Emerging Directions in Theranostic Imaging: From PET and SPECT to Novel Modalities

Session chair: Abbaszadeh, Shiva, (University Of California, Santa Cruz / ECE, Santa Cruz, USA); Caravaca, Javier, Dr. (LBNL, Nuclear Science, Berkeley, USA)
 
Shortcut: WS-04
Date: Saturday, 14 November, 2026, 15:00 - 19:00
Location: MANUEL DE FALLA
Session type: Workshops

sponsored by

 

Summary

Radiotheranostics, combining targeted molecular therapies with diagnostic imaging, holds great promise to transform healthcare decision-making by supporting individualized treatment planning, monitoring, and optimization. However, advanced imaging technologies for radiotheranostics are still emerging, and significant scientific, technical, and clinical challenges must be addressed to unlock their full potential in clinical environments. This workshop provides a dedicated forum for interested researchers to review past achievements, report recent progress and novel techniques, and discuss remaining challenges and future directions toward clinical translations. Key focus areas include optimizing the application of alpha and beta emitters enabled by novel imaging instrumentation, unconventional imaging techniques, advanced image reconstruction, dosimetry methods, simulation toolkits, and AI/ML methods for radiotheranostics.

We will invite interested presenters to submit separate abstracts to this workshop by August 31. We also invite industry partners and collaborators to attend and support this workshop.

We have created a special issue related to the content of this workshop in IEEE Transactions on Radiation and Plasma Medical Sciences (TRPMS). This Special Issue (https://ieee-trpms.org/current-special-issues/) will be a collection of manuscripts associated with presentations and submitted abstracts in this workshop, after peer-review processes for the journal acceptance.

 

Contact

Youngho Seo, University of California, San Francisco (youngho.seo@ucsf.edu)
Shiva Abbaszadeh, University of California, Santa Cruz (sabbasza@ucsc.edu)
Javier Caravaca, Lawrence Berkeley National Laboratory (jcaravacarodriguez@lbl.gov)
Joshua Cates, Siemens Healthineers (joshuawcates@gmail.com)
Pedro Correia, University of Aveiro (pmcorreia@ua.pt)
Andrea Gonzalez-Montoro, i3M CSIC-UPV, Valencia (andrea.gm@i3m.upv.es)

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

15:00 WS-04-01

Radiotheranostics Beyond Boundaries: Hardware, AI, and the Future of Quantitative Imaging (#3328)

P. Correia1, A. Gonzalez-Montoro2, S. Abbaszadeh3, J. Caravaca4, 5, J. Cates6, Y. Seo5, 7, 8

1 University of Aveiro, Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Aveiro, Portugal
2 CSIC-UPV, Institute for Instrumentation in Molecular Imaging (I3M), Valencia, Spain
3 University of California, Santa Cruz, Department of Electrical and Computer Engineering, Santa Cruz, California, United States of America
4 Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, California, United States of America
5 University of California, San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, California, United States of America
6 Siemens Healthineers, Molecular Imaging, Knoxville, Tennessee, United States of America
7 University of California, Berkeley, Department of Nuclear Engineering, Berkeley, California, United States of America
8 Lawrence Berkeley National Laboratory, Molecular Biophysics & Integrated Bioimaging Division, Berkeley, California, United States of America

Abstract

Cancer treatment has shifted from empirical, toxicity-based dosing toward precision oncology guided by the specific genetic and molecular profiles of individual tumors. Within this framework, physicians, medical physicists, engineers, and scientists share the responsibility of developing tools to deliver high-precision treatments, predict therapeutic responses, and track disease progression. Radiotheranostics contributes to this approach by leveraging advanced radiochemistry to design highly selective molecules that deliver diagnostic or therapeutic radionuclides to target cells. Although routine at major medical centers for metastatic disease, broader adoption requires advances in imaging performance and targeted radiopharmaceuticals. Conventional PET and SPECT systems remain constrained by physical limits in spatial resolution, sensitivity, and quantitative accuracy, all of which are critical for clinical translation. Addressing these gaps requires higher sensitivity and spatial resolution, refined reconstruction algorithms for improved image clarity, precise image-based dose calculations, and system standardization. These needs drive hardware development toward total-body and organ-specific PET and SPECT systems, as well as new gamma, x-ray, and hybrid imaging methods. For high linear-energy transfer approaches like targeted alpha therapy, ex vivo micro-scale imaging is increasingly important to measure dose heterogeneity at the suborgan/cellular level. Concurrently, artificial intelligence is improving image reconstruction and dose prediction. Finally, key translational challenges must be addressed: ensuring trial reproducibility, integrating new methodologies into clinical workflows, and demonstrating cost-effectiveness alongside tangible patient benefit. This workshop brings together experts across these areas to collaborate and advance next-generation radiotheranostic technologies.

Keywords: radiotheranostics, PET, SPECT, AI, quantitative imaging
15:15 WS-04-02

A Long Axial-FOV PET System with Embedded Spectroscopic Gamma-Cameras for In Vivo Imaging of Radiopharmaceutical Therapy (#3322)

Y. Jin1, J. Du2, S. R. Cherry2, 3, L.-J. Meng1, 4, 5

1 University of Illinois at Urbana and Champaign, Department of Nuclear, Plasma and Radiological Engineering, Urbana, Illinois, United States of America
2 University of California at Davis, Department of Biomedical Engineering, Davis, California, United States of America
3 King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
4 University of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois, United States of America
5 University of Illinois at Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States of America

Abstract

The development of radiotheranostics would greatly benefit from quantitative imaging techniques that can simultaneously map the distributions of diagnostic and therapeutic radionuclides across spatial, temporal, and functional domains. To address this need, we will present the design of a proposed preclinical PET/SPECT platform consisting of a long-axial-FOV PET scanner with embedded CZT pinhole camera modules. The system is designed to simultaneously image both PET tracers and typical SPECT isotopes, as well as therapeutic radionuclides, such as Lu-177, Ac-225, Ra-223, and At-211.

The PET subsystem is based on dual-ended-readout BGO detectors with a diameter of 16 cm and an axial length of 16 cm. The BGO detectors in the central portion are purposefully positioned to leave small gaps to accommodate micro-gamma-camera elements (MGCE’s) based on high-resolution CZT detectors with pinhole collimation for radionuclides. The MGCE’s are designed to cover a wide dynamic range of 20 keV to 700 keV, so the combined PET and SPECT system will be capable of imaging virtually all commonly used SPECT isotopes and therapeutic radionuclides. In addition, data acquisition for the PET and SPECT subsystems is synchronized via a unified clock-and-trigger architecture. It enables coincidence detection of both PET and single-photon signals. Correlations among detected photons in the spectral and temporal domains are used to reject down-scattering noise in SPECT acquisition and to identify cascade emission of gamma rays from Lu-177 and Ac-225.

In this presentation, we will discuss a comprehensive design study of an integrated PET/SPECT imaging system and its potential to characterize the complex pharmacokinetics of radionuclide therapies.

Keywords: PET, SPECT, radiotheranostics, CZT
15:30 WS-04-03

A High-Resolution Mobile Gamma-Camera for optimizing dosimetry in Molecular Radiotherapy : first clinical feasibility study for treatment of thyroid diseases with Radioactive Iodine (#3281)

T. Bossis1, M.-A. Verdier1, 2, L. Vija4, F. Courbon5, D. Vallot6, C. Nascimento4, O. Caselles6, T. Beaumont3, F. Bouvet1, L. Pinot1, L. Menard1, 2

1 Université Paris-Saclay, CNRS/INP3, IJCLab, Orsay, France
2 Université Paris Cité, IJCLab, Orsay, France
3 ASNR, LEDI, Fontenay-aux-roses, France
4 Nuclear Medicine Department, Oncopole Claudius Regaud, Toulouse, France
5 Nuclear Medicine Department, Oncopole Claudius Regaud and Toulouse University, Toulouse, France
6 Medical Physics Department, Oncopole Claudius Regaud, Toulouse, France

Abstract

Molecular radiotherapy requires personalized dosimetry for efficient treatment and reduced toxicity, but current clinical imaging systems and miniaturized gamma-cameras lack the required capabilities. We developed a mobile gamma-camera with a 10×10 cm2 field of view tailored for quantitative assessment of 131I biokinetics during therapy of thyroid diseases. The system combines interchangeable 3D-printed tungsten collimators, a monolithic scintillator read out by a SiPM array, and commercial electronics. It achieves an intrinsic spatial resolution of 1.15 mm FWHM and negligible deadtime up to 150 kcps. Images are reconstructed in real time using an experimental data-trained convolutional neural network. The collimators and shielding were adjusted with Monte-Carlo simulations in order to reduce septal penetration and scattering. Preclinical studies demonstrated high quantitative accuracy, with activity bias below 5%, even for small sources. These performances stem from the camera’s compactness and mobile design, which enables shorter detector-to-target distances, optimized viewing angles, as well as from its high overall spatial resolution (4–6 mm at 365 keV). Its mobility also avoids transporting radioactive patients, reducing radiation exposure for staff and other patients. A first clinical feasibility study involving 20 patients with benign thyroid diseases was completed in March 2025, to assess patient acceptance and image quality during planning and post-treatment follow-up, compared with a standard gamma camera (Syngula). Results indicate unprecedented image quality around 400 keV with direct quantitative information, particularly for post-therapeutic imaging, enabling  improved assessment of heterogeneous 131I distribution, including for Graves' disease. This highlights the potential of the camera for personalizing administered activity and, more importantly, estimating the dose actually absorbed during treatment, directly linked to therapeutic success.

Keywords: Dosimetry-guided radionuclide therapy, High-resolution molecular imaging, Mobile gamma-camera, Quantitative imaging, Thyroid diseases
15:37 WS-04-04

The Personalized Remote Radiation Tracking Portable Organ Dosimetry Device (#3335)

R. S. Miyaoka1, W. C. Hunter1, P. S. Guntha3, G. Maliakal2, E. Ingalls3, T. M. Whalen3, M. T. Kim3, G. Jones3, S. A. Hauck3, A. M. Alessio2

1 University of Washington, Radiology / Nuclear Medicine, Seattle, Washington, United States of America
2 Michigan State University, CMSE, BME, and Radiology, Lansing, Michigan, United States of America
3 University of Washington, Department of Electrical Engineering, Seattle, Washington, United States of America

Abstract

We are developing a Personalized Remote Radiation Tracking Portable Organ Dosimetry Device (PRRT PODD) for at-home monitoring of patients receiving radiopharmaceutical therapy. The goal of this work is to provide a user and facility friendly device to enable organ at risk (OAR) dosimetry for patients undergoing Lu-177 DOTATATE treatment. The PRRT PODD consists of a portable frame with wings that encircle the patient's torso from the base of their kidneys to the top of their liver. In addition, there is a registration pad that enables precise positioning of the patient in the PODD for daily measurements. The patient lies down in a PODD template during their therapy qualifying PET/CT scan. This registers the PODD to their anatomy. Using software tools, a sensitivity matrix between the patient’s OAR and tumors is determined for a two-dimensional (2D) array of potential detector locations along the surface of the PODD. Using this matrix, 16-32 detector locations are selected based upon the patient’s specific anatomy to enable activity estimation for the patient’s OAR. After a quantitative SPECT/CT scan acquired 24-hours after treatment, a PODD measurement will be made in clinic to normalize with the SPECT/CT scan. The PODD will then be sent home with the patient for fourteen 5-minute daily measurements. The PODD utilizes a carbon fiber base plate, a vacuumable Styrofoam registration pad, 3D printed wings, compact pinhole SiPM-based radiation detectors, battery-operated acquisition electronics, and a cell phone app that supports wireless transmission from the PODD’s detector to a remote computer workstation. Our updated simulation software supports placement of a virtual 2D array of detectors on the polygonal surface defined by the PODD. An overview of the PODD development along with results from simulations based on human imaging examples will be provided at the workshop.

AcknowledgmentThis work was supported by NIH R01CA287205. We thank Robert Harrison for extensions to SimSET.
Keywords: Theranostics, portable, personalized, remote radiation monitoring, wireless
15:44 WS-04-05

Incorporating X-Ray and gamma-Ray Coincidence Detection for Improved Detection Efficiency and Image Quality in 177Lu Imaging (#3306)

K. Wang1, T. Dai2, Z. Hang3, H. Liu4, J. Wu5, Y. Liu4, Z. He3, Q. Wei1

1 University of Science and Technology Beijing, Beijing Engineering Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, Beijing, China
2 China–Japan Friendship Hospital, Department of Radiation Oncology, Beijing, China
3 Tsinghua University, Beijing Tsinghua Changgung Hospital, Beijing, China
4 Tsinghua University, Department of Engineering Physics, Beijing, China
5 Beijing Normal University, Center for Advanced Quantum Studies, Beijing, China

Abstract

In conventional 177Lu imaging that relies solely on single photons or cascade gamma photons, the detection efficiency is fundamentally limited by the low photon emission probabilities. The decay of 177Lu produces not only γ photons but also characteristic X-rays through the internal conversion process. In this work, we propose a multi-type time coincidence imaging strategy that exploits characteristic X-rays together with γ photons to improve the detection efficiency and image quality of 177Lu imaging. The feasibility of X–X, X–γ, and γ–γ coincidence detection is analyzed based on the decay characteristics of 177Lu, and a full-ring coincidence imaging system is subsequently employed for performance evaluation. Experimental results show that the integration of multiple coincidence-event types increases the system detection efficiency by 107.60\% and improves the contrast-to-noise ratio (CNR) by 8.39\% compared with conventional γ–γ coincidence imaging, while preserving nearly unchanged spatial resolution.

AcknowledgmentThis work was supported in part by the National Key Research and Development Program of China under Grant 2022YFC2402001; in part by the National Natural Science Foundation of China under Grant 12375337; and in part by the Beijing Natural Science Foundation under Grant L232126.
Keywords: 177Lu imaging, Internal conversion, Characteristic X-ray, Time coincidence
15:51 WS-04-06

Physics-Corrected List-Mode MLEM Reconstruction for Quantitative 177Lu Cascade Gamma Coincidence Imaging (#3289)

H. Ye1, 2, 3, H. Liu4, Q. Wei5, H. Jia6, H. Hu1, 2, 7, Z. Hang7, T. Dai8, Z. He7, Y. Liu4, J. Wu1, 2, 3

1 Beijing Normal University, Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing, China
2 Beijing Normal University, Key Laboratory of Multiscale Spin Physics, Ministry of Education, Beijing, China
3 Beijing Normal University, Center for Health and Aging, Beijing, China
4 Tsinghua University, Department of Engineering Physics, Beijing, China
5 University of Science and Technology Beijing, School of Automation and Electrical Engineering, Beijing, China
6 Tsinghua University, School of Biomedical Engineering, Beijing, China
7 Tsinghua University Changgung Hospital, Changgung Hospital, Beijing, China
8 China-Japan Friendship Hospital, Department of Radiation Oncology, Beijing, China

Abstract

Cascade gamma coincidence imaging is an alternative to conventional single photon imaging for therapeutic radionuclides such as 177Lu by exploiting time-correlated cascade photon pairs. However,  high spatial resolution and reliable quantitative accuracy remain challenging because of photon attenuation, scatter, partial volume effects. We developed a cascade-coincidence list-mode maximum-likelihood expectation-maximization (CCLM-MLEM) framework for a full-ring 177Lu cascade gamma coincidence imaging system. Attenuation correction (AC) and scatter correction (SC) were incorporated into reconstruction, followed by absolute quantification and post-reconstruction partial volume correction (PVC). The system response matrix was modeled according to the cascade-photon detection geometry. The framework was evaluated using seven-point-source and hot-rod phantoms for spatial-resolution assessment, the modified image-quality phantom for quantitative evaluation, and the Mouse Whole-Body (MOBY) digital phantom for small-animal imaging. Direct backprojection (DBP) was used for comparison. CCLM-MLEM reduced the mean point-source FWHM from 2.20±0.10 mm with DBP to 1.51±0.27 mm and resolved 1.0-mm rods, compared with 1.5-mm rods using DBP. In the modified image-quality phantom, AC and SC improved activity and contrast recovery at comparable noise levels. In the MOBY phantom, the relative bias for a 4-mm tumor decreased from -57.19% without correction to 1.83% after AC, SC, and PVC. These results support high-resolution quantitative 177Lu cascade gamma coincidence imaging and its potential for preclinical radiopharmaceutical imaging and dosimetry.

AcknowledgmentSupported by National Key Research and Development (R&D) Program of China (2022YFC2402003, 2022YFC2402002), National Natural Science Foundation of China (No. 12305379, No.12205166), Beijing Natural Science Foundation (Z220010), CIRP Open Fund of Radiation Protection Laboratories (TNMPP-2024-No.1).
Keywords: cascade gamma coincidence imaging, list-mode MLEM, lutetium-177, physics-based correction, quantitative imaging
15:58 WS-04-07

Learning Support Priors from 177Lu with Projection-Domain Constraint for Quantitative 225Ac SPECT Reconstruction (#3267)

Z. Dong1, X. Meng2, X. Jin2, W. Liu1, X. Ding2, Y. Sun2, L. Yuan4, N. Li2, Z. Yang2, M. Lu3, J. Li3, Q. Ren1, J. Yu2, Z. Xie1, 5

1 Peking University, National Biomedical Imaging Center, College of Future Technology, Beijing, China
2 Peking University Cancer Hospital & Institute, Department of Nuclear Medicine, Beijing, China
3 Peking University Cancer Hospital & Institute, Department of Gastrointestinal Oncology, Beijing, China
4 Beijing Sinotau International Pharmaceutical Technology Co., Ltd., Beijing, China
5 Peking University Health Science Center, Peking University, Institute of Medical Technology, Beijing, China

Abstract

Background: 225Ac targeted alpha therapy requires quantitative post-therapy SPECT for verification and dosimetry. Multiple emissions, scatter, and inter-window crosstalk complicate reconstruction.
Methods: We developed a 177Lu-informed deep support-driven kernel (DSDK). A support generator was pretrained on 63 clinical [177Lu]Lu-DOTATATE SPECT scans using simulated projections at multiple count levels and a projection-consistency objective. For 225Ac reconstruction, the learned support was used only to construct an image-domain kernel prior; activity remains governed by measured multi-energy projections and a Poisson model. Scatter and crosstalk are explicit projection-space physical models using MC-optimized DEW and self-consistent crosstalk correction for 218-keV, 440-keV, and joint-window reconstruction. Evaluation included MC calibration, single-sphere NEMA IQ scatter-window validation, dual-sphere IQ CNR-COV assessment at 15/30/60 s, and 10-patient [225Ac]Ac-DOTATATE SPECT/CT evaluation. Baselines included OSEM, DDIP-TTA, and PET-guided methods; PET was not a DSDK input.
Results: MC selected a narrow 5% lower scatter window beside ±10% photopeak windows, with projection MSEs of 0.16/0.10 at 218/440 keV. Single-sphere joint-window CNR/SBR rose from 3.032/8.390 without scatter correction to 3.104/9.081. Dual-sphere DSDK with crosstalk improved the CNR-COV trade-off, especially at 15/30 s; at a representative joint window, CNR/COV was 22.2/0.87 versus 17.1/1.19 for DDIP-TTA. Clinically, joint-window DSDK achieved TBR 2.43 ± 1.27 and the highest lesion CNR among non-PET-prior methods. DSDK also achieved the highest joint-window lesion SSIM, 0.88 ± 0.05, without a PET-derived prior.
Conclusion: DSDK integrates support-level transfer, projection-consistent statistical reconstruction, and crosstalk physical modeling for quantitative multi-window 225Ac SPECT and may support patient-specific dosimetry.

Acknowledgment

Supported by NSFC Grant 62394311, 62394310, 625B2004, and 12505390.

Keywords: Actinium-225 SPECT, Targeted Alpha Therapy, Quantitative Imaging, Physics-Guided Reconstruction, Radiotheranostics
16:05 WS-04-08

Rapid Extended-Distance 177Lu Imaging with a Portable Telephoto-Lens Magic-Cube Gamma Camera for Intra-Procedural Theranostic Assessment (#3290)

Y. Zhang1, Z. Lyu1, 2, J. Xu2, Y. Hu3, Y. Zhang1, 2, W. Chi2, Z. Zhao2, W. Cheng4, 5, K. Chen4, 5, H. Cai4, 5, T. Ma1

1 Tsinghua university, Department of Engineering Physics, Beijing, China
2 Greater Bay Area National Center of Technology Innovation, Guangzhou, China
3 Yale University, Department of Radiology and Biomedical Imaging, New Haven, Connecticut, United States of America
4 Sichuan University, Laboratory of Clinical Nuclear Medicine and Department of Nuclear Medicine, West China Hospital, Chengdu, China
5 Sichuan University, Sichuan Provincial Engineering Research Center of Radiopharmaceutical Clinical Translation, Chengdu, China

Abstract

Immediate visualization of therapeutic radionuclide distributions could provide useful spatial feedback during or shortly after interventional radionuclide therapy, but this use case requires a portable camera to acquire images quickly without close contact with the target region. We evaluated a Telephoto-Lens Magic-Cube portable gamma camera for rapid 177Lu imaging using hybrid front-end long-hole geometric encoding and detector-side self-collimation encoding. A measured 177Lu system matrix covered an 80 × 80 mm² field of view and source-to-camera distances of 8–22 cm. Across 54 point-source positions from 10–20 cm, mean absolute localization errors were 0.26, 0.32, and 2.58 mm along the x, y, and z axes, respectively. Representative dual-source reconstructions showed visually distinguishable hotspots separated by 5–7 mm at distances of 10–18 cm. At approximately 16 cm, all principal hotspots remained visible in 1 s reconstructions of three phantoms and an in vivo rat liver, with NCC values of 0.942–0.992 and transverse hotspot displacements of 0.27–1.12 mm relative to 300 s references. An excised rat liver containing 72.2 μCi of residual 177Lu also showed a localized activity region. These results demonstrate the feasibility of rapid 177Lu distribution imaging at extended working distances for procedure-room theranostic assessment.

Keywords: portable gamma camera, Lu-177 imaging, hybrid encoding, extended working distance, self-collimation
16:12

Open Discussion I

16:40

Coffee Break

17:10 WS-04-09

Implementation of Radiation Detection Technologies, Quality Assurance, and Harmonized Control Standards for Theragnostic Programs in Emerging Healthcare Systems. (#3321)

I. M. Rossi1, 2, M. C. Plazas1, P. N. Martinez1

1 Universidad Nacional de Colombia, Physics Department, Bogotá D.C., Colombia
2 IEEE, Colombian Section, New York, New York, United States of America

Abstract

Theragnostic imaging is an emerging approach in precision oncology that combines molecular imaging with targeted radionuclide therapy. Its safe and effective implementation requires not only advanced radiopharmaceuticals, but also reliable radiation detection systems, standardized quality control (QC), and comprehensive quality assurance (QA) throughout the imaging and treatment workflow. This work focuses on the role of radiation detection technologies in theragnostics, including detector performance, calibration and verification of QC equipment, and radiopharmaceutical quality assessment.

Particular attention is given to radionuclide and radiochemical purity, activity calibrator verification, measurement traceability, and harmonized QA protocols. The work also addresses challenges in conventional gamma spectrometry, particularly spectral overlap in composite and low-activity samples, highlighting maximum-likelihood estimation (MLE) approaches for improved activity quantification of theragnostic radionuclides using NaI(Tl) detectors. In addition, emerging detector materials such as graphene quantum dots are considered for their potential to enhance radiation detection technologies.

The study discusses the challenges of implementing theragnostic programs in emerging healthcare systems, emphasizing the need for international standards, specialized training, appropriate infrastructure, and adaptable regulatory frameworks. These elements are essential to achieving accurate personalized dosimetry, reliable treatment planning, and safe, standardized theragnostic practices.

AcknowledgmentWe gratefully acknowledge the support of the Universidad Nacional de Colombia and Vicerrectoría de Investigación through research project HERMES 64204, funded under the 2024 Innovation and Artistic Creation Projects Call.
Keywords: Theragnostics, Gamma Spectrometry, Quality Assurance, Quality Control.
17:25 WS-04-10

New Horizons in Ultra-High Resolution 3D CZT Detectors and its impact on preclinical SPECT/PET (#3309)

A. Cherlin1, F. Beekman2, 3, 4

1 Kromek Ltd., Sedgefield, United Kingdom
2 TU Delft, dept. Radiation Science & Technology, Delft, Netherlands
3 Free Bee Int’l, Delft, Netherlands
4 The Molecular Imaging Foundation, Delft, Netherlands

Abstract

Clinical and preclinical demand for higher-precision molecular imaging across an extended energy range is pushing gamma-ray detectors beyond the limits of conventional SPECT. CZT detectors offer excellent energy resolution and good sensitivity for high-energy isotopes, but position resolution and spectral distortions, including charge sharing and depth dependence, remain limited by pixel size, detector thickness, and cost of scaling readout electronics.

A novel approach is presented, using machine learning models trained on high-fidelity simulations to extract sub-pixel and depth-of-interaction (DOI) information from anode signals. Implemented in a prototype CZT gamma camera, the method achieves 10×10 sub-pixelisation of 2 mm pixels, DOI resolution of ~500-800 µm, and gamma-camera-level energy resolution with spatial precision approaching mid-range x-ray detectors, pointing toward a new class of high-resolution SPECT instrumentation.

A key challenge is the increased demand on readout speed and bandwidth. Accurate positioning requires acquisition of positive and negative signals across pixel clusters, increasing data volume and processing requirements while limiting real-time operation and scalability.

To address this, we explore neural network inference integrated directly into the detector front-end, enabling photon-by-photon signal processing. A dedicated ASIC will digitise and buffer electrode signals, which are then characterised by a neural-state machine that outputs high-level interaction data. A pulse-level simulation framework is being developed to train and validate front-end neural network models.

We will present the first implementation of this framework on pixelated and drift-strip CZT detectors, with simulation results demonstrating improved multi-interaction event discrimination and reconstruction. This work provides a route to compact, high-resolution gamma detectors for next-generation theranostic imaging, from radionuclide therapy dosimetry to hybrid modalities.  An example will be shown on what the impact of using high-end 3D CZT instead of traditional NaI Anger detectors could be on the architecture and performance of a new multi-isotope PET/PET PET/SPECT imaging module in Free Bee International’s U-VET preclinical open PET/SPECT/CT/Optical/Ultrasound platform (World Molecular Imaging Society Innovation of the Year 2026 )
Keywords: CZT, SPECT, Drift-Strip detectrors, Subpixelization
17:39 WS-04-11

A multimodal C-arm enabling concurrent X-ray and nuclear imaging for cost-effective theragnostic interventions (#3316)

D. R. Schaart1, M. M. Dietze2, C. E. Kerckhaert2, L. Schröder1, M. Snoeyink1, N. Wijnen2, H. W. De Jong2

1 Delft University of Technology, Medical Physics & Technology, Delft, Netherlands
2 University Medical Center Utrecht, Radiology and Nuclear Medicine, Utrecht, Netherlands

Abstract

Theragnostic interventions commonly require both fluoroscopic and nuclear image guidance. In liver tumor radioembolization, for example, 90Y microspheres are injected into the liver bloodstream under fluoroscopy. First, 99mTc microspheres are administered, and a SPECT scan is made. Therapeutic 90Y microsphere delivery is typically performed two weeks later, based on the results of the pre-treatment procedure. If a SPECT scan of the 99mTc microsphere distribution can be made inside the intervention room, the pre-treatment and treatment procedures can be merged into a single session, enabling in-situ adaptation of the catheter position and near-real time, personalized dosimetric treatment planning. Moreover, the burden for the patient as well as the overall cost of treatment are reduced. To this end, a first prototype of an interventional X-ray and scintigraphy imaging (IXSI) system was built at UMC Utrecht. It consists of a C-arm equipped with an X-ray tube and a detector stack consisting of an adapted X-ray flat panel detector positioned in front of a gamma camera fitted with a cone-beam collimator. Here, we report on two recent developments. First, a clinical trial is ongoing in which the first patients with liver cancer are receiving single-session radioembolization using the IXSI prototype. Second, X-ray imaging is currently limited to 70 kVp and the X-ray tube is translated off-focus from the focal point of the cone-beam collimator by 5 cm, to avoid blinding of the gamma camera by X-rays penetrating through the flat-panel detector. To enable concurrent, intrinsically co-registered X-ray and nuclear imaging using X-ray spectra up to 120 kVp, a novel detector stack is under development, comprising a gamma camera based on a low-afterglow, pixelated NaI(Tl) scintillator read out by SiPMs. An update of these developments will be presented at the workshop.

AcknowledgmentThis work was funded in part by EU Horizon grant 101257367.
Keywords: Theragnostic intervention, Radioembolization, Multimodal imaging, X-ray imaging, Nuclear imaging
17:46 WS-04-12

Theranostic SPECT with High Energy Resolution CZT Detectors (#3334)

J. R. Kuchta1, P. G. Hotvedt1, 2, Z. Ouyang1, D. Paylan1

1 MH3D Inc., Ann Arbor, Michigan, United States of America
2 University of Michigan, Nuclear Engineering and Radiological Sciences, Ann Arbor, Michigan, United States of America

Abstract

An increasing number of isotopes have seen use in theranostic applications but have generally been limited by poor image quality or low quantification accuracy. These limitations are caused by factors like low emission intensities, clustered photopeaks, or lower system sensitivity. These factors drive the use of easier to image surrogate isotopes for biodistribution studies. Theranostic SPECT with CZT semiconductors reduces the need for traditional cut-and-count measurements and can produce quality reconstructions for isotopes that are otherwise difficult to image. The Alpha-SPECTTM Mini preclinical device utilizes CZT semiconductors as the detecting medium, providing the highest energy resolution with a full-body field-of-view for mice. This SPECT imager has a 2.5% single-pixel energy resolution at 140 keV, and it has been used in the imaging of popular isotopes such as 225Ac, 213Bi, 212Pb, 211At, 177Lu, 111In, and 99mTc.
The detectors’ superior energy resolution allows for discrimination of the clustered photopeaks in the X-ray energy regions of 225Ac and 212Pb. Projection windows with sufficient separation from the tungsten characteristic X-ray at 60 keV allow for removal of excess scatter in reconstructed images, one of the major image degradation factors in low-emission isotope imaging. The system’s high sensitivity enables the dynamic imaging of fast decaying isotopes over the whole body of a mouse, such as 213Bi with its 45-minute half-life. The dynamic imaging function has been utilized for binning as small as 2 seconds for 99mTc, 1 minute for 211At, 15 minutes for 213Bi, and 30 minutes for 225Ac. This functionality unveils important information on theranostic isotope distribution shortly post-injection.

Keywords: Theranostics, CZT Detectors, Alpha-SPECT, X-ray Imaging
17:53 WS-04-13

Fast Timing for High-Energy Gammas with GAGG and BGO for Improved Theranostic (#3313)

F. Pagano1, A. Gonzalez Montoro1, F. Loignon-Houle1, A. Olmos Risen1, J. Cates2, J. Caravaca2, A. J. Gonzalez1

1 Institute for Instrumentation in Molecular Imaging (I3M), CSIC-Universitat Politècnica de València, Valencia, Spain
2 Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkley, California, United States of America

Abstract

Time-of-flight (TOF) improves effective sensitivity and image signal-to-noise ratio in positron emission tomography (PET). Other medical applications that benefit from high time resolution include ion range verification in hadron therapy via prompt gamma imaging and dose verification in targeted alpha therapy via cascade gamma imaging. All these applications would benefit from intrinsically radiation-free scintillators, motivating the search for alternatives to LYSO. GAGG is a strong candidate due its high light yield, which enables good energy resolution, and to its fast decay time, which makes GAGG's time resolution very competitive. At high gamma energies — between 1–7 MeV, the range relevant to prompt gammas in hadron therapy and to characteristic gammas emitted in cascade by alpha-emitting isotopes — BGO also becomes particularly attractive, as its prompt Cherenkov photon yield increases significantly in this range.

Here, we present a proof-of-concept measurement of the time resolution of BGO and GAGG at ~1 MeV. Pairs of 3×3×15 mm³ BGO and GAGG crystals, coupled to FBK-NUV-MT SiPMs, were read out using state-of-the-art high-frequency electronics. Each crystal pair detected in coincidence the gamma cascade from a 60Co source (1173 keV and 1333 keV gamma rays emitted with a sub-picosecond half-life). In our preliminary studies, we achieved a coincidence time resolution (CTR) FWHM of 120 ps for GAGG and 188 ps for BGO, while for 511 keV the CTRs are 179 ps and 245 ps, respectively. Additionally, simulations are used to investigate Cherenkov photon detection yield and time resolution as a function of gamma-ray energy. These results highlight the potential of GAGG and BGO both for TOF-PET and other emerging applications involving high-gamma energies.

Acknowledgment

This work was partially funded by the European Union (ERC, PHOENIX, 101164363). The authors express their gratitude to César Domingo-Pardo and his team for hosting the measurements in their laboratory.

Keywords: time of flight, cascade gamma imaging, cherenkov
18:00 WS-04-14

Event-Based Alpha- and Beta- Particle Imaging with iQID: From Quantitative Digital Autoradiography to Isotope Identification (#3326)

B. W. Miller1, 2, J. W. Moore2

1 The University of Arizona, Radiation Oncology and Radiology & Imaging Sciences, Tucson, Arizona, United States of America
2 QScint Imaging Solutions, Tucson, Arizona, United States of America

Abstract

The growth of radiopharmaceutical therapy (RPT) has created an increasing need to characterize RPT distributions at microscopic spatial scales, where heterogeneity can strongly influence absorbed dose and biological response. This is particularly important for alpha-particle therapies, where information of the activity distributions is needed at spatial scales comparable to alpha-particle ranges in tissue (40–100 µm). The ionizing-radiation Quantum Imaging Detector (iQID) is a high-resolution imaging system developed for quantitative digital autoradiography of alpha- and beta-particle emitters at these spatial scales. iQID combines scintillation-based detection with CMOS-camera imaging and real-time processing to localize individual particle interactions and record their spatial, temporal, and intensity information. Unlike phosphor imaging plate autoradiography, which integrates the cumulative signal from all radioactive decay events over an exposure, iQID detects and localizes individual scintillation events in real time. Event size, intensity, position, and time are retained as list-mode data, enabling high-resolution quantitative imaging of radioactive sources and radiolabeled tissue sections. Event characteristics can also distinguish alpha- and beta-particle interactions, allowing both emission types to be imaged simultaneously. The spatial and temporal information retained by iQID provides additional capabilities for characterizing radioactive sources. Changes in activity and decay behavior can be followed over time, and measured decay signatures can help distinguish radionuclides within mixed sources. This presentation will describe the iQID imaging approach and highlight applications in quantitative alpha/beta autoradiography, source characterization, isotope identification, radiopharmaceutical biodistribution, and micro-scale dosimetry.

AcknowledgmentResearch reported in this publication was supported by the NIBIB of the NIH under SBIR Award Number R44EB035459.
Keywords: Digital Autoradiography, Radiopharmaceutical Therapy, Alpha-Emitters
18:07 WS-04-15

How the next generation digital autoradiography can provide insight into theranostic bioequivalence (#3315)

S. Adler1

1 Frederick National Laboratory For Cancer Research, Clinical Research Directorate, Bethesda, Maryland, United States of America

Abstract

Introduction: Theranostic cancer treatments rely on ligands which can be tagged with two different isotopes. One for imaging and one for treatment. The imaging ligand is used as a proxy for monitoring the ligand used to treat the target tissue. Key to using the imaging agent to measure the dosimetry of the treatment ligand is knowing the bio-equivalence of the ligand pair. Bio-equivalence is defined as equal biological interaction of two ligands within tissue.  This can be achieved with the Quantitative Particle Identification Autoradiograph (QPID).

Materials and Methods: The next generation of spectral autoradiograph has been developed which mates a Timepix3 sensor developed by the CERN Medipix collaboration with a CeBr3 scintillation crystal. This allows one to use the gamma emission energy in forming autoradiograph images of tissue samples harvested in bio-distribution studies. The QPID time resolution is on the order of 1.6 ns allowing for the detection of single decays, thus achieving alpha and beta identification through ionization topology and energy deposition in the Timepix3 sensor, and spectral gamma emissions from the imaged sample.

Results: The QPID can segregate alpha and positron emissions, generating separate quantitative alpha and positron autoradiograph images from a sample which contains both an alpha and positron emitting ligand. This provides a mechanism to analyze co-injected theranostic imaging and treatment ligands. Using these separate images, one can measure the uptake and distribution in the same tissue sample. Furthermore, one can directly measure the pharmacokinetic properties of both ligands and measure their bio-equivalence.

Conclusion: Measuring any bio-equivalent deviation of the two ligands can be used to adjust the imaging agent activity and pharmacokinetic properties to more accurately be used as a proxy to measure the treatment effects and dosimetry results of the treatment ligand.

Acknowledgment

Funded by the NCI Contract No. 75N91019D00024.

Keywords: Digital Autoradiography, Theranostic Cancer Treatment
18:14 WS-04-16

Gamma-Positron Imaging and Event-Correlated Simulation for Emerging Theranostics (#3341)

M. A. Kupinski1, 2, M. King3, S. Abbaszadeh4, L. R. Furenlid1, 2

1 University of Arizona, College of Optical Sciences, Tucson, Arizona, United States of America
2 University of Arizona, Department of Medical Imaging, Tucson, Arizona, United States of America
3 University of Massachusetts Chan Medical School, Department of Radiology, Worchester, Massachusetts, United States of America
4 University of California, Santa Cruz, Baskin School of Engineering, Santa Cruz, California, United States of America

Abstract

PET and SPECT are often used even when radionuclides emit complementary radiations. Gamma-positron imaging exploits nuclides that emit a prompt gamma with a positron: annihilation photons define a PET line of response and prompt-gamma Compton interactions define a cone. Their intersection can estimate the radionuclide decay location more directly than PET alone.

We are developing a brain-dedicated gamma-positron imager using crossed-strip CZT detectors, event-correlated radiation transport, and GPU-accelerated list-mode reconstruction. The system records PET coincidences, prompt-gamma Compton events, and triple events in which both signatures arise from one decay. We evaluated event-class-specific LM-MLEM, conventional joint-Poisson reconstruction, and an event-type-conditioned method designed to preserve the localization value of triple events.

UAMonteCarlo preserves the lineage of prompt photons, positrons, annihilation photons, and secondaries from emission through detector interaction, allowing detector response, event classification, sensitivity, and reconstruction to be evaluated in one framework. In simulated 44Sc studies, all event classes localized point sources correctly. In a hot-rod phantom, rod-to-background contrast was 1.36 for PET-only, 1.14 for prompt-only, 4.93 for triple-only, 3.24 for conventional combined, and 3.86 for event-type-conditioned combined reconstruction, showing that triple events are uncommon but spatially informative.

The project also applies complete radiation-transport histories to emerging theranostic imaging. For 149Tb, gamma-positron events from the positron branch could image the same radiopharmaceutical responsible for alpha therapy. We are also applying the framework to 203Pb surrogate imaging for 212Pb-targeted alpha therapy. Together, these studies show how preserving decay and particle histories can inform detector design, reconstruction, quantitative imaging, and dosimetry.

AcknowledgmentThis work was supported by NIH UH3EB034686. 
Keywords: SPECT, PET, Gamma positron, Theranostics, Compton camera
18:21 WS-04-17

Multiplexed PET for Theranostic Imaging (#3342)

N. Encina-Baranda1, 2, A. Lopez-Montes3, E.C. Pratt4, T.-N. Nguyen5, A. Rominger3, L. Carter5, J. Cabello6, M. Conti6, H. Sari3, 7, K. Shi3, E. Körner8, F. Schmidt8, J.M. Udias1, J. Grimm5, J.L. Herraiz1, 2

1 Complutense University of Madrid, Dep. of Structure of the Matter. Nuclear Physics Group., Madrid, Spain
2 Hospital Clinico San Carlos, Health Research Institute, Madrid, Spain
3 Bern University Hospital, Dep. of Nuclear Medicine, Inselpital, Bern, Switzerland
4 Stony Brook Cancer Center, Dep. of Radiology, Stony Brook, New York, United States of America
5 Memorial Sloan Kettering Cancer Center, Dep. of Radiology, New York, New York, United States of America
6 Siemens Medical Solutions USA, Inc., Tennessee, Tennessee, United States of America
7 Siemens Healthineers International AG, Zurich, Switzerland
8 University of Tübingen, Dep. of Nuclear Medicine and Clinical Molecular Imaging, Tübingen, Germany

Abstract

Multiplexed PET (mPET) enables simultaneous imaging of multiple radiotracers in a single acquisition by exploiting radionuclide-specific signatures beyond conventional 511-keV annihilation photons. Positron–prompt gamma emitters such as 124I, 86Y, or 44Sc can generate triple coincidences that help distinguish them from pure positron emitters. This opens new opportunities for theranostic imaging, where complementary tracers could simultaneously characterize therapeutic targets and tumor biology, investigate intra- and inter-lesion heterogeneity, assess radiopharmaceutical biodistribution and dosimetry, or monitor early biological response to treatment. 

We present a modular mPET framework applicable to different radionuclides and scanners. It incorporates all the corrections and reconstructions required for quantitative PET while adapting to different scanner capabilities. When available, we exploit energy and time-of-flight information, while coincidence multiplicity alone provides radionuclide-specific information in more limited systems. The method also includes radionuclide-specific positron-range correction for each separated image. 

We quantitatively evaluated the approach with combinations such as 18F+124I, 18F+52Mn, 68Ga+86Y, and 89Zr+86Y across several preclinical and clinical PET scanners. Studies ranging 
from simultaneous tracer imaging in mice to multi-radionuclide phantom experiments demonstrated recovery of the individual radionuclide distributions across systems with different detector characteristics.

These results demonstrate the translation of mPET across PET scanners and radionuclide combinations. mPET could extend PET from a predominantly single-tracer technique toward a multidimensional molecular imaging platform in which complementary aspects of patient selection, treatment delivery, and response are interrogated within the same imaging session.

AcknowledgmentSupport from NIH R01-EB03300-02, Comunidad de Madrid TEC-2024/TEC-43, and Siemens Research Grant
Keywords: Multiplexed PET, Dual-Isotope, Quantitative Imaging