IEEE 2026 NSS MIC RTSD

Please note! All times in the online program are given in Madrid - Europe (CET) times!

Madrid - Europe ()
Oct 23, 2026, 10:16:31 PM
Your time ()
n/a
Madrid - Europe ()
Oct 23, 2026, 10:16:31 PM
Our Sponsors:

To search for a specific ID please enter the hash sign followed by the ID number (e.g. #123).

Novel detectors and associated technologies

Session chair: Ullan, Miguel, Dr. (IMB-CNM, Barcelona, Spain)
 
Shortcut: NSS-12
Date: Wednesday, 11 November, 2026, 9:00 - 11:00
Location: PICASSO
Session type: NSS Session

This session focuses on innovative detector concepts, materials, architectures, and enabling technologies. It aims to provide a forum for researchers and engineers to present the latest developments and discuss future directions in detector technologies and their associated systems.

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

9:00 NSS-12-01

PLATON: a plenoptic single-photon camera with sub-nanosecond time resolution for particle detection through monolithic scintillating volumes (#1339)

T. Dieminger1, S. Alonso-Monsalve1, K. Kaneyasu2, M. Barbieri4, V. Berardi3, C. Bruschini2, E. Charbon2, D. Sgalaberna1

1 ETH Zurich, Zurich, Zürich, Switzerland
2 EPFL, Lausanne, Vaud, Switzerland
3 Politecnico di Bari, Bari, Italy
4 Università degli Studi Roma Tre, Rome, Italy

Abstract

High-resolution scintillator detectors achieve precise particle tracking through fine segmentation down to a few hundred micrometres, making complexity and costs prohibitive when scaling up to large volumes. We propose a change of paradigm: 3D imaging of particle interactions in an unsegmented monolithic volume of scintillator obtained by combining plenoptic imaging with a Single-Photon Avalanche Diode (SPAD) array sensor. We report the performance of the first SPAD-based plenoptic camera for particle detection, built around the SwissSPAD2 sensor. Results obtained from 90Sr radioactive source, a point light source and a controlled two-photon-absorption setup as well as novel analytical and artificial-intelligence-driven 3D imaging techniques will be described. A simulation case study on neutrino detection demonstrates the unique potential of this approach and its scalability to medium (1 x 1 x 1 m3) and large (10 x 10 x 10 m3) scale scintillator volumes, with sub-millimeter 3D spatial resolution. A new custom SPAD array required to enhance the resolution currently under development is also presented. This work sets the path forward for a new system for high-precision particle tracking in dense volumes. Applications of the PLATON concept can also extend to medical imaging.

AcknowledgmentThis work was supported by Swiss National Science Foundation under grants PCEFP2_203261 and 20QT21_187716 Qu3D ``Quantum 3D Imaging at high speed and high resolution"), the National Energy Research Scientific Computing Center (NERSC), a U.S. Department of Energy User Facility, under the AI4Sci@NERSC award DDR-ERCAP0034642, Swiss AI Initiative grant from the Swiss National Supercomputing Centre (CSCS), project ID a149, on the Alps system.
References
[1] A. Blondel et al., JINST, vol. 13, no. 02, pp. P02 006–P02 006, feb 2018
[2] S. Abe et al., arXiv:2603.14921 [physics.ins-det]
[3] A. Agarwal et al., Phys. Lett. B, vol. 840, p. 137843, 2023
[4] C. Joram et al., Tech. Rep., 2015
[5] T. Dieminger et al., Nature Communications, vol. 17, no. 1, p. 4204, 2026
[6] Ulku et al., IEEE Journal of Selected Topics in Quantum Electronics, vol. 25, pp. 1–12, 1 2019
[7] K. Kaneyasu et al., Platon SPAD: A scalable sensor for elementary particle detection NSS-MIC 2026 - abstract ID #1496
Keywords: Particle detector, neutrino, Light field camera, 3D imaging
9:15 NSS-12-02

A Capacitively Coupled GaAs SAM-APD with Cross-Delay Lines for Fully Digital 3D Hard X-ray Photon Imaging (#1810)

N. Lusardi1, 7, F. Arfelli3, 2, G. Biasiol4, F. Driussi8, M. Antonelli2, M. Cautero3, 5, M. Colja5, F. Garzetti1, G. Cautero5, 2, R. H. Menk5, 2, A. Costa1, G. Fiumicelli1, E. Ronconi1, G. Bonanno1, G. Brajnik5, S. Carrato6, D. Curcio4, S. Dal Zilio4, D. Ercolani4, A. Geraci1, 7, A. Pilotto8, L. Sbuelz4, R. Sergo5, L. Stebel5

1 Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy
2 INFN, Trieste, Trieste, Italy
3 University of Trieste, Department of Physics, Trieste, Italy
4 CNR, ISTITUTO OFFICINA DEI MATERIALI, Trieste, Italy
5 Elettra Sincrotrone, Trieste, Italy
6 University of Trieste, DIA, Trieste, Italy
7 INFN, Milano, Milano, Italy
8 Università degli Studi di Udine, DPIA, Udine, Italy

Abstract

Time-resolved ultrafast phenomena with hard X-rays are central to applications such as pump–probe spectroscopy, driving advances in detector and multichannel acquisition technologies. This work proposes a fully digital 3D (x–y–time) imager for hard X-rays. Key challenges include improving time and spatial resolution—often limited by pixelated approaches—and overcoming the low quantum efficiency of silicon detectors at high photon energies. To address these issues, we adopt a Separate Absorption and Multiplication Avalanche Photodiode (SAM-APD) based on III–V semiconductors. GaAs alloys, with higher atomic number and carrier mobility than silicon, enable significantly improved absorption efficiency and faster response. On the readout side, the shift toward multichannel systems and stringent constraints on power and area per channel motivate a transition from voltage-mode pixel electronics to time-based acquisition, where spatial (x, y) and temporal information are encoded in the detection time. The proposed architecture couples a large-area GaAs SAM-APD (mm-scale diameter) with two Cross Delay Lines (CDLs) and a 4-channel Field-Programmable Gate Array (FPGA)-based Time-to-Digital Converter (TDC) with 15 ps precision. The main challenges are preserving spatial coherence between the interaction point on the detector and the corresponding charge readout location on the CDL, and ensuring capacitive coupling with high signal integrity. Preliminary tests were performed using a 10 × 5 mm² p–i–n diode and laser pulses achieving a spatial precision of <100 μm r.m.s. and a temporal jitter of 68.3 ps r.m.s. Additional measurements show intensity discrimination capability with resolvable signal changes of ~1.2–1.6×. The approach offers a compact and scalable alternative to pixelated detectors, eliminating the need for advanced lithography and per-pixel readout, while relying on only four acquisition channels.

AcknowledgmentThe work is supported by PRIN 2022 - Code 20227N9LW7
References
[1] F. Capasso et al., “Enhancement of electron impact ionization in a superlattice: A new avalanche photodiode with a large ionization rate ratio,” Applied Physics Letters, vol. 40, no. 1, pp. 38–40, 01 1982. [Online]. Available: https://doi.org/10.1063/1.92910
[2] J. Lauter et al., “Algaas/gaas sam-avalanche photodiode: An x-ray detector for low energy photons,” Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 356, no. 2, pp. 324–329, 1995. [Online]. Available: https://www.sciencedirect.com/science/article/pii/0168900294012377
[3] N. Lusardi et al., “Advanced system in fpga for 3d (x, y, t) imaging with cross delay-lines,” in 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2019, pp. 1–4.
Keywords: GaAs-based avalanche photodiodes, Separate Absorption and Multiplication Avalanche PhotoDiode (SAM-APD), Cross Delay-Line (CDL), time-resolved experiments., Hard X-rays detectors
9:30 NSS-12-03

Characterization of 4H-SiC implanted LGADs after 23 MeV Proton Irradiation (#1845)

F. Moscatelli1, 2, A. Morozzi2, V. Sola3, D. Passeri4, P. Svihra5, 6, R. Novotny5, V. Kracmar5, J. Kroll6, B. Regnery7, R. White8, M. Ferrero8, M. Tornago3, 8, A.R. Altamura3, 8, M. Bruzzi9, S. A. Onder10, A. Dierlamm7, T. Bergauer10

1 CNR-Istituto Officina dei Materiali (IOM), Perugia, Italy
2 INFN of Perugia, Perugia, Italy
3 University of Torino, Department of Physics, Torino, Italy
4 University of Perugia, Department of Engineering, Perugia, Italy
5 FNSPE CTU in Prague, Department of Physics, Prague, Czech Republic
6 FZU CAS, Department of Detector Development and Data Processing, Prague, Czech Republic
7 Karlsruhe Institute of Technology, Karlsruhe, Baden-Württemberg, Germany
8 INFN Torino, Torino, Italy
9 University of Florence, Department of Physics and Astronomy, Firenze, Italy
10 MBI for Particle Physics, Wien, Austria

Abstract

The demand for radiation-hard 4D detectors capable of simultaneous high-precision timing and spatial resolution is driving the investigation of 4H-Silicon Carbide (4H-SiC) as a robust alternative to silicon. While 4H-SiC offers superior thermal stability and radiation tolerance, its wide bandgap and current epitaxial thickness limits necessitate the use of internal charge multiplication. This work presents an extensive performance evaluation of 4H-SiC LGADs and PN junction diodes fabricated by Onsemi on 6-inch wafers 50 μm epitaxial layer, n=5 ·1013  cm-3. The devices were subjected to 23 MeV proton irradiation, covering five fluences from 1.3 ·1014 to 2 ·1015 p/cm2. They have been characterized in terms of current–voltage I-V and capacitance–voltage C-V measurements. The study is complemented by ongoing Transient Current Technique (TCT) and Charge Collection Efficiency (CCE) measurements using a beta source. Furthermore, the impact of temperature (up to 200°C for I-V/C-V and 100°C for beta tests) is investigated to evaluate defect dynamics and the operational stability of 4H-SiC LGADs in extreme environments.

AcknowledgmentThis work was supported by INFN CSN5 with the SiC4GAIN research project
Keywords: 4H-SiC, low-gain avalanche detector (LGAD), proton radiation, Radiation detectors, Semiconductor Diodes
9:45 NSS-12-04

Status of GRAiNITA, a next generation calorimeter (#1928)

H. Chanal1, D. Abbaneo5, S. Barsuk2, O. Bezshyyko4, I. Boyarintseva2, 3, A. Boyarintsev3, D. Breton2, M. DeFranchis5, A.M. Dubovik3, L. Golina-Bezshyyko4, D. d’Enterria5, B. François5, Y. Hou1, F. Guo5, G. Hull2, P. Janot5, D. Klekots4, 2, A. Kotenko4, J. Lefrançois2, J. Maalmi2, M. Magne1, A.D. Tinoco Mendes5, S. Monteil1, E. Perez5, D. Picard1, M.-H. Schune2, M. Selvaggi5, N. Semkiv4, I. Tupitsyna3, M. Yeresko2

1 Université Clermont Auvergne, LPCA, CNRS/IN2P3, Clermont-Ferrand, France
2 Université Paris-Saclay, ,IJCLab, CNRS/IN2P3, Saclay, France
3 Institute for Scintillation Materials of the National Academy of Sciences of Ukraine, Kharkiv, Ukraine
4 Kyiv National Taras Shevchenko University, Kyiv, Ukraine
5 CERN, European Organization for Nuclear Research, Geneva, Switzerland

Abstract

The GRAiNITA project aims to develop a novel design for a next-generation calorimeter. It is an innovative approach which uses a mixture of millimeter-sized inorganic scintillating crystals (approximately 1-2 mm) dispersed within a high-density, transparent liquid. Compared to other sampling calorimeter with sensitive material of plastic scintillator, liquid argon, or silicon detector the sampling fluctuation impact on the resolution is predicted by simulation to be much smaller (<2%/sqrt{E}) due to the high density of the scintillator grains compared to the liquid and the smallness of the grains. A test beam operated in June 2024 at CERN allowed to study the performance of a small-scale GRAiNITA prototype. The light light yield was confirmed to be approximately 10 kPE/GeV and we demonstrated the feasibility of achieving sub-2% stochastic and constant terms. Since, the project has advanced significantly. This article presents the latest developments, including the design of a full-scale demonstrator module, advanced Geant4 simulations which are used to evaluate its expected performance, and detailed characterization studies scintillation properties of ZnWO$_4$ using proton beams. These efforts pave the way for the comprehensive validation of a full-scale detector.

Keywords: Test-beam, Calorimeter, Geant4, Scintillator, FCC
10:00 NSS-12-05

Small Dose Monitor based on Silicon Carbide diodes for FLASH radiotherapy (#2594)

C. Fleta1, I. López1, Á. Henao1, S. Heinrich2, C. Guardiola1

1 National Center of Microelectronics (IMB-CNM, CSIC), Barcelona, Spain
2 University Paris-Saclay, Orsay, France, Institut Curie, Inserm U1021-CNRS UMR 3347, Orsay, France

Abstract

FLASH radiotherapy (FLASH RT), delivered at ultra-high dose rates (>40 Gy/s), has shown potential to reduce toxicity in healthy tissues while preserving tumor control. However, accurate, real-time dosimetry at such conditions remains challenging due to limitations of conventional detectors, including saturation effects and insufficient temporal resolution. In this work, silicon carbide (SiC) diodes are investigated as a promising solution for ultra-high dose rate (UHDR) dosimetry due to their high radiation hardness, fast response, and low sensitivity to saturation [1].

A 4 × 4 array of SiC diodes (1 mm diameter, 2.2 mm pitch) and a single 2.2 mm diode were tested using pulsed 7 MeV electron beams under FLASH conditions. The detectors were evaluated in terms of linearity, time response, and spatial dose measurement capabilities using a clinical reference dosimeter and radiochromic films for comparison. The single diode demonstrated excellent linearity better than 3.5% up to 10 Gy per pulse, with no evidence of saturation or radiation damage. Time-resolved measurements confirmed the capability to resolve sub-microsecond pulse structures, consistent with accelerator signals.

The SiC array prototype enabled spatially resolved dose measurements over areas up to 70 × 50 mm², producing 2D dose maps with millimeter-scale resolution under UHDR conditions. Good agreement with independent film measurements demonstrates its accuracy for beam profiling. These results highlight the feasibility of SiC-based detectors as scalable, position-sensitive dose monitors for FLASH RT [2].

Overall, this work demonstrates the potential of SiC technology for real-time, high-resolution dosimetry in FLASH radiotherapy, paving the way for future large-area detector systems and improved quality assurance in UHDR treatments.

AcknowledgmentThe project has received support from the Spanish government through the ‘María de Maeztu Unit of Excellence’ accreditation (CEX2023-001397-M / AEI/10.13039/501100011033).
References
[1] Fleta C, Pellegrini G, Godignon P, et al. State-of -the-art silicon carbide diode dosimeters for ultra-high dose-per-pulse radiation at FLASH radiotherapy. Phys Med Biol. 2024;69(9):095013. doi:10.1088/1361-6560/ad37eb
[2] Lopez Paz I, Fleta C, Henao Á, Heinrich S, Guardiola C. Small dose monitor based on silicon-carbide diodes for FLASH radiotherapy. Med Phys. 2026 Mar;53(3):e70354. doi: 10.1002/mp.70354. PMID: 41757409; PMCID: PMC12947054.
Keywords: Silicon Carbide, FLASH therapy, dosimetry
10:15 NSS-12-06

Thin-Film and Single-Crystal Perovskite Detectors for Real-Time FLASH Radiotherapy (#2664)

M. Bruzzi1, 2, L. Baldesi1, 2, L. Basiricò7, 10, M.G. Bisogni3, 4, G. Casini1, A. Cavalieri8, 9, C. Civinini1, L. Forcieri2, 1, B. Fraboni7, 10, F. Di Martino6, 8, A. Vinattieri1, E. Verroi5

1 INFN - Istituto Nazionale di Fisica Nucleare, Sezione di Firenze, Firenze, Italy
2 Università di Firenze, Firenze, Italy
3 Università di Pisa, Pisa, Italy
4 INFN - Istituto di Fisica Nucleare, Sezione di Pisa, Pisa, Italy
5 INFN - Istituto di Fisica Nucleare, TIFPA - Sezione di Trento, Trento, Italy
6 Unit of Medical Physics, Pisa University Hospital, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy
7 Università di Bologna, Bologna, Italy
8 Centro Pisano ricerca e implementazione clinica Flash Radiotherapy (CPFR@CISUP), Pisa, Italy
9 Center for Instrument Sharing of the University of Pisa (CISUP), University of Pisa, Pisa, Italy
10 INFN- Istituto di Fisica Nucleare, Sezione di Bologna, Bologna, Italy

Abstract

Ultra-high dose rate (UHDR) radiotherapy, commonly known as FLASH radio-therapy, is a revolutionary oncological approach that spares healthy tissue while preserving tumor control. Clinical translation of this method needs radiation detectors that provide real-time dosimetry under extreme dose rates, exceeding 40-100 Gy/s. Standard dosimeters, such as ionization chambers and traditional semiconductors, may face limitations like charge recombination and signal saturation in these environments. This study investigates full-inorganic metal-halide perovskites (CsPbBr3) as viable detector material due to its high stopping power and moderately wide bandgap. We evaluated two distinct device architectures: thin-film (TF) and single-crystal (SC) detectors. The 1 μm-thick TF detectors were fabricated using radio-frequency magnetron sputtering (MS) on flexible Kapton substrates with interdigitated electrodes. SC detectors featured Schottky-Ohmic electrodes (Ti/Au and Au) deposited by DC-MS on pure commercial crystals. Characterization indicated a dominant CsPbBr3 phase, a forbidden gap of 2.32 eV, and a dark resistivity of approximately 107 Ωcm. Experimental validation was performed using a 9 MeV electron beam at Centro Pisano FLASH Radiotherapy (CPFR) and a 228 MeV proton beam at APSS (Azienda Provinciali Servizi Sanitari) Trento proton-therapy center. The tests with 9MeV electron beams covered a dose-per-pulse (DPP) range of 0.1 to 5.0 Gy delivered in 4us-long pulses, while proton testing reached dose-rates of 300 Gy/s with pulse durations of 10-25ms. Both detector types demonstrated good signal linearity and showed no evidence of saturation at the highest tested intensities. Ultimately, these results confirm that CsPbBr3 perovskite detectors are suitable for real-time monitoring in both electron and proton FLASH radiotherapy.

Acknowledgment

Work performed under the framework of the PROVIDE CSN5 project. We thank Fondazione Pisa for funding CPFR with the grant prog. n.134/2021

References
[1] V. Favaudon, L. Caplier, V. Monceau, F. Pouzoulet, M. Sayarath, C. Fouillade et al, “Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice” Sci translational Med., Vol. 6,  2014.
[2] Pablo P. Yepes, Solid-State Detector for FLASH Radiotherapy: Dosimetric Applications and Emerging Concepts, Condens. Matter 11, 2026, 3.
[3] H. Wei, J. Huang, Halide lead perovskites for ionizing radiation detection. Nat Commun Vol. 10, 2019, p. 1066.
[4] M. Bruzzi, L. Forcieri, C. Civinini, A.  Vinattieri, L. Basiricò, B. Fraboni Development of thin-film inorganic perovskite UV photodetectors, in press on JINST.
[5] F. Di Martino et al. “Architecture, flexibility and performance of a special electron linac dedicated to Flash radiotherapy research: electronFlash with a triode gun of the centro pisano flash radiotherapy (CPFR)”, Front. Phys.. Sec. Medical Physics and Imaging Vol. 11 Nov. 2023.
Keywords: perovskites, thin-films, detectors, dosimeters, FLASH radiotherapy
10:30 NSS-12-07

Particle-by-Particle Characterization of Clinical Carbon Ion Beams with a Silicon Strip Detector and High-Rate DAQ Systems (#3038)

F. Mas Milian1, M. Fadavi Mazinani1, P. Cerello1, S. De Astis1, 2, M. D. Fernandez Moreira1, V. Ferrero1, 2, E. Fiorina1, D. Montalvan Olivares1, 2, F. Pennazio1, M. Pullia3, S. Ranjbar1, 2, I. B. Rivas Ortiz1, R. Sacchi1, 2, A. Vignati1, 2, S. Giordanengo1

1 Istituto Nazionale di Fisica Nucleare, Section Torino, Torino, Italy
2 Università di Torino, Department of Physics, Torino, Italy
3 Centro Nazionale di Adroterapia Oncologica, Pavia, Italy

Abstract

At CNAO, carbon-ion beams are delivered by the standard scheme which uses betatron-core extraction of a debunched beam, while RF Knock-Out (RFKO) extraction keeps the beam bunched and drives particles transversely toward extraction. To resolve the fine temporal structure of these modes beyond the 100 ms limit of standard ESA‑ABACUS readout, a High‑Rate DAQ system with 10 ns time bins was developed. The system used the LVDS outputs of 48 central channels from two ABACUS ASICs connected to a Xilinx Kintex-7 FPGA implementing custom VHDL firmware. Counts were aggregated in 10 ns windows, stored in DDR3 memory, and analyzed offline to reconstruct beam-rate waveforms and frequency components.

Tests were performed at CNAO with clinical carbon-ion beams using Betatron and RFKO extraction at four energies (115, 209, 304, and 398 MeV/u) and three intensity levels (20%, 50%, 100%). 
A CAEN DT5203 picoTDC was also used as an independent acquisition system to record leading- and trailing-edge timing information from 32 ESA-ABACUS outputs in Streaming mode. The High-Rate DAQ resolved clear differences between the two extraction modes: RFKO showed a more compact and regular bunched time structure, while Betatron extraction showed the broader temporal distribution expected from a debunched coasting beam. Fast Fourier Transform analysis of the High-Rate DAQ waveforms allowed the main accelerator RF components to be estimated with deviations below 0.25% for all tested conditions.
The DT5203 provided complementary hit‑by‑hit timing and enabled bunch‑spacing estimation with <1.5% deviations, but suffered rate saturation at high intensities.
Overall, the High‑Rate DAQ proved suitable for fine beam‑structure measurements under clinical carbon‑ion conditions, supporting accelerator tuning, particularly for RFKO operation.

Acknowledgment This research was supported by the INFN CSN5 project SIG and SIG PNR funding.
References
[1] E. Bressi, L. Falbo, C. Priano, S. Foglio, Betatron Core Slow Extraction at CNAO, IPAC2018.
[2] S. Savazzi et al., Implementation of RF-KO Extraction at CNAO, IPAC2019.
[3] E. M. Data et al, “Characterization of a 144-channel front-end board for ion beam counting in particle therapy,” Nuclear Instruments and Methods in Physics Research A 1080 (2025) 170712
[4] E. Data et al. “A novel detector for 4D tracking in particle therapy” Nuclear Instruments and Methods A,1068 (2024) 169690
Keywords: clinical carbon ions, high-rate beam monitor, multichannel readout, particle-resolved beam time structure, thin silicon strip detector.
10:45 NSS-12-08

Diamond Quantum Sensor for High Fluence Neutron Detection (#3048)

L. Shoen1, Y. Tong2, J. Lanza1, J. Choy2, R. Cao1

1 The Ohio State University, Nuclear Engineering, Mechanical and Aerospace Engineering, Columbus, Ohio, United States of America
2 University of Wisconsin at Madison, Electrical and Computer Engineering, Madison, Wisconsin, United States of America

Abstract

This work investigates diamond nitrogen-vacancy (NV) centers as a new class of neutron dosimetry that uses neutron-induced defect formation as the sensing mechanism rather than treating radiation damage as a failure mode. There is no device fabrication, wire connection, or charge collection as the diamond works purely as a passive dosimeter. Fast neutrons generate carbon vacancies in nitrogen-enriched diamond, followed by high-temperature annealing to form stable NV centers exhibiting characteristic photoluminescence and optically detected magnetic resonance responses. Eight nitrogen-rich diamond samples were irradiated at The Ohio State University Research Reactor, with fluence ranging from 1015 n/cm2 to 1017 n/cm2, and then annealed at 800 °C for a few hours.  The results demonstrated a strong linear correlation between fluorescence intensity and neutron fluence, with up to 403× fluorescence increase observed after annealing compared to control samples. The results support the feasibility of applying diamond as compact, passive, and radiation-hardened sensors for high-fluence neutron detection in nuclear fission and fusion systems. The ongoing work is also exploring the real-time sensing using a diamond quantum sensor.

AcknowledgmentThis research is supported by the U. S. Department of Energy/National Nuclear Security Administration under Award Number DE-NA0004196 for the ETI consortia and is also partially supported by Helion Energy.
Keywords: Diamond NV Center, Quantum Sensor, Neutron Detection, Neutron Flux, Reactor Dosimetry


Our Exhibitors: