IEEE 2026 NSS MIC RTSD

Please note! All times in the online program are given in Madrid - Europe (CET) times!

Madrid - Europe ()
Oct 23, 2026, 8:56:29 PM
Your time ()
n/a
Madrid - Europe ()
Oct 23, 2026, 8:56:29 PM
Our Sponsors:

To search for a specific ID please enter the hash sign followed by the ID number (e.g. #123).

RTSD Opening

Session chair: Fiederle, Michael, Professor (Albert-Ludwigs-Universität Freiburg, Freiburger Materialforschungszentrum (FMF), Freiburg, Germany); Arino-Estrada, Gerard, (IFAE-BIST, Campus UAB, Bellaterra, Barcelona, Spain)
 
Shortcut: RTSD-01
Date: Monday, 9 November, 2026, 15:00 - 17:00
Location: ANDALUCÍA II & III
Session type: RTSD Session

Contents

Click on an contribution to preview the abstract content.

The underlined authors are the presenters. The authors in bold are the main authors.

15:00 RTSD-01-01

Exploring 4x4x3 cm3 3D-CdZnTe Semiconductor Gamma-Ray Detectors (#1366)

Z. He1, Y. Zhu1

1 University of Michigan, Nuclear Engineering and Radiological Sciences, Ann Arbor, Michigan, United States of America

Abstract

Three-dimensional position-sensitive single-crystal CdZnTe detectors (3D-CZT), with energy resolution of ~0.3% FWHM for single-pixel events and ~0.5% FWHM for all events at 662 keV, had been demonstrated previously on detectors with dimensions up to 2x2x1.5 cm3 (total 6 cm3). Larger volume single-crystal CdZnTe semiconductor gamma-ray detectors are needed to achieve higher intrinsic detection efficiency at higher gamma-ray energies. 4x4x3 cm3 (total 48 cm3) 3D-CZT detectors manufactured by Redlen Technologies have been explored for the first time. Energy spectra of Cs-137 were obtained on all three 4x4x3 cm3 CZT detectors. An energy resolution of 1.05% FWHM at 662 keV was obtained for single-pixel events on one 4x4x3 cm3 CZT detector #12R2. The feasibility of achieving close to 1.0% FWHM energy resolution on CdZnTe gamma-ray detectors with single-crystal detection volume of 48 cm3 has been demonstrated.

Acknowledgment

This material is based upon work supported by the Defense Threat Reduction Agency (DTRA) under Contract No. HDTRA124C0002. Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the Defense Threat Reduction Agency.

References
[1] https://h3dgamma.com/
[2] A.E. Bolotnikov et al. "Performance of 8x8x32 and 10x10x32 mm3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras", Nucl. Instr. and Meth. A 969 (2020) 164005.
 
[3] Y.F. Zhu, Z. He, “Evaluation of Pixelated 2×2×3 cm3 CdZnTe Detectors”, 2025 IEEE Nucl. Sci. Sym. Conf. at Yokohama, Japan.
Keywords: CdZnTe, three-dimensional position-sensitive, semiconductor, gamma-ray detectors
15:15 RTSD-01-02

Visualizing the Hidden Physics of CdTe Detectors: Direct Spatiotemporal Imaging of Charge Clouds (#1397)

A. Cola1, A. Valletta2, I. Farella3, V. Dědič4, L. Dominici5

1 CNR, IMM, Lecce, Italy
2 CNR, IMM, Roma, Italy
3 CNR, IMM, Lecce, Italy
4 Charles University, Institute of Physics, Prague, Czech Republic
5 CNR, Nanotec, Lecce, Italy

Abstract

Carrier Dynamics by Pockels Imaging (CDPI) is a novel all-optical, quantitative, and non-invasive method for direct spatiotemporal visualization of charge carrier clouds in CdTe radiation detectors. CDPI achieves micrometer-scale spatial resolution and nanosecond temporal resolution, with sensitivity to electric field differences down to ~2 V/cm – enabling tracking of carrier densities just above the intrinsic level. We directly observe electron cloud formation and evolution, including Gaussian shape preservation, diffusion-driven broadening, and field-dependent reshaping. Under high optical excitation, we resolve space-charge perturbed regimes with cloud expansion due to Coulomb repulsion (width up to 400 µm) and pronounced asymmetric tails due to detrapping processes, possibly correlated with a defective layer near the cathode surface. Crucially, CDPI correlates internal cloud dynamics with external circuit currents, linking microscopic physics to macroscopic detector performance. Although demonstrated in one dimension, CDPI is intrinsically two-dimensional and readily extendable to investigate charge sharing in segmented electrodes or pixel arrays. The technique also supports studies of ultra-high photogenerated charge densities relevant to synchrotron and free-electron laser applications and enables direct visualization of carrier injection from the contacts. CDPI offers a powerful new diagnostic tool for understanding and improving CdTe and other compound semiconductor radiation detectors.

AcknowledgmentThis research was partially funded by the PNRR MUR project PE0000023- NQSTI, financed by the European Union – Next Generation EU.
Keywords: CdTe, charge carrier dynamics, carrier cloud, Pockels effect, radiation detectors
15:30 RTSD-01-03

Compton Imaging Capability of 1-cm-Thick Pixelated TlBr Detectors (#1525)

K. Hitomi1, Y. Kitayama2, M. Nogami1, J. Lee3, K. Watanabe4

1 Tohoku University, Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Sendai, Japan
2 Fukushima Institute for Research, Education and Innovation, Fukushima, Japan
3 Korea Institute of Nuclear Safety, Division of Radiation Protection for NORM & Cosmic Radiation, Daejeon, Republic of Korea
4 Kyushu University, Department of Applied Quantum Physics and Nuclear Engineering, Graduate School of Engineering, Fukuoka, Japan

Abstract

Thallium bromide (TlBr) is a promising compound semiconductor for the fabrication of gamma-ray detectors because of its high atomic numbers (Tl: 81, Br: 35), high density (7.56 g/cm3), and wide bandgap energy (2.68 eV). The Compton imaging capability of 1-cm-thick pixelated TlBr detectors was characterized in this study. Pixelated TlBr detectors were fabricated from a crystal grown by the traveling molten zone method using zone-purified material. The crystal size for the detector was 12 mm x 12 mm x 10 mm. The electrodes were formed on the two 12 mm x 12 mm surfaces by vacuum deposition of Tl, followed by Ni and Au. The anode consisted of nine pixel electrodes (2 mm x 2 mm each) surrounded by guard electrodes. The cathode on the opposite side was a planar electrode. For single-pixel events, the TlBr detector exhibited energy resolutions of approximately 2% full width at half maximum or better at 662 keV for all nine pixels with depth correction and event selection based on electron drift time. Compton images of a 137Cs gamma-ray source were obtained using non-adjacent two-pixel events via the list-mode maximum likelihood expectation maximization (LM-MLEM) algorithm. Clear images of the source were reconstructed at positions consistent with the actual source locations. These results demonstrate that the TlBr detector fabricated in this study possesses high energy resolution and Compton imaging capability.

Keywords: Compton imaging, pixelated detector, room temperature semiconductor detector, thallium bromide (TlBr)
15:45 RTSD-01-04

Effect of the Anode Irradiation by X-ray on the Polarization of a CdTe Imaging Sensor (#1944)

P. Praus1, E. Belas1, M. Betusiak1, R. Grill1, S. Kacenga1, Z. Melnikova2, J. Jakubek2

1 Charles University, Faculty of Mathematics and Physics, Institute of Physics, Prague, Czech Republic
2 ADVACAM s.r.o., Prague, Czech Republic

Abstract

This work presents a study of the influence of X-ray irradiation on the electric field profile in biased CdTe sensors with blocking contacts. The investigation focuses on the modification and potential stabilization of the internal electric field through controlled irradiation of the blocking anode under varying conditions. To emulate realistic detector operation, a silicon wafer was positioned in front of the anode to represent a readout chip, while the cathode was probed by laser-induced transient current technique to determine the electric field. A synchronized pulsed bias scheme enabled time-resolved monitoring of polarization dynamics. Transient current waveforms were recorded in a shielded setup with controlled X-ray exposure, and their temporal evolution was analyzed to assess changes in the electric field profile. The results show that, under dark conditions, the sensor exhibits pronounced space charge formation due to blocking anode. In contrast, appropriately tuned X-ray irradiation of the anode leads to a significant stabilization of the field within the sensor bulk. Under these conditions, the electric field remains nearly uniform over time. The observed behavior reflects the interplay between space-charge formation and X-ray–induced carrier generation, which can partially compensate accumulated charge, although the process remains sensitive to irradiation conditions and contact configuration. Furthermore, low-energy X-ray irradiation transmitted through a silicon layer produces effects comparable to optical excitation at the anode, indicating a similar mechanism of near-contact carrier generation. The presented results provide insight into the control of polarization effects and contribute to improving the operational stability of CdTe-based radiation detectors.

AcknowledgmentThis project is co-financed from the state budget by the Technology Agency of the Czech Republic under the project TQ28000004 Semiconductors4All.
Keywords: CdTe, Pixelated Detector, L–TCT, Space Charge, X-ray
16:00 RTSD-01-05

Identification and control of interfacial limits enabling high-performance photon-counting perovskite radiation detectors (#2057)

G. Tumen-Ulzii1, S. D. Stranks1, 2

1 University of Cambridge, Department of Chemical Engineering and Biotechnology, Cambridge, United Kingdom
2 University of Cambridge, Department of Physics, Cambridge, United Kingdom

Abstract

Lead halide perovskite single crystals are promising for photon-counting radiation detection due to their high atomic number and favourable charge-transport properties. However, most perovskite detectors operate in hole-transport configurations, while currently existing readout electronics are optimised for electron collection. Bridging this mismatch requires a clear understanding of carrier-polarity-dependent transport and the underlying device physics governing perovskite detectors. We conducted polarity-resolved α-particle (241Am, 5.48 MeV) measurements on FAPbBr3 planar detectors (Au/FAPbBr3/Bi). Polarity-resolved α-particle measurements reveal strongly asymmetric degradation, with irreversible degradation localised beneath the Bi contact, whereas the Au interface develops a defect-rich recombination region that can be mitigated by ultrathin Ti or Cr interlayers, enabling stable bipolar transport operation. Detectors remain stable after ~100 h of continuous biasing at 5,000 V cm−1 and ~3 months of shelf-life storage. The combination of high-quality crystals and interfacial protection layers enables the detectors to achieve 1.3% energy resolution for 662 keV (137Cs γ-ray source) and 6.1% for 5.48 MeV α-particles in an electron-transport configuration. This work establishes interfacial degradation as the dominant performance-limiting factor in perovskite radiation detectors and identifies interfacial engineering as the key pathway toward stable and high-resolution electron-transport spectroscopy.

Acknowledgment

G.T.-U. acknowledges funding from a Marie Skłodowska-Curie Postdoctoral Fellowship via UKRI Horizon Europe Guarantee, grant no. EP/Y016912/1. G.T.-U. acknowledges the Leverhulme Trust and Isaac Newton Trust (Leverhulme Early Career Fellowship). G.T.-U., and S.D.S. acknowledge the Engineering and Physical Sciences Research Council (EPSRC, EP/W004445/1) and the Medical Research Council (APP47651) for funding.

Keywords: perovskite, photon-counting, radiation detection
16:15 RTSD-01-06

High-Z Sensor Characterisation and Readout Development for X-ray Detectors at PSI (#2720)

J. Mulvey1, D. Greiffenberg1, B. Schmitt1, M. Anastasi1

1 Paul Scherrer Institute, Center For Photon Science, Villigen, Aargau, Switzerland

On behalf of the detector group whose members include: J. Mulvey, M. Anastasi, A. Bergamaschi, M. Brueckner, M. Carulla, R. Dinapoli, S. Ebner, S. Emiliani, K. Ferjaoui, E. Fr¨ojdh, V. Gautam, D. Greiffenberg, S. Hasanaj, V. Hinger, V. Kedych, T. King, S. Li, C. Lopez-Cuenca, L. Lunin, A. Mazzoleni, D. Mezza, S. Moses, K. Moustakas, A. Mozzanica, M. Mueller, C. Ruder, B. Schmitt, S. Silletta, D. Thattil, X. Xie and J. Zhang

Abstract

The newly upgraded Swiss Light Source (SLS) 2.0, a fourth-generation synchrotron, has begun operation. Photons with energies up to 80 keV will be available at increased flux compared to the third-generation source it replaces. In particular, the brilliance is expected to increase by two orders of magnitude. In this energy range, silicon is no longer an efficient detection material. High-Z semiconductors are therefore required, with GaAs:Cr, CdTe, and CdZnTe being promising candidates. Single sensors (2 × 2) cm2 made up of 256 × 256 pixels with a 75 μm pitch have been bump-bonded to the JUNGFRAU readout ASIC. Developed at PSI, JUNGFRAU is a charge-integrating readout chip with three gain levels and dynamic gain switching. In this talk, we will discuss the ongoing characterisation of high-Z sensors using JUNGFRAU, with a focus on charge transport properties of CdZnTe produced by Redlen Technologies. Furthermore, recent efforts to improve the linear dynamic range of JUNGFRAU in electron collection mode will be discussed. We will also look towards the future with a discussion of full JUNGFRAU modules using GaAs from Dectris or recently acquired (4 × 4) cm2 CdZnTe sensors from Redlen. Additionally, the new MATTERHORN photon-counting ASIC has been designed for both silicon and high-Z sensors, with assemblies using GaAs undergoing characterisation.

References
[1] D. Greiffenberg et al., “Characterization of GaAs:Cr sensors using the charge-integrating JUNGFRAU readout chip,” Journal of Instrumentation, vol. 14, no. 05, pp. 05020, May, 2019, DOI 10.1088/1748-0221/14/05/P05020
[2] L. A. Franklin et al., “Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications,” IOP Publishing, vol. 21, no. 03, pp. 03014, March, 2026, DOI 10.1088/1748-0221/21/03/P03014
[3] D. Greiffenberg et al., “Signal stability of high-Z sensors at synchrotron light sources,” Journal of Instrumentation, vol. 20, no. 01, pp. 01031, January, 2025, DOI 10.1088/1748-0221/14/05/P05020
[4] J. Mulvey et al., (2025, July). CdZnTe (CZT) as a Material for Detecting Hard X-rays at Synchrotrons and FELs . presented at IWORID. Oral Presentation. Available: https://indi.to/5YCBb. Accessed on: May 11, 2026
[5] A. Mozzanica et al., “Prototype characterization of the JUNGFRAU pixel detector for SwissFEL,” Journal of Instrumentation, vol. 9, May, 2014, DOI 10.1088/1748-0221/9/05/C05010.
[6] A. Mozzanica et al., “The JUNGFRAU Detector for Applications at Synchrotron Light Sources and XFELs,” ynchrotron Radiation News, vol. 31, no. 06, pp. 16-20, 2018, DOI 10.1080/08940886.2018.1528429
[7] V. Kedych et al., (2025, July). Characterization of the JUNGFRAU 1.2 readout ASIC. presented at IWORID. Oral Presentation. Available: https://indi.to/KQWc4. Accessed on: May 11, 2026
[8] D. Mezza et al., ”The new Matterhorn detector for 4th generation synchrotrons,” 2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD), Vancouver, BC, Canada, 2023, pp. 1-1, doi: 10.1109/NSSMICRTSD49126.2023.10338514.
Keywords: High-Z, Single-Photon Counting, Charge-Integrating, Detectors, Sensors
16:30 RTSD-01-07

Response of a Timepix4 CdTe spectral imaging detector for radiographic applications (#2859)

L. A. Cerbone1, 2, J. Žemlička4, B. Bergmann4, P. Smolyanskiy4, P. Manek4, L. Cimmino2, 3, G. Mettivier2, 3, S. Pospíšil4, P. Russo2, 3

1 Scuola Superiore Meridionale, SPACE PhD program, Napoli, Italy
2 University of Naples Federico II, Dept. of Physics, Napoli, Italy
3 Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, Napoli, Italy
4 Institute of Experimental and Applied Physics, Prague, Czech Republic

Abstract

We characterized a Timepix4 application-specific integrated circuit bonded to a 1-mm-thick cadmium telluride sensor for photon-counting X-ray imaging in the diagnostic energy range. A per-pixel energy calibration was performed using X-ray fluorescence and gamma-ray sources, followed by a cluster-wise linear correction to compensate for spectral distortions associated with multi-pixel charge sharing and front irradiation. Flat-field, photon-counting, and spectral imaging tests were performed using a tungsten-anode microfocus X-ray tube operated at 80 kV. The detector achieved an energy resolution of 3.3 keV at 59.5 keV for the Am-241 source. Spectral images were reconstructed using 1 keV energy bins after offline clustering and fluorescence recovery correction. The detector demonstrated high-quality radiographic imaging capability after flat-field correction, despite spatial inhomogeneities typical of fine-pitch CdTe hybrid pixel detectors. A limiting spatial resolution of 8 lp/mm at 10% modulation transfer function was measured for the detector biased at -450 V, at a counting rate approaching 107 cps per chip. The results demonstrate the potential of the Timepix4 CdTe assembly for spectral imaging applications.

AcknowledgmentL.A.C. acknowledges UNINA for supporting her research stay at IEAP through the STAR grant awarded for the DXA4A project (PI: L.A.C.).
References
[1] X. Llopart, J. Alozy, R. Ballabriga, M. Campbell, R. Casanova, V. Gromov, et al., “Timepix4, a large area pixel detector readout chip which can be tiled on 4 sides providing sub-200 ps timestamp binning,” J. Instrum., vol. 17, no. 1, Jan. 2022, Art. no. C01044, doi: 10.1088/1748-0221/17/01/C01044.
[2] J. Jakubek, A. Cejnarova, T. Holy, S. Pospisil, J. Uher, and Z. Vykydal, “Pixel detectors for imaging with heavy charged particles,” Nucl. Instrum. Methods Phys. Res. A, vol. 591, no. 1, pp. 155–158, May 2008, doi: 10.1016/j.nima.2008.03.091.
Keywords: Timepix4, CdTe sensor, photon-counting detectors, X-ray imaging, medical imaging.
16:45 RTSD-01-08

Exploring the X-ray imaging with single-crystalline integrated perovskite sensors (#1569)

V. Bartosh1, 2, A. Sakhatska1, 2, K. Sakhatskyi1, 2, G. J. Matt1, 2, A. Kanak1, 2, S. Yakunin1, 2, M. Kovalenko1, 2

1 ETH Zurich, Laboratory of Inorganic Chemistry, D-CHAB, Zürich, Zürich, Switzerland
2 EMPA, Laboratory for Thin Films and Photovoltaics, Dübendorf, Zürich, Switzerland

Abstract

Metal halide perovskites emerge as promising materials for direct X-ray detection due to their high absorption efficiency, favorable charge-transport properties, and compatibility with scalable fabrication methods[1, 2]. While thin polycrystalline perovskite films integrated with pixelated electronics have already demonstrated high-resolution imaging[3], extending these approaches toward thicker highly crystalline absorbers remains essential for practical low-dose applications. Here, we investigate several perovskite multi-pixel detector architectures coupled to charge-integrating readout electronics for low-dose X-ray imaging. The developed devices exhibit stable operation, uniform photoresponse, and spatial resolution approaching pixel pitch limit. Highly crystalline film CsPbBr3 detectors demonstrate spatial resolution up to 20 lp mm-1, keeping high X-ray absorption and efficient charge collection together with scalable fabrication potential, while bulk single-crystalline integrated absorbers provide further improvements in charge collection and uniform low-dose response. Thick 3-4 mm single crystal sensors achieve modulation transfer function values of 35% at the Nyquist frequency under X-ray doses as low as 4 µGyair with a detective quantum efficiency of 48%. In addition, we demonstrate high-contrast radiographic imaging of packaged integrated circuit and computed tomography of small multi-material objects, highlighting the potential of perovskite detectors for next-generation high-resolution imaging systems.

AcknowledgmentThe work was financially supported by the Swiss Innovation Agency (Innosuisse) under grant agreement 46894.1 IP-ENG and through the ETH+ Project SynMatLab: Laboratory for Multiscale Materials Synthesis. Authors also acknowledge Prof. Dr. Makhsud Saidaminov and his group from the University of Victoria, Canada, for providing MAPbBr3 single crystals.
References
[1] Yakunin, S., Dirin, D., Shynkarenko, Y., Morad, V., Cherniukh, I., Nazarenko, O. et al., "Detection of gamma photons using solution-grown single crystals of hybrid lead halide perovskites," Nature Photon, vol. 10, pp. 585–589, 2016.
[2] He, Y., Petryk, M., Liu, Z., Chica, D. G., Hadar, I., Leak, C. et al., "CsPbBr3 perovskite detectors with 1.4% energy resolution for high-energy γ-rays," Nature Photon, vol. 15, pp. 36–42, 2021.
[3] Y. Kim, Kim, K.-H., Son, D.-Y., Jeong, D.-N., Seo J.-Y., Choi, Y. S. et al., "Printable organometallic perovskite enables large-area, low-dose X-ray imaging," Nature, vol. 550, pp. 87–91, 2017
[4] Chen, H., Gu, M., Liu, X., Huang, S., Liu, B., Zhang, J., "Spatial resolution and light output of pixelated CsI(Tl) scintillation screen based on oxidized silicon micropore array template," JINST, vol. 13, no. P07002, 2018.
[5] Mei. K., Roshkovan, L., Halliburton, S.S., Sharma, S., Ross, S., Yu, Z.  et al., "Evaluation of a CZT-based photon-counting detector CT prototype for low-dose lung cancer screening using patient-specific lung phantoms," medRxiv, p. 2025.12.30.25343218, 2025.
[6] Haruta, Y., Ye, H., Huber, P., Sandor, N., Pavesic Junior, A. et al., "Reproducible high-quality perovskite single crystals by flux-regulated crystallization with a feedback loop," Nature Synthesis, vol. 3, no. 10, pp. 1212–1220, 2024.
[7] R. Najjar, "Radiology's Ionising Radiation Paradox: Weighing the Indispensable Against the Detrimental in Medical Imaging," Cureus, vol. 15, no. 7, p. e41623, 2023.
Keywords: perovskites, single crystal, X-ray imaging, spatial resolution, computed tomography


Our Exhibitors: