nanostructures.

AcknowledgmentThe authors acknowledge the financial support of the University of Michigan College of Engineering and technical support from the Michigan Center for Materials Characterization and Michigan Medicine Microscopy Core. Thank you to Tao Ma for guidance on operating the TFS Spectra 300 TEM and Megan Bennett for support on ultramicrotome sample preparation. 
References
[1] S. A. Thibeault, J. H. Kang, G. Sauti, C. Park, C. C. Fay, and G. C. King, “Nanomaterials for radiation shielding,” MRS Bulletin, vol. 40, no. 10, pp. 836--841, Oct. 2015, doi: 10.1557/mrs.2015.225.
[2] A. Rosh-Gorsky et al., “3D Printing of Composite Radiation Shielding for Broad Spectrum Protection of Electronic Systems,” Advanced Materials, vol. 36, no. 33, p. e2403822, 2024, doi: 10.1002/adma.202403822.
[3] M. Steffens et al., “Characterization of Novel Lightweight Radiation Shielding Materials for Space Applications,” IEEE Transactions on Nuclear Science, vol. 64, no. 8, pp. 2325--2332, Aug. 2017, doi: 10.1109/TNS.2017.2703312.
[4] A. Hamisu et al., “The use of nanomaterial polymeric materials as ionizing radiation shields,” Radiation Physics and Chemistry, vol. 216, p. 111448, Mar. 2024, doi: 10.1016/j.radphyschem.2023.111448.
[5] P. Hosemann, E. Stergar, A. T. Nelson et al., “Nanostructured Engineering Alloys for Nuclear Application,” MRS Online Proceedings Library, vol. 1298, pp. 217--226, 2011.
[6] V.-D. Le et al., “X-ray and gamma-ray Sensing from Aqueous-Based Lead Sulfide Telluride Nanocomposites,” Small, vol. 21, 2025.
[7] A. Curtis et al., “Micro-scale fusion in dense relativistic nanowire array plasmas,” Nature Communications, vol. 9, p. 1077, 2018, doi: 10.1038/s41467-018-03466-7.
Keywords: TEM, Radiation Shielding, Attenuation, Nanoparticles, Nanomaterials
15:00 Poster panel: 313

Poster Number:
NSS-01-313

Monolithic integration of cooling microchannels in all-silicon ladders for vertex detectors (#1940)

J. Fernández-Tejero1, A. Dias1, M. Duch1, R. Mas1, C. Orero2, M. Vos2, M. Ullán1

1 Centro Nacional de Microelectrónica (IMB-CNM, CSIC), Cerdanyola del Vallés, Spain
2 Instituto de Física Corpuscular (IFIC, CSIC), Paterna, Spain

Abstract

New generation of vertex detectors must have excellent thermo-mechanical stability, and all-silicon ladders are considered as promising solutions for future detectors. However, power consumption asymmetries between the active area and periphery can induce large temperature gradients, and in some cases a combination of air and liquid cooling will be required to achieve homogeneous thermal profiles. Microchannel cooling offers a competitive alternative to traditional cooling systems. The short thermal path between the heat load and sink gives an increased thermal evacuation performance, combined with the reduced material needed for the integrated microchannels and the reduced Coefficient of Thermal Expansion mismatch between the cooling and sensor materials to obtain an optimized cooling for radiation detectors. The development of the technology needed for the integration of the sensor with the microchannels in a single piece is an ambitious challenge, as the conditions for the microchannel formation must be compatible with the sensor, requiring the optimization of the fabrication to ensure the compatibility with CMOS processes. As a demonstrator, all-silicon ladder prototypes with integrated cooling microchannels are presented. Power consumptions for the active area and periphery of the ladders are emulated using integrated aluminum heaters. The bulk in the active area is thinned from 600 to 50 microns, and the design of the microchannels cooling circuit, integrated in the periphery of the ladder, is optimized using finite-element simulation packages. Variations of prototype ladders with different sizes, microchannel dimensions, and integrated using different wafer bonding techniques are fabricated and evaluated in detail in this work.

AcknowledgmentThis work has received funding from the postdoctoral fellowships programme Beatriu de Pinós (Marie Skłodowska-Curie grant No 801370), and Spanish R&D grant PID2024-156645NB-C22 funded by MICIU/AEI/ 10.13039/501100011033 and by ERDF/EU.
References
[1] de Aguiar Francisco OA, Buytaert J, Collins P, et al., 'Evaporative CO2 microchannel cooling for the LHCb VELO pixel upgrade', Journal of Instrumentation, 10 (2015) C05014
[2] Andricek L, Boronat M, Fuster F, et al., 'Integrated cooling channels in position-sensitive silicon detectors', Journal of Instrumentation, 11 (2016) P06018
[3] Vos M, 'Micro-channel cooling in high energy physics', Proceedings of science, 287 (2016) 037
[4] Flaschel N, Ariza D, Díez S, et al., 'Thermal and hydrodynamic studies for micro-channel cooling for large area silicon sensors in high energy physics experiments', Nuclear Instruments and Methods A, 863 (2017) 26-34
[5] Ullán M, Correa J, Dauderys V, et al., 'Development of silicon interposers with embedded microchannels and metal re-distribution layer for the integration of hybrid detector systems', Nuclear Instruments and Methods A, 1065 (2024) 169490
Keywords: Microchannel cooling, Embedded microchannels, Monolithic integration
15:00 Poster panel: 315

Poster Number:
NSS-01-315

A spin-selective detector for quantum sensing with neutrons (#1977)

T. Neulinger1, S. Degenkolb2, R. Gernhäuser3, R. Georgii1, C. Grüner1, H. Haese4, S. Kempf5, 6, T. Sandmann2, J. Tremmel2, M. Wegner6, 5

1 Technische Universität München, Forschungs-Neutronenquelle Heinz Maier-Leibnitz, Garching, Bavaria, Germany
2 Universität Heidelberg, Physikalisches Institut, Heidelberg, Baden-Württemberg, Germany
3 Technische Universität München, E12 Dense and Strange Hadronic Matter, Garching, Germany
4 S-DH GmbH, Heidelberg, Baden-Württemberg, Germany
5 Institute of Micro- and Nanoelectronics Systems, Karlsruhe Institute of Technology, Karlsruhe, Baden-Württemberg, Germany
6 Institute for Data Processing and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Baden-Württemberg, Germany

Abstract

We present performance calculations for a proof-of-concept, spin-selective neutron detector in which the magnetic field of a microfabricated planar superconducting coil controls the quantum mechanical absorption resonance in a multilayer structure. For first tests with cold neutrons, depolarization calculations favor a parallel over a meander geometry, the latter of which should nevertheless offer enhanced detector sensitivity in the ultracold neutron regime. Simulations predict that spin contrasts can be efficiently demonstrated using polarized cold neutron reflectometry at existing facilities.

References
[1] S. Degenkolb, P. Fierlinger, and O. Zimmer "Approaches to high-density storage experiments with in-situ production and detection of ultracold neutrons," J. Neutron Res., vol. 24, pp. 123-143, Sep. 2022, 10.3233/JNR-220044.
[2] S. Kempf, A. Fleischmann, L. Gastaldo, and C. Enss, "Physics and Applications of Metallic Magnetic Calorimeters," J. Low Temp. Phys., vol. 193, no. 3, pp. 365--379, Nov. 2018, 10.1007/s10909-018-1891-6.
[3] A. Vorobiev et al., "Recent upgrade of the polarized neutron reflectometer Super ADAM," Neutron News, vol. 26, no. 3, pp. 25--26, Aug. 2015, 10.1080/10448632.2015.1057054
[4] J. F. Ziegler, M. D. Ziegler, and J. P. Biersack, "SRIM – The stopping and range of ions in matter (2010)," Nucl. Instrum. Methods Phys. Res. B, vol. 268, no. 11--12, pp. 1818--1823, 2010, 10.1016/j.nimb.2010.02.091.
Keywords: ultracold neutrons, quantum sensor, superconductor, polarized neutrons, neutron reflectivity
15:00 Poster panel: 317

Poster Number:
NSS-01-317

Higher-Order Gain-Drift Correction in Magnetic Microcalorimeters for Decay Energy Spectrometry (#2186)

R. Wood1, 2, I. Jovanovic1, G.-B. Kim2

1 University of California, Berkeley, Nuclear Engineering, Berkeley, California, United States of America
2 Lawrence Livermore National Laboratory, Livermore, California, United States of America

Abstract

Metallic magnetic calorimeters can provide excellent energy resolution for decay-energy spectrometry of alpha- and beta-emitting radionuclides, but temperature-dependent gain drift can broaden peaks during long acquisitions. This work compares two post-acquisition correction models for data acquired with a gold-erbium paramagnetic sensor in the MAGNETO-ν neutrino experiment. The pre-trigger baseline is used as an event-by-event proxy for detector temperature. The lower-order model includes linear baseline dependence, whereas the higher-order model adds baseline-energy cross terms and second-order baseline dependence to capture nonlinear drift. Model parameters are estimated with a likelihood-based fit to known plutonium and americium reference peaks, and each event is calibrated by solving the fitted response model for deposited energy. Performance is evaluated from isotope-resolved peak widths in the corrected alpha-decay region of the spectrum. Across the reference groups considered here, the higher-order model produces consistently narrower fitted peaks, with the clearest improvements in the higher-statistical-weight isotope groups. These results indicate that higher-order baseline terms can improve spectral resolution when baseline-correlated drift is present.

Acknowledgment

This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. This material is based upon work supported by the Consortium for Nuclear Forensics under Department of Energy, National Nuclear Security Administration award number DE-NA0004142. This work was supported by the Laboratory Directed Research and Development program of Lawrence Livermore National Laboratory under Project No. 23-LW-043.

References
[1] S. Kempf, A. Fleischmann, L. Gastaldo, and C. Enss, “Physics and applications of metallic magnetic calorimeters,” J. Low Temp. Phys., vol. 193, pp. 365-379, 2018, doi: 10.1007/s10909-018-1891-6.
[2] R. Wood, G.-B. Kim, I. Jovanovic, C. Lee, N. Hines, and T. Parsons-Davis, “Radioisotope dating of nuclear materials using cryogenic decay energy spectrometry,” J. Radioanal. Nucl. Chem., vol. 335, pp. 2371-2379, 2026, doi: 10.1007/s10967-026-10742-1.
[3] J. W. Fowler et al., “The practice of pulse processing,” J. Low Temp. Phys., vol. 184, no. 1-2, pp. 374-381, 2016, doi: 10.1007/s10909-015-1380-0.
[4] M. O. Herdrich et al., “Application of a metallic-magnetic calorimeter for high-resolution x-ray spectroscopy of Fe at an EBIT,” J. Phys. B At. Mol. Opt. Phys., vol. 57, Art. no. 085001, 2024, doi: 10.1088/1361-6455/ad34a2.
[5] M. L. Zahir, M. Rodrigues, M. Loidl, and A. Kaur, “Energy non-linearity study of a high-resolution metallic magnetic calorimeter,” Radiat. Phys. Chem., vol. 220, Art. no. 111730, 2024, doi: 10.1016/j.radphyschem.2024.111730.
[6] C. Lee et al., “Search for a heavy neutral lepton with the MAGNETO-ν experiment using 241Pu β− decays,” Phys. Rev. C, vol. 113, Art. no. 024620, 2026, doi: 10.1103/4xt7-mdyv.
Keywords: decay-energy spectrometry, gain-drift correction, metallic magnetic calorimeters.
15:00 Poster panel: 319

Poster Number:
NSS-01-319

Pixelated Array for Low-Energy Electron Beam Mapping (#2374)

M. Turqueti1, O. Aggarwal1

1 Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, California, United States of America

Abstract

We present a low-energy electron beam position detector based on a segmented capacitive sensing architecture designed for precision monitoring of electron beams in the 500 eV to 2000 eV energy range. The detector employs a 3 mm × 3 mm capacitive sensor structure optimized for non-invasive beam position measurements with micrometer scale spatial resolution. Low-energy electron beams present unique diagnostic challenges due to their sensitivity to electromagnetic perturbations, beam spreading, and reduced signal levels. Conventional beam diagnostics often suffer from limited sensitivity or introduce disturbances that alter the beam trajectory.

The proposed detector addresses these limitations through a pixelated capacitive pickup array combined with low-noise front-end electronics and differential signal processing techniques. Variations in induced charge distribution along the sensing electrodes are used to reconstruct the transverse beam position with high precision while maintaining minimal interaction with the electron beam. The array enables accurate position tracking over extended beam paths and improves sensitivity to small beam displacements.

Analytical modeling and preliminary experimental characterization demonstrate that the sensor can resolve beam motion at the micrometer level across the targeted energy range. The detector response was evaluated as a function of beam energy, beam current, and electrode geometry, showing stable operation and high linearity under low-energy conditions. Noise mitigation strategies, including shielding and optimized capacitance matching, were implemented to preserve signal integrity and reduce environmental interference.

This detector architecture is well suited for applications requiring compact, high-resolution diagnostics of low-energy electron beams, including micro cathode ray magnetic probes, electron optics experiments, and vacuum electronic devices.

References
[1] Takahiro Nishi, Tamaki Watanabe, Taihei Adachi, Ryo Koyama, Naruhiko Sakamoto, Kazunari Yamada, and Osamu Kamigaito," Nondestructive beam envelope measurements using beam position monitors for low-beta heavy ion beams in a superconducting linear accelerator",Phys. Rev. Accel. Beams 28, 092803 – 2025,DOI: https://doi.org/10.1103/8ct7-x1xf
[2] Jun He, Yanfeng Sui, Yong Li, Huizhou Ma, Yaoyao Du, Ying Zhao, Wan Zhang, Shujun Wei, Taoguang Xu, Junhui Yue,"Beam position monitor design for the High Energy Photon Source ",Measurement Science and Technology, Volume 33, Number 11,2022,DOI 10.1088/1361-6501/ac8277
[3] Yong Zhang (张雍), Jun-Xia Wu (武军霞), Guang-Yu Zhu (朱光宇), Huan Jia (贾欢), Zong-Heng Xue (薛纵横), Hai Zheng (郑海), Hong-Ming Xie (谢宏明), Xin-Cai Kang (康新才), Yuan He (何源), Lin Li (李林), " Chinese Physics C
Paper Capacitive beam position monitors for the low-β beam of the Chinese ADS proton linac*",Chinese Physics C, Volume 40, Number 2,2016, DOI 10.1088/1674-1137/40/2/027003
[4] S. Bheesette and M. Turqueti, "Simulation Studies For The Electron Gun Based Magnetic Probe," 2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Piscataway, NJ, USA, 2021, pp. 1-2, doi: 10.1109/NSS/MIC44867.2021.9875587.
[5] P. Li, B. G. Sun, Q. Luo, X. H. Wang, H. L. Xu and P. Lu, "New methods of measuring emittance using beam position monitors," 2007 IEEE Nuclear Science Symposium Conference Record, Honolulu, HI, USA, 2007, pp. 1675-1678, doi: 10.1109/NSSMIC.2007.4437322.
Keywords: Pixel, Beam Position Monitor, Low Energy Electrons, Sensor, Capacitive
15:00 Poster panel: 321

Poster Number:
NSS-01-321

Self-Powered Wireless Communication via Ambient Gamma-Ray Harvesting at Fukushima Daiichi (#2629)

T. Fujiwara1, Y. Shoji1, H. Kimura1, S. Mae2, H. Yoshimochi2, K. Kawasaki2, H. Kawamura2, K. Miyako2

1 National Institute of Advanced Industrial Science and Technology (AIST), Tskuba, Japan
2 Chiyoda Technol Corporation, Tokyo, Japan

Abstract

Reliable long-term monitoring in nuclear decommissioning facilities is hampered by the absence of permanent power infrastructure and by the radiation fields that degrade conventional electronics. We present a scintillator-photovoltaic converter that captures ambient gamma radiation and transforms it into electrical energy sufficient for periodic wireless data transmission. The converter pairs a 750 cm³ CsI(Tl) crystal with a compact GaInP photovoltaic array mounted on a single end face, following a "large absorber, minimal semiconductor" strategy.) On-site evaluation inside a contaminated-material storage building at the Fukushima Daiichi Nuclear Power Plant (~35 mSv/h) produced 273 nW per module. Two parallel modules, combined with ultra-low-power energy management and a sub-GHz radio, achieved seven autonomous transmission bursts totaling 32 packets over a 30 m link during a three-hour observation window—without any external power supply or dedicated radioactive source.

References
[1] IAEA, Monitoring and Surveillance of Radioactive Waste Disposal Facilities, Safety Reports Series No. 84, 2014.
[2] Fujiwara, Takeshi, et al. "Demonstration of self-powered wireless transmission using a gamma-ray battery in a nuclear decommissioning environment." Available at SSRN 6191942.
Keywords: gamma-ray energy harvesting, scintillator-photovoltaic conversion, self-powered wireless sensor, nuclear decommissioning, CsI(Tl)
15:00 Poster panel: 323

Poster Number:
NSS-01-323

Optimizing Tritium Uptake and Detection Sensitivity in a Metal-Hydride Gas Detector (#2734)

P. Kandlakunta1, L. R. Cao1, R. Young1, A. Hoffman1

1 The Ohio State University, Department of Mechanical and Aerospace Engineering, Columbus, Ohio, United States of America

Abstract

The Metal-Hydride and Gas (MEGA) detector is a recently proposed approach for high-selectivity tritium (T2) monitoring that combines hydrogen (H2) storage metals with gas proportional counting. Previous work demonstrated the feasibility of T2 absorption in palladium (Pd), formation of metal-tritide, and subsequent T2 release into a proportional counter for measurement. In this work, we investigate pathways toward improving the overall detection efficiency of the MEGA detector through optimization of T2 absorption, retention, desorption, and counting characteristics. A simplified efficiency framework is introduced to identify the dominant efficiency-limiting processes. The pressure–composition behavior of the Pd–H system is examined to evaluate approaches for enhancing isotope uptake at low T2 partial pressures through reduced operating temperature and increased local pressure. Preliminary Monte Carlo simulations of tritium β-particle transport in Pd indicate strong self-absorption effects, with the simulated maximum penetration depth of 18.6-keV β-particles in Pd limited to a few hundred nanometers. These results support the need for optimized Pd geometry and efficient thermal desorption approaches to maximize gas-phase T2 release and proportional counting efficiency. The present work establishes a quantitative framework for future optimization of MEGA detector sensitivity for environmental and nuclear safeguards applications.

Acknowledgment  This research is supported by the U. S. Department of Energy / National Nuclear Security Administration under Award Number DE-NA0004196.
Keywords: tritium, metal-hydride, gas detector, environmental monitoring, nuclear non-proliferation
15:00 Poster panel: 325

Poster Number:
NSS-01-325

Basic Development of a Wide-Field EUV Polarimeter for High-Energy Transient Sources (#3164)

S. Kuwabara1, S. Gunji2, K. Chiba1, A. Takahashi1, M. Kitaura2, E. Nakamura3

1 Yamagata University, Graduate School of Science and Engineering, Yamagata, Japan
2 Yamagata University, Faculty of Science, Yamagata, Japan
3 Institute for Molecular Science, UVSOR Synchrotron Facility / Beamline Technical Staff, Aichi, Japan

Abstract

Polarization observations in extreme ultraviolet (EUV) band have not yet been achieved because it remains technically difficult to develop wide-field EUV detectors with sufficient sensitivity. However, EUV polarization measurements are expected to provide important insights into the emission mechanisms of gamma-ray bursts (GRBs) and ultraviolet flashes associated with supernova explosions. In this study, we propose a novel EUV polarimeter based on Lobster-Eye Optics (LEO), which combines a wide field of view with polarization sensitivity. Optical simulations show that EUV reflectivity on metal surfaces strongly depends on polarization. For example, at 40 eV and an incident angle of 75° on a gold-coated mirror, the reflectivity is about 40% for p-polarization and 60% for s-polarization, respectively. This difference produces an asymmetric cross-shaped image on the focal plane detector depending on the polarization direction. To verify this principle, we developed a test chamber and conducted a synchrotron radiation experiment using a gold-coated mirror and a microchannel plate (MCP) detector. By rotating the mirror around the beam axis, we measured the modulation of the MCP count rate and evaluated the detector modulation factor. The experimental results are presented and discussed in this paper.

Acknowledgment

The authors would like to thank the UVSOR staff for their technical support during the synchrotron radiation experiments. Portions of the manuscript preparation were assisted by a cloud-based AI language model.

References
[1] Fan, YZ & Wei, DM 2004, ‘UV/optical emission accompanying gamma-ray bursts’, Monthly Notices of the
Royal Astronomical Society, vol. 351, no. 1, pp. 292–296.
[2] Di Marco, A., Fabiani, S., La Monaca, F., Muleri, F., Rankin, J., Soffitta, P., Xie, F., et al. 2022, ‘Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation’, Astronomical Journal, 164(3), 103, Bristol: IOP Publishing.
Keywords: Astrophysics, extreme ultraviolet (EUV), polarimeter
15:00 Poster panel: 327

Poster Number:
NSS-01-327

Cryogenic and Underground Performance of the Diffuse BGO Scintillator Array in the KAPAE Phase II Detector (#3216)

D. Jeong1, H.J. Kim2, 1, J. Cho1, H. Park3

1 Kyungpook National University, Center for High Energy Physics, Daegu, Republic of Korea
2 Kyungpook National University, Department of Physics, Daegu, Republic of Korea
3 2Central Research Institute, Korea Hydro & Nuclear Power Co., Ltd., DaeJeon, Republic of Korea

Abstract

The KNU Advanced Positronium Annihilation Experiment (KAPAE) Phase II searches for invisible positronium decays using a compact 4π BGO scintillation calorimeter. Stable operation, efficient photon collection, and low-background performance are essential for this rare-event measurement. We report the cryogenic and underground performance of a chemically diffused BGO scintillator array developed for KAPAE Phase II.

The BGO crystal surfaces were chemically diffused to enhance photon collection and coupled to SiPM-based readout for low-temperature operation. At approximately −37 °C, reduced SiPM thermal noise and improved light collection yielded an energy resolution of 9% at 662 keV. The scintillation decay time was approximately 960 ns. This performance improves upon earlier BGO-based positronium calorimeters, including the ETH Zurich experiment, which reported an energy resolution of approximately 15% [1].

The detector was installed and operated at Yemilab underground. A continuous 120-day run demonstrated stable detector response, trigger operation, and long-term data-taking capability under cryogenic conditions. Calibration data were used to tune and validate a Geant4 detector simulation, which was applied to evaluate energy containment, gamma-ray leakage, and the expected sensitivity for invisible para-positronium decay searches. Based on measured performance and validated simulations, KAPAE Phase II achieves the expected sensitivity of 10−8 for invisible para-positronium branching-ratio measurements.

This study demonstrates that chemically diffused BGO scintillator arrays can provide stable, high-resolution calorimetric performance under cryogenic underground conditions.

AcknowledgmentThese investigations were supported by the National Research Foundation of Korea (NRF), funded by the Ministry of Science and Technology, Korea (MEST) (RS-2024-00348317).
References
[1] A. Badertscher et al., “Improved limit on invisible decays of positronium,” Phys. Rev. D 75, 032004 (2007).
Keywords: BGO, SiPM, Positronium, KAPAE, Underground rare-event search
15:00 Poster panel: 329

Poster Number:
NSS-13-329

Organic Scintillator Light Yield Models for Sub-MeV Neutrons in EJ301D and d-stilbene (#1369)

C. A. Irvine1, 2, T. C. Borgwardt1, R. A. Weldon Jr.1, J. Mattingly2

1 Los Alamos National Laboratory, NEN-2, Los Alamos, New Mexico, United States of America
2 North Carolina State University, Nuclear Engineering, Raleigh, North Carolina, United States of America

Abstract

Six commonly used models for neutron induced light yield in organic scintillators were fit and analyzed using measurements of a 2.54 cm diameter by 2.54 cm long right circular cylinder of EJ301D and a (5.08 cm)3 custom made cube of deuterated trans-stilbene-d12 (d-stilbene). Measured neutron energies spanned 300 keV to 2200 keV for the EJ301D scintillator and 200 keV to 2500 keV in d-stilbene. The model fits and experimental analysis methods were verified by examining the agreement between the predicted light output spectrum and the measured light output spectrum for several simulated quasi-monoenergetic neutron sources. Birks model inaccurately predicted highly quenched light yield for sub-MeV neutrons in both scintillators. The addition of a second order quenching term to the Birks model by Chou significantly improved the models accuracy, however its behavior is non-physical if extrapolated beyond the measured neutron energies. The model derived by Voltz accurately fit the measurement of both scintillators for all measured neutron energies. Further investigation into the ability to extrapolate based on these semi-empiric models would be valuable given the non-physical behavior of well-fitting models.

AcknowledgmentThis work was supported by the US Department of Energy through the Los Alamos National Laboratory. Los Alamos National Laboratory is operated by Triad National Security, LLC, for the National Nuclear Security Administration of U.S. Department of Energy (Contract No. 89233218CNA000001).
References
[1] Thibault A Laplace et al. “Modeling ionization quenching in organic scintillators”. In: Materials Advances 3.14 (2022), pp. 5871–5881
[2] Mark A. Norsworthy et al. “Evaluation of neutron light output response functions in EJ-309 organic scintillators”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 842 (2017), pp. 20–27. ISSN: 0168-9002. DOI: https://doi.org/10.1016/j.nima.2016.10.035.
[3] John Betteley Birks. The theory and practice of scintillation counting: International series of monographs in electronics and instrumentation. Vol. 27. Elsevier, 2013.
[4] CN Chou. “The nature of the saturation effect of fluorescent scintillators”. In: Physical Review 87.5 (1952), p. 904.
[5] J Hong et al. “The scintillation efficiency of carbon and hydrogen recoils in an organic liquid scintillator for dark matter searches”. In: Astroparticle Physics 16.3 (2002), pp. 333–338. ISSN: 0927-6505. DOI: https://doi.org/10.1016/S09276505(01)00114-1
[6] S Yoshida et al. “Light output response of KamLAND liquid scintillator for protons and 12C nuclei”. In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 622.3 (2010), pp. 574–582.
[7] R. Voltz et al. “Influence of the Nature of Ionizing Particles on the Specific Luminescence of Organic Scintillators”. In: The Journal of Chemical Physics 45.9 (Nov. 1966), pp. 3306–3311. ISSN: 0021-9606. DOI: 10.1063/1.1728106. eprint: https://pubs.aip.org/aip/jcp/article-pdf/45/9/3306/18846420/3306 1 online.pd
[9] G. Dietze and H. Klein. “Gamma-calibration of NE213 scintillation counters”. In: Nucl. Instr. and Meth. 193.3 (1982), pp. 549–556. ISSN: 0167-5087. DOI: 10.1016/0029-554X(82)90249-X.
[11] C. A. Irvine et al. “Low energy neutron light output characterization of EJ301D and deuterated stilbene with a comparison of light output characterization methods”. In: Submitted for review (2026).
Keywords: Organic Scintillators, Deuterated Scintillators, EJ301D, d-stilbene, Light Output Model


Our Exhibitors: