Advanced tomographic reconstruction techniques, X-ray imaging systems (CT, spectral CT, photo-counting CT)

Session chair: Reader, AndrewJ., Professor (King's College London, School of Biomedical Engineering and Imaging Sciences, London, UK); Qi, Wenyuan, Dr.
 
Shortcut: M-LT-01
Date: Wednesday, 11 November, 2026, 12:45 - 13:05
Location: FEDERICO GARCÍA LORCA
Session type: MIC Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

12:45 M-LT-01-01

SPECT Reconstruction via Diffusion Sampling from a PET Image Manifold for Theranostics (#1954)

H. Wei1, L. Livieratos1, 2, G. Webber1, A. J. Reader1

1 Kings College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
2 Kings College London, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom

Abstract

Single photon emission computed tomography (SPECT) remains the standard modality for uptake verification and patient-specific dosimetry in molecular radiotherapy (MRT), however it has limited spatial resolution and noise characteristics compared to pre-therapy positron emission tomography (PET). Existing approaches that incorporate PET priors into SPECT reconstruction are often constrained by hand-crafted feature representations and suffer from inter-modality mismatch and registration-induced artifacts. In this work, we employ a conditional generative framework to enhance SPECT reconstruction toward PET-level image quality. A denoising diffusion probabilistic model (DDPM) is trained to learn the distribution of high-quality PET images. During inference, the reverse diffusion process is conditioned on measured SPECT data and CT images, enabling anatomically consistent, high-fidelity image synthesis. The method is initially assessed using 2D Zubal phantom simulations. Performance is compared with conventional maximum likelihood expectation maximization (MLEM) and kernel based methods. Both quantitative metrics and qualitative analysis demonstrate that the diffusion-based approach achieves enhanced edge preservation and superior noise suppression. The reconstructed images show closer agreement with reference data compared to MLEM and kernel based reconstructions. By avoiding explicit PET–SPECT registration, the framework mitigates spatial misalignment and associated artifacts. These results indicate that conditional diffusion sampling provides a principled and flexible approach to improve resolution and noise limitations in SPECT, with potential to improve quantitative accuracy in MRT applications.

References
[1] H. Marquis, D. Deidda, A. Gillman et al., “Theranostic SPECT reconstruction for improved resolution: application to radionuclide therapy dosimetry,” EJNMMI Phys., vol. 8, no. 1, p. 16, Feb. 2021.
[2] F. Liu, H. Zhu, J. Yu et al., “68Ga/177Lu-labeled DOTA-TATE shows similar imaging and biodistribution in neuroendocrine tumor model,”Tumour Biol., vol. 39, no. 6, p. 1010428317705519, Jun. 2017.
[3] H.Wei, L. Livieratos, and A. J. Reader, “PET Guided Kernel EM Methods for SPECT Reconstruction in Molecular Radiotherapy,” in Proc. IEEE Nucl. Sci. Symp. Med. Imaging Conf. (NSS/MIC), Nov. 2025, pp. 1–1.
[4] G. Webber and A. J. Reader, “Diffusion models for medical image reconstruction,” BJR—Artif. Intell., vol. 1, no. 1, p. ubae013, Mar. 2024.
[5] I. R. Singh, A. Denker, R. Barbano et al., “Score-Based Generative Models for PET Image Reconstruction,” Mach. Learn. Biomed. Imaging, vol. 2, no. Generative Models, pp. 547–585, Jan. 2024.
[6] K. Thielemans, C. Tsoumpas, S. Mustafovic et al., “STIR: software for tomographic image reconstruction release 2,” Phys. Med. Biol., vol. 57, no. 4, pp. 867–883, Feb. 2012.
Keywords: Theranostics, Generative AI, Emission Tomography Reconstruction, Deep Learning, Diffusion Model
12:47 M-LT-01-02

Event-by-Event Energy-Dependent List-Mode Reconstruction for Quantitative 90Y Bremsstrahlung SPECT (#2953)

C. Yan1, H. Hu1, J. Qin1, H. Ye1, C. Yang1, F. Chen2, 3, R. Zhao2, 3, H. Li2, 3, Z. He4, Y. Liu5, H. Liu5, J. Wu1

1 Beijing Normal University, Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing, China
2 China Institute for Radiation Protection, Shanxi, China
3 Shanxi Provincial Key Laboratory for Translational Nuclear Medicine and Precision Protection, Shanxi, China
4 Beijing Tsinghua Changgung Hospital, Department of Nuclear Medicine, Beijing, China
5 Tsinghua University, Department of Engineering Physics, Beijing, China

Abstract

90Y bremsstrahlung SPECT imaging remains challenging due to its broad continuous energy spectrum. In this study, we proposed and evaluated a novel event-by-event energy-dependent list-mode reconstruction algorithm for quantitative 90Y bremsstrahlung SPECT. To enable real-time and reasonably accurate energy-dependent collimator-detector response modeling, we proposed and incorporated a True Half-Width method into the list-mode reconstruction framework. Monte Carlo simulations were performed using three energy windows: 90-160 keV, 105-285 keV, and 90-400 keV. Quantitative evaluation was performed using contrast recovery coefficient and background variability. Compared with projection-based reconstruction, list-mode reconstruction achieved the best quantitative performance using the 90-400 keV energy window, owing to accurate event-level energy-dependent system matrix modeling over the broad continuous energy spectrum. These results demonstrate that event-by-event energy-dependent list-mode reconstruction is essential for improving the quantitative accuracy of 90Y bremsstrahlung SPECT.

AcknowledgmentThis study was supported by National Natural Science Foundation of China (No. 12305379, No.12205166), Beijing Natural Science Foundation (Z220010), CIRP Open Fund of Radiation Protection Laboratories (TNMPP-2024-No.1).
References
[1] Se Y, Minh P, Thanh Q, et al. Algorithms and Analyses for Joint Spectral Image Reconstruction in Y-90 Bremsstrahlung SPECT. IEEE Trans. Med. Imaging, 2020,39:1369-1379.
[2] Nathan C, Muthana S, De Nadine A, et al. AAPM Medical Physics Practice Guideline 14.a: Yttrium-90 microsphere radioembolization. Med. Phys, 2023,25:1-28.
[3] Se Y, Jeffrey A, Yuni K. Correction for Collimator-Detector Response in SPECT Using Point Spread Function Template. IEEE Trans. Med. Imaging, 2013,32:295-305.
Keywords: 90Y bremsstrahlung SPECT, collimator-detector response, list-mode reconstruction, energy window selection
12:49 M-LT-01-03

Introducing “T-Index”—A Metric for Quantifying Data Range and Sampling Sufficiency (#2039)

K. Taguchi1, J. Xu1

1 Johns Hopkins University, Baltimore, Maryland, United States of America

Abstract

Many image reconstruction methods for x-ray computed tomography (CT) use optimization approaches with cost functions that consist of a data fidelity term and a prior term. Extensive efforts have been devoted to construct better priors, some using machine learning, for high resolution, low dose, and spectral imaging. There seems to be a belief that a good prior can overcome any problems in data acquisition, downplaying the data fidelity term. It would be desirable if we could quantify the sufficiency of the problem setting (or adequacy of the data acquisition) toward a set of desired imaging properties. We propose “Truth index” or “T-index” to quantify data range and data sampling issues in this work. When fully developed, the T-index will show, independent of specific image reconstruction methods used, how much the solution can be trusted or has a risk of hallucination.

AcknowledgmentThe work has been supported by NIH grants R01 NS126256, U01 EB037558, R01 EB036984, R21 EB034337, R21 EB033426, R21 EB037806. 
References
[1] Lastname, GN, Lastname, GN YYYY, ‘Article’, Journal, Edition, Page, Place of publication: publishers
Jørgensen, J. S., Sidky, E. Y., and Pan, X, 2012, "Quantifying admissible undersampling for sparsity-exploiting iterative image reconstruction in X-ray CT," IEEE Trans Med Imaging, vol. 32, no. 2, pp. 460-73, Feb 2013, doi: 10.1109/tmi.2012.2230185.
 
Keywords: Computed tomography, data sufficiency, sampling sufficiency
12:51 M-LT-01-04

Time-of-Flight X-ray Imaging with Scatter Rejection and Subtraction (#3042)

A. Lorenzon1, Z. Liu1, X. Jiang1, W. Zbijewski1, J.W. Stayman1

1 Johns Hopkins University, Biomedical Engineering, Baltimore, Maryland, United States of America

Abstract

X-ray time of flight information can be used in computed tomography to characterize photon interactions and discriminate scattered from unscattered events. Specifically, photons undergoing Compton and Rayleigh scattering are subject to trajectory deviations that increase their path length relative to primary photons. Therefore, with adequate temporal resolution, scattered photons are detected with larger time delay with respect to primary photons, providing a physically grounded mechanism to reject scatter. Recent technological developments in ultra-fast X-ray sources (e.g: 50ps) and high-temporal-resolution photon-counting detectors may allow for this imaging modality.

In this work, Monte Carlo (MC) simulations of a water cylinder were performed assuming Gaussian source pulse shape and detector timing jitter, with combined full-width-half-maximum as low as 50ps. A threshold-based scatter rejection method was applied, sweeping multiple thresholds to find the optimal balance between scatter rejection efficiency (η) and primary retention (ε). Filtered-backprojection reconstructions were performed and evaluated in terms of root mean square error and bias. Rejection performances were compared with an ideal, MC-based scatter subtraction technique, that leverages template fitting to estimate the average scatter contribution from time-delay histograms. A combined rejection-subtraction approach was also evaluated.

For rejection only, the optimal reconstruction accuracy is obtained with a threshold T’=30 ps, corresponding to η=59% and ε=80%. Residual scatter leads to bias in the reconstructed attenuation, preventing the method from achieving the same reconstruction accuracy as the ideal subtraction. However, rejection yields lower noise levels compared to subtraction. Combining rejection and subtraction may provide a better compromise between bias and noise.
AcknowledgmentThis work is supported, in part, by grant #0030253 from the Korea Institute for Advancement of Technology.
Keywords: X-ray scattering, Computed Tomography, Time of flight
12:53 M-LT-01-05

Robustness to Scatter in Dual Energy Bone Suppression for Chest Radiography (#3063)

G. Shi1, J. Schaefer3, S. Vogt3, A. Heshmat3, L. Ritschl3, S. Kappler3, C. T. Lin2, D. Oncel2, S. Ocal2, W. Zbijewski1

1 Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States of America
2 Johns Hopkins University, Russel H. Morgan Dept. of Radiology and Radiological Science, Baltimore, Maryland, United States of America
3 Siemens Healthineers, Forchheim, Bavaria, Germany

Abstract

We quantify the impact of scatter on the performance of bone suppression in virtual non‑calcium chest radiographs (VNCa‑CXR) generated with (i) a multi‑layer flat‑panel detector (ML‑FPD, three 200-um thick CsI layers) and (ii) with a kV‑switching protocol (60/140 kVp). We show that in the setting of log-subtraction, the decomposition weight (DW) can be adjusted for scatter-to-primary ratio (SPR) such that the scatter-induced bias in VNCa is locally corrected (scatter-compensating weight, DW-scat). However, DW-scat is spatially varying. If a constant DW is used in log-subtraction, the magnitude of bone residual in VNCa radiographs will depend on the degree of spatial inhomogeneity in DW-scat. We investigate this effect is simulation studies in anthropomorphic chest phantoms (20 – 24 cm thickness) with and without an anti-scatter grid (ASG).  Without a scatter‑compensating DW, scatter‑induced bone residual increased by >100% is most configurations except for ML-FPD with a grid. Applying DW-scat averaged over central lung region reduced the residual by up to 50% for ML-FPD without an ASG and by ~40% for kV-switching with an ASG. Overall, our results reveal that DE VNCa imaging is relatively robust to scatter in scenarios with a grid, where kV-switching appears to benefit from spatially-averaged scatter-compensating DW more than ML-FPD, likely due to differences in scatter content of the two energy channels.  Without a grid, both configurations may require a spatially-dependent scatter compensation for optimal bone suppression.  

AcknowledgmentThis work was supported in part by Siemens Healthineers. The product/feature and/or service offerings mentioned herein are not commercially available in all countries and/or for all modalities. Their future availability cannot be guaranteed.
Keywords: dual energy radiography, bone suppression, chest radiography, scatter
12:55 M-LT-01-06

Unrolled relaxed algorithm for 3D SPECT reconstruction (#2388)

C. Constanza1, D. Sarrut1, A. Etxebeste1, 2

1 CREATIS, CNRS UMR 5220; INSERM U 1044, Université de Lyon; INSA-Lyon; Université Lyon 1, Villeurbanne, France
2 Centre de lutte contre le cancer Léon-Bérard, Lyon, France

Abstract

In this work, we propose an unrolled Block Sequential Regularized Expectation Maximization (BSREM) reconstruction framework in which the gradient of the regularization term is learned using a convolutional neural network. Building on our previous work, we adopt Jacobian-Free Unrolling (JFU) to enable memory-efficient training on 3D synthetic data. This training strategy backpropagates only through the final iteration of the unrolled optimization, significantly reducing memory consumption while improving training stability. We investigate the influence of relaxation strategies within the unrolled BSREM scheme and analyze their impact on convergence behavior, stability, and reconstruction quality. Experiments conducted on realistic simulated SPECT datasets and clinical  177Lu-DOTATATE patient data show that JFU-based unrolling consistently outperforms classical unrolled training for an equivalent number of parameters and memory usage. Unlike classical unrolling, which requires strong relaxation to ensure stable training, JFU achieves optimal performance with weak or no relaxation. Excessive relaxation is shown to be suboptimal, leading to reduced quantitative accuracy. Quantitative evaluations demonstrate improvements in both global image quality and organ-level activity accuracy compared to OSEM and conventional BSREM with a Relative Difference Penalty prior. As observed in our previous study using Green’s one-step-late algorithm, the proposed approach may introduce over-separation artifacts between regions of low and high activity. This behavior appears intrinsic to learning the regularization gradient rather than to the unrolling strategy itself. Overall, this work highlights the advantages of Jacobian-Free Unrolling for scalable and stable learning-based SPECT reconstruction and provides insights into the role of relaxation in unrolled optimization schemes.

AcknowledgmentAll authors declare that they have no known conflicts of interest.
References
[1] H. M. Hudson and R. S. Larkin, “Accelerated image reconstruction using ordered subsets of projection data,” IEEE Transactions on Medical Imaging, 1994.
[2] S. Ahn, S. G. Ross, E. Asma, J. Miao, X. Jin, L. Cheng, S. D. Wollenweber, and R. M. Manjeshwar,, “Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET,” Physics in Medicine & Biology, 2015.
[3] P. J. Green, “Bayesian reconstructions from emission tomography data using a modified EM algorithm,” IEEE Transactions on Medical Imaging, 1990.
[4] S. Ahn and J. A. Fessler, “Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms,” IEEE Transactions on Medical Imaging, 2003.
[5] V. Monga, Y. Li, and Y. C. Eldar, “Algorithm unrolling: Interpretable, efficient deep learning for signal and image processing,” IEEE Signal Processing Magazine, 2021.
[6] S. W. Fung, H. Heaton, Q. Li, D. McKenzie, S. Osher, and W. Yin, “Jfb: Jacobian-free backpropagation for implicit networks,” in AAAI Conference Proceedings, 2022.
[7] L. Davy, L. M. Briceno-Arias, and N. Pustelnik, “Restarted contractive operators to learn at equilibrium,” arXiv preprint arXiv:2506.13239, 2025.
[8] T. Kaprélian, A. Etxebeste, and D. Sarrut, “Partial volume correction of SPECT images with deep learning trained on synthetic data,” IEEE Transactions on Radiation and Plasma Medical Sciences, 2025
[9] J. Leube, J. Gustafsson, M. Lassmann, M. Salas-Ramirez, and J. Tran-Gia, “A deep-learning–based partial-volume correction method for quantitative 177Lu SPECT/CT imaging,” Journal of Nuclear Medicine, 2024.
Keywords: Unrolled network, Image reconstruction, Deep Learning, SPECT/CT
12:57 M-LT-01-07

Three-Photon Bayesian Imaging of Ortho-Positronium (#2897)

W. Krzemien1, L. Raczyński2, A. Coussat3

1 National Centre for Nuclear Research, Department of High Energy Physics, Otwock Swierk, Poland
2 National Centre for Nuclear Research, Department of Complex Systems, Otwock Swierk, Poland
3 INSA-Lyon, niversité Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, F-69373, Lyon, France

On behalf of IMPET project

Abstract

Positron emission tomography provides functional images from two-photon coincidences. In human tissue, approximately 40% of annihilations are preceded by positronium formation, of which the ortho-positronium component partially decays into three photons [1]. This three-photon channel carries additional information about the local micro-environment [1], including the three-to-two-photon yield ratio as a potential diagnostic marker [3,2], and its exploitation does not require a prompt photon, making it compatible with standard radionuclides such as FDG. We propose the Three-Photon Bayesian Imaging of Ortho-Positronium algorithm, a novel event-by-event reconstruction method formulated as a Bayesian maximum a posteriori inference problem, which unifies time-based trilateration [4], energy-based reconstruction [3], and a physics-informed prior derived from the quantum electrodynamics description of ortho-positronium decay [5-6] within a single probabilistic framework. Monte Carlo simulations modelled after the Siemens Biograph Quadra scanner [7] demonstrate an improvement of a factor of two over time-based trilateration and by an order of magnitude over energy-based reconstruction. The proposed approach is compatible with existing scanners capable of registering three-photon coincidences, broadening its applicability beyond positronium lifetime imaging to standard clinical radionuclides.

AcknowledgmentThe work was supported by the Foundation for Polish Science through the FIRST TEAM FENG.02.02-IP.05-0152/23 programme co-financed by the European Union under the European Funds for Smart Economy 2021-2027 (FENG). by the “PHC POLONIUM” program (project number: 55194PB), funded by the French Ministry for Europe and Foreign Affairs, the French Ministry for Higher Education, Research, and Space, and the Polish NAWA (BPN/BFR/2025/1/00036/ and BPN/BAT/2025/1/00009), and co-supported by the Austrian Ministry for Women, Science and Research (project WTZ PL 11/2026).
References
[1] Hourlier, A, Boisson, F & Brasse, D 2024, 'Experimental uses of positronium and potential for biological applications', IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 8, no. 6, pp. 581–594
[2] Fujimoto, M et al. 2025, 'Advancing PET through direct imaging of three-photon decay using pure positron emitters', unpublished.
[3] Kacperski, K, Spyrou, NM & Smith, FA 2004, 'Three-gamma annihilation imaging in positron emission tomography', IEEE Transactions on Medical Imaging, vol. 23, no. 4, pp. 525–529.
[4] Gajos, A et al. 2016, 'Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector', Nuclear Instruments and Methods in Physics Research Section A, vol. 819, pp. 54–59.
[5] Ore, A & Powell, JL 1949, 'Three-photon annihilation of an electron–positron pair', Physical Review, vol. 75, no. 11, pp. 1696–1699.
[6] Berestetskii, VB, Lifshitz, EM & Pitaevskii, LP 2008, Quantum Electrodynamics, 2nd edn, Butterworth-Heinemann, Oxford.
[7] Prenosil, GA et al. 2022, 'Performance characteristics of the Biograph Vision Quadra PET/CT system with a long axial field of view using the NEMA NU 2-2018 standard', Journal of Nuclear Medicine, vol. 63, no. 3, pp. 476–484.
Keywords: Bayesian inference, positron emission tomography, ortho-positrionium, three-gamma annihaltion, trilateration
12:59 M-LT-01-08

Lutetium-176-Aided Joint Activity and Attenuation Reconstruction in TOF-PET Using Trust-Region Cubic Surrogate Optimization (#2772)

X. Zhao1, Z. Zhao1, Z. Wang1, Z. Xie1

1 Peking University, Beijing, China

Abstract

Joint Maximum Likelihood Activity and Attenuation (MLAA) provides a promising CT-less attenuation correction framework but suffers from global scaling ambiguity. Intrinsic Lu-176 background radiation provides patient-specific transmission information to reduce this issue, while introducing a highly nonlinear and ill-conditioned joint likelihood. We propose the Separable Cubic Surrogate with Trust Region (SCS-TR) algorithm, utilizing an analytical Lipschitz constant and a vectorized solver to ensure strictly monotonic convergence and avoid local optima. The reconstruction is initialized with Maximum Likelihood Transmission Reconstruction (MLTR) results. GATE simulations studies demonstrate that SCS-TR effectively recovers clear bone structures and smooth uniform regions without explicit regularization. The proposed method recovered clear bony structures and uniform soft-tissue regions without explicit regularization, and maintained structural fidelity under 20% count statistics.

AcknowledgmentThis work was supported by National Natural Science Foundation of China (62394311) and National Biomedical Imaging Facility Grant.
References
[1] Omidvari N, Cheng L, Leung E K, et al. Lutetium background radiation in total-body PET—A simulation study on opportunities and challenges in PET attenuation correction[J]. Frontiers in Nuclear Medicine, 2022, 2: 963067.
[2] Cartis C, Gould N I M, Toint P L. Adaptive cubic regularisation methods for unconstrained optimization. Part I: motivation, convergence and numerical results[J]. Mathematical Programming, 2011, 127(2): 245-295.
[3] Li T, He L, Liu Z, et al. CT-Less Attenuation Correction for PET using Backward Inter-Crystal Scattered Events[C]//2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conference (RTSD). IEEE, 2024: 1-1
[4] Nesterov Y, Polyak B T. Cubic regularization of Newton method and its global performance[J]. Mathematical programming, 2006, 108(1): 177-205.
Keywords: Joint estimation, Lutetium intrinsic radiation, attenuation correction
13:01 M-LT-01-09

List-Mode Derived Synthetic Kernel-Based Image Reconstruction for Dynamic Total Body PET (#2844)

M. Dassanayake1, L. Vass1, P. Marsden1, J. A. Schnabel1, 2, A. J. Reader1

1 King's College London, Department of Imaging Physics and Engineering at the School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
2 Technical University Munich, School of Computation, Information and Technology, Munich, Germany

Abstract

Total-body positron emission tomography (TB-PET) provides significantly improved sensitivity, enabling ultra-short time framing for dynamic imaging. However, the resulting low count statistics lead to increased noise and unstable time activity curves (TACs), limiting quantitative accuracy. We investigate a kernel-based reconstruction approach within a list-mode (LM)-derived synthetic framework, where a vendor reconstruction is forward projected through an event-specific LM system matrix to generate synthetic data, implicitly includes attenuation, normalisation, scatter, and randoms effects while enabling flexible algorithm design.
Spatial, temporal, and spatio-temporal kernels are evaluated for short-frame FDG data acquired on a Biograph Vision Quadra system, with features constructed from multiple dynamic intervals. Reconstructions are compared with a 10x higher count vendor reference images using spatial and temporal PRMSE. Spatially, the spatio-temporal kernel achieves the lowest error. In addition, we demonstrated that kernel methods benefit from larger neighbourhoods resulting in improved visual quality compared to synthetic PET. This was computationally feasible on consumer hardware by using region-of-interest specific reconstructions.
These results demonstrate that LM-derived synthetic kernel reconstruction provides a flexible framework for incorporating spatial and temporal priors in TB-PET. While performance is currently limited by kernel parameter selection, the observed improvements in spatial and temporal behaviour indicate strong potential for optimisation through tuning the kernel strength and feature vector design.

AcknowledgmentMD would like to acknowledge funding from the EPSRC Centre for Doctoral Training in Smart Medical Imaging [EP/S022104/1] and via a Siemens Healthineers Studentship.
References
[1] Wang, G, Qi, J, 2015, 'PET Image Reconstruction Using Kernel Method',  IEEE Transactions on Medical Imaging, vol. 34, no. 1, pp. 61–71, 2015
 
[2] Hutchcroft, W et al., 2016, 'Anatomically-aided PET reconstruction using the kernel method', Physics in Medicine and Biology, vol. 61, no. 18, pp. 6668–6683,
[3] Bland, J, et al., 2018, 'MR-Guided Kernel EM Reconstruction for Reduced Dose PET Imaging', IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 2, no. 3, pp. 235–243, 2018.
[4] Vass, L and Reader, AJ, 2023, 'Synthesized Image Reconstruction for Post-Reconstruction Resolution Recovery', IEEE Transactions on Radiation and Plasma Medical Sciences, vol. 7, no. 5, pp. 473–482, 2023
[5] Lastname, GN, Lastname, GN YYYY, ‘Article’, Journal, Edition, Page, Place of publication: publishers
Schramm, G and Thielemans, K, 2024, 'PARALLELPROJ—an open-source framework for fast calculation of projections in tomography', Frontiers in Nuclear Medicine
 
Keywords: PET image reconstruction, Kernel method, Total body PET, Region-of-Interest reconstruction
13:03 M-LT-01-10

Unsupervised micro-CT reconstruction from limited-angle and truncated data in cone-beam geometry (#1238)

K. Izumitani1, 2, T. Shibuya2, 3, H. Kato2, 3, H. Haneishi4, T. Okamoto4

1 Chiba University, Graduate School of Science and Engineering, Chiba, Japan
2 National Institute of Advanced Industrial Science and Technology (AIST), Research Institute for Measurement and Analytical Instrumentation, National Metrology Institute of Japan, Tsukuba, Japan
3 National Institute of Advanced Industrial Science and Technology (AIST), Non-Destructive Imaging Research Team, Integrated Research Center for Resilient Infrastructure, Tsukuba, Japan
4 Chiba university, Center for Frontier Medical Engineering, Chiba, Japan

Abstract

Micro X-ray computed tomography (micro-CT) enables non-destructive visualization of fine internal structures. Resolving finer details requires higher geometric magnification, typically achieved by reducing the source-to-rotation-center distance (SRD). However, short-SRD acquisition can suffer from a limited angular range due to physical interference with the X-ray source and from projection truncation when the object extends beyond the field-of-view (FOV), causing streak artifacts and structural distortions. Supervised learning-based reconstruction methods have been investigated to mitigate such artifacts but applying them to non-destructive high-magnification micro-CT is difficult because fully sampled, non-truncated reference data cannot be readily acquired without destructive sample preparation. Moreover, many existing methods are designed for 2D fan-beam geometry rather than 3D cone-beam geometry commonly used in micro-CT. We propose an unsupervised reconstruction method that simultaneously reduces limited-angle and projection-truncation artifacts by incorporating long-SRD measurements. Long-SRD acquisition provides full-view, non-truncated projections, albeit at lower spatial resolution, complementing the high-resolution but incomplete short-SRD acquisition. By jointly using these complementary measurements, the proposed method preserves fine structural details while recovering the global object structure without requiring ground-truth images. Numerical experiments demonstrated that the proposed method reduced streak artifacts and recovered structural information outside the short-SRD FOV. To the best of our knowledge, this is the first unsupervised 3D cone-beam reconstruction method to simultaneously address both artifacts in high-magnification micro-CT.

Acknowledgment

This study was supported by JSPS KAKENHI, Grant Number JP25K21580; JST, ACT-X, Grant Number JPMJAX23K5; and JSPS Program for Forming Japan’s Peak Research Universities (J-PEAKS), Grant Number JPJS00420230002.

References
[1] Y. Huang et al., “Data consistent CT reconstruction from insufficient data with learned prior images”, arXiv preprint, 2005.10034, 2020.
[2] K. Izumitani, H. Haneishi, and T. Okamoto, “Weakly supervised limited-angle CT reconstruction using multiple projection geometries”, 2025 IEEE NSS MIC RTSD, Yokohama, Japan.
[3] H. Kim and K. Champley, “Differentiable forward projector for x-ray computed tomography,” arXiv preprint, 2307.05801, 2023.
Keywords: Artifact reduction, computed tomography (CT), limited-angle CT, truncated CT, micro-computed tomography (micro-CT)


Our Exhibitors: