Scintillators

Session chair: Terragni, Giulia, Dr.; Glodo, Jarek, (Radiation Monitoring Devices, Inc, USA)
 
Shortcut: NSS-16
Date: Wednesday, 11 November, 2026, 15:00 - 17:00
Location: PICASSO
Session type: NSS Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

15:00 NSS-16-01

Asymmetry in time difference histograms for scintillators with different decay constants in coincidence (#2202)

A. Hamato1, 2, N. Kratochwil2, R. Ota2, 4, J. Glodo3, T. Yamaya1, S.R. Cherry2, S.I. Kwon2

1 National Institutes for Quantum Science and Technology (QST), Advanced Nuclear Medicine Sciences, Chiba, Japan
2 University of California Davis, Biomedical Engineering, Davis, California, United States of America
3 Radiation Monitoring Devices Inc., Watertown, Massachusetts, United States of America
4 Hamamatsu Photonics K.K, Central Research Laboratory, Hamamatsu, Japan

Abstract

Coincidence timing resolution is a critical performance parameter in time-of-flight PET and other timing sensitive applications. The timing performance of scintillation detectors is governed by intrinsic scintillator properties such as light yield, rise time, and decay constant. When detectors with different scintillation characteristics are in coincidence, these differences can distort the coincidence timing spectrum, leading to deviations from an ideal symmetric Gaussian distribution. Differences in scintillator decay constants can introduce measurable asymmetry in coincidence timing histograms. In this work, the influence of scintillator decay constant on coincidence timing histogram was investigated using several scintillators with different decay constants. The scintillators (Lu2O3:Yb, EPS-100 plastic scintillator, LaBr3:Ce, LYSO:Ce, GAGG, NaI:Tl, and BGO) with dimensions of 3×3×5 mm3 mounted on identical silicon photomultipliers were placed in coincidence with a reference LYSO detector. Time difference histograms were acquired for each detector pair and quantitatively analyzed using the mean, median, and skewness of the measured distributions. The results showed nearly symmetric timing histograms for EPS-100, LaBr3, and LYSO scintillators, whereas other scintillators exhibited increasing asymmetry. The longest tail was observed for BGO on one side of the histogram. Time difference histograms were also analytically calculated based on the arrival time distribution of the 10th detected photon. The analytical results reproduced the main trends observed experimentally. These findings demonstrate that scintillator decay constants significantly influence the shape and asymmetry of coincidence timing histograms for non-identical detector pairs with substantially different decay constants, providing insight relevant to the design and optimization of mixed scintillator timing systems.

AcknowledgmentThis work was supported by the National Institutes of Health under grant R01 EB030538.
References
[1] T. V. D Herman et al., Phys. Med. Biol., 58, 3243, 2013.
[2] S. Gundacker et al., J. Inst., 8, P07014, 2013.
[3] F. Acerbi et al., J. Inst., 10, P07014, 2015.
[4] M. Piller et al., Phys. Med. Biol., 69, 115014, 2024.
[5] R. Ota et al., arxiv:2510.03488, 2025.
Keywords: time difference histogram, scintillation detector, decay constant, asymmetric behavior, time-of-flight
15:15 NSS-16-02

Ultrafast and Efficient 2D Perovskite Scintillators for Sub-50 ps TOF-PET and High-Resolution X-ray Imaging (#2541)

J. Liu1

1 Wuhan University of Technology, School of Materials Science and Engineering, Wuhan, China

Abstract

Ultrafast radiation detection has been persistently limited by the formidable challenge of achieving scintillators that combine sub-nanosecond response times with high scintillation efficiency. Here, we identify atomic-level exciton confinement, achieved through the synergistic regulation of A-site organic cations in 2D perovskites, as a critical factor for breaking this performance bottleneck. The resulting (1,4-CMA)PbBr4 crystals exhibit a rare combination of a 0.62 ns radioluminescence decay time and a high light yield of 19,730 photons/MeV, surpassing leading commercial benchmarks such as BaF2 and LYSO:Ce. Detectors based on this material achieved a record-breaking coincidence timing resolution (CTR) of 43.3 ps for reconstruction-free Time-of-Flight Positron Emission Tomography (TOF-PET) and a high spatial resolution of 32.3 lp mm-1 for X-ray imaging. These results establish rational lattice distortion engineering as a key principle for the development of high-performance, scalable perovskite scintillators for next-generation medical and industrial imaging.

Keywords: ultrafast radiation detection, scintillator, 2D perovskites, TOF-PET, x-ray imaging
15:30 NSS-16-03

Thick Optical-guiding Scintillator with Enhanced Crystal Quality for High-Resolution and High-Sensitivity X-ray Imaging (#2557)

Y. Nakata1, 2, K. Kamada3, 2, M. Yoshino2, 3, T. Kudo4, R. Murakami2, S. Ishizawa2, Y. Yokota2, 3, A. Yoshikawa2, 3

1 Tohoku University, Department of Materials Science / Graduate School of Engineering, Sendai, Japan
2 Tohoku University, Institute for Materials Research, Sendai, Japan
3 Tohoku University, New Industry Creation Hatchery Center, Sendai, Japan
4 C&A Corporation, Sendai, Japan

Abstract

This study presents the fabrication and evaluation of an Optical-guiding Crystal Scintillator (OCS), a structured scintillator that achieves both high spatial resolution and high detection sensitivity in X-ray imaging. Conventional scintillators face a trade-off between these two properties, and structured scintillators have been developed to overcome this trade-off. However, simultaneously achieving fine waveguiding channels with sufficient thickness at bulk scale remains a challenge. The OCS has been proposed to address this issue [1–2]. It has regularly arrayed single-crystal scintillator cores embedded in a low-refractive-index glass cladding. Each core confines scintillation light by total internal reflection. In this work, we grew Tl-doped Cs3Cu2I5 (CCI:Tl, n = 1.92) single-crystal cores through directional solidification from a melt within the 5 µm-diameter channels of a borosilicate glass plate (n = 1.47). Electron backscatter diffraction analysis of the cross-section sample confirmed that each core is a single crystal, and X-ray-excited radioluminescence showed an emission peak at 517 nm, consistent with previously reported values for CCI:Tl single crystals [3]. We evaluated spatial resolution by imaging test charts with a microfocus X-ray tube and calculating the contrast transfer function (CTF). A 500 µm-thick OCS achieved CTF = 35% at 10 lp/mm, compared with 10% for a commercial CsI:Tl columnar scintillator of the same thickness. The OCS maintained spatial resolution over a thickness range of 200 to 700 µm, whereas the commercial scintillator exhibited a sharp decline. Light yield was higher than that of the commercial CsI:Tl columnar scintillator. These results demonstrate that the OCS overcomes the conventional trade-off between spatial resolution and detection sensitivity, opening new possibilities for high-energy X-ray imaging, industrial nondestructive testing, and medical diagnostics.

References
[1] Ryuga, Yajima, Akira, Yoshikawa, et al., 2023, ‘Prototype fabrication of optical-guiding Tl:CsI crystal scintillators and investigation of the crystallization process’, Jpn. J. Appl. Phys., vol. 62, p. SC1064.
[2] Kei, kamada, et al.,  2026, ‘Development of Optical-Guiding Scintillators with Ultrafine (~12 μm) Uniform Scintillator Cores for High-Resolution X-Ray Imaging’, Materials, vol. 19, no. 9, p. 1834.
[3] Yuan, Dongsheng, 2020, ‘Air-stable bulk halide single-crystal scintillator Cs3Cu2I5 by melt growth: Intrinsic and Tl doped with high light yield’, ACS Appl. Mater. Interfaces, vol. 12, no. 34, pp. 38333–38340.
Keywords: Cesium copper iodide, Structured scintillator, X-ray imaging
15:45 NSS-16-04

Development of 3D-Printable Plastic Scintillator Using Stereolithography for Radiation Detection Applications (#1653)

K. Puprasit1, 2, N. Mattayom1, K. Chaiwongkhot3, K. Amratisha3, A. Phunpueok4, N. Udee5

1 Chulabhorn Royal Academy/Princess Srisavangavadhana Faculty of Medicine/Medical Physics Program, Bangkok, Thailand
2 Chulabhorn Royal Academy/Personalized Radiotherapy and Imaging in Medicine (PRIME) Excellent Research Group, ฺBangkok, Thailand
3 Mahidol University/Faculty of Science/Department of Physics, ฺBangkok, Thailand
4 Rajamangala University of Technology Thanyaburi/Faculty of Science and Technology/Division of Physics, Pathum Thani, Thailand
5 Naresuan University/Faculty of Allied Health Sciences/Department of Radiological Technology, Phitsanulok, Thailand

Abstract

Plastic scintillators are widely used in radiation detection; however, conventional fabrication constrains detector geometry to simple shapes, limiting applicability in complex dosimetry configurations. We report the development of a geometrically flexible plastic scintillator fabricated via stereolithography (SLA) 3D printing, enabling arbitrary-geometry detector production. The formulation incorporated vinyltoluene (VT, 0–20 wt%) as an aromatic co-monomer, 2,5-diphenyloxazole (PPO, 1–2 wt%) as the primary fluorophore, 1,4-bis(2-methylstyryl)benzene (Bis-MSB, 0–0.01 wt%) as a wavelength shifter, and TPO as the photoinitiator in a commercial acrylate photopolymer host matrix. A post-print resin-dipping technique using the identical formulation improved optical transmittance from 11% to 72%. Main-effect analysis across nine formulations showed that VT at 10 wt% yields optimal optical clarity (~72% at 800 nm), while PPO at 2.0 wt% produces the highest emission intensity at 367–368 nm without concentration quenching. Self-absorption arising from PPO emission–absorption spectral overlap and a host-resin transmission cut-off at 410 nm was identified as the primary optical challenge, establishing Bis-MSB wavelength shifting as essential for light collection beyond the cut-off. Active scintillation was confirmed under Sr-90 via silicon photomultiplier (SiPM) readout, with pulse amplitude 20 times lower than EJ-200. Dosimetric characterization under Cs-137 and Co-60 with EJ-200 benchmarking will be presented.

Acknowledgment

This research was supported by the NSRF via the Research and Innovation Acceleration Agency for Competitiveness and Area Development (RCAD), Program Management Unit for Technology and Innovation for Future Industries (PMU-B): Brainpower for Future Industries (grant number B39G690003). The authors also acknowledge the support of the Personalized Radiotherapy and Imaging in Medicine (PRIME) Excellent Research Group, Chulabhorn Royal Academy, Bangkok, Thailand.

References
[1] J. B. Birks, The Theory and Practice of Scintillation Counting. Oxford: Pergamon, 1964.
[2] M. Nikl et al., "Synthesis and development of a vinyltoluene-based plastic scintillator," J. Lumin., vol. 193, pp. 1–6, 2018.
[3] R. R. Raylman et al., "Evaluation of advanced methods and materials for construction of scintillation detector light guides," Front. Phys., vol. 9, 2021.
[4] K. Yoon et al., "Fast-, light-cured scintillating plastic for 3D-printing applications," J. Nucl. Eng., vol. 4, no. 1, pp. 241–257, 2023.
[5] M. Hamel et al., "Preparation and characterization of cross-linked plastic scintillators," Polymer, vol. 207, p. 122906, 2020.
[6] T. Kaptanoglu et al., "Fluorescence quantum yield of bis-MSB," arXiv:1506.00240, 2015.
[7] Eljen Technology, "EJ-200 Data Sheet." [Online]. Available: https://eljentechnology.com
[8] A. Sharma et al., "Novel epoxy-bPBD-BisMSB composite plastic scintillator," Sci. Rep., vol. 14, p. 6640, 2024.
Keywords: plastic scintillator, stereolithography, 3D printing, radiation dosimetry, photon beam
16:00 NSS-16-05

Energy Spectroscopy Using Tin-Loaded Organic Glass Scintillators of Varying Sizes (#2113)

E. Neely1, 2, E. Schneider2, C. Sosa3, S. Clarke2, S. Pozzi2

1 University of Michigan, Department of Applied Physics, Ann Arbor, Michigan, United States of America
2 University of Michigan, Department of Nuclear Engineering and Radiological Sciences, Ann Arbor, Michigan, United States of America
3 Radiation Monitoring Devices, Boston, Massachusetts, United States of America

Abstract

Organic scintillators doped with heavy metals are promising for nonproliferation work as they combine the low-Z sensitivity to neutrons with the high-Z sensitivity to photoelectric absorption of gammas. Organic glass scintillators (OGS), in particular, are easy to shape and perform almost as well as trans-stilbene in light yield, energy resolution, and pulse shape discrimination. The Detection for Nuclear Nonproliferation Group (DNNG) at the University of Michigan has already completed work on 6-mm and 12-mm cubes of the tin-loaded OGS (or Sn-OGS), finding good agreement between experimental results and MCNP simulations of reasonable fidelity. The measured energy resolution of the photopeak from the 12-mm Sn-OGS is on the order of 10% and the intrinsic efficiency is visible on a log scale, both with uniform energy-dependent trends. DNNG and RMD have just entered into an agreement to further investigate this material in the form of a 1” x 1” cylinder. We anticipate that similar basic gamma spectroscopy will reveal increased photopeak efficiency and a diminished X-ray escape peak as multiple scatters are more likely in a larger volume; however, the effect of detector volume on energy resolution is unknown. In addition, we hope to present data from Compton coincidence experiments, and begin work with gamma/neutron sources for pulse shape discrimination. This work will also be compared to MCNP simulations.

AcknowledgmentThis work was supported in part by the Consortium for Monitoring, Technology, and Verification under Department of Energy National Nuclear Security Administration, award number DE-NA0003920.
Keywords: gamma spectroscopy, organic glass scintillator, high-Z dopants, photopeak, tin-loaded glass
16:15 NSS-16-06

Position-Sensitive and Energy-Constrained Characterization of an Opaque Scintillation Detector (#1047)

S. Katz1, G. Wendel2, J. Moffatt2, A. Wilhelm3, M. Yeh4, D. F. Cowen2, I. Jovanovic1

1 University of California, Berkeley, Department of Nuclear Engineering, Berkeley, California, United States of America
2 Pennsylvania State University, Department of Physics, University Park, Pennsylvania, United States of America
3 United States Military Academy West Point, Department of Physics & Nuclear Engineering, West Point, New York, United States of America
4 Brookhaven National Laboratory, Chemistry Division, Upton, New York, United States of America

On Behalf of the LiquidO Consortium

Abstract

LiquidO detectors stochastically confine scintillation and Cherenkov light around energy depositions by using media with a short optical scattering length. Wavelength-shifting fibers latticed throughout the volume capture the confined light, re-emit it, and transport it to photosensors, creating an optically segmented detector without physical optical barriers. Optical segmentation offers the prospect of effective particle identification and directional reconstruction by using the time of flight, energy deposition, and topology of events that deposit energy at multiple locations in the detector volume. A critical first step toward this capability is a position-sensitive calibration to evaluate detector homogeneity and single-scatter spatial and energy resolution. To achieve this, a four-liter LiquidO prototype detector was constructed and exposed to a collimated Cs-137 source in a tagged Compton scattering configuration. A sodium-iodide detector views the scattering region, providing spatially and energetically constrained event tagging. A Monte Carlo simulation of the experimental geometry models optical photon propagation, light collection, and photosensor noise. Initial measurements indicate a light collection of ~100 photoelectrons per MeV can be achieved in the detector center, and ongoing analysis compares measured and simulated detector responses to quantify the spatial and energy resolution.

AcknowledgmentThis research is partly sponsored by the Defense Threat Reduction Agency (DTRA) as part of the Interaction of Ionizing Radiation with Matter University Research Alliance (IIRM-URA) under contract number HDTRA1-20-2-0002.
Keywords: LiquidO detector, optical segmentation, Compton scattering, detector calibration
16:30 NSS-16-07

Large Scale Lu2O3:Yb Ceramics for High-Rate Calorimetry (#2903)

L. Soundara Pandian1, M. Muller1, G. Adhikari1, A. Kim1, S. Kim1, L. Zhang2, H. Newman2, P. Albert3, J. Reiss3, Y. Wang1, J. Glodo1

1 Radiation Monitoring Devices, Inc., Watertown, Massachusetts, United States of America
2 California Institute of Technology, Physics, Mathematics and Astronomy Division, Pasadena, California, United States of America
3 Pennsylvania State University, Applied Research Laboratory, State College, Pennsylvania, United States of America

Abstract

Future high‑luminosity collider experiments require scintillators that combine high density, ultrafast response, and strong radiation tolerance. Yb‑doped lutetium oxide (Lu₂O₃:Yb) is a promising candidate due to its 9.4 g/cm³ density, sub‑2 ns charge transfer luminescence, and light yield near 500 photons/MeV. Due to its very high melting point, Lu2O3 is more effectively fabricated through ceramic processing, which enables scalable production of transparent, large volume components for calorimetry and fast timing systems.

Our current effort advances two complementary ceramic routes for producing Lu2O3 at detector relevant sizes. In collaboration with PSU/ARL, Field‑Assisted Sintering Technology (FAST) approach is being developed to achieve monolithic parts with target dimensions of 2 × 2 × 15 cm³. In parallel, RMD is fabricating 2.5 cm‑scale cubes and thin plates using a sinter‑plus‑HIP process. Optical and scintillation measurements show that thin plates, including 1‑inch squares and 14 × 14 × 3 mm³ samples, reach light yields near 500 ph/MeV, while larger cubes currently exhibit reduced output due to limited transparency. All samples emit near 350 nm under X‑ray excitation and maintain decay times of approximately 2 ns.

In collaboration with Caltech we also produce Lu2O3 plates for the RaDiCAL experiment as potential replacement for LYSO, leveraging the material’s high density and ultrafast timing. The combination of fast response, radiation hardness, and scalable fabrication positions Lu2O3 ceramics as a strong candidate for next‑generation HEP calorimeters and timing detectors. Our results from the latest FAST‑processed Lu2O3 samples will also be presented at the conference.

Acknowledgment

This work was supported by the United States Department of Energy through competitively awarded contract number DE-SC0021686. This support does not constitute an express or implied endorsement on the part of the Government.

 

Keywords: Lu2O3, Ceramic Scintillators, Ultrafast decay, radiation hard, high density
16:45 NSS-16-08

Calibration of the Light Detection System of the XEMIS2 Liquid Xenon Compton Camera (#3185)

Y. Ramsi1, N. Beaupere1, J.-L. Beney1, H. Benhabiles7, T. Bossis1, P. Crespi2, S. Diglio1, D. Giovagnoli6, A. Hervo1, J. Idier3, V. Jaouen5, F. Lefevre1, O. Lemaire1, P. Le Ray1, J. Masbou1, E. Morteau1, P. Pichot1, C. Renard1, M. Staempflin2, S. Stute4, J.-S. Stutzmann1, D. Thers1

1 Subatech, IMT Atlantique, CNRS/IN2P3, Nantes Université., Nantes, France
2 Air Liquide Advanced Technologies, Sassenage, France
3 Nantes Université, École Centrale Nantes, CNRS, LS2N., Nantes, France
4 CRCI2 NA, INSERM UMR 1307, Nantes University, Nantes, France, Nantes, France
5 IMT Atlantique, Data Science Department and LaTIM, Inserm, Brest, France., Brest, France
6 IMT Atlantique, Data Science Department, Brest, France, Brest, France
7 IMT Nord Europe, Lille, France., Lille, France

Abstract

XEMIS2 is a liquid xenon Compton camera developed at the Subatech laboratory in Nantes, France, designed to demonstrate 3 gamma nuclear imaging on small animals for the first time. This technique exploits the three gamma rays simultaneously emitted by Scandium-44, whose combined detection constrains the emitter position in 3D, enabling a reduction of the injected activity by a factor of 100 compared to conventional Positron Emission Tomography while maintaining equivalent image quality. The detector simultaneously measures two complementary signals: scintillation light, detected by 64 photomultiplier tubes surrounding the liquid xenon active volume, and ionisation electrons, drifted by a 2 kV/cm electric field toward a pixelised anode. Accurate image reconstruction relies critically on the precise calibration of the light acquisition system. The full light calibration chain developed for XEMIS2 is presented, covering the determination of detection thresholds, the photomultiplier tubes gain calibration procedure, and the inter-channel time delay correction validated on both simulation and experimental data.

AcknowledgmentThis project has received financial support from the CNRS through the MITI interdisciplinary programs
References
[1] L. Gallego Manzano. Optimization of a single-phase liquid xenon Compton camera for 3 gamma medical imaging. Nuclear Experiment [nucl-ex]. Ecole des Mines de Nantes, 2016. 
[2] Y. Xing. Studies and optimization of ionization signal measurement for the 3-gamma imaging XEMIS2 liquid xenon Compton camera. Nuclear Experiment [nucl-ex]. Ecole nationale supérieure Mines-Télécom Atlantique, 2021.
[3] D. Cai. Contributions to instrumental developments for the XEMIS2 camera, on-board ionization and scintillation measurements. Nuclear Experiment [nucl-ex]. Ecole nationale supérieure Mines-Télécom Atlantique, 2024.
Keywords: Calibration, Medical Imaging, Photomultiplier Tubes, Three-gamma Imaging, Xenon